ARRI UDM Instruction Manual

Page 1
UDM
Ultrasonic Distance Measure
Instruction Manual
As of: July 2013
ALL ARTWORK, PICTURES AND TEXTS ARE COVERED BY OUR COPYRIGHT.
THEY MUST NOT BE COPIED FOR REPRODUCTION (E.G. ON CD-ROM DISKS OR INTERNET-SITES) OR USED IN THEIR ENTIRE FORM OR IN EXCERPTS WITHOUT OUR PREVIOUS WRITTEN AGREEMENT.
IF YOU ARE DOWNLOADING PDF-FILES FROM OUR INTERNET HOME-PAGE FOR YOUR PERSONAL USE, MAKE SURE TO CHECK FOR UPDATED VERSIONS.
WE CANNOT TAKE ANY LIABILITY WHATSOEVER FOR DOWNLOADED FILES, AS TECHNICAL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE.
Page 2
1. Contents
Contents
1. Contents ............................................................ 2
2. Safety Instructions and Legal Disclaimer .... 4
2.1
Safety instructions
2.2 Disclaimer
................................................................ 5
3. General Description ........................................ 7
3.1 ARRI Order numbers
4. Setup ......................................................................... 10
5. Operation of the UDM ................................ 11
5.1
Switching on
5.2 Controls and Status LEDs
5.3
Operation Settings
5.4 Parameter Settings
5.5
Depth-of Field and Focus Tracking
6. Specifications ................................................ 14
7. ARRI Service ................................................... 15
................................................... 4
................................................. 9
........................................................ 11
.......................................... 11
............................................... 12
................................................... 12
........................... 13
Page 3
This page is left intentionally blank
Page 4
2. Safety Instructions and Legal Disclaimer
2.1. Safety instructions
The UDM has been thoroughly tested for quality of workmanship and operating functions before leaving the factory. To ensure optimal performance, it is essential that you aquaint yourself with this instruction manual and that you follow the operating instructions described.
Warning signs
Safety instructions
Possible risk of injury or damage to equipment.
This symbol indicates the risk of electric shock or fire danger that could result in injury or equipment damage.
General safety instructions
Read and understand all safety and operating instructions before you operate or install the system.
Retain all safety and operating instructions for future reference.
Do not use accessories or attachments not recommended by ARRI, as they may cause hazards and void the warranty.
Do not repair any part of the system. Repairs must only be carried out by authorized ARRI repair shops.
Do not remove any safety measure of the system.
Do not operate the system in high humidity areas or expose it to water or moisture.
Operate the system using only the type of power source indicated in the manual.
Do not use solvents to clean.
Any violation of these safety instructions or the non-observance of personal care could cause serious injuries (including death) and damages on the system or other objects.
Product Identification
When ordering parts or accessories, or if any questions should arise, please advise your type of product and serial number.
Page 5
2.2 Disclaimer
Before using the products described in this manual be sure to read and understand all respective instructions. The ARRI Wireless Lens Control System is only available for commercial customers. The customer grants by utilization, that the ARRI Ultrasonic Distance Measure (UDM) or other components of the system are only deployed for commercial use. Otherwise the customer has the obligation to contact ARRI preceding the utilization. While ARRI endeavors to enhance the quality, reliability and safety of their products, customers agree and acknowledge that the possibility of defects thereof cannot be eliminated entirely. To minimize risks of damage to property or injury (including death) to persons arising from defects in the products, customers must incorporate sufficient safety measures in their work with the system and have to heed the statuted canonic use. No part of this document may be copied or reproduced in any form or by any means without prior written consent of ARRI. ARRI assumes no responsibility for any errors that may appear in this document. The information is subject to change without notice. For actual design-in, refer to the latest publications of ARRI data sheets or data books, etc., for the most up-to-date specifications. Not all products and/or types are available in every country. Please check with an ARRI sales representative for availability and additional information.
ARRI or its subsidiaries does not assume any liability for infringement of patents, copyrights or other intellectual property rights of third parties by or arising from the use of ARRI products or any other liability arising from the use of such products. No license, express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of ARRI or others. ARRI or its subsidiaries expressly excludes any liability, warranty, demand or other obligation for any claim, representation, or cause, or action, or whatsoever, express or implied, whether in contract or tort, including negligence, or incorporated in terms and conditions, whether by statue, law or otherwise. In no event shall ARRI or its subsidiaries be liable for or you have a remedy for recovery of any special, direct, indirect, incidental, or consequential damages, including but not limited to lost profits, lost savings, lost revenues or economic loss of any kind or for any claim by third party, downtime, good-will, damage to or replacement of equipment or property, any costs or recovering of any material or goods associated with the assembly or use of our products, or any other damages or injury of persons and so on or under any other legal theory. In the case one or all of the forgoing clauses are not allowed by applicable law, the fullest extent permissible clauses by applica­ble law are validated.
ARRI is a registered trademark of Arnold & Richter Cine Technik GmbH & Co Betriebs KG.
Disclaimer
Page 6
This page is left intentionally blank
Page 7
3. General Description
The ARRI Ultrasonic Distance Measure (UDM) provides a continuous reflection-based distance measurement and automatic focus tracking, using the built-in Lens Data System of the ALEXA Plus, ARRICAM, ARRIFLEX 435 Advanced/Xtreme and ARRIFLEX 416plus cameras or the UMC-3 lens motor controller.
Main features
Measurement range from approx. 0,4 - 10m / 1ft 4in - 33ft
Selectable Meter / Feet display
Automatic focus tracking with ARRI Lens Data System equipment
Pre-set measuring limits for exact object tracking
Fine-trimming for best performance in different environments
Large transflective LCD display for good readability under all light conditions
The UDM consist of two units, the Display Unit and the Sensor Unit. 3/8“ UNC bushings allow the units to be mounted on standard supports in convenient positions. The UDM comes with an 1,5m (5ft) interface cable. Connection cables for interfacing to cameras and UMC-3 must be ordered seperately (page 9). A large control wheel on the Display Unit allows easy setting of the UDM parameters, supported by a set of status LEDs. The small toggle switch under the large LCD display changes the unit of measurement between meters and feet.
General Description
Page 8
optional power supply/data cable please refer to page 9
Sensor Unit
General Description
K2.65130.0
Display Unit
K2.65131.0
UDM-Sensor Cable (blue label)
K4.65655.0
Page 9
3.1 ARRI Order Numbers
K0.60055.0 Ultrasonic Distance Measure UDM complete
The package includes:
K2.65130.0 UDM Sensor Unit
K2.65131.0 UDM Display Unit
K4.65655.0 Cable UDM-Sensor (1,5m/5ft) connects Sensor Unit to Display Unit
K5.65999.0 UDM User Manual EN
Optional Accessory:
K4.65656.0 Cable UDM-CAM (1,5m/5ft) connects UDM Sensor Unit to ARRICAM - CAC
K4.65672.0 Cable UDM-435 (1,5m/5ft) connects UDM Sensor Unit to ARRIFLEX 435 Advanced/Xtreme or ARRIFLEX 416 PLUS
K2.65144.0 Cable UDM-UMC-3 ((1,5m/5ft)) connects UDM Sensor Unit to UMC-3/AUX
K2.65261.0 Cable UDM-ALEXA ((1,5m/5ft)) connects UDM Sensor Unit to ALEXA/EXT
K2.65240.0 Cable UDM-RS ((1,5m/5ft)) connects UDM Sensor Unit to ARRI-RS connector
K2.65262.0 Cable UDM-PSC ((0,7m/2.5ft)) connects UDM Sensor Unit to PSC cables
PSC Cables
ARRI order no. Description Length connects to Function K2.65206.0 PSC-XLR3 1,5m/5ft 24volts battery Power supply only K2.65207.0 PSC-XLR4 1,5m/5ft 12volts battery Power supply only K2.65208.0 PSC-DTAP 0,6m/2ft Anton Bauer D-Tap socket Power supply only K2.65209.0 PSC-HI12 0,6m/2ft Hirose 12pin socket Power supply only K2.65210.0 PSC-FI11 0,6m/2ft ARRIFLEX 435, SONY FF35 Power supply only K2.65211.0 PSC-RS 0,6m/2ft ARRI RS socket Power supply only K2.65212.0 PSC-FI2 1,5m/5ft ARRI OBB-2 battery Power supply only K2.65213.0 PSC-LCS 0,6m/2ft ARRI LCS bus Power supply only
General Description
Page 10
Setup
10
4. Setup
4.1. Standard Setup -
Fasten the UDM units in convenient places on or around the camera using the 3/8” support on both units. Connect the Display to the Sensor Unit using the blue labeled cable. Choose the applicable supply cable either for ALEXA , ARRICAM, camera or the optionally available UMC-3 cable. You may create custom supply cables at your own risk. Refer to chapter 6 for detailed information.
ARRIFLEX 435 / 435Advanced / 435Xtreme / 416 / 235
4.2. LCS Setup -
Using suitable cameras and accessories, the UDM provides the operator with actual Depth-of-Field information on the LDD-FP and controls automatic focus tracking when required. The UDM sends the distance information repeatedly in a serial data stream to the connected unit. Applicable units are ARRI cameras providing a LDD connector and built-in lens motor drives, like the ALEXA Plus, the ARRICAM-ST/LT equipped with a Lens Data Box and an unit incorporating a LDD-FP connector, an ARRIFLEX 435 Advanced/Xtreme with FEM-2 or an ARRIFLEX 416 plus. Alternatively a UMC-3 will also interface the UDM data to an LDD-FP in non-ARRI set-ups (e.g. video camera usage). As the LDD-FP provides the complete UDM information, the Display Unit may be disconnected after parameters have been
Distance measurement only
Depth-of-Field Display and Focus Tracking
set.
Applicable Cameras and Accessories
Cameras
- ARRICAM Studio, Studio Lens Data Box, Studio Readout
- ARRICAM Lite, Lite Lens Data Box, Lite Frame Glow or Remote Control Station with cable KC 65 or KC 69
- ARRIFLEX 435Advanced/Xtreme, FEM-2
- ARRIFLEX 416plus
- UMC-3, LDD-FP with Lens Table stored in Lens Data Archive
- ALEXA and ALEXA Plus
Cable Control
- LCS-bus cable LC-Z1/LC-Z2/LC-M1/LC-M2
- WHA-3 + WFU-1/3
- CLM-2
Metering
- LDD-FP with Cable LDD-RDO K2.54172.0
Wireless Control
- WMU-3, WFU-3, WEB-3, WBU-3/-4, LDD-FP
Always use the latest Camera- and UMC-3 software packets for secure operation.
Page 11
5. Operation of the UDM
5.1 Switching on
The UDM has no dedicated power-switch. Power-on the UDM by using the power switch of the connected supply source (Camera/UMC-3) or connect the appropriate UDM cable to the supply unit.
5.2 Controls and Status LEDs
The blue Control Wheel is used for configuration setup. Push to select and turn to change values.
The Toggle Switch changes the unit of measurement between Metres and centimetres and Feet and inches.
SENSE LED: steady green shows successful measurement FILM PLANE LED: yellow blinking indicates film plane
offset adjustment mode SENSTIVITY LED: yellow blinking indicates sensitivity adjustment mode LIMIT LEDs: yellow blinking indicates value setting mode, steady light indicates limits set to other than maximum (default) value. LDS-DOF LED: steady light indicates the object as being within the calculated Depth-of-Field range, blinking indicates the object to being outside of the Depth-of-Field range. No light indicates, that no camera Depth-of-Field signal is available.
Operation
11
Page 12
5.3 Operation Settings
During operation the following changes or adjustments are available:
Selection of the unit of distance measurement
Operation
Use the toggle switch to select either m/cm or ft/in
Setting of sensitivity Press the control wheel briefly - the SENSITIVITY LED starts blinking, indicating the device is in sensitivity mode. Turn the control wheel and set the new sensitivity value. The value range starts at 0 (OFF) and ends at 100 (MAX). Adjust so that you achieve a steady green SENSE light in the desired measurement range. Press the control wheel briefly again to return to normal operation.
Setting of Film Plane offset
When the Sensor Unit is not mounted on the film plane, the Film Plane offset will need to be recalibrated. Measure the distance between the film plane and the object. Press and hold the Control Wheel for about
1.5sec, until the FILM-PLANE LED starts blinking. Turn the Control Wheel until the correct distance is displayed. Press the Control Wheel briefly again to return to normal operation.
12
5.4 Parameter Settings
Enter the parameter setting mode by pressing and holding the Control Wheel during power-on. Scroll through parameter settings by repeatedly pressing the control knob briefly. The following settings are available:
Display backlight brightness
Default value: L 100 settings from 0 to 200
LOWER LIMIT display range (Lower LIMIT LED blinking) Default value: 0.00 m / 0 ft 0 in settings from 0 to 15.00 m / 49ft 2in
UPPER LIMIT display range (Upper LIMIT LED blinking) Default value: 15.00 m / 49ft 2in settings from 15.00 m / 49ft 2in to 0
Display Resolution ­Default value: r 0 settings from 0 to 5
Default Reset
Default value d no stores user set parameters dEF resets to default values
Press and hold the Control Wheel to return to normal operation.
step width of least significant digit
the
Page 13
5.5 Depth-of-Field and Focus Tracking
Using the settings and accessories described in chapter
4.2, the UDM uses the LDD-FP or the WRC-2 with LDD-FP software option as a display for the actual Depth-of-Field. As the LDD-FP provides the complete UDM information, the UDM Display Unit may be disconnected after parameters have been set.
Indicators on the LDD-FP show the following: An active UDM (or CTM), the measured distance and actual Depth-of-Field. Depth-of-Field is shown graphically as a bar graph and is also displayed as numeric value.
In a cabled configuration the Focus Tracking function can be activated by pressing and holding the blue tracking button on the left side of the WHA-3.
Using the wireless setup, press and hold the BRIGHT - UP button on the LDD-FP. As long the button is kept pressed, the focus motor will follow the measured distance.
Operation
Typical LDD-FP image, indicating
- UDM (CTM) active
- measured distance green dart and numeric value
- Depth-of-Field bar-graph and numeric value
13
Page 14
6. Specifications
Operating temperature
-20 to +50 °C (-4 to +122 °F)
Operating voltage 10 to 30 V DC (12/24V nominal) ARRICAM compatible
Specifications
Typ. current consumption
0,024A (24V) / 0,040A (12V)
Dimensions (h * w * d) with connector Display Unit: 83 * 75 * 32 mm
3.3 * 2.9 * 1.3 in Sensor Unit: 73 * 74 * 91 mm
2.9 * 2.9 * 3.6 in
Weights
Display Unit: 140 g (5 oz) Sensor Unit: 120 g (4.2 oz)
Power connections pin1 GND pin4 +Vbat suitable connector: ARRI order no. 05.21182.0
LEMO FHJ.0B.304.CYMD52Z or equivalent
14
Declaration of Conformity
ARRI CINE + VIDEO GERÄTE GmbH
DIN EN 55011: 2003-08 (Group1/ClassB)
Date: Signature 2007-05-27
Ing. Walter Trauninger
Class A Statement:
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful inter­ference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
We, Manufacturer
Pottendorferstrasse 25-27/3/2/1
A-1120 Wien
declare that the product
Ultrasonic Distance Measure
UDM-1
is in conformity with
DIN EN 61326-1: 2006-10
DIN EN61000-4-2: 2001-12 DIN EN61000-4-3: 2003-11 DIN EN61000-4-4: 2002-07
These limits are designed to provide
Page 15
ARRI Service
15
Page 16
technical data is subject to change without notice
© ARRI 2013
UDM User Manual
ARRI Order no. K5.65999.0
ARNOLD & RICHTER CINE TECHNIK
Türkenstr. 89 D-80799 München Phone +49 (0)89 - 3809-0 Fax +49 (0)89 - 3809-1244 www.arri.com