
Installation and Maintenance Instructions
2.9
2.0
1.2
Ø1.2
1.2
Ø1.2
2.3
2.8
INCREASE
SETPOINT
DECREASE
SETPOINT
GLASS-FILLED
POLYCARBONATE
UPPER HOUSING
BRASS LOWER
HOUSING WITH
1-1/8 HEX
WELDED STAINLESS
STEEL BODY
1/4 NPT MALE
WITH 9/16 HEX
1/4 NPT MALE
#18 AWG-12˝ WIRE
LEADS
for ASHCROFT®A-Series Miniature
Pressure Switches
FIELD ADJUSTABLE (APA) MODELS ONLY
tandard Ranges – 30IMV, 15, 30, 60, 100, 200, 400, 600, 1000 psi
S
APA-NS / APA-RS
ODUCTION
INTR
The APA pressure switch features an all-welded stainless steel
body (APA-NS/RS) or a machined brass pressure connection
le glass-filled polycarbonate upper hous
combined with a dur
ab
ing (APA-NS/RB). Located inside the upper housing lies one
(D/M) SPDT general purpose or gold contact snap acting
switches.The deadband is fixed and the setpoint is field
adjustable.
ring clockwise to increase setpoint, counterclockwise to
decrease setpoint.
arious pressure connections and electrical terminations.
v
The setpoint can be adjusted by rotating the outer
The AP
A pressure s
witch is supplied with
ELECTRICAL CONNECTION
The APA pressure switch is available with many various electrical connections; wire leads (L), screw terminals (S), spade ter-
-
minals (T) and a Form C DIN connector (H). Contact factory for
other special connection requirements
When furnished with wire leads, the wires are color coded.
(White-Common, Blue-Normally Open, Red-Normally Closed.)
er to figure below f
Ref
spade and DIN connections
When furnished with a DIN connector the terminal block of
the connector can be removed by first removing the screw from
the center of the connector, then pushing out the terminal block
INST
Torque should always be applied to the hex portion of the body
when installing, never to any other part of the body for it may
alter the setpoint. It is recommended that Teflon tape or other
sealant be used on the threads prior to installing to prevent
leaks in the system.
through the hole in the top of the connector to force it out the
bottom.
block back into housing.
Attach wires to the terminal block then insert terminal
Make all connections according to the figures below and
circuit requirements
Note: Since v
acuum models are already abo
TION
ALLA
atmosphere, the Common and Normally Open (NO) circuit will be closed as received.
© 2007 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614-5145, USA, Tel:203-378-8281, Fax:203-385-0499, www.ashcroft.com
All sales subject to standard ter
ms and conditions of sale
.
I&M009-10046-10/00 (250-2966) GBE 1/07
APA-NB / APA-RB
or identification of ter
.
.
.
minals f
ve the setpoint at
or scre
w,

Installation and Maintenance Instructions
NORMALLY
CLOSED
NORMALLY
OPENED
C
OMMON
M
ARKED
W
/WHITE DOT
COMMON
NORMALLY OPENED
NORMALLY
CLOSED
.25
.43
12
6/250
3
G
DS N
1
2
S
R
for ASHCROFT®A-Series Miniature
Pressure Switches
1 – COMMON
2 – NORMALLY CLOSED
3 – NORMALLY OPEN
SCREW TERMINALS
OTHER OPTIONS
NORMALLY CLOSED
LOAD 1
NORMALLY OPEN
LOAD 2
SP ADE TERMINALS
COMMON
LINE VOLT A GE
WIRING DIAGRAM
FORM “C”
DIN CONNECTOR
© 2007 Ashcroft Inc., 250 East Main Street, Stratford, CT 06614-5145, USA, Tel:203-378-8281, Fax:203-385-0499, www.ashcroft.com
All sales subject to standard terms and conditions of sale.
SS
I&M009-10046-10/00 (250-2966) GBE 1/07
X3A
CONDUIT CONNECTION