ART DUALRDB om_dualrdb.pdf

Page 1

Dual Reamping Direct Box

Artcessories
User's Manual
Page 2
This symbol, whenever it appears, alerts you to the presence of uninsulated dangerous voltage inside enclosure-voltage that may be sufficient to constitute risk of shock.
Read Instructions: Retain safety and operating instructions for future reference. Heed all warnings printed here and on the equipment. Follow the operating instructions printed in this us er guide.
Do not open: There are no user serviceable parts inside. Refer any service work to qualified technical personnel only.
Grounding: Only connect the unit to equi pment with properly grounded mains power. Do not defeat the grounding and polarization means of the power cord plug of the connected equipment. Do not remove or tamper with the ground connection on the power cord of the connected equipment.
Environment: Protect from excessive dirt, dust, heat, and vibration when operating and stori ng. Avoid tobacco as h, drink spillage and smoke, especially that associated with smoke machines.
Handling: Protect the controls from damage during trans i t. Use adequate padding if you need to ship the unit. To avoid injury to yourself or damage to the equipment, take care when lifting, moving or carrying the unit.
Servicing: Refer servicing to qualified technical personnel.
This symbol, whenever it appears, alerts you to important operating and maintenance instructions in the accompanying literature. Please read the manual.
Page 3
Installation: Install the uni t in accordance with the instructions printed in the user guide.

INTRODUCTION:

Thanks for purchasing Applied Research and Technology’s Dual RDB. The Dual RDB is the ideal input solution for any application where stereo or dual Line level signals from Mixers, Recording interfaces, iPods, Laptop computers, consumer DVD players, Consumer HiFi equipment or video machines have to be connected to XLR microphone or 1/4" instrument level inputs. The unit has two high quality isolation transformers that prevent ground loops when connecting various systems together. The Dual RDB accepts 1/4-inch TRS and XLR line level inputs, and outputs mic or instrument levels. Variable level controls allow the Dual RDB to vary the volume control at the source. The Dual RDB is ideal for setting the volume of your component at the source, rather than in and studio, AV room, audio closet or installation rack. A 20Hz to 20kHz frequency response ensures the Dual RDB will function seamlessly with any high quality audio source.
Page 4

FEATURES:

Transformer isolated XLR microphone level outputs
Transformer isolated 1/4" TRS instrument level
outputs
20 to 20,000Hz Frequency Response
Dual XLR line level inputs
Dual 1/4-inch TRS line level inputs
Variable Level Controls that can fully mute.
CH2 source selectable between CH1 or CH2 Input
CH2 output phase switch
Balanced outputs
Page 5

INSTALLATION and OPERATION:

Connect your line level signal to INPUT 1 - 1/4" TRS phone jacks or XLR Input connector. Connect either 1/4" jack or XLR of OUTPUT 1 to an instru ment or mic input .
For dual operation, connect INPUT 2 and OUTPUT 2 in a similar manner and set the OUTPUT 2 SOURCE switch to Input 2.If you want to split INPUT 1 into two outputs, set the OUTPUT 2 SOURCE switch to Input 1.
Use the OUTPUT 2 PHASE switch to correct phase error problems elsewhere in the audio system.
Set the Output Level knobs for best signal strength and clarity.
Page 6
Signal Flow Chart
Page 7
Page 8

APPLICATIONS:

Re-amping interface for multiple amps
Stereo/Dual direct box
Variable input pad for mic or instrument inputs
Stereo Audio/Video interface to low level inputs
Page 9
SPECIFICATIONS:
Frequency Response: 20 Hz - 20 kHz, ± 0.5 dB @
+4 dBu THD: .01% @ 1kHz, +18 dBu <.05% @ 100Hz, +18dBu
Channel Separation: > 80 dB (typical) Input Connections: 1/4" TRS balanced,
XLR balanced female Output Connections: 1/4" TRS balanced, XLR balanced female Insertion loss: -20dB @100k Ohm load,
-25dB @600 Ohm load Dimensions HxWxD (in): 1.85 x 4.6 x 3.9 HxWxD(mm): 47 x 117 x 99
Weight (lbs/kg) : 0.88 / 0.40
Page 10

WARRANTY INFORMATION:

Limited Warranty (USA only)

Applied Research and Technology will provide warranty and service for this unit in accordance with the following warrants: Applied Research and Technology, (ART) warrants to the original purchaser that this product and the components thereof will be free from defects in workmanship and materials for a period of three years from the date of purchase. Applied Research and Technology will, without charge, repair or replace, at its option, defective product or component parts upon prepaid delivery to the factory service department or authorized service center, accompanied by proof of purchase date in the form of a valid sales receipt.

Exclusions

This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alterations or repairs. This warranty is void if the serial number is altered, defaced, or removed. ART reserves the right to make changes in design or make additions to or improvements upon this product without any obligation to install the same on products previously manufactured. ART shall not be liable for any consequential damages, including without limitation damages resulting from loss of use. Some states do not allow limitations of incidental
Page 11
or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific rights and you may have other rights, which vary, from state to state. The warranty terms listed above are only valid within the United States of America. For units purchased outside the United States, an authorized distributor of Applied Research and Technology will provide service. For information on warranty and service policies outside of the U.S., please contact your local distributor.
Please fill in the following information for your reference:
Date of purchase: _________________________ Purchased from: _________________________
Page 12

SERVICE:

The following information is provided in the unlikely event that your unit requires service.
1. Be sure that the unit is the cause of the problem. Check to make sure that the unit has power supplied, that all cables are connected correctly, and that the cables themselves are in working condition. You may want to consult with your dealer for assistance in troubleshooting or testing your particular configuration.
2. If you believe that the ART unit is at fault, go to
www.artproaudio.com. Select "Support", then
"Return Authorization Request" to request a return authorization number.
3. If you are returning the unit for service, pack the unit in its original carton or a reasonable substitute. The original packaging may not be suitable as a shipping carton, so consider putting the packaged unit in another box for shipping. Print the RA number clearly on the outside of the shipping box. Print your return shipping address on the outside of the box.
4. Include with your unit: a note with the RA number and your contact information, including a return shipping address (we cannot ship to a P.O. box) and a daytime phone number, and a description of the problem, preferably attached to the top of the unit. Also include a copy of your purchase receipt.
Loading...