Argos 875/5292, 875/5340 User guide

Page 1
4 Double Hooks on a Board
Assembly Instructions - Please keep for future reference
875/5292
875/5340
Dimensions
Width - 45.7cm
Depth - 7cm
Height - 10.5cm
Important
– Please read these instructions fully before starting assembly
Issue 1 - 30/03/10
Page 2
Safety and Care Advice
Important –Please read these instructions fully before starting assembly
• Check you have all the components and tools listed on pages 2 .
• Remove all fittings from the plastic bags and separate them into their groups.
• Keep children and animals away from the work area, small parts could choke if swallowed.
• Make sure you have enough space to layout the parts before starting.
Care and maintenance
• Only clean using a damp cloth
and mild detergent, do no use bleach or abrasive cleaners.
• Do not stand or put weight on the product, this could cause damage.
• Assemble the item as close
to its final position (in the same
room) as possible.
• Assemble on a soft level surface to avoid damaging the
unit or your floor.
• From time to time check that
there are no loose screws on this unit.
• We do not recommend the use of power drill/drivers for
inserting screws, as this could damage the unit. Only use hand screwdrivers.
• Dispose of all packaging carefully and responsibly.
• This product should not be discarded with household
waste. Take to your local
authority waste disposal centre.
1
Page 3
Components - Panels
Please check you have all the panels listed below
Board (45.7x7cm)
1
If you have damaged or missing components, call the Customer Helpline: 08456 400800
Components - Fittings
Please check you have all the fittings listed below
Note: The quantities below are the correct amount to complete the assembly. In some cases more fittings may be supplied than are required.
A
D
Wall plug (for solid walls only) x 2
Hook x 4
B
10mm Bolt x 4
C
38mm Screw x 2
Tools required
Phillips screwdriver (medium)
Drill
6mm Suitable drill bit (for use with wall plug)
Ruler - Use this ruler to help correctly identify the screws
105
0 5 10 15 20 25 30 35 40 45 50
55 60
65 70 75 80
85 90 95 100
110 115 120 125 130 135 140 145 150
Small hammer
Eye protection (when using a hammer or glue)
165 170
155 160
2
Page 4
Assembly Instructions
Step 1
Fix the hooks
1
with bolt
Step 2
Fixing to wall
A
onto board
.
B
A
A
A
A
B
B
1
B
B
It is recommended that the
board is fixed to a wall.
Mark fixing hole on wall.
Drill 6mm hole and insert
wall plug
D
.
Warning:
Before drilling, check wall for
hidden pipes
and cables.
Insert the wall plug
D
into
the drilled holes , then take
C
wall screw
unit into wall plug
through the
D
.
Warning:
The Maximum
loading weight
is 10kg.
D
C
C
If you need help or have damaged or missing parts, call the Customer Helpline: 08456 400800
3
Page 5
A Guide to - Wall Mounting & Fixings
Important note:
If plastic wall plugs are supplied with your product:
- these are only suitable for use in masonry walls.
If you are in any doubt about the correct wall plugs for your wall, seek professional advice.
Failure of the product due to using incorrect xings is the responsibility of the installer.
Important: When drilling into walls always
check that there are no hidden wires or pipes etc.
Make sure that the screws and wall plugs being used are suitable for supporting your unit. Consult a qualified tradesperson if you are unsure.
Hints:
1: General rule: Always use a larger screw and wall plug
if you are not sure.
2: Ensure you use the recommended drill bit to match the wall
plug and hole size.
3: Ensure you drill the hole horizontally, do not force the drill or
enlarge the hole.
4: Take extra care when drilling high walls, ceilings and ceramic
tiles. Ensure wall plugs are inserted beyond the thickness of the ceramic tiles to avoid the tiles splitting or cracking.
5: Ensure wall plugs are well tted and are a tight t in the
drilled hole.
Types of walls
No.1 “General Purpose” wall plug
Generally aerated blocks should not be used to support heavy loads, use a specialist tting in this case. For light loads, general purpose wall plugs can be used.
No.2 “Plasterboard” wall plug
You can use one of the following types of wall plug if your walls are made of brick, breeze block, concrete, stone or wood.
No.3 “Cavity Fixing” wall plug
For use with plasterboard partitions or hollow wooden doors.
No.4 “Cavity Fixing-Heavy Duty”
wall plug
No.5 “Hammer Fixing” wall plug
For use with walls stuck with plasterboard. The hammer xing allows it to be xed to the wall rather than the plasterboard. Always check the xing is secure to the retaining wall.
No.6 “Shield Anchor” wall plug
Heavy loads
For use when attaching light loads on to plasterboard partitions.
Care & Maintenance
For use when tting or supporting heavy loads such as shelving, wall cabinets and coat racks.
Safety: Always check the fitting and location to ensure your safety in and around the home.
For use with heavier loads such as TV & HiFi speakers and satelite dishes etc.
Fitting: From time to time check the fitting to ensure the wall plugs or screws do not become loose.
Revision 2 - 7/10/09
Loading...