Encapsulated AC-DC Converter
ASC SERIES 30 Watts
KEY FEATURES
Switching Power Modules for PCB Mounting
Fully Encapsulated Plastic Case
Universal Input Range 90-260VAC, 47-440 Hz
Regulated Output
Low Ripple and Noise
High Efficiency
CE, cUL, TUV, CB Approvals
2-Year Product Warranty
ELECTRICAL SPECIFICATIONS
Model No. ( Single Output ) ASC-3.3S ASC-5S ASC-12S ASC-15S ASC-24S
Max output wattage (W)
Voltage
Frequency (Hz)
Input
Output
Protection
Isolation
Environment
Physical
Safety Agency approvals
EMC
Current (Full load)
Inrush current (<2ms)
Leakage Current
External fuse (recommend)
Voltage (V.DC.)
Voltage accuracy
Current (mA) max
Line regulation (typ.)
Load regulation (5-00%) (typ.)
Minimum load
Maximum capacitive load
Ripple & Noise
Efficiency
Hold-up time
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Input-Output (V.AC)
Operating temperature
Storage temperature
Temperature coefficient
Humidity
MTBF >200,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
Case Material
Weight
Cooling method
EMI (Conducted & Radiated Emission)
(Noise Immunity)
EMS
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
20W 30W 30W 30W 30W
90-260 VAC or 120-370 VDC
47-440 Hz
520 mA max. (115 VAC) / 320 mA max. (230 VAC)
10 A max. (115 VAC) /20 A max. (230 VAC)
0.75 mA max.
1.5 A slow blow type
3.3V 5V 12V 15V 24V
±2% ±2% ±2% ±2% ±2%
6000 6000 2500 2000 1250
±1% ±1%. ±1% ±1% ±1%
±1% ±1% ±1% ±1% ±1%
5% 4% 2% 2% 2%
470-23,000µF depending on model
<0.5% Vout +50mV max (Vp-p)
73% 80% 84% 84% 84%
15 ms min.
100 kHz 100 kHz 100 kHz 100 kHz 100 kHz
Hiccup technique, auto-recovery
Zener diode clamp
Hiccup mode, indefinite (automatic recovery)
3000 V 3000 V 3000 V 3000 V 3000 V
-25°C…+71°C
-40°C…+85°C
0.02%/°C 0.02%/°C 0.02%/°C 0.02%/°C 0.02%/°C
95% RH
3.5 x 2.5 x 0.98 Inches (89.0 x 63.5 x 25.0 mm)
Plastic resin + Fiberglass (flammability to UL 94V-0)
220 g
Free air convection
UL/cUL, CE, TUV, CB
EN 55022 class B
EN 55024
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
Encapsulated AC-DC Converter
ASC SERIES 30 Watts
ELECTRICAL SPECIFICATIONS
Model No. ( Dual, Triple Output ) ASC-5D ASC-12D ASC-15D ASC-5S12S ASC-5S12D ASC-5S15D
Max output wattage (W)
Voltage
Frequency (Hz)
Input
Output
Protection
Isolation
Environment
Physical
Safety Agency approvals
EMC
Current (Full load)
Inrush current (<2ms)
Leakage Current
External fuse (recommend)
Voltage (V.DC.)
Voltage accuracy
Current (mA) max
Line regulation (typ.)
Load regulation (5-100%) (typ.)
Minimum load
Maximum capacitive load
Ripple & Noise
Efficiency
Hold-up time
Switching frequency
Over current protection
Over voltage protection
Short circuit protection
Input-Output (V.AC)
Operating temperature
Storage temperature
Temperature coefficient
Humidity
MTBF >200,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
Case Material
Weight
Cooling method
EMI (Conducted Emission)
EMS (Radiated Emission)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
30W 30W 30W 30W 30W 30W
90-260 VAC or 120-370 VDC
47-440 Hz
520 mA max. (115 VAC) / 320 mA max. (230 VAC)
10 A max. (115 VAC) /20 A max. (230 VAC)
0.75 mA max.
1.5 A slow blow type
±5V ±12V ±15V 5/12 5/±12 5/±15
±2% ±2% ±2% ±2% ±2% ±2%
±3000 ±1250 ±1000 3000/1250 3000/±630 3000/±500
±1% ± 1% ± 1% ±1%/±5% ±1%/±5% ±1%/±5%
±3% ±3% ±3% ±3%/±6% ±2%/±6% ±2%/±6%
2% 3% 1% 20% 20% 20%
470-23,000µF depending on model
<0.5% Vout +50mV max (Vp-p)
80% 84% 84% 80% 80% 80%
15 ms min.
100 kHz 100 kHz 100 kHz 100 kHz 100 kHz 100 kHz
Hiccup technique, auto-recovery
Zener diode clamp
Hiccup mode, indefinite (automatic recovery)
3000 V 3000 V 3000 V 3000 V 3000 V 3000 V
-25°C…+71°C
-40°C…+85°C
0.02%/°C 0.02%/°C 0.02%/°C 0.02%/°C 0.02%/°C 0.02%/°C
95% RH
3.5 x 2.5 x 0.98 Inches (89.0 x 63.5 x 25.0 mm)
Plastic resin + Fiberglass (flammability to UL 94V-0)
220 g
Free air convection
UL/cUL, CE, TUV, CB
EN 55022 class B
EN 55024
Note
1. The triple output required a minimum 20% loading on the output to maintain specified regulation. Operation under no-load condition will
not damage these devices; however they may not meet all listed specification.
2. Load regulation for triple output:
Main output (V1): 20% to 100% with 20% to 100% balanced on auxiliaries.
Auxiliary outputs (V2 and V3): 20% to 100% balanced on all outputs.
3. Cross regulation for triple output:
Main output 100% load, auxiliary 100%, other auxiliary 25% to 100%.
Auxiliary outputs (V2 and V3): Main output 100% load, auxiliary 100%, other auxiliary 25% to 100% or main output 25%, auxiliary 25%,
other auxiliary 25% to 100%.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-