Arista DCS-7050QX-32S, DCS-7280SE-64, DCS-7050TX-72, DCS-7050SX-64, DCS-7050SX-72 Quick Start Manual

...
Page 1
Quick Start Guide
7000 Series 1 RU – Gen 3
Data Center Switches
(Tool-less)
DCS-7050QX-32S DCS-7050TX-72 DCS-7050SX-64 DCS-7050TX-96 DCS-7050SX-72 DCS-7280SE-64 DCS-7050SX-96 DCS-7280SE-68 DCS-7050TX-48 DCS-7280SE-72 DCS-7050TX-64
Arista Networks
www.arista.com
PDOC-00041-07
Page 2
Headquarters
Support
Sales
5453 Great America Parkway Santa Clara, CA 95054 USA
408 547-5500
www.arista.com
408 547-5502 866 476-0000
support@arista.com
408 547-5501 866 497-0000
sales@arista.com
© Copyright 2015 Arista Networks, Inc. The information contained herein is subject to change without notice. Arista Networks and the Arista logo are trademarks of Arista Networks, Inc in the United States and other countries. Other product or service names may be trademarks or service marks of others.
Page 3
Chapter 1: Overview
Chapter 1 Overview
1.1 Scope
This guide is intended for properly trained service personnel and technicians who need to install the following Arista Networks Data Center Switches:
DCS-7050QX-32S DCS-7050TX-48 DCS-7280SE-64
DCS-7050SX-64 DCS-7050TX-64 DCS-7280SE-68
DCS-7050SX-72 DCS-7050TX-72 DCS-7280SE-72
DCS-7050SX-96 DCS-7050TX-96
Important! Only qualified personnel should install, service, or replace this equipment.
1.2 Receiving and Inspecting the Equipment
Upon receiving the switch, inspect the shipping boxes and record any external damage. Retain packing materials if you suspect that part of the shipment is damaged; the carrier may need to inspect them.
If the boxes were not damaged in transit, unpack them carefully. Ensure that you do not discard any accessories that may be packaged in the same box as the main unit.
Inspect the packing list and confirm that you received all listed items. Compare the packing list with your purchase order. Appendix B provides a list of components included with the switch.
1.3 Installation Process
The following tasks are required to install and use the switch:
Step 1 Select and prepare the installation site (Section 2.1). Step 2 Assemble the installation tools listed in Section 2.2. Step 3 Attach the mounting brackets and install the switch in an equipment rack (Chapter 3). Step 4 Connect the switch to the power source and network devices (Chapter 4). Step 5 Configure the switch (Chapter 5).
Important! Class 1 Laser Product: This product has provisions to install Class 1 laser transceivers which provide
optical coupling to the communication network. Once a Class 1 laser product is installed, the equipment is a Class 1 Laser Product (Appareil à Laser de Classe 1). The customer is responsible for selecting and installing the Class 1 laser transceiver and for insuring that the Class 1 AEL (Allowable Emission Limit) per EN/IEC 6-825, CSA E60825-1, and Code of Federal Regulations 21 CFR 1040 is not exceeded after the laser transceiver have been installed. Do not install laser products whose class rating is greater than 1. Refer to all safety instructions that accompanied the transceiver prior to installation. Only Class 1 laser devices, certified for use in the country of installation by the cognizant agency are to be utilized in this product.
Important! Ultimate disposal of this product should be in accordance with all applicable laws and regulations.
1.4 Safety Information
Refer to the Arista Networks document Safety Information and Translated Safety Warnings available at:
http://www.arista.com/en/support/docs/eos
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 3
Page 4
1.5 Obtaining Technical Assistance
Any customer, partner, reseller or distributor holding a valid Arista Service Contract can obtain technical support in any of the following ways:
Email: support@arista.com. This is the easiest way to create a new service request.
Include a detailed description of the problem and the output of “show tech-support”.
Chapter 1: Overview
Web: www.arista.com/en/support
.
A support case may be created through the support portal on our website. You may also download the most current software and documentation, as well as view FAQs, Knowledge Base articles, Security Advisories, and Field Notices.
Phone: 866-476-0000 or 408-547-5502.
Important! No user serviceable parts inside. Refer all servicing to qualified service personnel.
1.6 Specifications
Ta b l e 1 lists the specifications of Arista Data Center switches covered by this guide.
Table 1: Switch Specifications
Size (W x H x D) DCS-7050QX-32S
DCS-7050SX-64, -72. -96 DCS-7050TX-48, -64 DCS-7050TX -72, -96 DCS-7280SE-64, -68, -72
Weight DCS-7050QX-32S
DCS-7050SX-64 DCS-7050SX-72 DCS-7050SX-96 DCS-7050TX-48 DCS-7050TX-64 DCS-7050TX-72 DCS-7050TX-96 DCS-7280SE-64 DCS-7280SE-68 DCS-7280SE-72
Operating Temperature Storage Temperature Operating Altitude Relative Humidity
Power Input (AC Power) all switches 100 - 240 VAC, 6.5 - 3.0 A, 50/60 Hz
Power Draw
(Typical / Maximum)
all switches all switches all switches all switches
DCS-7050QX-32S DCS-7050SX-64 DCS-7050SX-72 DCS-7050SX-96 DCS-7050TX-48 DCS-7050TX-64 DCS-7050TX-72 DCS-7050TX-96 DCS-7280SE-64 DCS-7280SE-68 DCS-7280SE-72
44.5 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches)
44.5 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches)
44.5 x 4.4 x 40.6 cm (19 x 1.75 x 16 inches)
44.5 x 4.4 x 52.3 cm (19 x 1.75 x 20.6 inches)
44.5 x 4.4 x 52.3 cm (19 x 1.75 x 20.6 inches)
9.1 kg (20 pounds)
8.6 kg (19 pounds)
8.6 kg (19 pounds)
9.1 kg (20 pounds)
7.7 kg (17 pounds)
8.6 kg (19 pounds)
10.0 kg (22 pounds)
10.5 kg (22 pounds)
10.0 kg (22 pounds)
10.1 kg (22 pounds)
10.2 kg (22 pounds)
0° to 40° C (32° to 104° F)
-25° to 70° C (-13° to 158° F) 0 to 3,000 meters (0 to 10,000 feet) 5 to 90%
150 W / 300 W 140 W / 220 W 144 W / 276 W 159 W / 290 W 305 W / 367 W 315 W / 387 W 349 W / 440 W 355 W / 455 W 263 W / 381 W 313 W / 405 W 262 W / 399 W
4 Arista Networks Copyright 2014
Page 5
Chapter 2: Preparation
MAC ADDRESS
II IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
I
SERIAL NUMBER
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
ASSEMBLY NUMBER
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
Fan Module
Handle
Module 1
Airflow Direction
Power Supply
Module 1
Airflow Direction
Power Supply
Module 2
Fan Module
Handle
Module 2
Fan Module
Handle
Module 3
Fan Module
Handle
Module 4
Chapter 2 Preparation
2.1 Site Selection
The following criteria should be considered when selecting a site to install the switch:
Temperature and Ventilation: For proper ventilation, install the switch where there is ample airflow to the front and back of the switch. The ambient temperature should not go below 0° or exceed 40° C.
Important! To prevent the switch from overheating, do not operate it in an area where the ambient temperature
exceeds 40°C (104°F).
Airflow Orientation: Determine airflow direction of the four fan modules and two power supply modules on the rear panel. Fan and power supply module handles indicate airflow direction:
Blue Handle: Air Inlet module.Red Handle: Air Exit module.
Figure 1 displays fan and power supply module locations on the rear panel. Their red handles
indicate that they are air exit modules. Verify that each module has the same airflow direction. Base the switch orientation on the airflow direction of the modules to assure the air inlet is always oriented toward the cool aisle:
Air Exit modules: orient the rear panel toward the hot aisle. — Air Inlet modules: orient the rear panel toward the cool aisle.
If the airflow direction is not compatible with the installation site, contact your sales representative to obtain modules that circulate air in the opposite direction.
Figure 1: Airflow Direction Labels
Rack Space: Install the switch in a 19" rack or cabinet. The switch height is 1 RU. The accessory kit provides mounting brackets for two-post and four-post racks.
When mounting the switch in a partially filled rack, load the rack from bottom to top, with the heaviest equipment at the bottom. Load the switch at the bottom if it is the only item in the rack.
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 5
Page 6
Chapter 2: Preparation
Power Requirements: Power requirements vary by switch and power supply model. Refer to
Ta b l e 1 for information regarding your specific system.
Two circuits provide redundancy protection. Section 4.2 describes power cable requirements.
Important! The power input plug-socket combination must be accessible at all times; it provides the primary
method of disconnecting power from the system.
Other Requirements: Select a site where liquids or objects cannot fall onto the equipment and foreign objects are not drawn into the ventilation holes. Verify these guidelines are met:
— Clearance areas to the front and rear panels allow for unrestricted cabling. — All front and rear panel indicators can be easily read. — Power cords can reach from the power outlet to the connector on the rear panel.
Important! All power connections must be removed to de-energize the unit.
2.2 Tools Required for Installation
Each switch provides an accessory kit that contains parts that are required to install the switch. In addition to the accessory kit, the following tools and equipment are required to install the switch:
Two - Po st R ac k
Screws or rack mounting nuts and bolts.
Screwdriver
Four-Post Rack (Toolless)
No additional equipment required.
Four-Post Rack (Conventional)
Screws or rack mounting nuts and bolts.
Screwdriver
Accessory kit does not include screws for attaching the switch to the equipment rack. When installing the switch into an equipment rack with unthreaded post holes, nuts are also required to secure the switch to the rack posts.
2.3 Electrostatic Discharge (ESD) Precautions
Observe these guidelines to avoid ESD damage when installing or servicing the switch.
Assemble or disassemble equipment only in a static-free work area.
Use a conductive work surface (such as an antistatic mat) to dissipate static charge.
Wear a conductive wrist strap to dissipate static charge accumulation.
Minimize handling of assemblies and components.
Keep replacement parts in their original static-free packaging.
Remove all plastic, foam, vinyl, paper, and other static-generating materials from the work area.
Use tools that do not create ESD.
6 Arista Networks Copyright 2014
Page 7
Chapter 3: Rack Mounting the Switch
Rear mount
Front mount
Center mount
Front bracket hole does not lock into pin
Rear bracket hole does not lock into pin
Chapter 3 Rack Mounting the Switch
Important! The rack mounting procedure is identical for all switches covered by this guide. Illustrations in this
chapter depict the mounting of a DCS-7050QX-32S switch.
Section 3.1 provides instructions for mounting the switch in a two-post rack.
Section 3.2 provides instructions for mounting the switch in a four-post rack.
After completing the instructions for your rack type, proceed to Chapter 4: Cabling the Switch.
3.1 Two-Post Rack Mount
To mount the switch onto a two-post rack, assemble the mounting brackets to the chassis, then attach the brackets to the rack posts. Two-post accessory kits include the following two-post mounting parts:
2 three-hole mounting brackets
Each chassis side has attachment pins that align with bracket holes. Pin orientation is symmetric and equidistant, supporing bracket placements where the flange is flush the front switch panel, flush with the rear panel, or not flush with either panel. Each bracket hole includes a key-opening for placing the bracket flush with the chassis and then locking it into place.
Important! Attachment pins must be lock all three upper bracket holes.
Figure 2 displays proper bracket mount configuration examples.
Figure 2: Bracket Mount Examples for Two-Post Rack Mount
Figure 3 displays improper bracket mount configuration examples.
Figure 3: Improper Bracket Mount Examples for Two-Post Rack Mount
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 7
Page 8
3.1.1 Attaching Mounting Brackets to the Chassis
Attaching the brackets: Front mount
Bracket Clip
Step 3
Bracket Clip
Step 2
Step 1
This procedure attaches mounting brackets to the switch chassis (Figure 4).
Step 1 Align the mounting brackets with the attachment pins to obtain the desired mounting position. Step 2 Place the bracket flush on the chassis with attachment pins protruding through key-openings. Step 3 Slide the bracket toward the front flange until the bracket clip locks with an audible click.
Figure 4: Attaching the Mounting Brackets to the Switch Chassis
To remove the mounting bracket from the chassis, lift the front edge of the mounting bracket clip with a flathead screwdriver and slide the bracket away from the front flange (opposite from the installation direction).
Chapter 3: Rack Mounting the Switch
3.1.2 Inserting the Switch into the Rack
This procedure attaches the switch to the rack (Figure 5).
Step 1 Lift the chassis into the rack. Position the flanges against the rack posts.
Figure 5: Inserting the Switch into the Rack
Step 2 Select mounting screws that fit your equipment rack. Step 3 Attach the bracket flanges to the rack posts.
After completing the two-post rack mount, proceed to Chapter 4: Cabling the Switch.
8 Arista Networks Copyright 2014
Page 9
Chapter 3: Rack Mounting the Switch
Front mount
Off-set mount
Rear mount
Bracket not attached by at least 5 pins
3.2 Four-Post Rack Mount
The switch is mounted onto a four-post rack by assembling two rails onto the rear posts, sliding the switch onto the rails, then securing the switch to the front posts.
The installation kit provides the following four-post mounting parts:
2 six-hole mounting brackets
2 rail-rods
2 rail-slides
The rail-rods and rail-slides assemble into two identical slide-rails.
Each chassis side has attachment pins that align with bracket holes. Pin orientation is symmetric and equidistant, supporting bracket placements where the flange is flush the front switch panel, flush with the rear panel, or not flush with either panel. Each bracket hole includes a key-opening for placing the bracket flush with the chassis and then locking it into place.
Important! Attachment pins must be lock at least five of the six bracket holes.
Figure 6 displays proper bracket mount configuration examples.
Figure 6: Bracket Mount Examples for Four-Post Rack Mount
Figure 7 displays an improper bracket mount configuration example.
Figure 7: Improper Bracket Mount Example for Four-Post Rack Mount
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 9
Page 10
3.2.1 Attaching Mounting Brackets to the Chassis
Attaching the brackets: Front mount
Bracket Clip
Step 3
Bracket Clip
Step 2
Step 1
Figure 8 displays the front bracket alignment for mounting the switch into a four-post rack.
Figure 8: Attaching the Mounting Brackets to the Switch Chassis
This procedure attaches mounting brackets to the switch chassis as depicted by Figure 9.
Chapter 3: Rack Mounting the Switch
Step 1 Align the mounting brackets with the attachment pins to obtain the desired mounting position. Step 2 Place the bracket flush on the chassis with attachment pins protruding through key-openings. Step 3 Slide the bracket toward the front flange until the bracket clip locks with an audible click.
Figure 9: Attaching the Mounting Brackets to the Switch Chassis
To remove the mounting bracket from the chassis, lift the front edge of the mounting bracket clip with a flathead screwdriver and slide the bracket away from the front flange (opposite from the installation direction).
10 Arista Networks Copyright 2014
Page 11
Chapter 3: Rack Mounting the Switch
Inset A
Inset A
Rack Plugs
Rail (assembled)
Rail-Rod
Rail-Slide
Inset A
Inset A
Inset B
Inset B
3.2.2 Assembling the Rails onto the Equipment Rack
Rail-rods and rail-slides assemble into two identical rails. Each rail connects a front post to a rear post. When the rails are installed, the switch slides on the rails into the rack. Each bracket includes a screw that attaches the switch to the rail.
Each end of an assembled rail contains two rack plugs (Figure 10, inset A). The rails are installed into a rack by inserting the plugs into rack slots. When installing rails into posts with threaded or rounded holes, remove all plugs located on both sides of the assembled rails, then install the rails with bolts that fit the rack.
This procedure attaches the rails to a four post rack:
Step 1 Slide a rail-rod into a rail-slide (Figure 10) until the rail clip makes an audible click.
The rail clip prevents the extension of the rail beyond the maximum supported distance between the front and rear rack posts.
Figure 10: Assembling the Rails
Step 2 Attach rail to the right rear rack post by inserting rod-end rack plugs into post slots (Figure 11,
inset A). The slide assembly must be inside the right posts, relative to the left rack posts.
If the rack plugs were previously removed, use bolts to attach the rail to the rack.
Step 3 Attach the slide end of the rail to the front post by extending the rail end past the post, then
contracting the rail while guiding the rack plugs into the post (Figure 11, inset B).
Step 4 Repeat step 1 through step 3 for the left posts. Ensure the rails are on the same horizontal level.
Figure 11: Attaching the Rails
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 11
Page 12
3.2.3 Attaching the Switch to the Rack
After the rails are installed, the switch slides on the rails into the rack. Each bracket includes a thumb screw that attaches the switch to the rail
Step 1 Lift the switch into the rack and insert the mounting brackets into the slide rails.
Chapter 3: Rack Mounting the Switch
Figure 12: Inserting the Switch onto the Rails
Step 2 Slide the switch on the rails, toward the rear posts, until the mounting bracket flanges are flush
with the rail flanges attached to the rack posts.
Step 3 Attach the bracket flanges to the rack post using the quick-release thumb screws supplied with
the brackets.
Figure 13: Attaching the Switch to the Rack Posts
After completing the four-post rack mount, proceed to Chapter 4: Cabling the Switch.
12 Arista Networks Copyright 2014
Page 13
Chapter 4: Cabling the Switch
MAC ADDRESS
II IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
I
SERIAL NUMBER
IIIIIIIIIIIIIIIIIIIIIIIIIIIII
IIIIII
ASSEMBLY NUMBER
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
Earth Grounding Pads
Chapter 4 Cabling the Switch
4.1 Grounding the Switch
After mounting the switch into the rack, connect the switch to the data center ground. Figure 14 displays the location of the grounding pads located on the bottom corners of the front panel.
Important! Grounding wires and grounding lugs (M4 x 0.7) are not supplied. Wire size should meet local and
national installation requirements. Commercially available 6 AWG wire is recommended for installations in the U.S.
Figure 14: Earth Grounding Pad Sockets
4.2 Connecting Power Cables
Important! Installation of this equipment must comply with local and national electrical codes. If necessary, consult
with the appropriate regulatory agencies and inspection authorities to ensure compliance.
The switch operates with two installed power supplies. At least one power supply must connect to a power source. Two circuits provide redundancy protection. Appendix D displays the location of the power supplies on the rear panel of the switch.
Important! Read all installation instructions before connecting the system to the power source.
Non-Redundant Configuration: Connect power to either of the two power supplies.
Redundant Power Supply Configuration: Connect power to both power supplies.
Power down the Switch: Remove all power cords and wires from the power supplies.
Important! This equipment must be grounded. Never defeat the ground conductor.
Important! This unit requires overcurrent protection.
Figure 15 displays an AC power supply, including the power socket on the left side of the module. The
AC power supply connects to a circuit that provides the required power, as specified by Ta b l e 1 .
Figure 15: AC Power Supply
The power supplies require power cables that comply with IEC-320 and have a C13 plug. The accessory kit provides two IEC-320 C13 to C14 power cables.
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 13
Page 14
4.3 Connecting Serial and Management Cables
USB Port
Console (Serial) Port
Ethernet Management Port
The accessory kit includes the following cables:
RJ-45 to DB-9 serial adapter cable.
RJ-45 Ethernet cable.
Ta b l e 2 lists the pin connections of the RJ-45 to DB-9 adapter cable.
Table 2: RJ-45 to DB-9 Connections
RJ-45 DB-9 RJ-45 DB-9
RTS 18CTS GND 55GND
DTR 26DSR
TXD 32RXD DSR 74DTR
GND 45GND CTS 87RTS
The front panel contains the console, management, and USB ports. Figure 16 displays the ports on the DCS-7050QX-32S switch. Appendix C displays the front panel of all switches covered by this guide.
RXD 63TXD
Chapter 4: Cabling the Switch
Caution Excessive bending can damage interface cables, especially optical cables.
Figure 16: Front Panel Ports
Connect the front panel ports as follows:
Console (Serial) Port: Connect to a PC with the RJ-45 to DB-9 serial adapter cable. The switch uses the following default settings:
— 9600 baud — No flow control —1 stop bit —No parity bits — 8 data bits
Ethernet Management Port: Connect to 10/100/1000 management network with RJ-45 Ethernet cable.
USB Port: The USB port may be used for software or configuration updates.
14 Arista Networks Copyright 2014
Page 15
Chapter 5: Configuring the Switch
Chapter 5 Configuring the Switch
Arista switches ship from the factory in Zero Touch Provisioning (ZTP) mode. ZTP configures the switch without user intervention by downloading a startup configuration file or a boot script from a location specified by a DHCP server. To manually configure a switch, ZTP is bypassed. The initial configuration provides one username (admin) accessible only through the console port because it has no password.
When bypassing ZTP, initial switch access requires logging in as admin, with no password, through the console port. Then you can configure an admin password and other password protected usernames.
This manual configuration procedure cancels ZTP mode, logs into the switch, assigns a password to admin, assigns an IP address to the management port, and defines a default route to a network gateway.
Step 1 Provide power to the switch (Section 4.2).
Step 2 Connect the console port to a PC (Section 4.3).
As the switch boots without a startup-config file, it displays the following through the console:
The device is in Zero Touch Provisioning mode and is attempting to download the startup-config from a remote system. The device will not be fully functional until either a valid startup-config is downloaded from a remote system or Zero Touch Provisioning is cancelled. To cancel Zero Touch Provisioning, login as admin and type 'zerotouch cancel' at the CLI.
localhost login:
Step 3 Log into the switch by typing admin at the login prompt.
localhost login:admin
Step 4 Cancel ZTP mode by typing zerotouch cancel. IMPORTANT: This step initiates a switch reboot.
localhost>zerotouch cancel
Step 5 After the switch boots, log into the switch again by typing admin at the login prompt.
Arista EOS localhost login:admin Last login: Fri Mar 15 13:17:13 on console
Step 6 Enter global configuration mode.
localhost>enable localhost#config
Step 7 Assign a password to the admin username with the username secret command.
localhost(config)#username admin secret pxq123
Step 8 Configure a default route to the network gateway.
localhost(config)#ip route 0.0.0.0/0 192.0.2.1
Step 9 Assign an IP address (192.0.2.8/24 in this example) to an Ethernet management port.
localhost(config)#interface management 1 localhost(config-if-Ma1/1)#ip address 192.0.2.8/24
Step 10 Save the configuration by typing write memory or copy running-config startup-config.
localhost#copy running-config startup-config
When the management port IP address is configured, use this command to access the switch from a host, using the address configured in step 9:
ssh admin@192.0.2.8
Refer to the Arista Networks User Manual for complete switch configuration information.
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 15
Page 16
Chapter 5: Configuring the Switch
16 Arista Networks Copyright 2014
Page 17
Appendix A: Status Indicators
System Status LED Fan Status LED Power Supply 1 Status LED Power Supply 2 Status LED
Appendix A Status Indicators
A.1 Front Indicators
A.1.1 Switch Indicators
Front panel LEDs are located on the right side of the chassis and display system, fan, and power supply status. Appendix C displays the front panels of all switches covered by this guide.
Figure 17 displays the DCS-7050QX-32S front panel LEDs.
Figure 17: System Status Indicators
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 17
Page 18
Table 3: Switch Indicators LED States
LED Name LED State Device Status
Blinking Green System powering up.
System Status
Fan Status
PSU [1:2]
Green All power supplies and fans are operating normally.
Blue The locator function is active.
Red A power supply or fan is missing or in a failed state.
Green All fans are operating normally.
Red One or more fans are not inserted or have failed.
Green PSU functioning and fully operational. AC present, Aux
output ON, and Main output ON.
Blinking Green Standby mode - Main is turned off, and Aux is on. AC
present, Aux output ON, and Main output turned off.
Blinking Amber Fault of any kind - Electrical, thermal, or fan. This fault can
be due to (high/low) voltage, current, temperature, stuck rotor, faulty cables, or internal damage.
Power supply has AC power but is not plugged in to the chassis.
Off PSU not powered. Power supply plugged in to a live chassis,
with no AC cord.
Appendix A: Status Indicators
Important! For the LED Name “PSU [1:2]” the LED State “Blinking Amber” applies to all “Device Status” states
as described. In order to narrow down the specific condition, you must login to the switch to view the specific device state. Refer to the Arista User Manual’s Switch Environment Control chapter, under the topic Viewing Environment Status, the for further information on the
show environment
commands.
18 Arista Networks Copyright 2014
Page 19
Appendix A: Status Indicators
Port 1 LEDs
Port 2 LEDs
Port 3 LEDs
Port 4 LEDs
A.1.2 Port Indicators
Port LEDs, located in the vicinity of their corresponding ports, provide link and operational status.
Figure 18 displays the Port LED location on the DCS-7050QX-32S switch. Appendix C displays the port
LED locations of all switches covered by this guide.
Figure 18: Port LEDs
Ta bl e 4 provides status co nditions th at correspond to po rt LED state s. Port LE D behavior fo r QSFP+ and
SFP+ ports is consistent.
Table 4: Port LED States
LED State Status
Off Port link is down.
Green Port link is up.
Yellow Port is software disabled.
Flashing Yellow Port failed diagnostics.
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 19
Page 20
A.2 Rear Status Indicators
Fan Status LED
Power Supply Status LED
Fan and power supply modules are accessed from the rear panel. Each fan and power supply module contains an LED that reports the module status. Appendix D displays the rear panel of all switches covered by this guide.
Fan Status LEDs are on the fan modules, as displayed in Figure 19.
Figure 19: Fan Status LED
Ta bl e 5 provides status conditions that correspond to fan status LED states.
Table 5: Fan Status LED States
Appendix A: Status Indicators
LED State Status
Off The fan module is inserted but not receiving power – it may not be properly seated.
Green The fan is operating normally.
Red The fan has failed or a power supply module was removed from the switch.
The Power Supply Status LEDs are on the power supply modules, as displayed in Figure 20.
Figure 20: Power Supply Status LED
Ta bl e 6 provides status conditions that correspond to power supply status LED states.
Table 6: Power Supply Status LED States
LED State Status
Off Power supply not connected to AC power or not inserted fully.
Green Power supply operating normally.
Amber Power supply has overheated or failed.
20 Arista Networks Copyright 2014
Page 21
Appendix B: Parts List
Rail-Slides (2)Rail-Rods (2) Brackets – six hole (2)
Mounting Brackets (Three Hole)
Appendix B Parts List
Each switch provides an accessory kit that contains parts that are required to install the switch. This appendix lists the installation parts contained in the switch accessory kit.
B.1 Rack Mount Parts
B.1.1 Four-Post Rack Mount Parts
Figure 21: Four-Post Rack Mount Parts
B.1.2 Two-Post Rack Mount Parts
Figure 22: Two-Post Rack Mount Parts
B.2 Cables
Table 7: Switch Cables
Quantity Description
2 Power cables: IEC-320/C13-C14, 13 A, 250 V
1 RJ-45 Patch Panel Cable
1 RJ-45 to DB9 Adapter Cable
Wa r ni n g! All provided power cables are for use only with Arista products.
警告 すべての電源コードは提供する製品で使⽤するためだけを⽬的としている。
電源コードの他の製品での使⽤の禁⽌ Arista が提供するすべての電源コードは、Arista の製品でのみ使⽤してください。
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 21
Page 22
Appendix C Front Panel
System Status LED
Fan Tray Status LED
Power Supply 2 Status LED Power Supply 1 Status LED
USB Flash Port
Ethernet Management Port
Console (Serial) Port
11 27 4315 31 4713 29 459 25 417 23 395 21 373 19 351 17 3312 28 4416 32 4814 30 4610 26 428 24 406 22 384 20 362 18 34
System Status LED
Fan Tray Status LED
Power Supply 2 Status LED Power Supply 1 Status LED
USB Flash Port
Ethernet Management Port
Console (Serial) Port
7050SX-72
Power Supply 1 Status LED
Power Supply 2 Status LED
USB Flash Port
Ethernet Management Port
Console (Serial) Port
System Status LED
Fan Tray Status LED
This appendix displays the front panel of all switches covered by this guide.
DCS-7050QX-32S
Figure 23: DCS-7050QX-32S Front Panel
DCS-7050SX-64
Appendix C: Front Panel
Figure 24: DCS-7050SX-64 Front Panel
DCS-7050SX-72
11 151397531121614108642 43 47454139373533 44 48464240383634
Figure 25: DCS-7050SX-72 Front Panel
22 Arista Networks Copyright 2014
27 31292523211917 28 32302624222018
Page 23
Appendix C: Front Panel
7050SX-96
Power Supply 1 Status LED
Power Supply 2 Status LED
USB Flash Port
Ethernet Management Port
Console (Serial) Port
System Status LED
Fan Tray Status LED
35689
02356
333
5
3
8
1920
9303132
7050TX-48
System Status LED
Fan Tray Status LED
Power Supply 2 Status LED Power Supply 1 Status LED
USB Flash Port
Ethernet Management Port
Console (Serial) Port
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
System Status LED
Fan Tray Status LED
Power Supply 2 Status LED Power Supply 1 Status LED
USB Flash Port
Ethernet Management Port
Console (Serial) Port
DCS-7050SX-96
11 151397531121614108642 43 47454139373533 44 48464240383634
Figure 26: DCS-7050SX-96 Front Panel
DCS-7050TX-48
Figure 27: DCS-7050TX-48 Front Panel
27 31292523211917 28 32302624222018
4 3
6
17 1
1
232
25267282
DCS-7050TX-64
Figure 28: DCS-7050TX-64 Front Panel
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 23
Page 24
DCS-7050TX-72
7050TX-72
234
5
678
910
11121314151
61719
20
4
25
26
93031323334363738
3940
414
5
46
4
48
Power Supply 1 Status LED
Power Supply 2 Status LED
USB Flash Port
Ethernet Management Port
Console (Serial) Port
System Status LED
Fan Tray Status LED
7050TX-96
35689
02356
81920
25
26
93031323334353637383940
434546748
Power Supply 1 Status LED
Power Supply 2 Status LED
USB Flash Port
Ethernet Management Port
Console (Serial) Port
System Status LED
Fan Tray Status LED
11 151397531121614108642 43 47454139373533 44 48464240383634
27 31292523211917 28 32302624222018
System Status LED
Fan Tray Status LED
Power Supply 2 Status LED Power Supply 1 Status LED
USB Flash Port
Ethernet Management Port
Console (Serial) Port
Appendix C: Front Panel
1
Figure 29: DCS-7050TX-72 Front Panel
DCS-7050TX-96
1
17 1
Figure 30: DCS-7050TX-96 Front Panel
2122232
21
232
27 282
27 282
1
243444
2
7
DCS-7280SE-64
Figure 31: DCS-7280SE-64 Front Panel
24 Arista Networks Copyright 2014
49 505152
Page 25
Appendix C: Front Panel
11 151397531121614108642 43 47454139373533 44 48464240383634
27 31292523211917 28 32302624222018
System Status LED
Fan Tray Status LED
Power Supply 2 Status LED Power Supply 1 Status LED
USB Flash Port
Ethernet Management Port
Console (Serial) Port
11 151397531121614108642 43 47454139373533 44 48464240383634
27 31292523211917 28 32302624222018
Power Supply 1 Status LED
Power Supply 2 Status LED
USB Flash Port
Ethernet Management Port
Console (Serial) Port
System Status LED
Fan Tray Status LED
DCS-7280SE-68
Figure 32: DCS-7280SE-68 Front Panel
DCS-7280SE-72
Figure 33: DCS-7280SE-72 Front Panel
7000 Series 1 RU – Gen 3 Quick Start Guide PDOC-00041-06 25
Page 26
Appendix D Rear Panel
MAC ADDRESS
II IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
I
SERIAL NUMBER
IIIIIIIIIIIIIIIIIIIIIIIIIIIII
IIIIII
ASSEMBLY NUMBER
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
Earth Grounding
Port
Airflow Direction
Power Supply
Module 1
Airflow Direction
Power Supply
Module 2
Fan Module
Handle
Module 1
Fan Module
Handle
Module 2
Fan Module
Handle
Module 3
Fan Module
Handle
Module 4
This appendix displays the rear panel of all switches covered by this guide.
All Models
Figure 34: Rear Panel
Appendix D: Rear Panel
26 Arista Networks Copyright 2014