Asante Technologies NetStacker II User Manual

SHBBook Page 1 Wednesday, March 3, 1999 8:03 PM
NetStacker II
Dual Speed Stackable Hub
User’s Manual
SHBBook Page 2 Wednesday, March 3, 1999 8:03 PM
Copyright Notice Trademarks
Asanté Technologies and FriendlyNET are trademarks of Asanté Technologies, Inc. Ethernet is a registered trademark of the Xerox Corporation. All brand names and products are trademarks or registered trade­marks of their respective holders.
FCC Information
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
Operation of this equipment in a residential area is likely to cause interference, in which case, the user, at his or her own risk and expense, will be required to correct the interference.
FIVE YEAR LIMITED WARRANTY Subject to the limitations and exclusions below, Asanté warrants to the original end user purchaser that the
covered products will be free from defects in materials and manufacturing workmanship for a period of 5 years from date of purchase. This warranty excludes fans, power supplies and accessories. Asanté warrants that the fans and power supplies contained in covered products will be free from defects in materials and manufacturing workmanship for one year from date of purchase.
To take advantage of this warranty, you must: (1)contact Asanté for a return materials authorization (RMA) number. The RMA number must be clearly
written on the outside of the returned package.(2)Product must be sent to Asanté postage paid. (3)Provide Asanté with proof of the original date of purchase.
During the warranty period, Asanté’s sole obligation, and your ex clusive remedy is that Asanté will r epair or replace defective product or components with new, refurbished or equivalent product or components as deemed appropriate by Asanté in its sole discretion. The foregoing is your exclusive remedy, and Asanté’s only warranty obligation.
Asanté makes no warranty with respect to accessories (including but not limited to cables, brackets and fas­teners) included with the covered product. No warranty is made as to any discontinued product, which is defined as product purchased more than thirty days after Asanté has removed such product from its price list or discontinued shipments of such product.
This warranty is exclusive and is limited to the original end-user purchaser only. This warranty shall not apply to secondhand products or to products that have been modified or subjected to abuse, misuse, abnor­mal electrical or environmental conditions, or any condition other than what can be considered normal use.
ASANTÉ MAKES NO OTHER WARRANTIES, EXPRESS, IMPLIED OR OTHERWISE, REGARDING THE ASANTÉ PRODUCTS. EXCEPT T O THE EXTENT SPECIFICALLY MANDA TED BY APPLICABLE LAW, ALL WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICU­LAR PURPOSE ARE HEREBY DISCLAIMED.
ASANTÉ’S LIABILITY ARISING FROM OR RELATING TO THE PURCHASE, USE OR INABILITY TO USE THE PRODUCTS IS LIMITED TO REPAIR, REPLACEMENT OR A REFUND OF THE PURCHASE PRICE PAID. IN NO EVENT SHALL ASANTÉ BE LIABLE FOR INDIRECT , SPECIAL, INCIDENT AL, OR CONSEQUENTIAL DAMAGES OF ANY KIND OR CHARACTER FOR THE BREACH OF ANY EXPRESS OR IMPLIED WARRANTY, INCLUDING ECONOMIC LOSS, DAMAGE TO PROPERTY AND, TO THE EXTENT PERMITTED BY LAW, DAMAGES FOR PERSONAL INJURY, HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY (INCLUDING NEGLIGENCE). THESE LIMITA­TIONS SHALL APPLY EVEN IF ASANTÉ HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAM­AGES OR IF THIS WARRANTY OR ANY CLAUSE HEREIN IS FOUND TO FAIL OF ITS ESSENTIAL PURPOSE.
YOU MUST COMPLETE AND RETURN THE WARRANTY REGISTRATION CARD WITHIN 30 DAYS OF YOUR PURCHASE TO PRESERVE WARRANTY BENEFITS.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may have other rights, which vary from jurisdiction to jurisdiction.
SHBBook Page i Wednesday, March 3, 1999 8:03 PM
Table of Contents
About This Manual .................................................iii
Chapter Contents .............................................. iii
Document Conventions .....................................iv
Important Safety Instructions ............................iv
Introduction .......................................................... 1-1
Package Contents ......................................... 1-1
The NetStacker II Hubs .................................. 1-1
Performance Features ...................................1-3
Installation ........................................................... 2-1
Components ................................................... 2-1
Front Panels of 12 Port and 24 Port Hubs 2-1 Rear Panels of 12 Port and 24 Port Hubs 2-3
Cabling and Voltage Requirements ...............2-4
Cabling Requirements .............................. 2-4
Voltage Requirements .............................. 2-4
Placement and Mounting ...............................2-5
Hub Location ............................................ 2-5
Desktop Mounting ..................................... 2-5
Rack Mounting .......................................... 2-5
Connecting Network Devices .........................2-6
Connecting Workstations or Servers ........ 2-6
Connecting to Another Hub ......................2-7
Stacking Hubs ........................................ 2-10
Powering on the Hub ................................... 2-11
Page i
SHBBook Page ii Wednesday, March 3, 1999 8:03 PM
LED Indicators .....................................................3-1
Power LED .....................................................3-2
Collision Indicator LEDs .................................3-2
Hub ID Number LEDs .....................................3-3
Port Link Activity Indicator LEDs ....................3-3
10Mbps Link Activity LEDs .......................3-3
100Mbps Link Activity LEDs .....................3-3
Troubleshooting ...................................................A-1
Specifications .......................................................B-1
Technical Support ............................................... C-1
Contacting Technical Support .................. C-1
Page ii
SHBBook Page iii Wednesday, March 3, 1999 8:03 PM
About This Manual
This manual describes the NetStacker II dual speed stackable hubs. The manual focuses on the following two models:
12-port 10/100Mbps managed stackable hub ❑ 24-port 10/100Mbps managed stackable hub
Unless otherwise noted, all information provided in this manual is applicable to both units.
Chapter Contents
This manual is divided into the following chapters and appendices:
Chapter 1, “Introduction,” provides an overview of the NetS tacker II
dual speed stackable hubs and their features Chapter 2, “Installation,” describes the components and explains
how to install, mount, and apply power to the NetStacker II dual speed stackable hubs
Chapter 3, “LED Indicators,” describes how to interpret the LEDs
on the NetStacker II dual speed stackable hubs
Appendix A, “Troubleshooting,” explains how to solve problems by
monitoring the LEDs on the NetStacker II dual speed stackable hubs
Appendix B, “Specifications,” describes the NetStacker II dual speed
stackable hubs’ technical specifications
Appendix C, “Technical Support” explains how to contact Asanté
Technical Support
Page iii
SHBBook Page iv Wednesday, March 3, 1999 8:03 PM
Document Conventions
This manual uses the term “NetStacker II” to refer to the 12 port and 24 port dual speed hubs, and “hub” to refer to all other Ethernet hubs.
This manual uses the following conventions to convey instructions and information:
Note: Noteworthy information, which contains helpful
suggestions or references to other sections in the manual, is in this format.
Important! Significant information that calls attention to
important features or instructions is in this format.
Important Safety Instructions
1. Read all of these instructions.
2. Save these instructions for later use.
3. Follow all warnings and instructions marked on the product.
4. Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
5. Do not use this product near water.
6. Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product.
7. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register. This product should not be placed in a built-in installation unless proper ventilation is provided.
8. This product should be operated from the type of pow er sour ce indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.
9. This product is equipped with a three-wire grounding type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the purpose of the grounding type plug.
10. Do not allow anything to rest on the power cord. D o not locate this product where persons will walk on the cord.
Page iv
SHBBook Page v Wednesday, March 3, 1999 8:03 PM
About This Manual
11. If an extension cord is used with this product, make sure that the total ampere ratings on the products connected to the extension cord do not exceed the extension cord ampere rating. Also make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes.
12. Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the product.
13. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous voltage points or other risks. Refer all servicing to service personnel.
Page -v
SHBBook Page vi Wednesday, March 3, 1999 8:03 PM
Page vi
SHBBook Page 1 Wednesday, March 3, 1999 8:03 PM
Introduction
This chapter introduces the Asanté NetStacker II 12 port and 24 port dual speed stackable hubs and provides an overview of basic hub technology. The chapter is made up of the following sections:
Package Contents ❑ The NetStacker II Hubs ❑ Performance Features ❑ Network Concepts
1
Package Contents
The package contains the following items:
(1) ❑ ❑ (4) Self-adhesive rubber feet ❑ (1) Rack-mount kit, which includes two rack-mounting brackets and
User’s Manual (this book)
NetStacker II 12 port hub, or NetStacker II 24 port hub
(1) AC power cord
mounting screws
The NetStacker II Hubs
Thank you for purchasing an Asanté NetStacker II 12 port or 24 port hub. The NetStacker II products ar e unmanaged dual speed stackable hubs which provide a compact, flexible solution for medium to large workgroups and small office LANS. These 12-port and 24-port hubs comply fully with IEEE802.3 and IEEE802.3u standards.
Both the 12-port and 24-port hubs can be upgraded easily to managed hubs by addition of an optional plug-in management module. This module slides into a slot on the back panel of the hub. You do not need to purchase another hub to gain full management capabilities - you can convert your unmanaged hub in a matter of minutes.
Page 1-1
SHBBook Page 2 Wednesday, March 3, 1999 8:03 PM
Introduction
The NetStacker II 12 port unmanaged hub provides 12 twisted pair ports. The 24 port managed hub provides 24 twisted pair ports. In addition, both hubs offer an expansion slot for a 100Base-FX interface so the user can slide a fiber­optic module into the rear panel. A slot for a 100Base-FX interface is also provided on the front panel, for use when the management module has been installed in the rear panel slot.
Both hubs automatically detect the speed (10Mbps or 100Mbps) of the devices they are connected to. For additional expansion, each hub provides an Uplink push-button for the 12th port, which can be cascaded to another hub by means of straight through cable.
The NetStacker II hubs can be stacked up to 8 units high and connected by means of the “Stack Connection In” and “Stack Connection Out” ports on the rear panel. In addition, one of the hubs in the stack may be equipped with a slide-in management module. The entire stack requires only one managed hub for all of the stacked devices to be managed. Each dual speed hub has its own ID, which is auto-detected and auto-configured. You do not have to configure the hub ID yourself.
Either model hub can be placed on a tabletop or rack mounted. With unmatched flexibility, the hubs ensure operation in any LAN environment, regardless of size. The hubs provide the solutions that users require for their complex networks.
COL
100M
10M
Power
COL
100M
10M
Power
Page 1-2
1
234567
1
23456789
1
234567
13
14 15161718192021
1
23456789
8
NetStacker II
Hub ID Number
100Mbps
10Mbps
10 11
12
123456789101112
Stackable Dual-Speed Hub
Uplink
Uplink Normal
Figure 1-1 NetStacker II 12 port hub front panel
8
Hub ID Number
13 14 15 16 17 18 19 20 21 22 23 24
NetStacker II
100Mbps
10Mbps
22 23
24
100Mbps
10Mbps
10 11
12
123456789101112
Stackable Dual-Speed Hub
Uplink
Uplink Normal
Figure 1-2 NetStacker II 24 port hub front panel
NS2012
MII Module Slot
NS2024
MII Module Slot
SHBBook Page 3 Wednesday, March 3, 1999 8:03 PM
Performance Features
Each hub features full plug-and-play installation. LED indicators include power status, port link activity status, collision detection, and hub identification, for easy monitoring of hub operation.
Performance Features
The NetStacker II dual speed stackable hubs offer the following features:
Full compliance with the IEEE802.3 and IEEE802.3u Ethernet stan-
dards
12 or 24 10/100Mbps auto-sensing ports ❑ Both 12-port and 24-port hubs stackable up to eight units
Up to eight 12-port or 24-port hubs stackable with management by
means of a single slide-in management module added to one hub
Both models accept optional slide-in fiber optic module ❑ Global LEDs: power indicator, 10Mbps collision detection,
100Mbps collision detection, and 8 hub identification indicators
Port LEDs: link activity LED for both 10Mbps and 100Mbps ❑ Automatic partitioning of faulty ports ❑ Segmented hub to reduce collisions ❑ 19 inch rack-mountable size ❑ CE mark certification ❑ Internal power that supports universal input voltage
Page 1-3
SHBBook Page 4 Wednesday, March 3, 1999 8:03 PM
Introduction
Page 1-4
SHBBook Page 1 Wednesday, March 3, 1999 8:03 PM
Installation
This chapter describes the components and explains how to install, mount, and apply power to your NetStacker II dual speed hub. It contains the following sections:
Components ❑ Cabling and Voltage Requirements ❑ Placement and Mounting ❑ Connecting Network Devices ❑ Powering on the Hub
2
Components
This section describes the front and back panel layouts of the NetStacker II dual speed hubs.
Front Panels of the 12 Port and 24 Port Hubs
The front panel of the 12 port hub displays:
Twelve dual speed (UTP) Ethernet ports ❑ One uplink switch button ❑ LED indicators.
These features are shown in Figure 2-1.
1
234567
8
NetStacker II
1
23456789
Hub ID Number
100Mbps
10Mbps
10 11
12
123456789101112
COL 100M
10M
Power
Stackable Dual-Speed Hub
Uplink
Uplink Normal
Figure 2-1 NetStacker II 12 port front panel
NS2012
MII Module Slot
Page 2-1
SHBBook Page 2 Wednesday, March 3, 1999 8:03 PM
Installation
The front panel of the 24 port hub displays:
Twenty-four dual speed (UTP) Ethernet ports ❑ One uplink switch button ❑ LED indicators.
These features are shown in Figure 2-2.
Power
COL
100M
10M
1
234567
13
14 15161718192021
1
23456789
8
Hub ID Number
13 14 15 16 17 18 19 20 21 22 23 24
NetStacker II
100Mbps
10Mbps
22 23
24
100Mbps
10Mbps
10 11
12
123456789101112
Stackable Dual-Speed Hub
Uplink
Uplink Normal
NS2024
MII Module Slot
Figure 2-2 NetStacker II 24 port front panel
LED Indicators
The front panels of the NetStacker II dual speed hubs display LED indicators, as shown in Figure 2-3. The LED nomenclature, color, and function are as follows:
Power (green): Illuminates when AC power is applied to the hub. ❑ Collision “COL” (amber): A collision occurs when two or more sta-
tions in the Ethernet network attempt to transmit data at the same time. The LED flashes to indicate a collision while the stations re­transmit. There is one LED for 10Mbps and one for 100Mbps.
Hub ID Number (gr een): Indicates the ID of the hub if it is part of a
stack; this identifying number is auto-configured, from one to eight.
Link Activity “100Mbps/10Mbps” (green): Indicates that a device is
connected to the port number, and that either a 10Mbps (lower LED) or 100Mbps (upper LED) link is detected. If the link is detected, the LED turns on. If data is transmitting, the LED blinks.
Page 2-2
SHBBook Page 3 Wednesday, March 3, 1999 8:03 PM
Hub ID
1
234567
COL
100M
10M
Power
1
23456789
Power
Collision
8
Hub ID Number
NetStacker II
10 11
Components
100Mbps
10Mbps
12
100 Mbps 10 Mbps
Figure 2-3 LED Indicators on 12 port hub
Rear Panels of the 12 Port and 24 Port Hubs
The rear panels of the 12 port and 24 port hubs both display:
Management Module Slot; can also be used for optional 100Base FX
slide-in module that allows connection to fiber optic network media
Stack Connection In and Stack Connection Out: Used to join the
hubs in a stack with stacking cables (one provided per hub). Up to eight hubs may be connected together within a collision domain.
Fan vents ❑ AC Power socket ❑ Power switch
These features are shown in Figure 2-4.
Management Module Slot
Figure 2-4 NetStacker II rear panel
Stack Connection In
Stack Connection Out
On
100–240Vac Off
Page 2-3
SHBBook Page 4 Wednesday, March 3, 1999 8:03 PM
Installation
Cabling and Voltage Requirements
This section describes the cabling and voltage requirements for the NetStacker II 12 port and 24 port hubs.
Note: You may connect network cable segments to the hub
or disconnect them while the power is on. Plugging in or removing cables while your hub is running will not inter­rupt the traffic or disrupt the operation of the hub.
Cabling Requirements
The cabling for connections to the NetStacker II hubs must meet or exceed the following standards:
10Base-T
10Base-T transmission connection requires UTP (Unshielded Twisted Pair) Category 3 cables, not to exceed 100 meters in length.
100Base-TX
100Base-TX transmission requires UTP (Unshielded Twisted Pair) Category 5 cables, not to exceed 100 meters in length. 100Base-TX requires that all wiring and accessories meet EIA/TIA 568B specifications for proper operation. When wiring a 100Base-TX network, make sure that the entire cable plant meets these specifications.
Important : Some installations have UTP Category 5
cabling but do not have wall outlets and/or wiring closet punchdown blocks that meet Category 5 requirements.
100Base-FX
100Base-FX transmission requires 62.5/125 micron graded-index multimode fiber-optic cable with an SC connector. For details on inserting a 100Base-FX module, see “Adding Fiber Optic Connectivity via MII” on page 11 in this chapter.
Voltage Requirements
Voltage requirements are the same for both hubs: 100 to 240VAC, at 50 to 60Hz, with a 1.2A maximum.
Important : Check the AC power line voltage used in your
area.
Page 2-4
SHBBook Page 5 Wednesday, March 3, 1999 8:03 PM
Placement and Mounting
Placement and Mounting
This section describes how to mount the NetStacker II on a desktop or shelf.
Hub Location
The location chosen for the NetStacker II hub should be less than 100 meters from servers, workstations, and other devices.
Important: Category 5 cables are environment-sensitive.
Make sure that the cable route is not too close to electro­magnetic noise sources such as power lines or fluorescent lights.
Desktop Mounting
To place the hub on a desktop or shelf:
1 Attach the four rubber feet (supplied) to the bottom of
each corner on the hub. See Figure 2-5.
1
234567
8
NetStacker II
Hub ID Number
COL 100M
10M
Power
1
23456789
100Mbps
10Mbps
10 11
12
123456789101112
Stackable Dual-Speed Hub
Uplink
Uplink Normal
Figure 2-5 Desktop mounting
NS2012
MII Module Slot
2 Place the hub on a flat, stable, horizontal desktop or shelf.
Make sure you allow enough ventilation space between the
hub and surrounding objects.
Rack Mounting
A rack mount bracket is an optional way to mount hubs in standard EIA 19­inch racks.
1 Align the mounting brackets on the sides of the unit with
the slit over the holes as shown in Figure 2-6.
2 Secure the screws tightly to fix the brackets to the device.
Page 2-5
SHBBook Page 6 Wednesday, March 3, 1999 8:03 PM
Installation
3 Place the device into the 19-inch rack and attach it firmly.
Ensure that the ventilation holes do not get blocked.
1
23
4
5
13
14 15
16
17
COL
100M
Power
10M
1
23
4
5
13 14 15 16 17 18 19 20 21 22 23 24
6
7
8
NetStacker II
Hub ID Number
100Mbps
10Mbps
18
19
20
21
22 23
24
100Mbps
10Mbps
6
7
8
9
10 11
12
123456789101112
Stackable Dual-Speed Hub
Uplink
Uplink Normal
NS2024
MII Module Slot
Figure 2-6 Rack mounting
Connecting Network Devices
The Auto-sensing capability of the NetStacker II hub allows you to connect 10Mbps and/or 100Mbps devices.
Connecting Workstations or Servers
To connect your hub to workstations, servers, or other nodes:
1 Be sure each computer has either a 10Base-T or 100Base-
TX Ethernet Network Interface Card (NIC) installed
2 Connect one end of the UTP cable to the RJ-45 port of the
Ethernet card in each computer as shown in Figure 2-7.
for 10Base-T use UTP Category 3 cable or betterfor 100Base-TX use UTP Category 5 cable or better
3 Plug the other end of the cable into one of the RJ-45 ports
on the hub, as shown in Figure 2-7.
Page 2-6
SHBBook Page 7 Wednesday, March 3, 1999 8:03 PM
1
234567
COL 100M
10M
Power
1
23456789
Figure 2-7 Connecting cable to a NIC
Note: The maximum length of a cable between a hub and a device is 100 meters, including all patch cables and cross-connect wires.
4 Continue connecting workstations, servers, or other devices
to the hub using UTP cables to create a network as shown in the example in Figure 2-8.
8
Hub ID Number
10 11
NetStacker II
100Mbps
10Mbps
12
Connecting Network Devices
123456
Power
1
13
COL 100M
10M
1
234567
14 15161718192021
23456789
8
Hub ID Number
13 14 15 16 17 18 19 20 21 22 23 24
NetStacker II
100Mbps
10Mbps
22 23
24
100Mbps
10Mbps
10 11
12
123456789101112
Stackable Dual-Speed Hub
Uplink
Uplink Normal
NS2024
MII Module Slot
Figure 2-8 Connecting network devices
Connecting to Another Hub
To connect the NetS tacker II hub to a switching hub or a repeater hub , take the following steps.
1 Choose the appropriate cable depending on which port
you want to connect to on the NetStacker II hub. See Table 2-1 to determine which cable and uplink button setting you need to use.
Page 2-7
SHBBook Page 8 Wednesday, March 3, 1999 8:03 PM
Installation
2 Make sure that the length of the straight through cable
between the NetStacker II and a 100Mbps r epeater does not exceed 5 meters, including all patch cables and cross con­nect wires. The cable between the NetStacker II and any switch or any 10Mbps repeater cannot exceed 100 meters.
Note: If you need to connect more than 2 hubs via 100Mbps connections, you must have a switch separat­ing the additional hubs.
3 Connect one end of the cable to the selected RJ-45 port of
the NetStacker II hub.
4 Connect the other end of the cable to the selected RJ-45
port of the other hub. A connection from the Uplink Port (Port 12) to a non-uplink Port on another hub is shown in Figure 2-9.
5 Press the Uplink button in if your connection type and
cable require it. See Table 2-1 for Uplink button settings.
Page 2-8
Connecting: Cable Uplink Button
From Uplink Port (Port 12) To non-uplink port
From Uplink Port (Port 12) To non-uplink port
From Uplink Port (Port 12) To Uplink Port on other hub
From Uplink Port (Port 12) To Uplink Port on other hub
From non-uplink Port To non-uplink Port
From non-uplink Port To Uplink Port on other hub
From non-uplink Port To Uplink Port on other hub
Table 2-1 Connecting cables and uplink button settings
Straight through Press in
Cross-over Do not press in
Straight through Press in ONE, not
both
Cross-over Do not press in
either button
Cross-over ONLY Do not press in
Straight through Press in button on
OTHER hub
Cross-over Do not press in
either button
SHBBook Page 9 Wednesday, March 3, 1999 8:03 PM
Connecting Network Devices
Straight through cable
1
234567
8
NetStacker II
Hub ID Number
COL
100M
10M
Power
1
23456789
FRIENDLYNET
8-port Dual-speed Ethernet Hub
Power
100Mbps
10Mbps
10 11
12
123456789101112
100Mbps
10Mbps
Figure 2-9 Connecting to another hub using Uplink Port
Button pressed in
Stackable Dual-Speed Hub
Uplink
Uplink Normal
FH208P
87654321COL
100Mbps
UPLINK
LINK/ACT
NORMAL
NS2012
MII Module Slot
Page 2-9
SHBBook Page 10 Wednesday, March 3, 1999 8:03 PM
Installation
Stacking Hubs
Up to eight NetStacker II hubs may be connected within a stack. Furthermore, a management module can be installed easily in any of the stacked hubs, so that all of them can be managed. The management module communicates with a manager console by means of SNMP agent software, installed in the managed hub. This reduces considerably the expense of equipping each hub for management.
It is not necessary to configure a Hub ID for each NetStacker II hub in a stack. The auto-configure feature takes care of this for you.
1 Check the 50-pin “stacking” cable that was included in
the package with your NetStacker II hub. It is designed specifically for stacking your unit with others of the same design.
Note: Do not use any cable but the NetStacker II stack- ing cable supplied with your unit; if you need additional cables, contact Asanté support.
2 Place the hubs in a stack so the rear panels are aligned as
shown in Figure 2-10.
3 Connect the “Stack Connection Out” on the upper hub
with the “Stack Connection In” of the hub below it. Leave the “Stack Connection In” of the uppermost hub and the “Stack Connection Out” of the lowermost hub uncon­nected, as shown in Figure 2-10.
Stacking Cables
Page 2-10
Management Module Slot
Management Module Slot
Management Module Slot
Management Module Slot
Management Module Slot
Management Module Slot
Management Module Slot
Management Module Slot
Stack Connection In
Stack Connection Out
Stack Connection In
Stack Connection Out
Stack Connection In
Stack Connection Out
Stack Connection In
Stack Connection Out
Stack Connection In
Stack Connection Out
Stack Connection In
Stack Connection Out
Stack Connection In
Stack Connection Out
Stack Connection In
Stack Connection Out
100–240Vac Off
100–240Vac Off
100–240Vac Off
100–240Vac Off
100–240Vac Off
100–240Vac Off
100–240Vac Off
100–240Vac Off
Figure 2-10 Stacking NetStacker II hubs
On
On
On
On
On
On
On
On
SHBBook Page 11 Wednesday, March 3, 1999 8:03 PM
Connecting Network Devices
Adding Fiber Optic Connectivity via MII
To add connectivity for 100Base-FX transmission media, insert the optional MII fiber-optic module in the MII Module Slot in the back panel of the hub, as shown in Figure 2-11. If you have not installed a management module, this slot will be available for the fiber-optic connection module.
The MII Module Slot in the front panel of the hub is reserved for use when there is a management module installed in the Management Module Slot on the rear panel. For information on the use of this slot, see the Management Module manual.
Note: Do not use the MII Module Slot on the front panel to install a fiber-optic module unless you have installed a man­agement module in the rear panel.
Management Module Slot
MII Module
Figure 2-11 MII Module Slot on rear panel
Page 2-11
SHBBook Page 12 Wednesday, March 3, 1999 8:03 PM
Installation
Powering on the Hub
The NetStacker II hub may be turned on with (or without) LAN segment cables connected.
To power on the hub:
1 Connect one end of the power cord (supplied) into the
AC power connector on the back panel of the hub.
Note: NetStacker II hubs are equipped with an internal power supply. Pow er sensing is automatic for all interna­tional utility power.
2 Connect the power cord to a local power source outlet. 3 Click the power switch on the rear panel to the “on” posi-
tion.
Page 2-12
SHBBook Page 1 Wednesday, March 3, 1999 8:03 PM
LED Indicators
This chapter explains how to interpret the front panel LED indicators on NetStacker II dual speed hubs. There are no LEDs on the rear panel.
The LEDs are used to facilitate monitoring and troubleshooting. These LEDs are:
Power Collision Indicators Hub ID Number Port Link Activity indicators
The front panel LEDs of the 12 port and 24 port hubs are shown in Figure 3-1 and Figure 3-2.
3
Power
Power
COL
100M
10M
Collision
Hub ID
1
234567
1
23456789
8
Hub ID Number
10 11
Figure 3-1 12 port hub LEDs
NetStacker II
100Mbps
10Mbps
12
100 Mbps 10 Mbps
Page 3-1
SHBBook Page 2 Wednesday, March 3, 1999 8:03 PM
LED Indicators
Hub ID
1
234567
13
14 15161718192021
COL
100M
10M
Power
Power
Collision
1
23456789
8
Hub ID Number
NetStacker II
22 23
10 11
100Mbps
10Mbps
24
100Mbps
10Mbps
12
100 Mbps 10 Mbps 100 Mbps 10 Mbps
Figure 3-2
24 port hub LEDs
Power LED
The Power LED is green and should always be lit when the NetStacker II is in use. After power is turned on, the LED indicators should respond as follows:
All LED indicators blink momentarily. This represents a system reset. The Port Link Activity LEDs blink on. The ports that are not con-
nected then blink off.
The Power LED lights and remains ON.
If the Power LED is not lit, check to make sure that the power cord is properly connected at both ends. If the Power LED still remains unlit, determine whether the outlet is functional by plugging another device into it.
Collision Indicator LEDs
The collision indicator LEDs (labeled “COL”) are amber. The lower LED indicates collisions on a 10Mbps segment connected to the hub, and the upper LED indicates collisions on a 100Mbps segment connected to the hub. The default condition of these indicators is unlit. A collision occurs when two or more stations in the Ethernet network attempt to transmit data at the same time. If a collision is detected, the appropriate LED flashes while the stations re­transmit. Collisions may be expected when two or more workstations are connected to a hub. These collisions ar e a normal feature of ethernet traffic, and are not a problem due to re-transmission.
Page 3-2
SHBBook Page 3 Wednesday, March 3, 1999 8:03 PM
Hub ID Number LEDs
Hub ID Number LEDs
The Hub ID LEDs are a numbered row of eight green LEDs. If your NetStacker II hub is configured with other NetStacker II hubs in a stack, each hub will get an auto-configured ID number , and the LED for that number will be lit on each hub. If your hub is not part of a stack, the LED for ID number 1 will be lit.
If no Hub ID LED is lit on your N etS tacker II hub, or if more than one hub in a stack has the same ID number lit, there is a problem with the system. Check with Asanté technical support.
Port Link Activity Indicator LEDs
All NetStacker II hubs include both 100Mbps and 10Mbps Link Activity LED indicators for each port. These are the double rows of numbered green LEDs, labeled “100Mbps” and “10Mbps”. On the 12 port hub, the ports and LEDs are numbered 1–12. On the 24 port hub, ports and LEDs are numbered 1–24.
10Mbps Link Activity LEDs
The green 10Mbps LEDs (the lower row) indicate whether the ports are connected and if 10Mbps link pulses are detected at the port.If the 10Mbps link pulse is detected, the LED will be lit. The LED will blink when data is transmitting on the link.
100Mbps Link Activity LEDs
The green 100Mbps LEDs (the upper row) indicate whether the port is connected and if 100Mbps link pulses detected. If the 100Mbps link pulse is detected, the LED will be lit. The LED will blink when data is transmitting on the link.
Page 3-3
SHBBook Page 4 Wednesday, March 3, 1999 8:03 PM
LED Indicators
Page 3-4
SHBBook Page 1 Wednesday, March 3, 1999 8:03 PM
Troubleshooting
Table A-1 describes how to troubleshoot problems with your network and/or the Switch by monitoring the Switch’s LEDs.
Table A-1 Troubleshooting
Problem Indication Action
A
No Power Power LED OFF Check the power cord.
Port connection not functioning
Hub ID incor­rect
Link Activity LED OFF
No HUB ID LED lit, or same HUB ID LED lit on two hubs
Make sure the power outlet is functional. Make sure the power cord is properly connected to the outlet and is securely connected to the hub.
Make sure the cable is functioning and is properly connected at both ends. Check the crimp of the RJ-45 connectors. Make sure the UTP cable is Category 5 for 100Base-TX. Make sure the UTP cable is Category 3 for 10Base-T. Make sure the cable length does not exceed 100 meters.
Check with Asanté technical support.
Page A-1
SHBBook Page 2 Wednesday, March 3, 1999 8:03 PM
Page A-2
SHBBook Page 1 Wednesday, March 3, 1999 8:03 PM
NetStacker II Hub Specifications
B
Specifications
Standard IEEE 802.3 Ethernet standard
Interfaces RJ-45 (TP) X 12/24
Stackable Up to 8 units Indicators System: Power LED
Power 100VAC/60Hz to 240VAC/50Hz Environment Temperature: Operating: 0° C to 40° C (32° F to 104° F)
EMI FCC Class A, CE, VCCI 1 Dimensions 438mm X 257mm X 44,5mm (17.25” X 10.125” X 1.75”) Safety Regulations CUL (UL and CSA) LVD Weight 6.75 lbs (12 Port)
IEEE 802.3u Fast Ethernet standard
Stackable connector X 2 MII expansion slot for 100Base-FX module
Hub ID LEDs
Segment: 10Mbps collision LED
100Mbps collision LED
Per Port: 10M link activity LED
100M link activity LED
Storage: -20° C to 70° C (-4° F to 158° F)
Humidity: Operating: 10%RH to 90%RH
Storage: 5%RH to 90%RH
7.35 lbs (24 Port)
Page B-1
SHBBook Page 2 Wednesday, March 3, 1999 8:03 PM
Page B-2
SHBBook Page 1 Wednesday, March 3, 1999 8:03 PM
Technical Support
Contacting T echnical Support
To contact Asanté Technical Support:
Telephone (800) 622-7464 Fax (801) 566-3787 Fax-Back (800) 741-8607 E-mail support@asante.com W orld W ide Web Site http://www.asante.com
Technical Support Hours 6:00 a.m. to 5:00 p.m. Pacific Standard Time USA, Monday - Friday.
C
Page C-1
SHBBook Page 2 Wednesday, March 3, 1999 8:03 PM
SHBBook Page 1 Wednesday, March 3, 1999 8:03 PM
SHBBook Page 2 Wednesday, March 3, 1999 8:03 PM
ASANTÉ TECHNOLOGIES, INC., 821 FOX LANE, SAN JOSE, CA 95131
PHONE: 800.622.7464 • FAX: 801.566.3787 • e-mail address: sales@asante.com •
©1999 Asanté Technologies Inc. Asanté is a trademark of Asanté Technologies, Inc.
All brand names and products are trademarks or registered trademarks of their respective holders.
World Wide Web site: http://www.asante.com
March 1999 P/N 06-00507-00