Warranty
Instructions 120mm x 120mm B&W CPIN002980
Arlec guarantees this product in accordance with the
Australian Consumer Law.
Arlec also warrants to the original first purchaser of this
product (“you”) from a retailer that this product will
be free of defects in materials and workmanship for a
period of 12 months from the date of purchase; provided
the product is not used or installed other than for the
purpose, or in a manner not within the scope of the
recommendations and limitations, specified by Arlec, is
new and not damaged at the time of purchase, has been
properly installed by a licensed electrician or contractor
who is licensed to install electrical products in the place
in which the product was installed and in accordance
with Arlec’s installation instructions, has been maintained
in accordance with the recommendations specified by
Arlec, has not been subjected to abuse, misuse, neglect
or damage, has not been modified or repaired without
the approval of Arlec and has not been used for, or
installed in premises which are used for, commercial
purposes (“Warranty”).
If you wish to claim on the Warranty, you must, at your
own expense, return the product or that part of the
product which you believe is defective in materials and
workmanship, and provide proof of original purchase,
your name, address and telephone number and a
certificate of installation or other document required by
law for the installation of electrical products in the place
in which the product was installed issued by the licensed
electrician or contractor who installed the product, to
Arlec at the address below within 12 months from the
date of purchase. Please note that the Warranty does
not cover removal or re-installation of the product or that
part of the product which you believe is defective.
Arlec will assess any claim you may make on the
Warranty in the above manner and if, in Arlec’s
reasonable opinion, the Warranty applies, Arlec will at its
own option and expense replace the product (or part of
the product) with the same or similar product (or part of
the product) or repair the product (or part of the product)
and return it to you or refund the price you paid for
the product. Arlec will bear its own expenses of doing
those things, and you must bear any other expenses of
claiming on the Warranty.
The Warranty is in addition to other rights and remedies
you may have under a law in relation to the product to
which the Warranty relates.
Our goods come with guarantees that cannot be
excluded under the Australian Consumer Law.
You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have
the goods repaired or replaced if the goods fail to be of
acceptable quality and the failure does not amount to a
major failure.
Arlec Australia Pty. Ltd.
ACN 009 322 105 (“Arlec”) gives the Warranty.
Arlec’s telephone number, address
and email address are:
Customer Service:
New Zealand Toll Free: 0800 003 329
Building 3, 31 – 41 Joseph Street,
Blackburn North, Victoria, 3130
Blackburn North LPO, P.O. Box 1065,
Blackburn North, 3130
Email: custservice@arlec.com.au
(03) 9982 5111
CPIN002980
LED Gimbal
Downlight Kit
INSTRUCTIONS
5W
ALD031 • ALD032 • ALD033 • ALD034
Instructions 120mm x 120mm B&W CPIN002980
Installation Information
WARNING!
Please ensure the following safety warnings are observed:
• This product complies with AS/NZS
60598.2.2 recessed luminaire requirements,
where suitable building insulation may
abut the dowlight [but not cover it).
• This product is suitable for use with
building insulation that can safely be
continually exposed to temperatures up to
90°C and withstand a 30s needle flame test
carried out in accordance with
AS/NZS 60695.11.5 with the ame applied
to all surfaces of the insulation.
• Loose ll insulation as dened in NZS
4246 is not permitted to abut or cover this
luminaire [including the driver].
• Glass bre insulation is a suitable
insulation for use abutting this luminaire.
• Read the instructions prior to installation or
use. Please retain the instructions for future
reference.
• Before attempting to install or maintain,
ensure the power is switched OFF.
• Installation in circuits protected by safety
switches (Earth leakage circuit breakers) is
recommended.
• Use only on rated voltage, otherwise
damage may occur.
• Do not allow the xture to come into
contact with liquids.
• Ensure the xture is fully assembled before
energizing.
• There are no user replaceable components
in this xture.
• Not suitable for use near ammable
liquids, vapour, gases or in explosive
environments.
• If the supply cord is damaged it must only
be replaced by the service agent or similar
qualied person in order to avoid a hazard.
Complies with AS/NZS 60598.2.2
Insula ting Ceiling C A80ºC Ma rk
refer to inst allatio n inform ation
This luminaire is suitable for permanent
installation indoors. The mounting must
be in a rigid and dry location.
1. Ensure the power to the circuit being
connected to is isolated.
2. Remove xture from carton and remove
all packing materials.
3. Select a suitable mounting position.
4. Allow a minimum clearance of 40mm
between the lamp (top and sides) and
adjacent structural members and
building elements.
5. Cut a 92mm diameter hole in
mounting surface.
6. Wire to supply in accordance with
markings on terminals.
7. Feed the supply lead and downlight
through the hole.
8. Carefully lift the retaining clips and
secure the lamp into position.
9. Energise the circuit and check that the
lamp operates.
10. Dispose of any packaging material.
Combustible building element above fitting.
MIC >
50mm
HCB > 25mm
LED DRIVER
SCB > 25mm
Thermal
Insulation
Ceiling
Joist
RISK OF FIRE
Building insulation must not
SCB > 40mm HCB > 10mm MIC>50mm
SCB
of the recessed luminaire and any building
element as specied in AS/NZS 3000 or as
specied by the luminaire manufacturer.
HCB = Minimum distance as specied by the
luminaire manufacturer between the top of
the recessed luminaire and any building
element above it.
MIC = Minimum distance as specied by
the luminaire manufacturer between the top
of any building insulation and the building
element above it.
cover this luminaire
= Minimum distance between the side
92mm Cutout
Ø103mm