Asante Technologies NetStacker II User Manual

SHBBook Page 1 Wednesday, March 3, 1999 8:03 PM
NetStacker II
Dual Speed Stackable Hub
User’s Manual
SHBBook Page 2 Wednesday, March 3, 1999 8:03 PM
Copyright Notice Trademarks
Asanté Technologies and FriendlyNET are trademarks of Asanté Technologies, Inc. Ethernet is a registered trademark of the Xerox Corporation. All brand names and products are trademarks or registered trade­marks of their respective holders.
FCC Information
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.
Operation of this equipment in a residential area is likely to cause interference, in which case, the user, at his or her own risk and expense, will be required to correct the interference.
FIVE YEAR LIMITED WARRANTY Subject to the limitations and exclusions below, Asanté warrants to the original end user purchaser that the
covered products will be free from defects in materials and manufacturing workmanship for a period of 5 years from date of purchase. This warranty excludes fans, power supplies and accessories. Asanté warrants that the fans and power supplies contained in covered products will be free from defects in materials and manufacturing workmanship for one year from date of purchase.
To take advantage of this warranty, you must: (1)contact Asanté for a return materials authorization (RMA) number. The RMA number must be clearly
written on the outside of the returned package.(2)Product must be sent to Asanté postage paid. (3)Provide Asanté with proof of the original date of purchase.
During the warranty period, Asanté’s sole obligation, and your ex clusive remedy is that Asanté will r epair or replace defective product or components with new, refurbished or equivalent product or components as deemed appropriate by Asanté in its sole discretion. The foregoing is your exclusive remedy, and Asanté’s only warranty obligation.
Asanté makes no warranty with respect to accessories (including but not limited to cables, brackets and fas­teners) included with the covered product. No warranty is made as to any discontinued product, which is defined as product purchased more than thirty days after Asanté has removed such product from its price list or discontinued shipments of such product.
This warranty is exclusive and is limited to the original end-user purchaser only. This warranty shall not apply to secondhand products or to products that have been modified or subjected to abuse, misuse, abnor­mal electrical or environmental conditions, or any condition other than what can be considered normal use.
ASANTÉ MAKES NO OTHER WARRANTIES, EXPRESS, IMPLIED OR OTHERWISE, REGARDING THE ASANTÉ PRODUCTS. EXCEPT T O THE EXTENT SPECIFICALLY MANDA TED BY APPLICABLE LAW, ALL WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICU­LAR PURPOSE ARE HEREBY DISCLAIMED.
ASANTÉ’S LIABILITY ARISING FROM OR RELATING TO THE PURCHASE, USE OR INABILITY TO USE THE PRODUCTS IS LIMITED TO REPAIR, REPLACEMENT OR A REFUND OF THE PURCHASE PRICE PAID. IN NO EVENT SHALL ASANTÉ BE LIABLE FOR INDIRECT , SPECIAL, INCIDENT AL, OR CONSEQUENTIAL DAMAGES OF ANY KIND OR CHARACTER FOR THE BREACH OF ANY EXPRESS OR IMPLIED WARRANTY, INCLUDING ECONOMIC LOSS, DAMAGE TO PROPERTY AND, TO THE EXTENT PERMITTED BY LAW, DAMAGES FOR PERSONAL INJURY, HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY (INCLUDING NEGLIGENCE). THESE LIMITA­TIONS SHALL APPLY EVEN IF ASANTÉ HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAM­AGES OR IF THIS WARRANTY OR ANY CLAUSE HEREIN IS FOUND TO FAIL OF ITS ESSENTIAL PURPOSE.
YOU MUST COMPLETE AND RETURN THE WARRANTY REGISTRATION CARD WITHIN 30 DAYS OF YOUR PURCHASE TO PRESERVE WARRANTY BENEFITS.
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may have other rights, which vary from jurisdiction to jurisdiction.
SHBBook Page i Wednesday, March 3, 1999 8:03 PM
Table of Contents
About This Manual .................................................iii
Chapter Contents .............................................. iii
Document Conventions .....................................iv
Important Safety Instructions ............................iv
Introduction .......................................................... 1-1
Package Contents ......................................... 1-1
The NetStacker II Hubs .................................. 1-1
Performance Features ...................................1-3
Installation ........................................................... 2-1
Components ................................................... 2-1
Front Panels of 12 Port and 24 Port Hubs 2-1 Rear Panels of 12 Port and 24 Port Hubs 2-3
Cabling and Voltage Requirements ...............2-4
Cabling Requirements .............................. 2-4
Voltage Requirements .............................. 2-4
Placement and Mounting ...............................2-5
Hub Location ............................................ 2-5
Desktop Mounting ..................................... 2-5
Rack Mounting .......................................... 2-5
Connecting Network Devices .........................2-6
Connecting Workstations or Servers ........ 2-6
Connecting to Another Hub ......................2-7
Stacking Hubs ........................................ 2-10
Powering on the Hub ................................... 2-11
Page i
SHBBook Page ii Wednesday, March 3, 1999 8:03 PM
LED Indicators .....................................................3-1
Power LED .....................................................3-2
Collision Indicator LEDs .................................3-2
Hub ID Number LEDs .....................................3-3
Port Link Activity Indicator LEDs ....................3-3
10Mbps Link Activity LEDs .......................3-3
100Mbps Link Activity LEDs .....................3-3
Troubleshooting ...................................................A-1
Specifications .......................................................B-1
Technical Support ............................................... C-1
Contacting Technical Support .................. C-1
Page ii
SHBBook Page iii Wednesday, March 3, 1999 8:03 PM
About This Manual
This manual describes the NetStacker II dual speed stackable hubs. The manual focuses on the following two models:
12-port 10/100Mbps managed stackable hub ❑ 24-port 10/100Mbps managed stackable hub
Unless otherwise noted, all information provided in this manual is applicable to both units.
Chapter Contents
This manual is divided into the following chapters and appendices:
Chapter 1, “Introduction,” provides an overview of the NetS tacker II
dual speed stackable hubs and their features Chapter 2, “Installation,” describes the components and explains
how to install, mount, and apply power to the NetStacker II dual speed stackable hubs
Chapter 3, “LED Indicators,” describes how to interpret the LEDs
on the NetStacker II dual speed stackable hubs
Appendix A, “Troubleshooting,” explains how to solve problems by
monitoring the LEDs on the NetStacker II dual speed stackable hubs
Appendix B, “Specifications,” describes the NetStacker II dual speed
stackable hubs’ technical specifications
Appendix C, “Technical Support” explains how to contact Asanté
Technical Support
Page iii
SHBBook Page iv Wednesday, March 3, 1999 8:03 PM
Document Conventions
This manual uses the term “NetStacker II” to refer to the 12 port and 24 port dual speed hubs, and “hub” to refer to all other Ethernet hubs.
This manual uses the following conventions to convey instructions and information:
Note: Noteworthy information, which contains helpful
suggestions or references to other sections in the manual, is in this format.
Important! Significant information that calls attention to
important features or instructions is in this format.
Important Safety Instructions
1. Read all of these instructions.
2. Save these instructions for later use.
3. Follow all warnings and instructions marked on the product.
4. Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
5. Do not use this product near water.
6. Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product.
7. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or heat register. This product should not be placed in a built-in installation unless proper ventilation is provided.
8. This product should be operated from the type of pow er sour ce indicated on the marking label. If you are not sure of the type of power available, consult your dealer or local power company.
9. This product is equipped with a three-wire grounding type plug, a plug having a third (grounding) pin. This plug will only fit into a grounding type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the purpose of the grounding type plug.
10. Do not allow anything to rest on the power cord. D o not locate this product where persons will walk on the cord.
Page iv
SHBBook Page v Wednesday, March 3, 1999 8:03 PM
About This Manual
11. If an extension cord is used with this product, make sure that the total ampere ratings on the products connected to the extension cord do not exceed the extension cord ampere rating. Also make sure that the total of all products plugged into the wall outlet does not exceed 15 amperes.
12. Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the product.
13. Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous voltage points or other risks. Refer all servicing to service personnel.
Page -v
SHBBook Page vi Wednesday, March 3, 1999 8:03 PM
Page vi
SHBBook Page 1 Wednesday, March 3, 1999 8:03 PM
Introduction
This chapter introduces the Asanté NetStacker II 12 port and 24 port dual speed stackable hubs and provides an overview of basic hub technology. The chapter is made up of the following sections:
Package Contents ❑ The NetStacker II Hubs ❑ Performance Features ❑ Network Concepts
1
Package Contents
The package contains the following items:
(1) ❑ ❑ (4) Self-adhesive rubber feet ❑ (1) Rack-mount kit, which includes two rack-mounting brackets and
User’s Manual (this book)
NetStacker II 12 port hub, or NetStacker II 24 port hub
(1) AC power cord
mounting screws
The NetStacker II Hubs
Thank you for purchasing an Asanté NetStacker II 12 port or 24 port hub. The NetStacker II products ar e unmanaged dual speed stackable hubs which provide a compact, flexible solution for medium to large workgroups and small office LANS. These 12-port and 24-port hubs comply fully with IEEE802.3 and IEEE802.3u standards.
Both the 12-port and 24-port hubs can be upgraded easily to managed hubs by addition of an optional plug-in management module. This module slides into a slot on the back panel of the hub. You do not need to purchase another hub to gain full management capabilities - you can convert your unmanaged hub in a matter of minutes.
Page 1-1
SHBBook Page 2 Wednesday, March 3, 1999 8:03 PM
Introduction
The NetStacker II 12 port unmanaged hub provides 12 twisted pair ports. The 24 port managed hub provides 24 twisted pair ports. In addition, both hubs offer an expansion slot for a 100Base-FX interface so the user can slide a fiber­optic module into the rear panel. A slot for a 100Base-FX interface is also provided on the front panel, for use when the management module has been installed in the rear panel slot.
Both hubs automatically detect the speed (10Mbps or 100Mbps) of the devices they are connected to. For additional expansion, each hub provides an Uplink push-button for the 12th port, which can be cascaded to another hub by means of straight through cable.
The NetStacker II hubs can be stacked up to 8 units high and connected by means of the “Stack Connection In” and “Stack Connection Out” ports on the rear panel. In addition, one of the hubs in the stack may be equipped with a slide-in management module. The entire stack requires only one managed hub for all of the stacked devices to be managed. Each dual speed hub has its own ID, which is auto-detected and auto-configured. You do not have to configure the hub ID yourself.
Either model hub can be placed on a tabletop or rack mounted. With unmatched flexibility, the hubs ensure operation in any LAN environment, regardless of size. The hubs provide the solutions that users require for their complex networks.
COL
100M
10M
Power
COL
100M
10M
Power
Page 1-2
1
234567
1
23456789
1
234567
13
14 15161718192021
1
23456789
8
NetStacker II
Hub ID Number
100Mbps
10Mbps
10 11
12
123456789101112
Stackable Dual-Speed Hub
Uplink
Uplink Normal
Figure 1-1 NetStacker II 12 port hub front panel
8
Hub ID Number
13 14 15 16 17 18 19 20 21 22 23 24
NetStacker II
100Mbps
10Mbps
22 23
24
100Mbps
10Mbps
10 11
12
123456789101112
Stackable Dual-Speed Hub
Uplink
Uplink Normal
Figure 1-2 NetStacker II 24 port hub front panel
NS2012
MII Module Slot
NS2024
MII Module Slot
SHBBook Page 3 Wednesday, March 3, 1999 8:03 PM
Performance Features
Each hub features full plug-and-play installation. LED indicators include power status, port link activity status, collision detection, and hub identification, for easy monitoring of hub operation.
Performance Features
The NetStacker II dual speed stackable hubs offer the following features:
Full compliance with the IEEE802.3 and IEEE802.3u Ethernet stan-
dards
12 or 24 10/100Mbps auto-sensing ports ❑ Both 12-port and 24-port hubs stackable up to eight units
Up to eight 12-port or 24-port hubs stackable with management by
means of a single slide-in management module added to one hub
Both models accept optional slide-in fiber optic module ❑ Global LEDs: power indicator, 10Mbps collision detection,
100Mbps collision detection, and 8 hub identification indicators
Port LEDs: link activity LED for both 10Mbps and 100Mbps ❑ Automatic partitioning of faulty ports ❑ Segmented hub to reduce collisions ❑ 19 inch rack-mountable size ❑ CE mark certification ❑ Internal power that supports universal input voltage
Page 1-3
Loading...
+ 25 hidden pages