* Phone: (856) 626-1550 * Fax: (856) 626-1551 
www.ariesfilterworks.com * ariescs@ariesfilterworks.com   
UNIX 
MODULAR CARTRIDGE HOLDER 
FOR MODEL: 
UNIX-00 

M-0212201104  Page 1 of 4  
Revision 4   
INTRODUCTION 
The UNIX cartridge holder is designed to hold a single VP Style cartridge for water 
purification. The UNIX unit is modular in design to allow the customization or expansion of 
the UNIX system. Multiple units can be used in series or parallel to achieve varying degrees of 
water quality and flow rates. 
The UNIX should be connected to a pressurized water supply between 5 psi and 30 psi. A 
quick connect system allows cartridges to be changed without the use of tools.  
The cartridge seal is made with a spring-loaded plunger assembly with o-ring seals. Best unit 
performance is obtained when the cartridge is run down-flow.  Purified water is dispensed 
through the tube connected to bottom of the unit. 
The UNIX holder comes with the o-rings and tube fittings factory installed. Tubing, a Shut 
Valve, Inlet and Outlet Fittings, and Mounting Screws, are supplied with the unit. The inlet and 
outlet connections must be installed by the user and cut to the desired length. 
WARNINGS 
1. Do not exceed a maximum pressure 30 psi. 
2. Mounting wall must be able to support 25 pounds per unit. 
3. Shut off valve must be installed on the inlet to the UNIX. 
4. Shut off water supply at UNIX Inlet and de-pressurize unit before replacing cartridges 
or servicing the unit. 
5. Improper installation of the unit may case leaks. 

M-0212201104  Page 2 of 4  
Revision 4   
 COMPONENT SYSTEM LIST 
UNIX Unit with Inlet and Outlet Push Fittings 
6 feet, ¼” OD polyethylene tubing 
Shut Off Valve 
Inlet/Outlet Fittings 
2 X Mounting Screws 

M-0212201104  Page 3 of 4  
Revision 4   
NOTE: DETERMINE FLOW DIRECTION 
For color changing cartridges and single bed applications, down flow is 
recommended 
Multi-layer cartridges are configured for upflow. For downflow layered 
cartridges, contact the factory. 
INSTALLATION INSTRUCTIONS 
1. Mount the UNIX to the wall using heavy-duty anchors rated for a minimum of 25 
pounds.  
2. Be sure the unit is straight and level. Improper leveling of the unit can cause poor 
distribution and lead to shortened cartridge life. 
UNIX Inlet Assembly 
3. Connect the Inlet Fitting to ¼” Tubing, as shown above. 
4. Connect the Shut Off Valve to the end of the ¼” Tubing. 
5. Connect the supply tube to the other end of the Shut Off Valve. 
6. Connect the Inlet Fitting to the UNIX Inlet. 
NOTE: TIGHT, LEAK FREE, CONNECTIONS CAN EASLIY BE MADE 
BY PUSHING THE TUBE FIRMLY IN TO THE FITTING.  

M-0212201104  Page 4 of 4  
Revision 4   
7. Connect the remaining ¼” Tube to the Outlet Fitting as shown below. 
UNIX Outlet Assembly 
8. Connect the Outlet Fitting into the UNIX Outlet. 
9. Install cartridge by placing the bottom of the cartridge on top of the plunger, making sure 
the o-ring seats firmly into the inside diameter, and push down. Place the top of the 
cartridge under the upper fitting and allow the cartrtidge to spring up and seal with the 
upper o-ring. Rotate cartridge back and forth ½ turn to insure a good seal between with 
the o-rings. 
10. Open / Close the Shut Off Valve on the UNIX unit to Start / Stop water flow through the 
cartridge. In case of a leak, shut off the water immediately and re-install cartridge. 
VP SERIES REPLACEMENT CARTRIDGES 
High Purity Mixed Bed – Color Changing 
High Capacity Mixed Bed – Color Changing 
Cation Conductivity / Metals – Color Changing