Ashcroft A2 Specifications

Page 1
Data Sheet
A2 Pressure Transmitter
FEATURES
ranges, pressure connections and electrical
terminations Output: select voltage or current versions Available with externally adjustable zero and span
access
TYPICAL USES
Test stands Compressor control Hydraulic systems Process automation Pump and pneumatic systems control
PERFORMANCE SPECIFICATIONS
Reference Temperature:
Accuracy Class (Includes non-linearity):
Best Fit Straight Line (BFSL):
Durability: >10 million cycles
Stability: ≤±0.25% span/year at reference conditions
ENVIRONMENTAL SPECIFICATIONS
Temperature Effects:
Temperature Limits:
Humidity Effects:
FUNCTIONAL SPECIFICATIONS
Response Time: <2ms
Pressure Ranges: Vacuum, gauge, compound and absolute pressure
Shock: 100g Peak, 11ms
Random Vibration: 10g RMS, 20-2,000Hz
Sweep Vibration: 50-2,000Hz, 5g peak
Position Effect: ±0.02%, typical
Overpressure: ≤300 psi ≥500 to ≤10,00 psi
70°F (21°C)
±0.25%, ±0.5%, ±1.0% of span Terminal Point Method includes: hysteresis, non-repeatability, zero offset and span setting errors
±0.2%, ±0.4%, ±0.5% of span Add ±0.05% for ranges >5,000 psi
-4°F to 185°F (-20°C to 85°C) ±1.0% of span for ±0.25% accuracy class ±2.0% of span for ±0.5% and ±1.0% accuracy class
Storage:
Operating:
Compensated:
0-95% R.H. non-condensing (no effects) 0-100% R.H. with welded enclosure (no effects)
from 0 to 5 psi through 0 to 10,000 psi (Bar ranges available)
Proof:
1.5 X Range
1.2 X Range
–40°F to 257°F (–40°C to 125°C) –40°F to 257°F (–40°C to 125°C) –4°F to 185°F (–20°C to 85°C)
Burst: 2 X Range
1.5 X Range
A2
Pressure Transmitter
KEY BENEFITS
• Provides the user with accurate, reliable, and stable output data
• Board microprocessor provides extremely linear and precise performance over the entire pressure and temperature range
ELECTRICAL SPECIFICATIONS
Circuit Protection: Reverse polarity and mis-wire protected
Insulation Resistance (Circuit Case):
Output Signal:
0-5 mA (3 Wire) 0-10 mA (3 Wire) 1-5 mA (3 Wire) 1-6 mA (3 Wire) 4-20 mA (2 Wire)
Electrical Terminations:
100 MΩ @ 30 Vdc
Supply Voltage: (unregulated) Min. Max. 12 Vdc 36 Vdc 14 Vdc 36 Vdc 10 Vdc 36 Vdc 10 Vdc 36 Vdc 12 Vdc 36 Vdc
See ordering code on page 3 for options
All speci fications are subject to change without notice.
All sales subject to standard terms and conditions.
©2019 Ashcroft Inc. a2_transducer_ds_ RevB_Ltr_03-19
of 41
ashcroft.com
info@ashcroft.com
1.800.328.8258
Page 2
Data Sheet
A2 Pressure Transmitter
PHYSICAL SPECIFICATIONS
Environmental
IP65, NEMA 4X
Rating:
WETTED MATERIAL
Diaphragm Process Connection
316L SS or 17-4 PH 316L SS
NON-WETTED
Housing
304 SS
LOAD LIMITATIONS 4-20 mA OUTPUT ONLY
,
RL-Loop Resistance (Ω)
Vdc
= 12V + (0.022A* X (RL))
Min
RL = RS+ RW RL = Loop Resistance (ohms)
RS = Sense Resistance (ohms) RW = Wiring Resistance (ohms) * (Includes a 10% safety factor)
All speci fications are subject to change without notice.
All sales subject to standard terms and conditions.
©2019 Ashcroft Inc. a2_transducer_ds_ RevB_Ltr_03-19
of 42
ashcroft.com
info@ashcroft.com
1.800.328.8258
Page 3
Data Sheet
A2 Pressure Transmitter
ORDERING CODE Example:
Model
A2 - Industrial pressure transmitter A2
Enclosure
S - Basic S Z - Zero and s pan access Y - Welded wi th zero & spa n acces s W - Welded w/out zero & span access
Accuracy/Temp. Effects
A - 0.25%/≤1.0%(-20°C to 85°C) A B - 0.50%/≤2.0%(-20°C to 85°C) C - 1.0%/≤2.0%(-20°C to 85°C)
Pressure Connection
F01 - 1⁄8 NPT Male F02 - ¼ NPT Fem ale F04 - ½ NPT Female F09 - 9⁄16-18 (¼)-Female (Aminco®) FRW - 7⁄16-20 SAE-Female MEK - 7⁄16-20 SAE-Male MG2 - G¼ Male MG4 - G½ Male M01 - 1⁄8 NPT Male M01 M02 - ¼ NPT Male M04 - ½ NPT Male VM2 - VCR pro cess connection ¼˝ VCR gland w/ 9⁄16-18 Male nut VF2 - VCR process connection ¼˝ VCR gland w/ 9⁄16-18 Female nut S15 - Sanitary Seal 1½˝ Tri-Clamp S20 - Sanitary Seal 2˝ Tri-Clamp
Output Signal
05 - 0-5 Vdc 05 10 - 0-10 Vdc 15 - 1-5 Vdc 16 - 1-6 Vdc 42 - 4-20 mA
Electrical Termination
Integral Cable (Pigtail)
F2 - 3´ shielded cable (available with enclosure code or S, Z) F2 P1 - Specify leng th (available with enclosure code or S, Z)
Hirschmann® Sty le Form A D IN 43650-A
DN - W/o mating co nn. (available with enclosure code or S, Z) D0 - With mate, no cable (available with enclosure code or S, Z) D2 - With mate, 3´ cable (available with enclosure code or S, Z) D1 - With mate, s pecif y length (available with enclosure code or S, Z)
4-Pin Bendix® Style
B4 - W/o mating conn. (available with enclosure code or S, Z, W, Y) H1 - With mate, no cable (available with enclosure code or S, Z, W, Y) L1 - With mate, 3´ cable (available with enclosure code or S, Z, W, Y) P2 - With mate, specify leng th (available with enclosure code or S, Z, W, Y)
½ NPT-M Con duit S hiel ded Ca ble (NEMA Rat ing no t valid for ranges 30 0 psi)
C1 - 3´ shielded cable (available with enclosure code W, Y) C6 - 15´ shielde d cable (available with enclosure code W, Y) C7 - 30´ shielded cable (available with enclosure code W, Y) P7 - Shielded cable specif y length (available with enclosure code W, Y)
½ NPT-M Con duit F lying Leads (NEMA R atin g not val id for ranges 300 psi)
C2 - 3´ flying leads (available with enclosure code W, Y) C5 - 10´ flying le ads (available with enclosure code W, Y)
M12 Threaded
EW - W/o mating conn. (available with enclosure code or S, Z) E0 - With Male no cable (available with enclosure code or S, Z) E2 - With Male 3´ cable (available with enclosure code or S, Z) E1 - With Male (s pecif y length) (available with enclosure code or S, Z)
Pressure Range (see range table on pag e 4)
50# - 50 psi 50#
Measurement Type
G - Gauge pressure G A - Absolute pressure
Opti on (if i ncluding an optio n(s) mu st include an “X’’) X _ _
CL - Non-standard calibration K8 - 17-4PH SS sensor material 6B - Cleaned for oxygen ser vice 6B
®
®
A2 S A M01 05 F2 50# G –X6B
All speci fications are subject to change without notice.
All sales subject to standard terms and conditions.
©2019 Ashcroft Inc. a2_transducer_ds_ RevB_Ltr_03-19
of 43
ashcroft.com
info@ashcroft.com
1.800.328.8258
Page 4
Data Sheet
A2 Pressure Transmitter
DIMENSIONS in [ ] are millimeters
For reference only, consult Ashcroft for specific dimensional drawings
Heavy Industrial (Enclosure S, Z, Y, W)
4.45
[113]
3.065 [78]
0.50 [13]
2.20
[56]
0.885
[22]
1.06 [27]
DIA.
1.06 [27] Hex. Common For All Pressure Fittings
4.78
[121]
0.88
[22.5]
3.065 [78]
0.675 [17]
1.06 [27]
DIA.
RANGE TABLE
Range Code Notes
0 psi/-14.7 psi 0#&vac
Vacuum
15 psi/-14.7 psi 15# &v ac
30 psi/-14.7 psi 30#&vac
45 psi/-14.7 psi 45#&vac Gauge pressure only
Compound
17-4PH SS sensor not available, gauge pressure only
17-4PH SS sensor not available, gauge pressure only
17-4PH SS sensor not available, gauge pressure only
60 psi/-14.7 psi 60#&vac Gauge pressure only
1.5 psi 1.5 #
5 psi 5#
10 psi 10#
17-4PH SS sensor not available, gauge pressure only, available with accuracies B or C only
17-4PH SS sensor not available, gauge pressure only
17-4PH SS sensor not available, gauge pressure only
15 psi 15 # 17-4PH SS sensor not available
30 psi 30# 17-4PH SS sensor not available
50 psi 50#
60 psi 60#
75 psi 75#
100 psi 100#
150 psi 150 #
200 psi 200#
300 psi 300#
500 psi 500#
750 psi 750#
Positive Pressure
1,000 psi 1000#
1,500 psi 1500 #
2,000 psi 2000#
3,000 psi 3000#
5,000 psi 5000#
6,000 psi 6000#
7,500 psi 7500#
10,000 psi 10000# 17-4PH SS sensor required
All speci fications are subject to change without notice.
All sales subject to standard terms and conditions.
©2019 Ashcroft Inc. a2_transducer_ds_ RevB_Ltr_03-19
of 44
ashcroft.com