4
GUARANTEED SAME DAY SHIPMENT
*
Dust collector valves are high-flow, fast operating valves designed
for use in dust collector systems.
• Integral pilot constructions contain solenoids for local control
• Remote constructions require a separate pilot solenoid valve
Supplied with internal slip fit connection on outlet. Extended ends for Dresser connections.
Dust Collector 2/2 Normally Closed 1/8" - 1 1/2"
Pipe
Size
(in)
Orifice
(in)CvFlow
Operating Pressure
Differential (psi)
Max.
Fluid
Temp.˚F
Valve Catalog
Number
Body
Material
Sealing
Material Voltage
Valve
Order Code Wattage
Approvals
Rebuild Kit
Order Code
Replacement
Coil Order Code
Approx.
Shipping
Weight
(lbs.)
Min.
Max.
Air UL FM
2/2 Normally Closed Integral Pilot Main Pulse Valves Inline
1 1 1/8 20 5 125 150 8353G041 AL HYTREL 120/60,110/50 21005 6.1 - - 316563 238210-032-D* 2.5
1 1/2 2 53 5 125 150 8353J039 AL HYTREL 120/60,110/50 21542 10.1 - - 322108 238610-032-D* 4.3
2/2 Normally Closed Integral Pilot Main Pulse Valves with Compression Fittings
3/4 3/4 15 5 125 150 8353G052 AL HYTREL 120/60,110/50 21017 6.1 - - 316563 238210-032-D* 2.7
1 1 1/8 20 5 125 150 8353G053 AL HYTREL 120/60,110/50 21025 6.1 - - 316563 238210-032-D* 2.9
2/2 Normally Closed Remote Pilot Main Pulse Valves Inline
3/4
3/4 10.5 5 125 185 8353C030 AL NBR - 02425 - - - 096875 - 1.5
3/4
3/4 10.5 5 125 185 8353C004 AL NBR - 02070 - - - 096875 - 1.5
3/4 3/4 10.5 5 125 185 8353C033 AL NBR - 02071 - - - 096875 - 1.5
1 1 1/8 20 5 125 150 8353C035 AL HYTREL - 02073 - - - 200262 - 1.7
1 1/2 2 53 10 125 150 8353H038 AL HYTREL - 21539 - - - 276886 - 3.5
2/2 Normally Closed Remote Pilot Main Pulse Valves with Compression Fittings
3/4 3/4 15 5 125 150 8353055 AL HYTREL - 02827 - - - 200262 - 1.5
1 1 1/8 20 5 125 150 8353056 AL HYTREL - 02828 - - - 200262 - 2.9
1 1/2 2 50 10 125 150 8353A057 AL HYTREL - 21538 - - - 276886 - 3.8
2/2 Normally Closed Pilot Valves
1/8 1/8
0.34 0 155 180 X8262C002-13200 BR NBR 120/60,110/50 00951 8.1 - - 308047 099216-001-D* 2.3
0.35 0 125 180 USF8257A001 BR NBR 120/60,110/50 03256 10 - - - - 0.5
Manual Reset 3/2 Universal 1/4"
Manual reset valves use manual reset assemblies in conjunction
with the solenoid in order to prevent inadvertent valve startup in
their designed failure modes.
No voltage release valves can be latched by moving the lever to the
latched position when the solenoid is energized, the valve trips when the
solenoid is de-energized. When tripped the valve can be manually cycled
open/closed but the solenoid must be energized to re-latch.
Electrically tripped valves can be latched when the lever is moved to the
latched position and the solenoid is de-energized. The valve trips when
the solenoid is energized by a continuous or momentary (0.3 seconds
minimum) electrical signal.
• Three-way (3/2) universal operation (can function as NC, NO,
diverter of one fluid, or selector of 2 fluids)
• Size range of 1/4" to 1/2"
Pipe
Size
(in)
Orifice
(in)CvFlow
Operating Pressure Differential (psi)
Max.
Fluid
Temp.˚F
Valve Catalog
Number
Body
Material
Sealing
Material Voltage
Valve
Order
Code Wattage
Approvals
Rebuild
Kit Order
Code
Replacement Coil
Order Code
Approx.
Shipping
Weight
(lbs.)Min.
Max.
Air Wa ter Light Oil UL FM
3/2 Universal Operation No Voltage Release
1/4 11/64 0.38 0 125 125 125 180 EF8308B040 BR NBR 120/60,110/50 21569 20
- 318718 099257-005-D* 3.0
3/2 Universal Operation Electrically Tripped
1/4 11/64 0.38 0 125 125 125 180 EF8310B040 BR NBR 120/60,110/50 21573 20
- 318720 099257-005-D* 3.0
Pipe
Size
(in)
Orifice
(in)CvFlow
Operating Pressure
Differential (psi)
Max.
Fluid
Temp.˚F
Valve Catalog
Number
Body
Material
Sealing
Material Voltage
Valve
Order
Code
Approvals
Pilot
Pressure (psi)
Fluid
Temp.˚F
Wattage
Pilot Valve
Catalog
Number
Approx.
Shipping
Weight
(lbs.)
Pilot Min. Pilot Max. Main Max. UL FM Min. Max. Min. Max.
3/2 Universal Low Power - No-Voltage Release
3/8 1/4 0.45 25 125 125 140 EV8308G385 BR FKM 24/DC 02982
- 25 125 -40 140 1.4 EF8314G300 8.0