Argox Information Co AS 8000CL B User Manual

Installation
The AS-8000CL Wireless Imager is easy to install and use. Please see the following figure showing the steps to perform the installation. * Note: Turn off the host computer before installation.
1. Connect the interface (I/F) cable to the cradle.
2. Connect the power cord to the cradle.
3. Route the I/F cable and power cord through the notch.
4. Connect the I/F cable to the host computer communication port.
5. Connect the AC adapter to the wall outlet.
6. Place the imager in the cradle and verify the charge LED is flashing. Charge the battery for at least 8 hours before the first use.
7. To verify operation, please link the imager with cradle first (Refer to “Wireless Connection” in page 6). Point the imager at the barcode and pull the trigger. The imager should emit a beep indicating that the barcode has been scanned and transmitted to the cradle successfully.
1
How To Scan
1. The imager must be pointed at slight angle to the barcode so that the light reflected off the barcode can be seen by the imager. Do not hold the imager perpendicular to the barcode.
2. The scan line must cross the entire barcode. The imager can not read the barcode data without seeing the entire barcode.
2
Troubleshooting
If the imager can not operate properly, the following checks should be performed:
1. The cradle uses an external power supply and the external power supply has failed, the imager will not operate. Change the power supply with a known good power supply and reset the imager.
2. Verify the interface cable is securely connected to the host computer. Consult your technical support personnel or refer to your host system manual to verify the proper connection for the imager.
3
3. Verify the interface cable is securely connected to the cradle.
4. Check that the barcodes are of sufficient quality to be recognized by the imager. Wrinkled, smudged, or torn labels will cause the imager to not read at all. Scan a known good label to check the imager’s read operation.
4
5. Ensure that the cradle’s interface type is compatible with the host computer by consulting your host system manual.
5
Wireless Connection
Linking the imager with the cradle
Follow these instructions to link the two devices:
1. Connect power to the cradle. The radio LED (marked with a light symbol) will blink amber and the cradle will beep.
2. To ensure the cradle is unlinked from any other imager, check if the cradle send inquiry beep or not (see Inquiry Beep Control in page 18).
3. Read the link label on the bottom of the cradle with the imager. The imager will sound a good read beep and the LED will flash amber.
4. Re-place the imager in the cradle to continue the charge.
Once an imager is linked to a cradle, they will remain linked until specific action is taken to unlink them (see Unlinking). They will remain linked if the cradle is unplugged, if the battery is removed from the imager or if the entire charge is used up, and if the imager is taken out of range of the cradle. Under normal operation, scanning of the link label will only be required once in the life of the product.
6
*
Unlinking
There are three ways to unlink an imager from a cradle:
Force imager to disconnect and sleep
1. Scan the “Force imager to disconnect and sleep” barcode – Reading the unlink barcode above while the imager is in range of the cradle will break the link between the two devices and allow another imager to link to the cradle. It will also have the imager in Deep Sleep Mode. If the barcode is read when the imager is out of range of its linked cradle, the imager will unlink, but the cradle will remain linked to the imager and will not allow another imager to be linked to it. In this case, you may perform the item 2 below to link another imager.
2. Scan the Link Label and put on the original cradle – If the cradle is linked with an imager and the original pair was stopped by out of range of the cradle or out of battery of the imager, scan the link label of the cradle with a new imager and then put on the cradle, the cradle will drop the original pair and establish a new link with the new imager.
3. Scan the Link Label on an alternate cradle – Scanning the link label on a cradle will drop the link between the original pair and establish a link between the imager and new cradle. If the new link is performed within range of the old cradle, it is free to establish a link to the next imager that reads its link label. If it is done outside of the range of the old cradle, it retains its old link and will not allow a new imager to link to it until a new imager scan the link label and put on the cradle.
*$%-$$ZZ%%
7
Battery Charging
The imager contains a 1000mAh Lithium-Ion rechargeable battery. A full charged battery will provide up to 15,000 scans over a 12 hours period. Actual charge life on the imager will depend on the configuration of how the imager is configured via the programmable feature in this manual; in particular, Deep Sleep Mode settings can impact battery life.
When the imager is placed in the cradle, the battery will automatically charge. While charging is taking place, the charging LED (marked with a battery symbol) will blink green. When the battery is fully charged, the charging LED will stay on a solid green.
If there is an error in charging either with a failure in the charging circuit or with a failure of the battery, the charging LED will flash red. When this happens, the battery needs to be replaced.
8
How to Change the Battery
In case the contained battery inside the imager needs to be replaced, please follow the procedures below:
1. Loosen the screw at the bottom of the imager.
2. Take off the battery container out of the imager.
3. Disconnect the battery cable connector from the handle board.
4. Remove the used battery from the battery container.
5. Use a new battery pack and replace the used one.
9
Note: DO NOT touch the PCBA inside the imager when replacing the battery. Improper operation may damage the imager.
6. Place the new battery into the battery container.
7. Connect the battery cable connector to the handle board.
8. Put the battery container back to the imager handle.
9. Fasten the screw to the imager.
10
Wireless Features
The AS-8000CL Wireless model includes an imager and a cradle. When the imager and cradle are linked together, the imager will read and decode barcodes and transmit them via a Wireless radio to the cradle. The cradle will then transmit the barcode data to the host computer over the host cable. The host interfaces available from the cradle are RS-232, Keyboard wedge, and USB as a normal corded imager.
11
*
*
Auto Update
When this feature is enabled, an imager and its linked cradle can automatically ensure they stay in sync with regard to firmware and/or configuration. This is accomplished by the linked imager and cradle comparing firmware version number and configuration file check sum. If either is different, the cradle will automatically update the imager with its firmware/configuration.
If the units are linked, any changes made to the cradle’s configuration through the scan utility software will automatically be sent to the imager at the completion of the programming session. By the same token, any changes made to the linked imager’s configuration will be transmitted to the cradle at the end of the programming session.
The following options are available for Auto Update:
z Enable configuration and firmware auto update
Allows both configuration and firmware updating (Default).
z Enable configuration auto update only – Allows
only configuration updating.
*$%-1BA00%%
*$%-1BA01%%
12
*
*
z Enable firmware auto update only – Allows only
firmware updating.
*$%-1BA02%%
z Disable auto update – No automatic updates will be
performed.
*$%-1BA03%%
13
*
*
*
*
*
Deep Sleep Mode
The WIRELESS imager can be placed into Deep Sleep Mode after this programmed duration (since the units’ last
scanning activity). Press its trigger to wake the imager form this mode.
z Disable Deep Sleep Mode (Default)
z Duration 10 minutes - Force imager into deep sleep
mode if there is no barcode read in 10 minutes.
z Duration 30 minutes - Force imager into deep sleep
mode if there is no barcode read in 30 minutes.
z Duration 60 minutes - Force imager into deep sleep
mode if there is no barcode read in 60 minutes.
z Duration 90 minutes - Force imager into deep sleep
mode if there is no barcode read in 90 minutes.
*$%-7AJ00%%
*$%-7AJ01%%
*$%-7AJ03%%
*$%-7AJ06%%
*$%-7AJ09%%
14
*
*
*
*
Handcuff Mode (Leash Alarm)
When enabled, the Leash Alarm will force the imager to sound an alarm for a preprogrammed length of time to notify if an imager is leaving the immediate vicinity of the cradle. This is especially useful in instances where the imager might inadvertently have been placed in a bag or cart.
z Disable Handcuff Mode (Default)
z Alarm for 10 seconds when out of range
z Alarm for 30 seconds when out of range
z Alarm for 60 seconds when out of range
*$%-7AM00%%
*$%-7AM10%%
*$%-7AM30%%
*$%-7AM60%%
15
*
*
*
Wireless Connectivity
The AS-8000CL can be linked to any Bluetooth (BT) enabled device which can accept such a connection with other devices. To implement this feature, user should set the imager to “Cradle/Dongle connection auto detection” first. And then set the PIN code to 0000 assigned to the target Bluetooth device. In this case, the PIN code of the Bluetooth enabled device should be set to 0000 to be identical with your imager.
z Cradle connection only – The imager can be used
only with cradle (Default).
z Cradle/Dongle connection auto detection – The
imager can be linked to either a cradle or other Bluetooth enabled devices.
z Set PIN code to 0000
Note: The imager only support “Serial Port Profile” under
“Dongle connection”
*$%-1AB00%%
*$%-1AB01%%
*$%-$0000%%
16
*
$$*
Wireless Connectivity (continued)
User is also allowed to set any four- to six-character PIN code assigned to the target Bluetooth device using the setting procedures below:
STATE CODE
Cradle/Dongle
connection auto
detection
Program
Begin PIN setting
PIN no.
(Set 4~6 character)
End PIN setting
*/0*
*/2*
*/4*
*/6*
*/8*
*$%-1AB01%%
*$%+PRO*
*#PIN*
*%
*/1*
*/3*
*/5*
*/7*
*/9*
17
*
*
*
*
*
*
Inquiry Beep Control
When the cradle is not linked to an imager, the Radio LED will blink amber and the cradle will beep. This beep can be disabled or reconfigured to sound for different durations by using the following programming barcodes.
z Disable inquiry beep
z Inquiry beep continuously (Default)
z Inquiry beep every 10 seconds
z Inquiry beep every 20 seconds
z Inquiry beep every 30 seconds
z Inquiry beep every 40 seconds
*$%-5AJ00%%
*$%-5AJ08%%
*$%-5AJ01%%
*$%-5AJ02%%
*$%-5AJ03%%
*$%-5AJ04%%
18
*
*
*
z Inquiry beep every 50 seconds
*$%-5AJ05%%
z Inquiry beep every 60 seconds
*$%-5AJ06%%
z Inquiry beep every 70 seconds
*$%-5AJ07%%
19
*
*
*
*
*
*
Cradle Beep Loudness Control
The beep loudness of cradle can be defined with the following levels.
z Cradle beep off
z Level 1
z Level 2
z Level 3 (Default)
z Level 4
z Level 5
*$%-5AK00%%
*$%-5AK01%%
*$%-5AK02%%
*$%-5AK03%%
*$%-5AK04%%
*$%-5AK05%%
20
*
*
z Level 6
z Level 7
*$%-5AK06%%
*$%-5AK07%%
21
*
*
*
*
Additional Features
Here list three additional features of AS-8000CL wireless imager for the convenience of use to users.
z Download firmware from the cradle
z Download configuration parameters from the
cradle
z Force cradle to reset the configuration – This
feature will also force imager to reset the configuration to factory default.
Note: To meet the regulation of air transportation, the wireless imager should disconnect with the cradle during shipment. All AS-8000CL wireless imagers are suggested to scan the following command before packaging into boxes and ship to customers.
Force imager to disconnect and sleep
*$%-+CP%%
*$%-+CC%%
*$%-+IC%%
*$%-$$ZZ%%
22
V
Default setting
For each barcode shown as below:
Code Type
UPC-A V V V A UPC-E V V V E EAN-13 V V V F EAN-8 V V V FF Code-39 V Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 B Codabar % Code-128 V V # Code-93 V two digits & Code-11 V One digit O MSI/Plessey V @ UK/Plessey V @ Telepen S Standard 2 of 5 V V i China Post t Italian Pharmacode. Code-16K - - PDF417 V - - EAN UCC Composite RSS-14 R4 RSS-Limited RL RSS-Expanded RX
Micro-PDF - - U
Read
Enable
Checksum
erification
Enable
V i
- - i
p
- - RC
Checksum
Transmission
Enable
Code
ID
23
Specification
ArgoScan 8000CL
Specification Model 8000CL
Operational
Light Source 630 nm Visible Red LED Optical System 2048 pixel CCD
(Charge-coupled device)
Depth of Scan Field Up to 260mm (CODE 39, PSC=90%,
20mils) Scanning Width 50mm wide @ 0mm Scan Speed 30~450 scans/sec Resolution
Print Contrast 25% or more Scanning Angle Front: 60° Rear: 60° Yaw: 70° Decode Capability Auto-discriminates all standard
Beeper Operation 7 tones or no beep Indicator on imager Green & Red led Mechanical Length 186 mm Width-handle 33 mm Width-head 75 mm Depth-handle 32 mm Depth-head 44.5 mm
0.1mm (4mils)
barcodes and some 2D symbologies
including PDF-417 and RSS code; Other symbologies can be ordered
Code39,PCS=90%
optionally
24
Weight Less than 165g (with a battery) Case material ABS (over molded at contact points) Cushion material Double injection Cradle interface RS232, Keyboard wedge, USB Electrical Input Voltage
(Cradle) Power - Operating (Cradle) Power – Standby (Cradle) Current – Operating (Cradle) Current – Standby (Cradle) Charge Current (Cradle) Input Voltage (Imager) Power - Operating (Imager) Power – Standby (Imager) Current – Operating (Imager) Current – Standby (Imager) Current – Sleep (Imager) Light Level Up to 40000 Lux
5 VDC ± 10% VDC
5 VDC
5 VDC
120 mA
120 mA
660 mA
3.4V ~ 4.2V
3.2V ~ 4.0V
3.4V ~ 4.2V
225 mA
32 mA
2 mA
25
Shock (Imager) 1.5m drop onto concrete Shock (Cradle) 0.9m drop onto concrete Contaminants Seals to resist airborne particulate
contaminants (IP42) Ventilation None required Programming
Programming method Program upgrade Enabled by built-in flash memory Programmable characteristics
Manual (Reading special barcode), Windows configuration program
Code type selection, check digit selection Decoding option Decoding option Transmitted character delay, Header selection, trailer selection, message suffix, good read beep tone and volume, scanner trigger selection Keyboard emulation type (intermessage delay, keyboard type and keyboard language) Serial interface type (ACK/NAK, Xon/Xoff, RTS/CTS, good read LED control, start/stop bits)
26
Indications of AS-8000CL
Imager:
Status
Link
established
Loss link
(handcuff
mode
enable
Loss link
(handcuff
mode
disable)
Hardware
fail
Program
download
LED
Program
checksum
fail
Data
transmitting
Data trans.
Fail
Data trans.
OK
Low battery
(<3.2V)
(Trigger is
pressed)
Green
ON for
200msec
Red LED
LED Blink once
Blink
Flash
Flash
Flash
ON
Flash
ON for
300msec
Good beep
Orange
LED
A special
Sound like
grasshopper
Blink twice
A special
High freq.
300msec
Error beep
Beeper
beep
beep
Beep for
27
Cradle:
Status
Inquiry Blink
Connecting Blink
Link
established
Hardware fail Flash
Data receiving
RF
status
LED
Battery
LED
from the scanner
Barcode data
proof or
transmitted
Data send to
the host Fail
Program
download
Program
checksum Fail
Idle
Charging Blink
Battery full ON
Battery/charger
Fail
Green
LED
ON
Flash
Red
Orange
LED
Flash
Blink
ON for
0.5sec
LED
Beeper
Beeps
once a
second
Good
beep Error
beep
28
Programming the AS-8000CL
To program the 8000CL, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented.
To program each option, you must:
1. Scan the Program barcode on the parameter setting part.
2. Enter the option mode by scanning the Option Bar Code (also on the Parameter setting part).
3. To the right of the option barcode, the necessary alphanumeric inputs are listed. Scan these alphanumeric entries from the back fold out page. To confirm above steps, you must scan the Finish barcode on the back fold out page.
4. Once you have finished programming. Scan the Exit barcode, listed on the lower right hand corner of each parameter setting part.
29
Option Bar Code Option Alphanumeric Entry
Program
Program Barcode
Interface
selection
Option Barcode
Keyboard Wedge
RS-232
Wand emulation
USB
Keyboard/RS-232
Auto detection
Reserved
Exit Barcode
00
01
02
03
04
05
Exit
Back Fold Out
Finish barcode
30
Interface Selection
This cradle comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, and USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface. By plugging different cables, setting right interface, then the cradle will be changed to another interface. However, you must make sure which cable you need. Keyboard/RS232/UBS Auto detection: By setting this function, it will automatically select the Keyboard wedge or RS-232 or UBS interface for user.
Option Bar Code Option Alphanumeric
Program
Entry
Interface selection
Note:-Default
Keyboard Wedge RS-232 USB Keyboard /RS232/USB Auto detection
31
00 01 03
04
Exit
Keyboard wedge
As a keyboard interface, the cradle supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware.
Keyboard Type: Select keyboard type connector of your host computer. Cradle must be selected to the appropriate host interface cable converter.
Option Bar Code Option Alphanumeric
Program
Entry
Keyboard type
IBM AT, PS/2 Reserved Reserved Reserved Reserved Reserved Reserved
32
00
01 02 03 04 05 06
Exit
Keyboard wedge
Keyboard Layout: The selecting of keyboard layout
supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard” to select country at “language” item. For details, please refer to your DOS or WINDOWS user’s manual. Keyboard Speed: By selecting, you can change output speed of data transmission to match with host computer. Generally, set 00 or 01 in working high speed. If some output characters of barcode have been lost, you may need to set 05 or 06 to match your host keyboard speed. Function Key: Set Enable, imager can output code as pressing function-key in your application program while the barcode datas contain ASCII value between 01 Refer to ASCII table. Numeric Key: The Keypad has to be selected if your application program is only keypad numeric code acceptable. So, cradle will output code as press numeric keypad when it read numeric digit. (The keypad is in the right side of keyboard, and Num Lock control key is also on.) If Alt+Keypad is selected, the data characters will be transmitted as “Alt” + numbers. For example, when sending character “A”, the actual sending will be “Alt”+65. It is also useful when using non-English OS and keyboard layout.
Option Bar Code Option Alphanumeric
Program
16 to 1F16.
Entry
33
Keyboard layout
USA Belgium Danish France Germany
00 01 02 03 04
Keyboard speed
Function key
Alpha/Numeric key
Italian Portuguese Spanish Swedish Switzerland UK Latin American Japanese 0-8 0 : high clock rate 8 : low clock rate Disable Enable
Alphabetic key Numeric keypad (Num lock state only)
05 06 07 08 09 10 11 12 00-08 03
00 01
00 01
*
Alt+Keypad
34
02
Exit
Keyboard wedge
Caps Lock: By selecting Caps lock”ON” or Caps lock”OFF”, imager can get Caps Lock status.
Power-on simulation: All of the PCs check the keyboard
status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on.
Inter-character delay: This delay is inserted after each data characters transmitted. If the transmission speed is too high, the system may not be able to receive all characters. Adjust it and try out suited delay to make system work properly.
Block transmission delay: It is a delay timer between barcode data output. The feature is used to transfer continually with shorter barcode data or multi-field scanning.
35
Option Bar Code Option Alphanumeric
Program
Entry
Caps lock
Power-on simulation
Inter-character delay
Block transmission delay
Caps lock”ON” Caps lock”OFF”
Disable Enable
00-99 (msec) 00-99
00-99 (10 msec) 00-99
00
01
00
01
02
10
Exit
36
RS-232
CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 11 Xoff: Transmit Off (ASCII Code13
Flow control: None-The communication only uses TxD and RxD signals
without regard for any hardware or software handshaking protocol. RTS/CTS-If the cradle wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication. If there is no replied CTS signal from the host computer after the timeout (Response Delay) duration, the imager will issue a 5 warning beeps. Xon/Xoff- When the host computer is unable to accept data, it sends a Xoff code to inform the cradle to suspend data transmission, and Xon to continue. ACK/NAK- When the ACK/NAK protocol is used, the cradle waits for an ACK (acknowledge) or (not acknowledge) from the host computer after data transmission, and will resend in response to a NAK.
Inter-character delay: It is delay time between data character’s data output. It is also same as Inter-char. delay of keyboard wedge.
Block transmission delay: It is a delay time between barcode data output. It is also same as Block transmission delay of keyboard wedge.
Response delay: This delay is used for serial communication of the cradle to waiting for handshaking acknowledgment from the host computer.
16)
16)
37
Option Bar Code Option Alphanumeric
Program
Entry
Flow control
Inter-character delay
Block transmission delay
Response delay
None RTS/CTS Xon/Xoff ACK/NAK RTS/CTS bracket mode 00-99 (msec)
00-99 (10 msec)
00-99 (100 msec)
38
00 01 02 03 04
00-99 00
00-99 00
00-99 20
Exit
Option Bar Code Option Alphanumeric
Program
Entry
Baud rate
Parity
Data bit
Stop bit
300 BPS 600 BPS 1200 BPS 2400 BPS 4800 BPS 9600 BPS 19200 BPS 38400 BPS None Odd Even 8 bits 7 bits
One bit Two bits
00 01 02 03 04 05
06 07 00
01 02 00
01
00
01
Exit
39
Pin Assignments
10-pin
AS Series 10-pin RJ-45 Connector
Pin RS-232 Keyboard
1 I/F I/F 2 NA NC 3 TXD NC 4 NC CLK / PC 5 GND DATA / PC 6 CTS DATA / KB 7 RXD NC 8 RTS CLK / KB 9 GND GND
10 NC GND
1
2
3
4
5
6
7
8
9
10
40
Keyboard Wedge PS/2 Connector (To Host Side):
Pin Mini-DIN 6P Male Mini-DIN 6P Female
1 DATA / PC DATA / KB 2 NC NC 3 GND GND 4 VCC (+5V) NA 5 CLK / PC CLK / KB 6 NC NC
4
2
1
3
Mini-DIN 6P Male Connector
RS-232 DB-9F Connector (To Host Side):
Pin Definition
1 NC 2 TXD 3 RXD 4 NC 5 GND 6 NC 7 CTS 8 RTS 9 NC
Mini-DIN 6P Female Connector
6
5
4
62
5
1
3
5
9
4
8
3
7
2
6
1
41
Scan
Scanning mode: Good-read off-The trigger button must be pressed to
activate scanning. The light source of imager stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed. Momentary-The trigger button acts as a switch. Press button to activate scanning and release button to stop scanning. Alternate-The trigger button acts as a toggle switch. Press button to activate or stop scanning. Timeou t off-The trigger button must be pressed to activate scanning, and imager stops scanning when no code is decoded after the Stand-by duration elapsed. Continue-Imager always keeps reading, and it does not matter when trigger button is pressed or duration is elapsed. Test only-For test of scan performance only. It is improper to be utilized to check the accuracy of transmitted data.
Double read timeout: The imager will require a several times successful decoding to confirm the data when enabled. The more confirming times required, the more inhibitive miss-reading code will be shown. The Multi field scan Enable function won’t be able to work if set Double confirm.
Double confirm: If the barcode has been scanned twice, then only the first barcode will be accepted.
Supplement Check Counter: It will be more reliable to read the barcode with extension (supplement) like UPCE/A or EAN-8/13, but slow down the decoding speed when this counter is set more.
42
Option Bar Code Option Alphanumeric
Program
Entry
Scanning mode
Stand-by duration
Double read timeout
Double confirm
Good-read off Momentary Alternate Timeout off Continue Test only 01-99 (second) 00-99
01-99 (10 msec) 01-99
00-09
(00: no double
confirm)
00 01
02 03 04 05
06
50
00-09 00
43
Exit
Scan
Global min./max. code length: These are to define the min/
max readable code length of all symbologies. Code length less than min. code length or more than max. code length will not be read. In popular, you can set the same value for both min. and max. reading length to force the fixed length barcode decoded. The values of setting have no effect on certain symbologies with fixed length. You can specify the settings for individual barcode by the min/max code length setting of each barcode. Notes 1): Please set the min/max length if you have special
demand for individual barcode.
2): Include the Check sum digits if you want to set Global min/max code length.
Inverted image scan: Set Enabled the imager will scan both black/white barcode with white/black background.
44
Option Bar Code Option Alphanumeric
Program
00-99 00-99
Entry
Global min. code length
Global max. code length
Inverted image scan
04
00-99 00-99
99
Disable Enable
00 01
Exit
45
Indication
Power on alert: After power-on the cradle it will generate an
alert signal to indicate a successful self-test.
LED indication: After each successful reading, the LED above the imager will light up to indicate a good barcode reading.
Beeper indication: After each successful reading, the imager will beep buzzer to indicate a good barcode reading, and its Beep loudness, Beep tone freq. and Beep tone duration are adjustable.
Beep loudness/Beep tone freq./Beep tone duration: You can adjust Beep Loudness, Beep tone and Beep duration for a good reading upon favorite usage.
46
Option Bar Code Option Alphanumeric
Program
Entry
Disable Enable
Power on alert
Disable Enable
LED indication
Disable Enable
Beeper indication
00-07 (00 - off)
Beep loudness
00-99 (100Hz) 00-99
Beep tone freq.
00-99 (10 msec) 00-99
Beep tone duration
00 01
00 01
00 01
00-07
07
26
08
Exit
47
UPCA
Format
Leading
Zero
Read: Enable or disable the read function. Check-sum transmission: By setting Enable, checks sum
will be transmitted. Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero. It will beep instead of reading anything when the truncate value is more than the barcode data digits or the value of Truncate Leading is overlapped with that of the Ending. The maximum value of truncate digits is 15. Code ID setting: Code ID setting is a character used to represent the symbol upon a succeeding reading. A Code ID setting is prefixed to the data begin or end transmitted if the feature is selected. If you want application to transmit Code ID, you must set Code ID transmission to Enable first. Refer to Code ID transmission.
Data Digits
(11 Digits)
Check
Digit
48
Option Bar Code Option Alphanumeric
Program
Entry
Read
Check-sum transmission
Truncate leading
Truncate ending
Code ID setting
Disable Enable
Disable Enable
0-15 00-15
0-15 00-15
00-ffH ASCII code
00 01
00 01
00
00
00-ffH
< A >
Exit
49
UPCA
Insertion group number selection: The imager offers max.
two insertion groups for one symbology. By setting one or two digits to indicate which insertion group you want to insert. You may refer to Character insertion. The function is to insert specific characters as a group into transmitted data of selected symbologies. Enable the group insertion by selecting the group number. Example: Group 2 → set 02 or 20.
Group 1 and 4 → set 14 or 41.
Notes 1): Group number set to “0” means that no group
insertion required.
2): Details about the Insert Group settings please refer to page 117~120, and page 126 ASCII code table.
Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 characters for WPC code. Format
Leading
Truncation / Expansion: The leading “0” digits of UPCA data characters can be truncated when the function is enabled.
Zero
Data Digits
(11 Digits)
Supplement Digits
Check
Digit
2 or 5 or
UCC / EAN 128
50
Option Bar Code Option Alphanumeric
Program
Entry
00-44 00-44
Insert group number selection
Supplement digits
Truncation/ Expansion
The
None 2 digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All None Truncate leading zero Expand to EAN13
51
00
00 01 02 03 04 05 06 07 00
01
02
Exit
UPCE
Read: Format
Leading
Zero
Check-sum transmission: By setting Enable, checks sum will be transmitted.
Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Option Bar Code Option Alphanumeric
Data Digits (6
Program
Digits)
Check
Digits
Entry
Read
Check-sum transmission
Truncate leading
Disable Enable
Disable Enable
0-15 00-15
52
00
01
00 01
00
0-15 00-15
Truncate ending
Code ID setting
00-ffH ASCII code
00
00-ffH < E >
Exit
53
UPCE
Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA. Supplement digits: Format
Leading
Zero
Expansion: The expansion function is used only for UPCE and EAN-8 code reading. It extends to 13-digits with “0” digits when the feature is enabled. Example: Barcode “0123654” Output: “0012360000057” UPCE-1: Enable imager to read UPCE with leading digit 1.
Option Bar Code Option Alphanumeri
Data Digits
(6 Digits)
Program
00-44 00-44
Check
Digit
Supplement Digits
2 or 5 or
UCC/EAN 128
c Entry
Insert group number selection
54
00
Supplement digits
None 2 digits 5 digits 2,5 digits
00
01 02 03
Truncation/Expansion
Expansion
*OAM*
UPCE-1
UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All None Truncate leading zero Expand to EAN13 Expand to UPCA Disable Enable
Disable Enable
04 05 06 07
00
01
02 03
00
01
00
01
Exit
55
EAN-13
Read: Format
Data Digits (12 Digits) Check Digits
Check-sum transmission: By setting Enable, checks sum will be transmitted.
Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Truncate leading zero: Refer to Truncation / Expansion of UPCA.
The
Option Bar Code Option Alphanumeric
Program
Entry
Read
Check-sum transmission
Truncate leading
Disable Enable
Disable Enable
0-15 00-15
56
00
01
00 01
00
0-15 00-15
Truncate ending
00
Exit
57
EAN-13
Code ID setting: Refer to page 51 Insertion group number
selection of UPCA. Insertion group number selection: Refer to Insertion group selection of UPCA. Supplement digits: Format
Data Digits
(12 Digits)
ISBN/ISSN: The ISBN (International Standard Book Number) and ISSN (International Standard Serial Number) are two kinds of barcode for book and magazines. The ISBN is 10 digits with leading “978” and the ISSN is 8 digits with leading “977” of the “EAN-13” symbology.
Example: Barcode “9789572222720” - Output: “9572222724” Example: Barcode “9771019248004” - Output: “10192484”
Check
Digits
Supplement Digits
2 or 5 or
UCC / EAN 128
Program
Option Bar Code Option Alphanumeric
Entry
Code ID setting
Insert group number selection
00-ffH ASCII code
00-44 00-44
58
00-ffH < F >
00
Supplement digits
None 2 digits 5 digits 2,5 digits UCC/EAN 128
00
01 02 03 04
ISBN/ISSN conversion
*GAM*
ISBN ID setting
2, UCC/EAN 128 5, UCC/EAN 128 All Disable Enable
00-ffH ASCII code
05 06 07
00
01
00-ffH < I >
Exit
59
EAN-8
Read: Format
Data Digits
(7 Digits)
Check-sum transmission: By setting Enable, checks sum will be transmitted. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Program
Check
Digits
Entry
Read
Check-sum transmission
Truncate leading
Disable Enable
Disable Enable
0-15 00-15
60
00
01
00 01
00
0-15 00-15
Truncate ending
00-ffH ASCII code
Code ID setting
00-44 00-44
Insert group number selection
00
00-ffH, 00-ffH < FF >
00
Exit
61
EAN-8
Supplement digits: Format
Data Digits
(7 Digits)
Truncation / Expansion: Refer to Truncate Leading zero of UPCE. Expansion: Refer to Expansion of UPCE.
Check
Digits
Supplement Digits
2 or 5 or
UCC/EAN 128
Option Bar Code Option Alphanumeric
Program
Entry
Supplement digits
Truncation / Expansion
None 2 digits 5 digits 2,5 digits UCC/EAN 128 2, UCC/EAN 128 5, UCC/EAN 128 All None Truncate leading zero Expand to EAN13
62
00
01 02 03 04 05 06 07
00
01
02
Expansion
Disable Enable
00
01
Exit
63
Code 39
Read: Format
Start
Data Digits
( Variable) Check-sum verification: The checksum of Code-39 is optional and made as the sum module 43 of the numerical value of the data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Each symbology has own Max./Min. Code Length. They can be set to qualify data entry. If their Max./Min. Code Length is zero, the Global Min./Max. Code Length is in effect. The length is defined as to the actual barcode data length to be sent. Label with length exceeds these limits will be rejected. Make sure that the Minimum length setting is no greater than the Maximum length setting, or otherwise all the labels of the symbology will not be readable. In particular, you can see the same value for both Minimum and Maximum reading length to force the fixed length barcode decoded. Truncate leading/ending: Refer to Truncate leading/ending of UPCA. Code Id setting: Refer to Code ID setting of UPCA.
Option Bar Code Option Alphanumeric
Program
Checksum
(Optional)
Entry
End “
Read
Disable Enable
64
00 01
Check-sum verification
Disable Enable
00
01
Check-sum transmission
Max. code length
Min. code length
Truncate leading
Truncate ending
Code ID setting
Disable Enable
00-64 00-64
00-64 00-64
0-15 00-15
0-15 00-15
00-ffH ASCII code
65
00
01
00
00
00
00
00-ffH
>
<
Exit
Code 39
Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Format: The Full ASCII Code-39 is an enhanced set of Code-39 that is the data with total of 128 characters to represent Full ASCII code. It is combined one of the digits +, %, $ and/ with one of the alpha digits (A to Z).
Append: This function allows several symbols to be concatenates and be treat as one single data entry. The imager will not transmit the embedded appending code (space for Code-39). If Enable and other symbols were read again with the appended code, then codes will be transmitted without Code ID, Preamble and Prefix. When a symbol was decoded without the appended code, the data will be transmitted without Code ID and Prefix, but the Postamble Suffix codes are appended. This function is used when the first number of code 39 is a space. Example: □123456.
Start/end transmission: The start and end characters of Code-39 are“”. Y ou can transmit all data digit s including two “”.
Option Bar Code Option Alphanumeric
Program
Entry
Insert group number selection
00-44 00-44
00
66
Format
Standard Full ASCII
00 01
Disable Enable
Append
Disable
Enable Start/end transmission
00 01
00 01
Exit
67
Interleaved 2 of 5
Read: Format
Data Digits
(Variable)
Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Program
Checksum
(Optional)
Entry
Read
Check-sum verification
Disable
Enable
Disable
Enable
68
00 01
00 01
Check-sum transmission
Disable
Enable
00-64 00-64
00
01
Max. code leading
00-64 00-64
Min. code leading
0-15 00-15
Truncate leading
0-15 00-15
Truncate ending
00-ffH ASCII
code Code ID setting
00-44 00-44
Insert group number selection
69
00
00
00
00
00-ffH < i >
00
Exit
Industrial 2 of 5
Read: Format
Data Digits
(Variable)
Max./Min. code length: Refer to Max./Min. code length of Code-39.
Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Program
Checksum
(Optional)
Entry
Read
Max. code length
Min. code length
Disable
Enable
00-64 00-64
00-64 00-64
70
00 01
00
00
0-15 00-15
Truncate leading
Truncate ending
Code ID setting
Insert group number selection
0-15 00-15
00-ffH ASCII
code
00-44 00-44
71
00
00
00-ffH
< i >
00
Exit
Matrix 2 of 5 Eur
Read: Format
Data Digits
(Variable) Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Program
Checksum
(Optional)
Entry
Read
Checksum
Verification
Disable Enable
Disable Enable
72
00 01
00 01
Checksum
Transmission
Disable Enable
00-64 00-64
00
01
Max. code length
Min. code length
Truncate leading
Truncate ending
Code ID setting
Insert group number selection
00-64 00-64
0-15 00-15
0-15 00-15
00-ffH ASCII code
00-44 00- 44
73
00
00
00
00
00-ffH < B >
00
Exit
Codabar
Read: Format
Start Data Digits (Variable) Checksum (Optional) End
Checksum Verification: The checksum is made as the sum module 16 of the numerical values of all data digits.
Checksum Transmission: By setting Enable, checksum will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of Code-39.
Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Option Bar Code Option Alphanumeric
Program
Entry
Read
Checksum Verification
Disable Enable
Disable Enable
74
00 01
00 01
Checksum Transmission
Max. code length
Min. code length
Truncate leading
Truncate ending
Disable Enable
00-64 00-64
00-64 00-64
0-15 00-15
0-15 00-15
00 01
00
00
00
00
Code ID setting
00-ffH ASCII code
75
00-ffH
< % >
Exit
Codabar
Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA. Start/End type: The Codabar has four pairs of Start/End pattern; you may select one pair to match your application. Start/End Transmission: Refer to Start/End T r ansmission of Code 39.
Option Bar Code Option Alphanumeric
Insert group selection
Program
Entry
00-44 00-44
00
Start/End type
Start/End transmission
ABCD/ABCD abcd/abcd ABCD/TN*E Abcd/tn*e Disable Enable
76
00
01 02 03 00 01
Exit
Code-128
Read: Format
Data Digits
(Variable) Checksum Verification: The checksum is made as the sum module 103 of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Option Bar Code Option Alphanumeric
Program
Checksum
(Optional)
Entry
Read
Checksum Verification
Checksum Transmission
Disable Enable
Disable Enable
Disable Enable
77
00 01
00 01
00 01
Exit
Code-128
Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA. Format: The Code-128 can be translated to UCC/EAN-128 format if it starts with FNC1 character. The first FNC1 will be translated to “]C1”,and next to be a field separator code as <GS>(1D ]C1 Data <GS> Data Checksum Append: When the function is enabled, it won't show the
data immediately if imager read the barcode includes FNC2 code. It will show all data until it read the barcode, which doesn't have FNC2 code.
16).
Program
Option Bar Code Option Alphanumeric
Entry
Max. code length
Min. code length
00-64 00-64
00-64 00-64
0-15 00-15
78
00
00
00
Truncate leading
Truncate ending
0-15 00-15
00
Code ID setting
Insert group number selection
Format
Append
00-ffH ASCII code
00-44 00-44
Standard UCC/EAN-128
Disable Enable
00-ffH < # >
00
00 01
00 01
Exit
79
Code-128
ISBT enable: This feature is commonly used in a blood bank
for identification. ISBT concatenation timeout: This feature is to setup the timeout duration of ISBT concatenation. Field separator code: This feature is only used for UCC/EAN-128 format. This Field separator code means you can reassign second or after a FNC1 for your usage. The default of ASCII code is <GS>(1D UCC/ EAN 128 ID setting: To setting the code ID for UCC/EAN-128 output format.
16).
Option Bar Code Option Alphanumeric
Program
Entry
ISBT enable
Field separator code
*8AK*
UCC/EAN-128 ID setting
Disable Enable normal
00-ffH ASCII code
00-ffH ASCII code
80
00
01
00-ffH
1DH
00-ffH < # >
Exit
Code-93
Read: Format
Data Digits
(Variable) Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum Transmission: By setting Enable, checksum will be transmitted.
Option Bar Code Option Alphanumeric
Program
Checksum1
(Optional)
Checksum2
(Optional)
Entry
Read
Checksum Verification
Checksum Transmission
Disable Enable
Disable Enable (two digits)
Disable Enable
81
00 01
00 01
00 01
Exit
Code-93
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Max. code length
Program
Entry
00-64 00-64
00
00-64 00-64
Min. code length
Truncate leading
Truncate ending
00
00
00
0-15 00-15
0-15 00-15
82
Code ID setting
Insert group number selection
00-ffH ASCII code
00-44 00-44
00-ffH < & >
00
Exit
83
Code-1 1
Read: Format
Data Digits
(Variable) Checksum Verification: The checksum is presented as the sum module 11 of all data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Program
Checksum1
(Optional)
Checksum2
(Optional)
Entry
Disable Enable
Read
Disable
One digit Checksum Verification
Two digits
84
00 01
00 01
02
Checksum
Transmission
Max. code length
Min. code length
Truncate leading
Truncate ending
Disable
Enable
00-64 00-64
00-64 00-64
0-15 00-15
0-15 00-15
00 01
00
00
00
00
Code ID setting
Insert group number selection
00-ffH ASCII
code
00-44 00-44
85
00-ffH
< O >
00
Exit
MSI/plessey
Read: Format
Data Digits
(Variable) Checksum Verification: The MSI/Plessey has one or two optional checksum digits. The checksum is presented 3 kinds of method Mod10, Mod10/10 and Mod 11/10. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum1 and checksum2 will be transmitted upon your selected checksum verification method. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Program
Checksum1
(Optional)
Checksum2
(Optional)
Entry
Read
Checksum Verification
Disable Enable
Disable Mod 10 Mod 10/10 Mod 11/10
86
00
01
00 01
02 03
Checksum Transmission
Max. code length
Min. code length
Truncate leading
Truncate ending
Disable Enable
00-64 00-64
00-64 00-64
0-15 00-15
0-15 00-15
00 01
00
00
00
00
Code ID setting
Insert group number selection
00-ffH ASCII code
00-44 00-44
87
00-ffH
< @ >
00
Exit
UK/plessey
Read: Format
Data Digits
(Variable) Checksum Verification: The UK/Plessey has one or two optional checksum digits. The checksum1 and checksum2 will be calculated as the sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Program
Checksum1+2
(Optional)
Entry
Read
Checksum Verification
Disable Enable
Disable Enable
88
00 01
00 01
Checksum Transmission
Max. code length
Min. code length
Truncate leading
Truncate ending
Disable Enable
00-64 00-64
00-64 00-64
0-15 00-15
0-15 00-15
00 01
00
00
00
00
Code ID setting
Insert group number selection
00-ffH ASCII code
00-44 00-44
89
00-ffH < @ >
00
Exit
Telepen
Read: IAT A (International Air Transport Association). Checksum Verification: The checksum is presented as the
sum module 10 or 11 of the data digits. Checksum Transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Program
Entry
Read
Checksum Verification
Checksum Transmission
Disable Enable
Disable Enable
Disable Enable
90
00 01
00 01
00 01
Max. code length
Min. code length
Truncate leading
Truncate ending
00-64 00-64
00-64 00-64
0-15 00-15
0-15 00-15
00
00
00
00
Code ID setting
Insert group number selection
Format
00-ffH ASCII code
00-44 00-44
Numeric only
Full ASCII only
91
00-ffH < S >
00
00
01
Exit
Standard 2 of 5
Read: Format
Data Digits
(Variable)
Check-sum verification: The checksum is made as the sum module 10 of the numerical values of all data digits. Check-sum transmission: By setting Enable, checksum will be transmitted. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code ID setting: Refer to Code ID setting of UPCA. Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Program
Checksum1
(Optional)
Entry
Read
*JAB*
Check-sum verification
Disable Enable
Disable Enable
92
00 01
00 01
*JAC*
Check-sum transmission
Max. code length
Min. code length
Truncate leading
Truncate ending
Disable Enable
00-64 00-64
00-64 00-64
0-15 00-15
0-15 00-15
00 01
00
00
00
00
Code ID setting
Insert group number selection
00-ffH ASCII code
00-44 00-44
93
00-ffH
< i >
00
Exit
China Post
Read: Format
Data Digits
(Variable)
Max./Min. code length: Refer to Max./Min. code length of Code-39.
Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Checksum1
(Optional)
Option Bar Code Option Alphanumeric
Program
Entry
Read
Max. code length
Min. code length
Disable Enable
00-64
00-64
94
00
01
00-64 11
00-64 11
Truncate leading
0-15
00-15 00
Truncate ending
Code ID setting
Insert group number selection
0-15
00-ffH ASCII code
00-44
00-15 00
00-ffH < t >
01-44 00
Exit
95
Italian Pharmacode (Code 32)
Read: Format
Data Digits
(Variable)
Max./Min. code length: Refer to Max./Min. code length of Code-39.
Truncate leading/ending: Refer to Truncate leading/ending of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Leading “A”: If this function is enabled, each prefix of data shall be A.
Checksum1
(Optional)
Program
Option Bar Code Option Alphanumeric
Entry
Read
Max. code length
Disable Enable
00-64
96
00
01
00-64 12
Min. code length
00-64
00-64 09
Truncate leading
Truncate ending
Code ID setting
Insert group number selection
Leading “A”
0-15
0-15
00-ffH ASCII code
00-44
Disable Enable
97
00-15 00
00-15
00
01-ffH < p >
00-44 00
00
01
Exit
Code-16K
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 51
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Program
Entry
Read
Truncate leading
Truncate ending
Code ID setting
Disable Enable
0-15 00-15
0-15 00-15
00-ffH ASCII code
98
00
01
00
00
00-ffH < >
00-44 00-ffH
Insert group number selection
00-44 00
Exit
99
Loading...