Thank you for purchasing our Portable Air Conditioner.
Before using your air conditioner, please read this instruction manual
carefully and keep it for future reference.
Warranty And Return Policy.................................................................................................................. 16
Preparation
control panel
remote signal receptor
horizontal louver control
lever(adjust manually)
NOTE: PHA can not be
adjusted.
vertical louver control
lever(adjust manually)
NOTE: PHA can not be
adjusted.
panel
front
handle
(both sides)
air filter
(behind the grille)
upper air intake
drain outlet
air outlet
lower air intake
Caster
bottom tray
drain outlet
rear
Safety Precautions
Please read through these instructions before you start the installation process.
Improper installation can cause damage to the unit, your personal property, and
also poses a personal safety hazard.
-Installation must be performed according to the installation instructions. Improper installation
can cause water leakage, electrical shock, or fire.
-Use only the included accessories and parts, and specified tools for the installation. Using
non-standard parts can cause water leakage, electrical shock, fire, and injury or property
damage.
-Make sure that the outlet you are using is grounded and has the appropriate voltage. The
power cord is equipped with a three-prong grounding plug to protect against shock. Voltage
information can be found on the side of the unit, behind the grille.
-Install the unit in on a flat, sturdy surface. Failure to do socould result in damage or excessive
noise and vibration.
-The unit must be kept free from obstruction to ensure proper function and to mitigate safety
hazards.
-DO NOT modify the length of the power cord or use an extension cord to power the unit.
DO NOT share a single outlet with other electrical appliances. Improper power supply can
cause fire or electrical shock.
-DO NOT install your air conditioner in a wet room such as a bathroom or laundry room. Too
much exposure to water can cause electrical components to short circuit.
-DO NOT install the unit in a location that may be exposed to combustible gas, as this could
cause fire.
-The unit has wheels to facilitate moving. Make sure not to use the wheels on thick carpet or
to roll over objects, as these could cause tipping.
-DO NOT operate a unit that has been dropped or damaged.
-Only use the included accessories and specified parts for installation. Using nonstandard
parts can cause water leakage, electrical shock, fire, and injury or property damage.
-The unit must be kept free from obstruction to ensure proper function.
-DO NOT allow children to play with the air conditioner. Children must be supervised around
the unit at all times.
-If the air conditioner is knocked over during use, turn off the unit and unplug it from the main
power supply immediately. Visually inspect the unit to ensure there is no damage. If you
suspect the unit has been damaged, contact a technician or customer service for assistance.
-In a thunderstorm, the power must be cut off to avoid damage to the machine due to lightning.
Cautions
-This appliance can be used by children aged from 8 years and above and person with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand the
hazards involved. Children shall not play the appliance. Cleaning and user maintenance shall not
be made by children without supervision. (be applicable for the European Countries)
-This appliance is not intended for use by persons (including childern) with reduced physical,
sensory or mental capabilities or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
(be applicable for other countries except the European Countries )
-Children should be supervised to ensure that they do not play with the appliance.
-If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or
similarly qualified persons in order to avoid a hazard.
-Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
-Do not install the appliance in a location that may be exposed to combustible gas.
-If combustible gas accumulates around the unit, it may cause fire.
-Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar coverings.
-Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it
will not be tripped over.
-Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized
service facility for examination and/or repair.
-To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control
device.
-The appliance shall be installed in accordance with national wiring regulations.
-Contact the authorised service technician for repair or maintenance of this unit.
-Contact the authorised installer for installation of this unit.
-When there are wide differences between "USER' S MANUAL" and "Remote controller
Illustration" on function description, the description on "USER' S MANUAL " shall prevail.
-Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
Choosing The Right Location
Installation
Your installation location should meet the following
requirements:
-Make sure that you install your unit on an even
surface to minimize noise and vibration.
-The unit must be installed near a grounded plug,
and the Collection Tray Drain (found on the back
of the unit) must be accessible.
-The unit should be located at least 30cm (12”) from
the nearest wall to ensure proper air conditioning.
-DO NOT cover the Intakes, Outlets or Remote
Signal Receptor of the unit, as this could cause
damage to the unit.
Note About Fluorinated Gasses
-This air-conditioning unit is a hermetically sealed unit that contains fluorinated gasses.
For specific information on the type of gas and the amount, please refer to the relevant label
on the unit itself.
-Installation, service, maintenance and repair of this unit must be performed by a certified
technician.
-Product uninstallation and recycling must be performed by a certified technician.
-If the system has a leak-detection system installed, it must be checked for leaks at least
every 12 months.
-When the unit is checked for leaks, proper record-keeping of all checks is strongly
recommended.
NOTE:
All the illustrations in the manual are for explanation purpose only. Your machine may be
slightly different. The actual shape shall prevail.The unit can be controlled by the unit control
panel alone or with the remote controller. This manual does not include Remote Controller
Operations, see the <<Remote Controller Instruction>> packed with the unit for details.
Loading...
+ 12 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.