The parameters of the massage bathtub:
1.The steam generator: the rated
working voltage is
Ac220V.
Ac110V.
2.Frequency is
50Hz.
60Hz.
Water pump : power750W
1.The applicable range of the
voltage:
Ac187V-256V
Ac100V-115V
Transformer: transformation 9V power20W
The pool bottom lamp:voltage AC12V power20W
The pump flux:20 stere/hour
![](/html/6d/6d40/6d40569e97c39ef7ad19d75537073ad3b0c302c8722816f2fe0c778c26cf2197/bg3.png)
Message bathtub water flow control principle illustration
Illustration of the electric principle of massage bathtub
water pump crust
cold water
hot water
water fau
shower
head
hydro-massage water
regulating switch
massage
water pump
power plug
overflow outlet
drawinage
outlet nozzle4
hydro-massage water
M: massage water pump
k: pneumatic switch
Bk: transformer
D: bottom lamp
G1: the earth wire of water pump plug
G2: the earth wire of water pump crust