![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg1.png)
TECHNICAL& SERVICE MANUAL
AWR508CL + AER508SCLA
AWR509CL + AER509SCLA
AFR509CL + AER509SCLA
SPLIT SYSTEM AIR CONDITIONER
AWR508CL
AWR509CL
AWR512CL
AER508SCLA
AER509SCLA
AER512SCLA
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg2.png)
i
Important!
Please Read Before Starting
This air conditioning system meets strict safety and
operating standards. As the installer or service person,
it is an important part of your job to install or service the
system so it operates safely and efficiently.
For safe installation and trouble-free operation, you
must:
●Carefully read this instruction booklet before
beginning.
●Follow each installation or repair step exactly as
shown.
●Observe all local, state, and national electrical codes.
●Pay close attention to all warning and caution notices
given in this manual.
This symbol refers to a hazard or
unsafe practice which can result
in severe personal injury or
death.
This symbol refers to a hazard or
unsafe practice which can result
in personal injury or product or
property damage.
If Necessary, Get Help
These instructions are all you need for most installation
sites and maintenance conditions. If you require help
for a special problem, contact our sales/service outlet
or your certified dealer for additional instructions.
In Case of Improper Installation
The manufacturer shall in no way be responsible for
improper installation or maintenance service, including
failure to follow the instructions in this document.
Special Precautions
When Wiring
ELECTRICAL SHOCK CAN CAUSE
SEVERE PERSONAL INJURY OR
DEATH. ONLY A QUALIFIED,
EXPERIENCED ELECTRICIAN SHOULD
ATTEMPT TO WIRE THIS SYSTEM.
• Do not supply power to the unit until all wiring and
tubing are completed or reconnected and checked.
• Highly dangerous electrical voltages are used in this
system. Carefully refer to the wiring diagram and
these instructions when wiring. Improper connections
and inadequate grounding can cause accidental
injury or death.
• Ground the unit following local electrical codes.
• Connect all wiring tightly. Loose wiring may cause
overheating at connection points and a possible fire
hazard.
When Transporting
Be careful when picking up and moving the indoor and
outdoor units. Get a partner to help, and bend your
knees when lifting to reduce strain on your back. Sharp
edges or thin aluminum fins on the air conditioner can
cut your fingers.
When Installing…
…In a Ceiling or Wall
Make sure the ceiling/wall is strong enough to hold the
units weight. It may be necessary to construct a strong
wood or metal frame to provide added support.
…In a Room
Properly insulate any tubing run inside a room to
prevent “sweating” that can cause dripping and water
damage to walls and floors.
…In Moist or Uneven Locations
Use a raised concrete pad or concrete blocks to
provide a solid, level foundation for the outdoor unit.
This prevents water damage and abnormal vibration.
…In an Area with High Winds
Securely anchor the outdoor unit down with bolts and a
metal frame. Provide a suitable air baffle.
…In a Snowy Area (for Heat Pump-type Systems)
Install the outdoor unit on a raised platform that is
higher than drifting snow. Provide snow vents.
When Connecting Refrigerant Tubing
• Use the flare method for connecting tubing.
• Apply refrigerant lubricant to the matching surfaces
of the flare and union tubes before connecting them,
then tighten the nut with a torque wrench for a leakfree connection.
• Check carefully for leaks before starting the test run.
When Servicing
• Turn the power off at the main power box (mains)
before opening the unit to check or repair electrical
parts and wiring.
• Keep your fingers and clothing away from any
moving parts.
• Clean up the site after you finish, remembering to
check that no metal scraps or bits of wiring have
been left inside the unit being serviced.
Others
• Ventilate any enclosed areas when installing or
testing the refrigeration system. Escaped refrigerant
gas, on contact with fire or heat, can produce
dangerously toxic gas.
• Confirm upon completing installation that no
refrigerant gas is leaking. If escaped gas comes in
contact with a stove, gas water heater, electric room
heater or other heat source, it can produce
dangerously toxic gas.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg3.png)
Table of Contents
Page
1 OPERATING RANGE 1
2 SPECIFICATIONS
2-1 Unit Specification 2
2-2 Major Component Specifications 7
2-3 Other Component Specifications 15
3 DIMENSIONAL DATA 18
4 REFRIGERANT FLOW DIAGRAM 21
5 PERFORMANCE DATA
5-1 Air Throw Distance Chart 23
5-2 Performance Charts 26
5-3 Cooling Capacity 29
6 ELECTRICAL DATA
6-1 Electrical Characteristic 34
6-2 Electric Wiring Diagrams 36
7 INSTALLATION INSTRUCTIONS
7-1 Installation Site Selection 39
7-2 Remote Control Unit Installation Position 41
7-3 Recommended Wire Length and Diameter 42
8 FUNCTION
8-1 Room Temperature Control 43
8-2 Dry Operation 44
8-3 Freeze prevention 45
8-4 Outdoor fan speed control 46
9 REFRIGERANT R407C:SPECIAL PRECAUTION WHEN SERVICING UNIT
9-1 Characteristics of new refrigerant R407c 47
9-2 Checklist before servicing 47
9-3 Tools specifically for R407c 48
9-4 For tubing installation procedures 48
9-5 In case of compressor malfunction 49
9-6 In case refrigerant is leaking 51
9-7 Charging additional refrigerant 53
9-8 Retro-fitting existing systems 53
10 TROUBLESHOOTING
10-1 Check before and after troubleshooting 54
10-2 Air Conditioner Does not operate 55
10-3 Some Parts of Air Conditioner does not operate 59
10-4 Air Conditioner Operates, but abnormalities are observed 61
10-5 If a sensor is defective 62
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg4.png)
11 CHECKING ELECTRICAL COMPONENTS
11-1 Measurements of insulation resistence 63
11-2 Checking continuity of fuse on PCB ass’y 64
11-3 Checking motor capacitor 64
12 DISASSEMBLY PROCEDURE FOR INDOOR UNIT
12-1 Removing air intake grille 65
12-2 Removing side panels 66
12-3 Access and removal of electrical components box 66
12-4 Removing flap motor 67
12-5 Removing evaporator 67
12-6 Removing fan and fan motor 69
APPENDIX Instructions manual 70
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg5.png)
1
1. OPERATING RANGE
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp.
Cooling
Maximum 32°C D.B. / 23°C W.B. 43°C D.B.
Minimum 19°C D.B. / 14°C W.B. -15°C D.B.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg6.png)
2
2. SPECIFICATIONS
2-1. Unit Specifications
Indoor Unit AWR508CL
Outdoor Unit AER508SCLA
Power Source 220–240V ~ 50Hz
Voltage rating 230 V
Performance Cooling
Capacity kW 2.05
BTU/h 6,991
Air circulation (High)
Moisture removal (High) Liters/h 0.4
Electrical Rating Cooling
Available voltage range V 198 ~ 264
Running amperes A 3.2
Power input W 680
Power factor % 92
C.O.P. W/W 3.01
Compressor locked rotor amperes A 17
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer ON/OFF 24 hours & Daily program,1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1(Hi)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R407c / 730
Refrigerant control Capillary tube
Operation sound Indoor : Hi / Me / Lo dB-A 37 / 32 / 31
Outdoor : Hi dB-A 43
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 9.52(3/8)
Refrigerant tube kit / Accessories Optional / Air Clean Filter
Dimensions & Weight Indoor Unit Outdoor Unit
Unit dimensions Height mm 270 540
Width mm 805 700
Depth mm 177 265
Package dimensions Height mm 243 568
Width mm 855 815
Depth mm 332 343
Weight Net kg 8.0 34.0
Shipping kg 10.0 37.0
Shipping volume
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are:
Cooling : Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg7.png)
3
Indoor Unit AWR509CL
Outdoor Unit AER509SCLA
Power Source 220–240V ~ 50Hz
Voltage rating 230 V
Performance Cooling
Capacity kW 2.55
BTU/h 8700
Air circulation (High)
Moisture removal (High) Liters/h 0.9
Electrical Rating Cooling
Available voltage range V 198 ~ 264
Running amperes A 4.4
Power input W 940
Power factor % 92
C.O.P. W/W 2.7
Compressor locked rotor amperes A 23
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer ON/OFF 24 hours & Daily program,1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1(Hi)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R407c / 800
Refrigerant control Capillary tube
Operation sound Indoor : Hi / Me / Lo dB-A 37 / 32 / 31
Outdoor : Hi dB-A 43
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 9.52(3/8)
Refrigerant tube kit / Accessories Optional / Air Clean Filter
Dimensions & Weight Indoor Unit Outdoor Unit
Unit dimensions Height mm 270 540
Width mm 805 700
Depth mm 177 265
Package dimensions Height mm 243 568
Width mm 855 815
Depth mm 332 343
Weight Net kg 8.0 36.0
Shipping kg 10.0 37.0
Shipping volume
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are:
Cooling : Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg8.png)
4
Indoor Unit AFR509CL
Outdoor Unit AER509SCLA
Power Source 220–240V ~ 50Hz
Voltage rating 230 V
Performance Cooling
Capacity kW 2.55
BTU/h 8700
Air circulation (High)
Moisture removal (High) Liters/h 0.7
Electrical Rating Cooling
Available voltage range V 198 ~ 264
Running amperes A 4.4
Power input W 940
Power factor % 92
C.O.P. W/W 2.7
Compressor locked rotor amperes A 23
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer ON/OFF 24 hours & Daily program,1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1(Hi)
Airflow direction (Indoor) Horizontal Manual
Vertical Manual
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R407c / 800
Refrigerant control Capillary tube
Operation sound Indoor : Hi / Me / Lo dB-A 37 / 32 / 31
Outdoor : Hi dB-A 43
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 9.52(3/8)
Refrigerant tube kit / Accessories Optional / Air Clean Filter
Dimensions & Weight Indoor Unit Outdoor Unit
Unit dimensions Height mm 700 540
Width mm 560 700
Depth mm 200 265
Package dimensions Height mm 770 568
Width mm 620 815
Depth mm 265 343
Weight Net kg 18 36.0
Shipping kg 20 37.0
Shipping volume
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are:
Cooling : Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg9.png)
5
Indoor Unit AWR512CL
Outdoor Unit AER512SCLA
Power Source 220–240V ~ 50Hz
Voltage rating 230 V
Performance Cooling
Capacity kW 3.30
BTU/h 11400
Air circulation (High)
Moisture removal (High) Liters/h 1.3
Electrical Rating Cooling
Available voltage range V 198 ~ 264
Running amperes A 6.5
Power input W 1380
Power factor % 92
C.O.P. W/W 2.4
Compressor locked rotor amperes A 33
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer ON/OFF 24 hours & Daily program,1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1(Hi)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R407c / 750
Refrigerant control Capillary tube
Operation sound Indoor : Hi / Me / Lo dB-A 39 / 35 / 33
Outdoor : Hi dB-A 45
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 12.7(1/2)
Refrigerant tube kit / Accessories Optional / Air Clean Filter
Dimensions & Weight Indoor Unit Outdoor Unit
Unit dimensions Height mm 270 540
Width mm 805 700
Depth mm 177 265
Package dimensions Height mm 243 568
Width mm 855 815
Depth mm 332 343
Weight Net kg 8.0 37.0
Shipping kg 10.0 40.0
Shipping volume
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are:
Cooling : Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bga.png)
6
Indoor Unit FCR512CL
Outdoor Unit AER512SCLA
Power Source 220–240V ~ 50Hz
Voltage rating 230 V
Performance Cooling
Capacity kW 3.30
BTU/h 11400
Air circulation (High)
Moisture removal (High) Liters/h 1.30
Electrical Rating Cooling
Available voltage range V 198 ~ 264
Running amperes A 6.5
Power input W 1.380
Power factor % 92
C.O.P. W/W 2.4
Compressor locked rotor amperes A 33
Features
Controls / Temperature control Microprocessor / I.C. thermostat
Control unit Wireless remote control unit
Timer ON/OFF 24 hours & Daily program,1-hour OFF
Fan speeds Indoor / Outdoor 3 and Auto / 1(Hi)
Airflow direction (Indoor) Horizontal Manual
Vertical Auto
Air filter Washable, Anti-Mold
Compressor Rotary (Hermetic)
Refrigerant / Amount charged at shipment g R407c / 750
Refrigerant control Capillary tube
Operation sound Indoor : Hi / Me / Lo dB-A 39 / 35 / 33
Outdoor : Hi dB-A 45
Refrigerant tubing connections Flare type
Max. allowable tubing length at shipment m 7.5
Refrigerant Narrow tube mm (in.) 6.35(1/4)
tube diameter Wide tube mm (in.) 12.7(1/2)
Refrigerant tube kit / Air Clean Filter Optional / Optional
Dimensions & Weight
Outdoor Unit
Unit dimensions Height mm 680 530
Width mm 900 750
Depth mm 190 270
Package dimensions Height mm 813 593
Width mm 1,011 895
Depth mm 296 348
Weight Net kg 23.5 35.5
Shi pp in g kg 30.0 38.0
Shipping volume
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Remarks:
Rating conditions are:
Cooling : Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bgb.png)
7
2-2. Major Component Specifications
2-2-1. Indoor Unit
Indoor Unit AWR508CL
Controller PCB
Part No. POW-K8E(A), POW-K8E(B)
Controls Microprocessor
Control circuit fuse 250 V 3.15 A
Remote Control Unit RCS-8PS3E
Fan & Fan Motor
Type Cross-flow
Q'ty ... Dia. and length mm 1 ... ø95 / L617
Fan motor model ... Q'ty KFV4Q-11H5P-S ... 1
No. of poles ... rpm (230 V, High) 4 ... 1,130
Nominal output W 10
Coil resistance (Ambient temp. 20°C) Ω BRN-WHT : 561.8
VLT-WHT : 197.4
VLT-ORG : 63.4
YEL-ORG : 155.7
YEL-PNK : 115.9
Safety devices Type Internal fuse
Operating temp. Open °C 145±2
Close —
Run capacitor µF 0.6
VAC 440
Flap Motor
Type Stepping motor
Model MP24GA1
Rating DC 12 V
Coil resistance (Ambient temp. 25°C) Ω WHT – BLU (respectively 4 wires) : 380 ± 7%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.4
Face area
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bgc.png)
Controller PCB
Part No. POW-K8E(A), POW-K8E(B)
Controls Microprocessor
Control circuit fuse 250 V 3.15 A
Remote Control Unit RCS-8PS3E
Fan & Fan Motor
Type Cross-flow
Q'ty ... Dia. and length mm 1 ... ø95 / L617
Fan motor model ... Q'ty KFV4Q-11H5P-S ... 1
No. of poles ... rpm (230 V, High) 4 ... 1,190
Nominal output W 10
Coil resistance (Ambient temp. 20°C) Ω BRN-WHT : 561.8
VLT-WHT : 197.4
VLT-ORG : 63.4
YEL-ORG : 155.7
YEL-PNK : 115.9
Safety devices Type Internal fuse
Operating temp. Open °C 145±2
Close —
Run capacitor µF 0.8
VAC 440
Flap Motor
Type Stepping motor
Model MP24GA1
Rating DC 12 V
Coil resistance (Ambient temp. 25°C) Ω WHT – BLU (respectively 4 wires) : 380 ± 7%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.4
Face area
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bgd.png)
Controller PCB
Part No. POW-K8E(A), POW-K8E(B)
Controls Microprocessor
Control circuit fuse 250 V 3.15 A
Remote Control Unit RCS-8PS3E
Fan & Fan Motor
Type Cross-flow
Q'ty ... Dia. and length mm 1 ... ø95 / L617
Fan motor model ... Q'ty KFV4Q-11H5P-S ... 1
No. of poles ... rpm (230 V, High) 4 ... 1,230
Nominal output W 10
Coil resistance (Ambient temp. 20°C) Ω BRN-WHT : 561.8
VLT-WHT : 197.4
VLT-ORG : 63.4
YEL-ORG : 155.7
YEL-PNK : 115.9
Safety devices Type Internal fuse
Operating temp. Open °C 145±2
Close —
Run capacitor µF 1.0
VAC 440
Flap Motor
Type Stepping motor
Model MP24GA1
Rating DC 12 V
Coil resistance (Ambient temp. 25°C) Ω WHT – BLU (respectively 4 wires) : 380 ± 7%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.4
Face area
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bge.png)
Controller PCB
Part No. POW-K185GS5-N
Controls Microprocessor
Control circuit fuse 250 V 3 A
Remote Control Unit RCS-5PS3E
Fan & Fan Motor
Type Cross-flow
Q'ty ... Dia. and length mm 1 ... ø100 / L410
Fan motor model ... Q'ty KR35406M01527
No. of poles ... rpm (230 V, High) 4 ... 1,140
Nominal output W 27
Coil resistance (Ambient temp. 20°C) Ω GRY-WHT : 545 - 630
WHT-VLT : 92 - 105
VLT-YEL : 62 - 71
BRN-YEL : 78 - 90
——
Safety devices Type Internal protector
Operating temp. Open °C 150±10
Close Automatic reclosing
Run capacitor µF 0.6
VAC 400
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.4
Face area
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bgf.png)
Controller PCB
Part No. POW-K185GS-N
Controls Microprocessor
Control circuit fuse 250 V 3 A
Remote Control Unit RCS-5PS3E
Fan & Fan Motor
Type Cross-flow
Q'ty ... Dia. and length mm 2 ... ø130 / L180
Fan motor model ... Q'ty K48407-M01416 ... 1
No. of poles ... rpm (230 V, High) 4 ... 1,160
Nominal output W 20
Coil resistance (Ambient temp. 20°C) Ω GRY-WHT : 311±7%
WHT-VLT : 97.6±7%
VLT-YEL : 97.6±7%
WHT-PNK : 425±7%
——
Safety devices Type Internal protector
Operating temp. Open °C 145±5
Close Automatic reclosing
Run capacitor µF 1.5
VAC 440
Flap Motor
Model M2LJ24ZE31
Rating AC 208 / 230 V, 50 / 60 Hz
No. of poles ... rpm 8 ... 2.5 / 3.0
Nominal output W 3 / 2.5
Coil resistance (Ambient temp. 20°C) kΩ 16.45 ± 15%
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 2
Fin pitch mm 1.8
Face area
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg10.png)
12
2-2-2. Outdoor Unit
Outdoor Unit AER508SCLA
Compressor
Type Rotary (Hermetic)
Compressor model C-1RN60H5C 802-060-35B
Nominal output W 600
Compressor oil ... Amount cc DAPHNE FV68S ... 350
Coil resistance (Ambient temp. 25°C) Ω C–R : 4.66
C–S : 8.89
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA38072-3229 CS-7C115
Operating temp. Open °C 145±5 115±3
Close °C 69±11 95±5
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 13A —
Run capacitor µF 17.5
VAC 450
Crank case heater —
Fan & Fan Motor
Type Propeller
Q'ty ... Dia. 1 ... ø370
Fan motor model ... Q'ty KR35410M01846 ... 1
No. of poles ... rpm (230 V, High) 6 ... 770
Nominal output W 20
Coil resistance (Ambient temp. 25°C) Ω BLK-WHT : 211-242 / WHT-VLT : 244-281
VLT-YEL: 83.5-96.1 / BLK-PNK : 41.7-48
Safety devices Type Internal fuse
Operating temp. Open °C 150±10
Close °C —
Run capacitor µF 1.5
VAC 450
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 1
Fin pitch mm 1.3
Face area
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg11.png)
13
Outdoor Unit AER509SCLA
Compressor
Type Rotary (Hermetic)
Compressor model C-RN80H5A 802-282-45G
Nominal output W 800
Compressor oil ... Amount cc DAPHNE FV68S ... 470
Coil resistance (Ambient temp. 25°C) Ω C–R : 3.070
C–S : 7.97
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA38066-3229 CS-7C115
Operating temp. Open °C 150±5 115±3
Close °C 69±11 95±5
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 16A —
Run capacitor µF 22.5
VAC 450
Crank case heater —
Fan & Fan Motor
Type Propeller
Q'ty ... Dia. 1 ... ø370
Fan motor model ... Q'ty KR35410M01846 ... 1
No. of poles ... rpm (230 V, High) 6 ... 800
Nominal output W 56
Coil resistance (Ambient temp. 25°C) Ω BLK-WHT : 211-242 / WHT-VLT: 244-281
VLT-YEL : 83.5-96.1 / BLK-PNK: 41.7-48
Safety devices Type Internal fuse
Operating temp. Open °C 150±10
Close °C —
Run capacitor µF 1.5
VAC 450
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 1
Fin pitch mm 1.3
Face area
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg12.png)
14
Outdoor Unit AER512SCLA
Controller PCB
Part No. POW-CLR128E
Control circuit fuse 250 V 3.15 A
Compressor
Type Rotary (Hermetic)
Compressor model C-R110H5HB 80235645B-S
Nominal output W 1,100
Compressor oil ... Amount cc DAPHNE FV68S ... 510
Coil resistance (Ambient temp. 25°C) Ω C–R : 1.962
C–S : 5.38
Safety devices Type External(OLR A) External(OLR T)
Overload relay MRA98596-9201 CS-7C115
Operating temp. Open °C 150±5 115±3
Close °C 69±11 95±5
Operating amp.(Ambient temp. 25°C) Trip in 6 to 16 sec. at 21A —
Run capacitor µF 25.0
VAC 400
Crank case heater 240 V 20 W
Fan & Fan Motor
Type Propeller
Q'ty ... Dia. 1 ... ø400
Fan motor model ... Q'ty KR35410M01846 ... 1
No. of poles ... rpm (230 V, High) 6 ... 770
Nominal output W 20
Coil resistance (Ambient temp. 25°C) Ω BLK-WHT : 211-242
WHT-VLT : 244-281
VLT-YEL : 83.5-96.1
BLK-PNK : 41.7-48.0
Safety devices Type Internal fuse
Operating temp. Open °C 145±2
Close °C —
Run capacitor µF 2.0
VAC 450
Heat Exch. Coil
Coil Aluminum plate fin / Copper tube
Rows 1
Fin pitch mm 1.3
Face area
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg13.png)
2-3. Other Component Specifications
115
Outdoor Unit AER508SCLA
AER509SCLA
AER512SCLA
Thermistor (Room sensor) DTN-TKS134B
Resistance kΩ 25°C 5.0 ± 3%
Thermistor (Coil sensor) DTN-TKS131B
Resistance kΩ 0°C 15.0 ± 2%
Transformer (TR) ATR-J105
Rating Primary AC 230V, 50/60Hz
Secondary 19V, 0.526A
Capacity 10VA
Coil resistance Ω (at 21°C) Primary (WHT – WHT): 205 ± 10%
Secondary (BRN – BRN): 2.0 ± 10%
Thermal cut-off temp. 150°C
Indoor Unit AWR508CL
AWR509CL
AWR512CL
Thermistor (Coil sensor TH1) PBC–41E–S4
Resistance kΩ –20°C 40.1± 5% 20°C 6.5± 5%
–10°C 24.4± 5% 30°C 4.4± 5%
0°C 15.3± 5% 40°C 3.0± 5%
10°C 9.9± 5% 50°C 2.1± 5%
Power Relay (PR) G7L-2A-TUB
Coil rating AC 200–240V, 50/60Hz
Coil resistance Ω (at 23°C) 21 ± 15%
Contact rating AC 220V, 25A
Transformer (TR2) ATR-J65
Rating Primary AC 230V, 50Hz
Secondary 19V, 0.315A
Capacity 6VA
Coil resistance Ω (at 22°C) Primary (WHT – WHT): 455 ± 10%
Secondary (BRN – BRN): 2.85 ± 10%
Thermal cut-off temp. 145°C
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg14.png)
Transformer (TR) ATR-H85
Rating Primary AC 235V, 50Hz
Secondary 11V, 0.727A
Capacity 8VA
Coil resistance Ω (at 21°C) Primary (WHT – WHT): 214 ± 10%
Secondary (BRN – BRN): 1.58 ± 10%
Thermal cut-off temp. 145°C, 2A, 250V
Thermistor (Coil sensor TH1) DHPBC-41ES-14N
Resistance kΩ –20°C40.1 ±5%
–10°C24.4 ±5%
0°C15.3 ±5%
-10°C9.9 ±5%
Thermistor (Room sensor TH2) DHKTEC-35-S6N
Resistance kΩ -20°C 10 ±5%
-10° 7.9 ±5%
-20°C6.3 ±5%
-10°C5.0 ±5%
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg15.png)
Transformer (TR) ATR-H85
Rating Primary AC 230V, 50/60Hz
Secondary 11V, 0.727A
Capacity 8VA
Coil resistance Ω (at 21°C) Primary (WHT – WHT): 214 ± 10%
Secondary (BRN – BRN): 1.58 ± 10%
Thermal cut-off temp. 145°C, 2A, 250V
Thermistor (Coil sensor TH1) PBC-41E-S14
Resistance kΩ –20°C 40.1 ± 5% 20°C 6.5 ± 5%
–10°C 24.4 ± 5% 30°C 4.4 ± 5%
0°C 15.3 ± 5% 40°C 3.0 ± 5%
10°C 9.9 ± 5% 50°C 2.1 ± 5%
Thermistor (Room sensor TH2) KTEC-35-S6
Resistance kΩ 10°C 10.0 ± 4% 30°C 4.0 ± 4%
15°C 7.9 ± 4% 35°C 3.3 ± 4%
20°C 6.3 ± 4% 40°C 2.7 ± 4%
25°C 5.0 ± 4% 50°C 1.8 ± 4%
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg16.png)
18
3. DIMENSIONAL DATA
Indoor Unit FCR512CL
Remote control unit
86
74 74
Center of tubing hole
ø75 (4 places)
Wide tube ø12.7 (1/2")
Narrow tube ø6.35 (1/4")
Drain hose ø26
74 74
900
86
41
41
190
680
18.5
61
172.5
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg17.png)
19
Indoor Unit AWR508CL
AWR509CL
AWR512CL
58.599.5
805 177
41.0
41.0 270
Narrow tube ø6.35 (1/4")
Wide tube ø9.52 (3/8") AWR508,AWR509
Wide tube ø12.7 (1/2") AWR512
Center of tubing
hole (2 places)
Drain hose ø18
Remote control unit
18.5
61
172.5
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg18.png)
20
Outdoor Unit AER508SCLA
AER509SCLA
AER512SCLA
700
540
15
255
Narrow tube service valve
ø6.35 (1/4")
Wide tube service valve
ø9.52 (3/8")
ø12.7 (1/2")
170
103 57
470
4 – ø12 holes
116
320
294
Air intake
Air discharge
AER508,AER509
AER512
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg19.png)
4. REFRIGERANT FLOW DIAGRAM
21
Indoor Unit
AWR508CL
AWR509CL
Compressor
Accumulator
Wide tube
service
valve
Wide tube
O.D.
ø9.52 mm
(3/8 ")
Narrow
tube
service
valve
Narrow tube
O.D.
ø6.35 mm
(1/4")
Condenser
Capillary tube
Indoor Unit Outdoor Unit
Evaporator
Muffler
Indoor Unit AWR512CL Outdoor Unit AER512SCLA
Compressor
Accumulator
Wide tube
service
valve
Wide tube
Narrow
tube
service
valve
Narrow tube
O.D.
ø6.35 mm
(1/4")
Condenser
Capillary tube
Indoor Unit Outdoor Unit
Evaporator
Muffler
O.D.
ø12.7 mm
(1/2 ")
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg1a.png)
22
Insulation of Refrigerant Tubing
Because capillary tubing is used in the outdoor unit, both the
wide and narrow tubes of this air conditioner become cold. To
prevent heat loss and wet floors due to dripping of
condensation, both tubes must be well insulated with a
proper insulation material. The thickness of the insulation
should be a min. 8 mm.
After a tube has been insulated,
never try to bend it into a narrow
curve because it can cause the tube
to break or crack.
Wide tube
Thickness:
Min. 8 mm
Insulation
Narrow tube
Thickness:
Min. 8 mm
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg1b.png)
5. PERFORMANCE DATA
5-1. Performance charts
23
Indoor inlet air
D.B. temp. (°C)
1.38 (13)
1.28 (12)
1.18 (11)
1.08 (10)
0.98 ( 9 )
0.89 ( 8 )
0.79 ( 7 )
0.69 ( 6 )
25 30 35 40 45 50
Outdoor inlet air D.B. temp. (°C)
Low pressure at wide tube service valve MPa (kgf/cm
2
G)
0.59 ( 5 )
0.49 ( 4 )
0.39 ( 3 )
■ Cooling Characteristics
9
8
7
6
5
4
3
2
1
25 30 35 40 45 50
Outdoor inlet air D.B. temp. (°C)
Operating current (A)
10
Indoor inlet air
D.B. temp. (°C)
32
27
19.4
32
27
19.4
32
27
19.4
● ...... Points of Rating condition
Black dots in above charts indicate the following rating conditions.
Cooling: Indoor air temperature 27°C D.B./19°C W.B.
Outdoor air temperature 35°C D.B./24°C W.B.
Indoor Unit AWR508CL
Outdoor Unit AER508SCLA
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg1c.png)
Indoor inlet air
D.B. temp. (°C)
1.38 (13)
1.28 (12)
1.18 (11)
1.08 (10)
0.98 ( 9 )
0.89 ( 8 )
0.79 ( 7 )
0.69 ( 6 )
25 30 35 40 45 50
Outdoor inlet air D.B. temp. (°C)
Low pressure at wide tube service valve MPa (kgf/cm
2
G)
0.59 ( 5 )
0.49 ( 4 )
0.39 ( 3 )
■ Cooling Characteristics
9
8
7
6
5
4
3
2
1
25 30 35 40 45 50
Outdoor inlet air D.B. temp. (°C)
Operating current (A)
10
Indoor inlet air
D.B. temp. (°C)
32
27
19.4
32
27
19.4
● ...... Points of Rating condition
Black dots in above charts indicate the following rating conditions.
Cooling: Indoor air temperature 27°C D.B./19°C W.B.
Outdoor air temperature 35°C D.B./24°C W.B.
Indoor Unit AWR509CL AFR509CL
Outdoor Unit AER509SCLA
![](/html/e4/e4bb/e4bb9adbc590ae2a48092ec76aff4fa5ce2211cefb6326f317face7ae2757c71/bg1d.png)
Indoor inlet air
D.B. temp. (°C)
1.38 (13)
1.28 (12)
1.18 (11)
1.08 (10)
0.98 ( 9 )
0.89 ( 8 )
0.79 ( 7 )
0.69 ( 6 )
25 30 35 40 45 50
Outdoor inlet air D.B. temp. (°C)
Low pressure at wide tube service valve MPa (kgf/cm
2
G)
0.59 ( 5 )
0.49 ( 4 )
0.39 ( 3 )
■ Cooling Characteristics
11
10
9
8
7
6
5
4
3
25 30 35 40 45 50
Outdoor inlet air D.B. temp. (°C)
Operating current (A)
12
Indoor inlet air
D.B. temp. (°C)
32
27
19.4
32
27
19.4
● ...... Points of Rating condition
Black dots in above charts indicate the following rating conditions.
Cooling: Indoor air temperature 27°C D.B./19°C W.B.
Outdoor air temperature 35°C D.B./24°C W.B.
Indoor Unit AWR512CL FCR512CL
Outdoor Unit AER512SCLA