1125/1125A Differential Pressure Gauge
FEATURES
 Rugged design  1125A has 12 o’clock pointer position  Electric contacts (Optional)  Available with diaphragm seals
TYPICAL USES
 Refineries  Chemical and petrochemical plants  Water and wastewater pressure control  Mining and metals  Filtration monitoring, level and flow measurement
SPECIFICATIONS
Accuracy: ±2-1-2% of span (ASME B40.100 Grade 1A)
Sizes: 4½˝ or 6˝
Ranges: 10 to 1,000 psi
Process Connection: ¼ NPT
Process Connection Location:
Case Style: Open Front
Window Material: Glass
Dial: White painted aluminum with black markings Pointer: Black
Weather Protection: Case is not sealed and reccomended for
Movement: Bronze
Mounting Options: Stem or surface
WETTED COMPONENTS
Bourdon Tube Process Connection Joints
Grade A phosphor
bronze
NON-WETTED COMPONENTS
Case Ring Back Cover
Cast aluminum,
black epoxy coated
Lower or back
weather protected environment only
Bronze Soldered
Aluminum,
black epoxy coated
Aluminum
1125
4½˝, 6˝ dial sizes
1125A
4½˝, 6˝ dial sizes
KEY BENEFITS
• Built in back flange for surface or wall mounting
• Zero center dial to indicate positive or negative pressure
• Compatible with diaphragm seals
MIN/MAX TEMPERATURE LIMITS
Version Ambient Process Storage
Dry
-20°F to 200°F
(-29°C to 93°C)
-20°F to 250°F
(-29°C to 121°C)
-40°F to 250°F
(-40°C to 121°C)
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
©2 019 Ash cr oft In c. 1125_ gauge _ds _ R evB _Lt r_ 0 4-11-19
of 51
ashcroft.com
info@ashcroft.com
Data Sheet
1125/1125A Differential Pressure Gauge
ORDERING CODE Example:
Dial Size
45 - 4½˝ 45
60 - 6˝
Models
1125 - Aluminum, open front case 1125
1125A - Aluminum, open front case - zero center dial
Process Connection Size
02 - ¼ NPT Male 02
Process Connection Location
L - Lower L
B - Lower back
Options (if choosing an option(s) must include a “X”) X__
45 1125 02 L XC4 100#
Windows/Pointers
PD - Acrylic window
SG - Safety glass
EP - Maximum pointer
EQ - Minimum pointer
SH - Red set hand, stationary
EO - Red set hand, adjustable
Switch Outputs
ED - Dual setpoint, high and low contacts (specify magnetic or inductive contacts)
EE - Dual setpoint, double high contacts (specify magnetic or inductive contacts)
EF - Dual setpoint, double low contacts (specify magnetic or inductive contacts)
EG - Dual setpoint, off at low and high and on in-between
Other
C4 - Individual calibration chart C4
NH - SS tag wired to case
Range (coding example only, see range tables for all standard ranges)
100# - 100 psid 100 #
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
©2 019 Ash cr oft In c. 1125_ gauge _ds _ R evB _Lt r_ 0 4-11-19
of 52
ashcroft.com