Mason
metal bunk
IMPORTANT - Retain these instructions for future reference
Spare Parts
www.argos-support.co.uk
0370 112 1928
Customer Support
0345 640 2020
Issue 1 - 23/06/21

A Guide to - Wall Mounting & Fixings
Important note:
If plastic wall plugs
are supplied with your
product:
- these are only suitable for
use in masonry walls.
If you are in any doubt about
the correct wall plugs for
your wall, seek professional
advice.
Failure of the product due to
using incorrect fxings is the
responsibility of the installer.
Important: When drilling into walls always
check that there are no hidden wires or pipes etc.
Make sure that the screws and wall plugs being used
are suitable for supporting your unit. Consult a qualifed
tradesperson if you are unsure.
Hints:
1: General rule: Always use a larger screw and wall plug
if you are not sure.
2: Ensure you use the recommended drill bit to match the wall
plug and hole size.
3: Ensure you drill the hole horizontally, do not force the drill or
enlarge the hole.
4: Take extra car e when drilling high walls, ceilings and ceramic
tiles. Ensure wall plugs are inserted beyond the thickness of
the ceramic tiles to avoid the tiles splitting or cracking.
5: Ensure wall plugs are well ftted and are a tight ft in the
drilled hole.
Types of walls
No.1 “General Purpose” wall plug
Generally aerated blocks should not
be used to support heavy loads, use
a specialist ftting in this case. For light
loads, general purpose wall plugs can
be used.
No.2 “Plasterboard” wall plug
You can use one of the following types of wall plug if your walls are made
of brick, breeze block, concrete, stone or wood.
No.3 “Cavity Fixing” wall plug
For use with plasterboard partitions or
hollow wooden doors.
No.4 “Cavity Fixing-Heavy Duty”
wall plug
No.5 “Hammer Fixing” wall plug
For use with walls stuck with
plasterboard. The hammer fxing allows
it to be fxed to the wall rather than the
plasterboard. Always check the fxing
is secure to the retaining wall.
No.6 “Shield Anchor” wall plug
Heavy loads
For use when attaching light loads on
to plasterboard partitions.
Care &
Maintenance
For use when ftting or supporting
heavy loads such as shelving, wall
cabinets and coat racks.
Safety: Always check the ftting
and location to ensure your safety
in and around the home.
For use with heavier loads such as TV
& HiFi speakers and satelite dishes etc.
Fitting: From time to time check
the ftting to ensure the wall plugs
or screws do not become loose.

Safety and Care Advice
Product Details
Silver 872/4072
White 853/5584
Black 859/3722
IMPORTANT – READ CAREFULLY – RETAIN FOR FUTURE REFERENCE
Keep children and animals
away from the work area, small
parts could choke if swallowed.
Make sure you have enough space
to layout the parts before
starting.
• This product has been
constructed to be used in the
domestic environment only and
not for commercial purposes.
Assemble the item as close
to its final position(in the same
room) as possible.
Assemble on a soft level
surface to avoid damaging the
unit or your floor.
We do not
recommend the
use of power
drill/drivers for
inserting screws
as this could damage the unit.
Only use hand screwdrivers.
Parts of the assembly will be
easier with 2 people.
Dispose of all packaging
carefully and responsibly.
Care and maintenance
Only clean using a damp cloth
and mild detergent. Do not use
abrasive cleaners.
Use a dry cloth to clean the
product, furniture polish is
not recommended.
• From time to time check that there
are no loose screws, nuts or bolts.
If there are please re-tighten.
This product should not be
discarded with household
waste. Take to your local
authority waste disposal
centre.
Additional Guidance
●
Assemble all parts and bolts loosely during assembly, only once the product is complete should you
fully tighten the bolts.Always follow the manufacturer's instruction.
● Regularly check and ensure that all bolts and fittings are tightend properly.
●
This product is tested to meet EN747-1:2012+A1:2015standards.
●
Please ensure that the mattress depth does not go past the permanent RED mark on the post/upper
Safety Barrier.
●
Maximum thickness of the mattress as determined under 18 CM as well as information regarding the
mattress maximum thickness marking. Recommended size of mattress(es): 191cm(L)x91cm(W).
●
WARNING:High beds and the upper bed of bunk beds are not suitable for children under six years due to
the risk of injury from falls.
●
WARNING:Bunk beds and high beds can present a serious risk of injury from strangulation if not used
correctly. Never attach or hang items to any part of the bunk bed that are not designed to be used with
the bed, for example, but not limited to ropes, strings, cords, hooks, belts and bags.
●
WARNING: Children can become trapped between the bed and the wall, a roof pitch, the ceiling, adjoining
pieces of furniture (e.g. cupboards) and the like. To avoid risk of serious injury the distance between the top
safety barrier and the adjoining structure shall not exceed 75mm or shall be more than 230mm.
●
WARNING: Do not place this child's bed near heat sources, windows and other funitures.
●
WARNING: Do not use this child's bed if any part is broken, torn or missing.
●
The ventilation of the room is necessary in order to keep the humidity low and to prevent mould in
and around the bed.
Made in (China) for Habitat. Argos Limited 489-499 Avebury Boulevard, Milton Keynes, MK9 2NW. Argos (N.I.) Ltd, Forestside
Shopping Centre, Upper Galwally, Belfast, United Kingdom, BT8 6FX. Argos Distributors (Ireland) Limited, Unit 7, Ashbourne
Retail Park, Ballybin Road, Ashbourne, County Meath, Ireland
1

Fittings (Shown to scale)
Bag 1
A x 4
55mm
Screw
I
x 1
Cap
B C x 4 x 4
30mm
Screw with
fitting
J
x
Screw
Screw with
wall plug
20mm
fitting
K
x 2
Plastic
D x 49
17mm
Screw
L
Strap
x 2
E 30
M6
Spring
washer
F x 16
13mm
Washer
Mx 4
45mm
Cap
G x 4
45mm
Cap
N x 4
45mm
Cap
H x 2
S=4
Allen
key
O
x 4
Screw
Tools required
Ruler/tape
measure
Mallet
Phillips screwdriver
(small & medium)
2

Components
1
HEADBOARD
(975 x 352mm)
4
SAFETY BARRIER (BACK )
(980 x 377mm)
7
SAFETY BARRIER (FRONT )
(970 x 377mm)
x 2
2
FOOTBOARD
(975 x 190mm)
SAFETY BARRIER (BACK )
5
(970 x 377mm)
8
SIDE RAIL (BACK)
(20 x 40 x980mm)
x 2
3
(305x958mm)
6
SAFETY BARRIER (FRONT )
(980 x 377mm)
9
SIDE RAIL BACK (BACK)
(20 x 40 x970mm)
10
SIDE RAIL
(20 x 40 x980mm)
13
BOTTPM HB/FB POST (LEFT)
( ø45x 500mm)
14
TOP HB/FB POST (RIGHT)
(ø45x 660mm)
15
BOTTOM HB/FB POST (RIGHT)
(ø45x 500mm)
16
CONNECTION TUBE
( ø45x 475mm)
(FRONT )
x4
x2
x2
x2
SIDE RAIL ( FRONT)
11
(20 x 40 x970mm)
17
LADDER
(908 x 350mm)
12
TOP HB/FB POST (LEFT)
( ø45x 660mm)
METAL SLATS
18
(25PCS TUBES WITH STRAP)x2
(1850 x 960mm)
x2
3

9
18
9
11
100
wood
NOTE:
Use tool to
make sure
the metal
slat heads
well fit into
the hole.
18
18
7
8

14
M
This bunk bed could be convertible to two single beds
A. PUT THE FOOT CAP TO THE LEG
N
N
B.YOU NEED DETACH THE CONNECTION TUBE FOR SINGLE BED.
M