![](/html/a0/a011/a011af071ca723353ea8e0fd2ba7817693038725ebeb2875a9270957efc1ab58/bg1.png)
Type 1036 In-Line Sanitary Pressure Gauge
Type 1037 Sanitary Instrument Fitting
FEATURES
Type 1036 Sanitary Gauge
• All-welded SS wetted surfaces
• Field liquid-fillable gauge case
• True ZeroTM pointer indication
• PowerFlexTM movement for
extended life
• Easy ZeroTM external pointer
adjustment standard
• Retrofits Anderson Instrument
CPM design
Type 1037 Fitting
• Pipe O.D. sizes from 1⁄
2˝ thru 2˝
• 316L SS
• Electropolished 12-20RA (microinches)
internal surface finish
• Heat number of wetted materials
stamped on each fitting
• Actual material certificates and certificate of conformance supplied as standard to EN 10204:2004 3.1
• Both 1036 and 1037 are 3A-74
compliant
Note: XLL Plus!™ design is not recommended
for gauges expected to be exposed to
temperatures over 200°F (93°C). This
includes gauges subject to autoclaving.
Designed specifically for the
pharmaceutical, biotechnology and food
processing markets, the Ashcroft® Type
1036 in-line sanitary pressure gauge and
Type 1037 sanitary instrument fitting
virtually eliminate process dead-leg. The
design of the Type 1036 sanitary gauge
and 1037 instrument fitting allows for the
diaphragm of the gauge to be positioned
flush with the gauge instrument fitting,
eliminating the pocket or deadleg that
may cause contamination.
The Type 1036 sanitary gauge and
Type 1037 instrument fitting utilize a
standard 11⁄2˝ Tri-Clamp® connection and
clamp. This feature offers flexibility to use
the Ashcroft Type 1036 with the Type
1037 instrument fitting on sanitary instrument fittings for pipe sizes from 1⁄2˝ thru 2˝.
The Ashcroft Type 1036 sanitary pressure gauge and 1037 fitting can be autoclaved or sterilized
(1)
, and cleaned (CIP)
or steamed in place (SIP). The gauge
comes standard with True Zero™ pointer
indication. Since the Type 1036 has no
dial stop pin, the gauge pointer always
indicates a true reading.
(1)
Optional polysulfone window required.
BULLETIN SG-4
HOW TO ORDER 1036 (Typical example)
35 1036 S L 15 L XXX 100#
Dial Size: 31⁄
Case Type:
System Mat’l: SS
Fill: (L) Glycerin
Connection Size: 1.5˝ seal
Connection Location: Lower
X Variations
Range
HOW TO ORDER 1037 (Typical example) Please use part number reference below
Product Part Number
Size
1
3
1˝ 10 1037 292C139-03
11/2˝ 15 1037 292C139-04
2˝ 20 1037 292C139-05
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
© 2017 Ashcroft Inc. 08/17
2 ˝
Code To Order
/2˝ 50 1037 292C139-01
/4˝ 75 1037 292C139-02
Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
Tel: 203-378-8281 • Fax: 203-385-0408
email: info@ashcroft.com • www.ashcroft .com
![](/html/a0/a011/a011af071ca723353ea8e0fd2ba7817693038725ebeb2875a9270957efc1ab58/bg2.png)
Type 1036 In-Line Sanitary Pressure Gauge
Type 1037 Sanitary Instrument Fitting
SPECIFICATIONS - Type 1036
Dial Size: 31⁄2˝ (only)
Accuracy: 1.5% F.S. for pressure ranges 100 psi and
above. 2.0% F.S. for vacuum, compound and ranges
below 100 psi.
Case & Ring Material: 304 SS
Ring Type: Bayonet, removable
Bourdon Tube and Socket Material: 316L SS
Diaphragm Material & Surface Finish:
316L SS, 12 to 20RA (microinches)
Diaphragm O-Ring: Buna-N
® (1)
Viton
(XVD), EPDM (XEM)
®(1)
(standard),
Connection Location: Lower 11/2˝ Triclamp® only
System Fill: USP food grade glycerin
Window Material: Polycarbonate
Pointer: Black-painted aluminum with external zero
adjust (Easy ZeroTM)
Dial: White with black markings
Movement: 300 series SS
Agency Approvals: 3A compliance to sanitary
standard 74
Ranges: 15# thru 600#, including compound
& vacuum
Clean or Steam in Place: (CIP or SIP):
Temperature limit of 200°F (138°C)
Autoclave or Sterilize
(1)
: Temperature limit of 300°F
(149°C) when supplied with polysulfone window
A polysulfone window for autoclave/sterilization must be
provided. Specify the XPS variation.
SPECIFICATIONS - Type 1037 CODE
316L SS construction std.
Wetted parts electropolished to
12 to 20RA (microinches) surface finish std.
Heat number stamped on fitting std.
The standard 1036 is supplied with a Buna-N® O-ring.
Optonal O-rings can be ordered. Order XVD for Viton
and XEM for EPDM.
(1) XLL Plus!™ design is not recommended for gauges
expected to be exposed to temperatures over 200°F
(93°C). This includes gauges subject to autoclaving.
®
DIMENSIONS -
Type 1036 In-Line Sanitary
Pressure Gauge
4.175
[106.05]
.855
[21.72]
1.506
[38.25]
3.97
[100.9]
1.980
[50.29]
.45
[11.4]
.876
[22.25]
1.286
[32.67]
3.593
[91.25]
Buna-N o-ring included
.225
[5.72]
Note: The 1036 sanitary gauge fits into all sizes of the 1037 fitting.
DIMENSIONS -
Type 1037 Instrument Fitting
L
2.0
[50]
1.5
[38]
C
A
B
Inch/mm A B C D L
1
⁄
2˝ .38 .98 .81 .31 5.25
50 (9.6) (24.9) (20.6) (7.9) (133.4)
3
⁄
4˝ .63 .98 .93 .43 5.25
75 (15.9) (24.9) (23.6) (10.9) (133.4)
1˝ .87 1.98 1.05 .55 4.75
10 (22.1) (50.4) (26.7) (14.1) (120.7)
11⁄
2˝ 1.37 1.98 1.31 .81 5.50
15 (34.7) (50.4) (33.3) (20.6) (139.7)
2˝ 1.86 2.51 1.56 (1.06 (7.00
20 (47.2) (62.8) (39.6) 26.9) 177.8)
Note: Mounting any of these models in other than a vertical
position could cause non-compliance with 3A-74.
D
BULLETIN SG-4
All specifications are subject to change without notice.
All sales subject to standard terms and conditions.
© 2017 Ashcroft Inc. 08/17
Ashcroft Inc., 250 East Main Street, Stratford, CT 06614 USA
Tel: 203-378-8281 • Fax: 203-385-0408
email: info@ashcroft.com • www.ashcroft .com