Ariel EZWT2651SOAKERR Installation Manual

Walk-In Bathtubs
Installation Guide
Table of Contents
GENERAL INFORMATION………………………………..Page 1
SAFETY INSTRUCTIONS………………………………... Page 1
A
A
A
r
r
r
i
i
i
e
e
e
l
l
l
ROUGH / DRAWING DIAGRAMS………..………….……...Page 2
GETTING STARTED (1) (2) (3)…………………….……... Page 3
INSTALLATION……………………………………......... Page 4-5
OPERATION GUIDE…………………………….....Page 5
WARRANTY…………………………………………..……Page 6
APPROVAL……………………………………………..Page 7-12
Ariel Walkin Bathtub [ Installation Guide ]
Page 1
GENERAL INFORMATION
SAVE THIS MANUAL: RETAIN FOR CONSUMER USE Read these instructions completely before installing the product: If you have any questions call: (800) 304-3598 You must follow all instruction in this manual: Failure to do so will result in your assumption of liability that may occur. Failure to comply with all instructions can result in product and personal injury. RESPONSIBILITY OF THE INTALLER The installer must inspect and water test the product prior to installation to ensure the unit is free of defect or damage. In the event of a problem, the unit must not be installed. If the crate or product has been damaged please call immediately: (800) 304-3598 This product is designed to be installed by a licensed tradesperson, licensed plumbers and electricians should be employed to insure proper installation. Installers assume all liability for the correct installation procedures. Only accessories authorized by the manufacturer should be used with this product.
SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
1. When using this product, basic precautions should always be followed. Read and follow all instructions pertaining to risk of fire,
electric shock, or injury to persons.
2. Use this unit only for its intended purposes or as described in this manual .Use only attachments recommended by the
manufacturer.
3. Risk of hyperthermia and possible drowning: Water temperature in excess of 100°F (38°C) may be injurious to your health.
Check and adjust temperature before use.
READ AND FOLLOW ALL INSTRUCTIONS
1. Danger: To reduce the risk of injury, do not permit children or persons with infirmities to use this product unless they are closely
supervised at all times.
2. To avoid injury, exercise caution when entering or exiting the tub.
3. Never drop or insert any objects into any openings.
4. Risk of electrical shock; connect only to a separate circuit protected by a ground fault circuit interrupter (GFCI).
5. Warning: Risk of electric shock, do not permit electric appliances (such as a hair dryer, lamp, telephone, radio or television)
within 5-feet (1.5M) of this hydro massage bathtub.
6. This unit must be connected to a circuit interrupter (GFCI) .Such a circuit is provided by the installer and should be tested on a
routine basis. To test the GFCI push the test button, the GFCI should interrupt power. Push the RESET button, power should be restored. If the GFCI fails to operate in this manner, there is a ground current flowing, indicating the possibility of an electrical shock. Do not use this unit. Disconnect the unit and have the problem corrected before using.
7. Traction enhanced-textured tub button must remain clean to minimize slippage.
8. Risk of electrical shock, all pumps and heaters must be connected to a ground fault circuit interrupter (GFCI) protected outlets.
9. Avoid use of alcohol, drugs, or medication while using your tub.
10. Consult your physician before using the whirlpool/air system if you are pregnant and/or have heart conditions.
11. All units must be water tested before installation.
Ariel Walkin Bathtub [ Installation Guide ]
Page 2
Drawings for the tubs
Ariel-265138 660mm W x 1300mm L x 960mm H
Ariel-305439 (760mm W x 1370mm L x 990mm H)
Ariel Walkin Bathtub [ Installation Guide ]
Page 3
GETTING STARTED (1)
UNPACKING THE UNIT
1. Inspect the carton, if carton damage is noted: take a picture if possible, notify the deliverer, write “DAMAGED” on the Proof of
Delivery (P.O.D), and call: (800) 304-3598
2. NEVER LIFT THE TUB BY THE PLUMBING. Doing so can result in leaks, for which the installer is responsible.
3. Immediately inspect the unit for damage even if there is no carton damage. Once the unit is accepted surface damages will be
assumed to be installation related if not reported within 72 hours of delivery. Installers are responsible for damage that occurs once the unit is placed in its niche.
4. Inspect the plumbing for any loose fittings.
5. Remove all packaging material except for the protective plastic. This has been placed on the tub at the factory to eliminate
abrasions from handling. This should only be removed at final clean up.
GETTING STARTED (2)
TESTING YOUR SAFETY TUB BEFORE INSTALLATION
1. All Tubs 100% water tested at the factory and certified to be free of leaks. Transportation and mishandling may cause leaks. It is
necessary to test the bath while there is access to all sides of the bath.
2. This unit should be both static and operationally tested with water. It is best to test the unit outside by filling with a garden hose. A. Place the tub on a completely flat surface in an area where it may be drained after testing. B. Seal the drain (can be sealed with tape for test) and fill the tub three inches above the jets or to a normal level if its a
soaking tub.
C. Allow the water to stand in tub for 10 minutes and then inspect all plumbing and seals for leaks. D. Insure all jets are open and working (every hydro jet is adjustable for both flow rate and direction of flow, depending on the
jet, the water flow is adjusted by either turning the outside ring or the nozzle clockwise and counter clockwise).
GETTING STARTED (3)
NOTE: If the pumps do not operate: A. Check the breaker to insure power is on and the cable connecting the controls to the pump is attached. B. If an optional heater is present, check the indicator light on the heater to insure that power is present. Do not run any pumps or heaters unless the tub is filled with water to proper usage level, 4-inches (10cm) above the highest jet fixture. Damage due to dry-running pumps (running pumps without proper water level height) is not covered under any stated warranty. Failure to perform these tests before installation will make the installer liable for future repair costs.