Asco Pneumatic Controls 8210 User Manual

%
)
Features
• Wide range of pressure ratings, sizes, and resilient materials provide long service life and low internal leakage.
• High Flow Valves for liquid, corrosive, and air/inert gas service.
• Industrial applications include:
- Air compressors - Industrial water control
- Pumps
2.09 R4
Pilot Operated
General Service Solenoid Valves
Brass or Stainless Steel Bodies
3/8" to 2 1/2" NPT
NC
NO
2/2
SERIES
8210
Solenoid Enclosures
Electrical
Nominal Ambient Temperature Ranges:
Red-Hat II/ Red-Hat AC: 32˚F to 125˚F (0˚C to 52˚C)
Red-Hat II DC: 32˚F to 104˚F (0˚C to 40˚C) Red-Hat DC: 32˚F to 77˚F (0˚C to 25˚C)
(104˚F/40˚C occasionally)
Refer to Engineering Section for details.
Approvals:
CSA certified. Red-Hat II meets applicable CE directives.
Refer to Engineering Section for details.
Standard: Red-Hat II - Watertight, Types 1, 2, 3, 3S, 4, and 4X; Red-Hat - Type I. Optional: Red-Hat II - Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6,
6P, 7, and 9; Red-Hat - Explosionproof and Watertight, Types 3, 4, 4X, 7, and 9. (To order, add prefix “EF” to catalog number, except Catalog Numbers 8210B57, 8210B58, and 8210B59. Valves not available with Explosionproof enclosures.)
See Optional Features Section for other available options.
Construction
4
qwer
Valve Parts in Contact with Fluids
Body Brass 304 Stainless Steel
Seals and Discs NBR or PTFE
Disc-Holder PA
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel
Springs 302 Stainless Steel
Shading Coil Copper Silver
Watt Rating and
Power Consumption
Standard
Coil and Class of
Insulation
F - 6.1 16 40 238210 - 238214 -
F 11.6 10.1 25 70 238610 238710 238614 238714
F 16.8 16.1 35 180 272610 97617 272614 97617 F - 17.1 40 93 238610 - 238614 ­F - 20 43 240 99257 - 99257 ­F - 20.1 48 240 272610 - 272614 ­H 30.6 - - - - 74073 - 74073 H 40.6 - - - - 238910 238914
Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz). 6, 12, 24, 120, 240 volts DC. Must be specified when ordering. Other voltages available when required.
DC
Watts
Watts
AC General Purpose Explosionproof
VA
HoldingVAInrush
Spare Coil Part Number
AC DC AC DC
Specifications (English units)
4
SERIES
8210
2.10 R4
UL
Listing
Watt Rating/ Class of Coil Insulation
AC DC
6.1/F 11.6/F
6.1/F 11.6/F
17.1/F 11.6/F
17.1/F 11.6/F
16.1/F -
10.1/F 11.6/F
10.1/F 11.6/F
Operating Pressure Differential (psi)
Pipe
Orifice
Size
Size
(ins.)
NORMALLY CLOSED (Closed when de-energized), NBR or PTFE Seating
3/8 3/8 1.5 3/8 5/8 3 0 150 150 - 40 40 - 180 150 8210G93 5D 3/8 5/8 3 5 200 150 135 125 100 100 180 150 8210G1 6D 3/8 5/8 3 5 300 300 300 - - - 175 - 8210G6 5D 1/2 7/16 2.2 1/2 5/8 4 0 150 150 - 40 40 - 180 150 8210G94 5D 1/2 5/8 4 0 150 150 125 40 40 - 175 150 - - - 8210G87 7D 1/2 5/8 4 5 200 150 135 125 100 100 180 150 8210G2 6D 1/2 5/8 4 5 300 300 300 - - - 175 - 8210G7 5D
1/2 3/4 4 5 - 300 - - 300 - 180 125 8210G227 5D 3/4 5/8 4.5 0 150 150 125 40 40 - 175 150 - - - 8210G88 7D 3/4 3/4 5 5 125 125 125 100 90 75 180 150 8210G9 9D 3/4 3/4 5 0 150 150 - 40 40 - 180 150 8210G95 8D 3/4 3/4 6.5 5 250 150 100 125 125 125 180 150 8210G3 11D 3/4 3/4 6 0 - - - 200 180 180 - 77 3/4 3/4 6 0 350 300 200 - - - 200 -
1 1 13 0 - - - 100 100 80 - 77 8210B54 ‡ 31D - 8210D89 15D - - 30.6/H 1 1 13 0 150 125 125 - - - 180 - 8210G54 41D 1 1 13 5 150 150 100 125 125 125 180 150 8210G4 12D 1 1 13.5 0 300 225 115 - - - 200 - 8210G27 ‡ 42P
1 1 13.5 10 300 300 300 - - - 175 ­1 1/4 1 1/8 15 0 - - - 100 100 80 - 77 8210B55 ‡ 32D - - - - - 30.6/H 1 1/4 1 1/8 15 0 150 125 125 - - - 180 - 8210G55 43D 1 1/4 1 1/8 15 5 150 150 100 125 125 125 180 150 8210G8 16D 1 1/2 1 1/4 22.5 0 - - - 100 100 80 - 77 8210B56 ‡ 33D - - - - - 30.6/H 1 1/2 1 1/4 22.5 0 150 125 125 - - - 180 - 8210G56 ‡ 44D 1 1/2 1 1/4 22.5 5 150 150 100 125 125 125 180 150 8210G22 18D
2 1 3/4 43 5 150 125 90 50 50 50 180 150 8210G100 20P 2 1/2 1 3/4 45 5 150 125 90 50 50 50 180 150 8210G101 21P
NORMALLY OPEN (Open when de-energized), NBR Seating (PA Disc-Holder, except as noted)
3/8 5/8 3 0 150 150 125 125 125 80 180 150 8210G33 23D 3/8 5/8 3 5 250 200 200 250 200 200 180 180 1/2 5/8 4 0 150 150 125 125 125 80 180 150 8210G34 23D 1/2 5/8 3 0 150 150 100 125 125 80 180 150 - - - 8210G30 37D 1/2 5/8 4 5 250 200 200 250 200 200 180 180 3/4 3/4 5.5 0 150 150 125 125 125 80 180 150 8210G35 25D 3/4 5/8 3 0 150 150 100 125 125 80 180 150 - - - 8210G38 38D 3/4 3/4 6.5 5 - - - 250 200 200 - 180 8210C13 24D 3/4 3/4 6.5 5 250 200 200 - - - 180 - 8210G13 46D
1 1 13 0 125 125 125 - - - 180 -
1 1 13 5 - - - 125 125 125 - 180 8210D14 26D
1 1 13 5 150 150 125 - - - 180 - 8210G14 47D 1 1/4 1 1/8 15 0 125 125 125 - - - 180 ­1 1/4 1 1/8 15 5 - - - 125 125 125 - 180 8210D18 28D 1 1/4 1 1/8 15 5 150 150 125 - - - 180 - 8210G18 48D 1 1/2 1 1/4 22.5 0 125 125 125 - - - 180 ­1 1/2 1 1/4 22.5 5 - - - 125 125 125 - 180 8210D32 29D 1 1/2 1 1/4 22.5 5 150 150 125 - - - 180 - 8210G32 49D
2 1 3/4 43 5 - - - 125 125 125 - 150 8210103 30P
2 1 3/4 43 5 125 125 125 - - - 180 - 8210G103 50P 2 1/2 1 3/4 45 5 - - - 125 125 125 - 150 8210104 27P 2 1/2 1 3/4 45 5 125 125 125 - - - 180 - 8210G104 51P
Notes: 5 psi on Air; 1 psi on Water. Valve provided with PTFE main disc. Valve includes UItem (G.E. trademark) piston. Letter "D" denotes diaphragm construction; "P" denotes piston construction. Safety Shutoff Valve; General Purpose Valve. Refer to Engineering Section (Approvals) for details.
(ins.)
Cv Flow
Factor
Min.
Max. AC Max. DC
Air-
Inert
Gas
150 125 - 40 40 - 180 150
150 125 - 40 40 - 180 150
Water
Light Oil
@ 300
SSU
Air-
Inert
Gas
Water
Light Oil
@ 300
SSU
Max. Fluid
Temp. ˚F
AC DC
Brass Body Stainless Steel Body
Constr.
Ref.
Catalog Number
8210G73
8210G15
8210B26 ‡ 8210G26
8210G78
8210G11
8210G12
8210B57
8210B58
8210B59
Valves not available with Explosionproof enclosures. On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. AC construction also has PA seating. No disc-holder. Stainless Steel disc-holder. ‡ Must have solenoid mounted vertical and upright.
UL
● ❍ ❍ ❍
● ❍
❍ ❍ ❍
❍ ❍ ❍
● ❍
● ❍
8210G36
8210G37
Catalog Number
8210G89 45D
No.
Listing
1P
2P
10P - - - - - 30.6/H 40P
13P - - - - 17.1/F -
39D
39D
34D
35D
36D
Constr.
Ref.
No.
1P
- - - 10.1/F 11.6/F
- - - 6.1/F 11.6/F
- - - 17.1/F ­2P
- - - 10.1/F 11.6/F
- - - 6.1/F 11.6/F
- - - 17.1/F -
- - - 17.1/F 40.6/H
- - - 6.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - 6.1/F 11.6/F
- - - 16.1F -
- - - 6.1/F 11.6/F
- - - 20.1/F -
- - - 16.1/F -
- - - 6.1/F 11.6/F
- - - 16.1/F -
- - - 6.1/F 11.6/F
- - - 6.1/F 11.6/F
- - - 6.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - - 16.8/F
- - - 16.1/F -
- - - 20/F -
- - - - 16.8/F
- - - 16.1/F -
- - - 20/F -
- - - - 16.8/F
- - - 16.1/F -
- - - 20/F -
- - - - 16.8/F
- - - 16.1/F -
- - - - 16.8/F
- - - 16.1/F -
- - - - 16.8/F
- 16.1/F -
Specifications (Metric units)
2.11 R4
SERIES
8210
4
UL
Watt Rating/ Class of Coil Insulation
AC DC
6.1/F 11.6/F
6.1/F 11.6/F
17.1/F 11.6/F
17.1/F 11.6/F
16.1/F -
10.1/F 11.6/F
10.1/F 11.6/F
Operating Pressure Differential (bar)
Max. AC Max. DC
Pipe
Orifice
Size
(mm)
Kv Flow
Factor
(m3/h)
Size
(ins.)
NORMALLY CLOSED (Closed when de-energized), NBR or PTFE Seating
3/8 10 1.29 3/8 16 2.57 0 10 10 - 3 3 - 81 65 8210G93 5D 3/8 16 2.57 0.3 14 10 9 9 7 7 81 65 8210G1 6D 3/8 16 2.57 0.3 21 21 21 - - - 79 - 8210G6 5D 1/2 11 1.89 1/2 16 3.43 0 10 10 - 3 3 - 81 65 8210G94 5D 1/2 16 3.43 0 10 10 9 3 3 - 79 65 - - - 8210G87 7D 1/2 16 3.43 0.3 14 10 9 9 7 7 81 65 8210G2 6D 1/2 16 3.43 0.3 21 21 21 - - - 79 - 8210G7 5D
1/2 19 3.43 0.3 - 21 - - 21 - 81 52 8210G227 5D 3/4 16 3.86 0 10 10 9 3 3 - 79 65 - - - 8210G88 7D 3/4 19 4.29 0.3 9 9 9 7 6 5 81 65 8210G9 9D 3/4 19 4.29 0 10 10 - 3 3 - 81 65 8210G95 8D 3/4 19 5.57 0.3 17 10 7 9 9 9 81 65 8210G3 11D 3/4 19 5.14 0 - - - 14 12 12 - 25 3/4 19 5.14 0 24 21 14 - - - 92 -
1 25 11.14 0 - - - 7 7 6 - 25 8210B54 ‡ 31D - 8210D89 15D - - 30.6/H 1 25 11.14 0 10 9 9 - - - 81 - 8210G54 41D 1 25 11.14 0.3 10 10 7 9 9 9 81 65 8210G4 12D 1 25 11.57 0 21 16 8 - - - 92 - 8210G27 ‡ 42P
1 25 11.57 0.7 21 21 21 - - - 79 ­1 1/4 29 12.86 0 - - - 7 7 6 - 25 8210B55 ‡ 32D - - - - - 30.6/H 1 1/4 29 12.86 0 10 9 9 - - - 81 - 8210G55 43D 1 1/4 29 12.86 0.3 10 10 7 9 9 9 81 65 8210G8 16D 1 1/2 32 19.29 0 - - - 7 7 6 - 25 8210B56 ‡ 33D - - - - - 30.6/H 1 1/2 32 19.29 0 10 9 9 - - - 81 - 8210G56 ‡ 44D 1 1/2 32 19.29 0.3 10 10 7 9 9 9 81 65 8210G22 18D
2 44 36.86 0.3 10 9 6 3 3 3 81 65 8210G100 20P 2 1/2 44 38.57 0.3 10 9 6 3 3 3 81 65 8210G101 21P
NORMALLY OPEN (Open when de-energized), NBR Seating (PA Disc-Holder, except as noted)
3/8 16 2.57 0.0 10 10 9 9 9 6 81 65 8210G33 23D 3/8 16 2.57 0.3 17 14 14 17 14 14 81 81 1/2 16 3.43 0 10 10 9 9 9 6 81 65 8210G34 23D 1/2 16 2.57 0 10 10 7 9 9 6 81 65 - - - 8210G30 37D 1/2 16 3.43 0.3 17 14 14 17 14 14 81 81 3/4 19 4.71 0 10 10 9 9 9 6 81 65 8210G35 25D 3/4 16 2.57 0 10 10 7 9 9 6 81 65 - - - 8210G38 38D 3/4 19 5.57 0.3 - - - 17 14 14 - 81 8210C13 24D 3/4 19 5.57 0.3 17 14 14 - - - 81 - 8210G13 46D
1 25 11.14 0 9 9 9 - - - 81 -
1 25 11.14 0.3 - - - 9 9 9 - 81 8210D14 26D
1 25 11.14 0.3 10 10 9 - - - 81 - 8210G14 47D 1 1/4 29 12.86 0 9 9 9 - - - 81 ­1 1/4 29 12.86 0.3 - - - 9 9 9 - 81 8210D18 28D 1 1/4 29 12.86 0.3 10 10 9 - - - 81 - 8210G18 48D 1 1/2 32 19.29 0 9 9 9 - - - 81 ­1 1/2 32 19.29 0.3 - - - 9 9 9 - 81 8210D32 29D 1 1/2 32 19.29 0.3 10 10 9 - - - 81 - 8210G32 49D
2 44 36.86 0.3 - - - 9 9 9 - 65 8210103 30P
2 44 36.86 0.3 9 9 9 - - - 81 - 8210G103 50P 2 1/2 44 38.57 0.3 - - - 9 9 9 - 65 8210104 27P 2 1/2 44 38.57 0.3 9 9 9 - - - 81 - 8210G104 51P
Notes: 0.3 bar on Air; 0.0 bar on Water. Valve provided with PTFE main disc. Valve includes UItem (G.E. trademark) piston. Letter "D" denotes diaphragm construction; "P" denotes piston construction. Safety Shutoff Valve; General Purpose Valve. Refer to Engineering Section (Approvals) for details.
Air-
Inert
Gas
Min.
10 9 - 3 3 - 81 65
10 9 - 3 3 - 81 65
Water
Light Oil
@ 300
SSU
Air-
Inert
Gas
Light Oil
Water
@ 300
SSU
Max.Fluid
Temp. ˚C
AC DC Catalog Number
8210G11
8210G12
8210B57
8210B58
8210B59
Valves not available with Explosionproof enclosures. On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts. AC construction also has PA seating. No disc-holder. Stainless Steel disc-holder.
Must have solenoid mounted vertical and upright.
Brass Body Stainless Steel Body
8210G73
8210G15
8210B26 ‡ 8210G26
8210G78
Constr.
Ref.
UL
No.
Listing
1P
2P
10P - - - - - 30.6/H 40P
13P - - - - 17.1/F -
39D
39D
34D
35D
36D
● ❍ ❍ ❍
● ❍
❍ ❍ ❍
❍ ❍ ❍
● ❍
● ❍
Catalog Number
8210G36
8210G37
8210G89 45D
Constr.
Ref.
No.
Listing
1P
- - - 10.1/F 11.6/F
- - - 6.1/F 11.6/F
- - - 17.1/F ­2P
- - - 10.1/F 11.6/F
- - - 6.1/F 11.6/F
- - - 17.1/F -
- - - 17.1/F 40.6F
- - - 6.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - 6.1/F 11.6/F
- - - 16.1F -
- - - 6.1/F 11.6/F
- - - 20.1/F -
- - - 16.1/F -
- - - 6.1/F 11.6/F
- - - 16.1/F -
- - - 6.1/F 11.6/F
- - - 6.1/F 11.6/F
- - - 6.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - 10.1/F 11.6/F
- - - - 16.8/F
- - - 16.1/F -
- - - 20/F -
- - - - 16.8/F
- - - 16.1/F -
- - - 20/F -
- - - - 16.8/F
- - - 16.1/F -
- - - 20/F -
- - - - 16.8/F
- - - 16.1/F -
- - - - 16.8/F
- - - 16.1/F -
- - - - 16.8/F
- - - 16.1/F -
2.12 R4
Dimensions: inches (mm)
Constr. Refs. 1, 2
SERIES
8210
Constr. Refs. 5-9, 11, 20, 21, 23 , 25, 37,38
4
Constr. Ref. 13
L
W
P
K
H
Constr.
Ref. No.
1* ins. 3.85 3.00 1.91 3.41 1.69
2* ins. 4.17 3.25 2.28 3.63 1.69
13 ins. 4.44 3.22 3.75 4.19 5.81
5 ins. 3.84 2.31 2.75 3.28 2.28
6* ins. 3.38 1.94 2.75 2.80 2.28
7 ins. 4.19 2.50 2.81 3.47 2.39
8 ins. 4.13 2.47 2.81 3.44 2.29
9* ins. 3.66 2.10 2.81 2.96 2.28
10*
11* ins. 4.16 2.66 3.84 3.52 2.75
12 ins. 5.64 3.15 3.75 4.01 3.36
15* ins. 5.34 X 3.75 4.47 3.84
16 ins. 5.64 3.15 3.66 4.01 3.56
18 ins. 6.11 3.30 4.38 4.16 3.92
20* ins. 7.33 3.71 5.06 4.57 4.87
21* ins. 7.33 3.71 5.50 4.57 4.87
23 ins. 4.35 2.65 2.75 3.79 2.28
24 ins. 5.06 X 3.78 4.44 2.75
25 ins. 4.64 2.81 2.81 3.94 2.28
26 ins. 6.53 X 3.75 4.91 3.19
27 ins. 8.22 X 5.50 5.47 4.87
28 ins. 6.53 X 3.66 4.91 3.19
29 ins. 7.03 X 4.38 5.06 4.40
Valves must be mounted with solenoid vertical
and upright. * DC dimensions slightly larger.
H K L P W
mm 98 76 49 87 43
mm 106 83 58 92 43
mm 113 82 95 106 147
mm 98 59 70 83 58
mm 86 49 70 71 58
mm 106 64 71 88 61
mm 105 63 71 87 58
mm 93 53 71 75 58 ins. 5.25 X 2.81 4.59 2.31 mm 133 X 71 117 59
mm 106 68 98 89 70
mm 143 80 95 102 85
mm 136 X 95 114 98
mm 143 80 93 102 90
mm 155 84 111 106 100
mm 186 94 129 116 124
mm 186 94 140 116 124
mm 110 67 70 96 58
mm 129 X 96 113 70
mm 118 71 71 100 58
mm 166 X 95 125 81
mm 209 X 140 139 124
mm 166 X 93 125 81
mm 179 X 111 129 112
Dimensions: inches (mm)
SERIES
8210
Constr. Refs. 10, 15, 24, 26-36
4
L
P
H
K
W
Constr. Refs. 12, 16, 18
2.13 R4
Constr.
Ref. No.
30 ins. 8.22 X 5.06 5.47 4.87
31 ins. 5.25 X 3.75 4.44 3.25
32 ins. 5.69 X 3.66 4.69 3.25
33 ins. 6.06 X 4.38 4.94 3.91
34 ins. 6.91 X 3.75 6.09 3.25
35 ins. 7.34 X 3.66 6.34 3.25
36 ins. 7.66 X 4.38 6.56 3.91
37 ins. 4.61 2.75 2.81 3.89 2.39
38 ins. 4.61 2.75 2.81 3.89 2.39
39 ins. 5.42 2.31 2.75 4.86 3.80
40 ins. 5.20 3.29 2.81 4.50 2.28
41 ins. 5.13 3.10 3.75 4.32 3.25
42 ins. 6.43 4.40 3.93 5.62 3.25
43 ins. 5.57 3.35 3.66 4.57 3.25
44 ins. 5.90 3.57 4.38 4.79 3.91
45 ins. 5.26 3.17 3.75 4.38 3.84
46 ins. 4.95 3.10 3.84 4.31 2.75
47 ins. 6.43 3.59 3.75 4.81 3.52
48 ins. 6.43 3.59 3.66 4.81 3.73
49 ins. 6.91 3.75 4.38 4.96 4.40
50 ins. 8.13 4.15 5.06 5.37 4.87
51 ins. 8.13 4.15 5.50 5.37 5.18
IMPORTANT: Valves may be mounted in any
position, except as noted in specifications table.
H K L P W
mm 209 X 129 139 124
mm 133 X 95 113 83
mm 145 X 93 119 83
mm 154 X 111 125 99
mm 176 X 95 155 83
mm 186 X 93 161 83
mm 1.95 X 111 167 99
mm 117 70 71 99 61
mm 117 70 71 99 61
mm 138 59 70 123 97
mm 132 83 71 114 58
mm 130 79 95 110 83
mm 163 112 100 143 83
mm 142 85 93 116 83
mm 150 91 111 122 99
mm 134 81 95 111 98
mm 126 79 98 110 70
mm 163 91 95 122 90
mm 163 91 93 122 95
mm 176 95 111 126 112
mm 207 105 129 136 124
mm 207 105 140 136 132
SERIES
8210
4
Dimensions: inches (mm)
2.14 R4