Aquatherm 16104-8, 10001-2, 10204-12, 10001-5, 16204-12 User Manual

...
INDUSTRIES INCORPORATED
• SAVE INSTALLATION TIME AND AVOID CALL-BACKS •
• READ THIS MANUAL BEFORE MOUNTING COLLECTORS •
SWIMMING POOL
SOLAR HEATING SYSTEMS
INSTALLATION MANUAL FOR
AQUATHERM INDUSTRIES
SOLAR COLLECTORS
FOR MODEL NUMBERS:
10001-5 10001-2 10001-1
MANUAL CONTENTS
This manual provides a detailed step-by-step pro­cedure for the installation of an Aquatherm Industries solar pool heating system. If the direc­tions are followed correctly and only recommended Aquatherm Industries hardware and components are used, the installed system should provide years of trouble free service, savings, and enjoyment.
10204-12 10204-10 10204-8
16104-12 16104-10 16104-8
16204-12 16204-10 16204-8
MOUNTING COMPONENTS DIAGRAM
MOUNTING COMPONENTS
This section provides descriptions and part numbers of the Aquatherm Industries Installation Kits required for each solar pool heating system. The mounting location of each kit component is shown by the corresponding circled num­ber in the ‘Mounting Components’diagram, shown above.
1
The Collector Installation Kit (Part #12034-1 for 1 1/2” kit;
#12034-2 for 2” kit) contains the parts needed to fasten a single solar collector to a supporting surface and to make water connec­tions from one collector to another. Hold-down strap is not includ­ed and must be ordered separately Use one (1) kit per collector.
Part No Qty 1 1/2” Qty 2” Description
10008-1 1 10008-2 50006 2 2 Hold-down strap bracket 60001-1 2 60002-1 60546-1 4 60546-2
__
__ __
__
Outlet header hold-down bracket assembly
1 Outlet header hold-down bracket assembly
__
Collector connector hose (3 3/4” long)
2 Collector connector hose (3 3/4” long)
__
Hose clamp, stainless steel
4 Hose clamp, stainless steel
2
The System Kit (Part #12135-1 for 1 1/2” kit; #12135-2
for 2” kit) contains additional hold-down hardware, connec­tion parts and adapters needed to complete water connec­tions from the collectors to the system feed and return line. The pipe adapters that connect the system piping to the col­lectors are high temperature CPVC. The system check valve is 1 1/2”- 2” PVC. Installation and homeowner manu­als are also included. Use one (1) kit per system.
Part No Qty 1 1/2” Qty 2” Description
10003-1 1 10003-2 10008-1 1 10008-2 10011 4 4 Hold-down strap clamp assembly 30061-1 1 30061-2 30089-1 2 30089-2 50006 2 2 Hold-down strap bracket 60001-2 2 60002-2 60546-1 4 60546-2 60019-2 1 1 Check Valve (1 1/2” & 2”) 19001 1 1 Installation Manual 19186 1 1 Owner’s Manual
__ __
__ __
__ __
__
Vacuum Relief Valve
1 Vacuum Relief Valve
__
Outlet header hold-down bracket assembly
1 Outlet header hold-down bracket assembly
__
End cap
1 End cap
__
Pipe adapter
2 Pipe adapter
__
System connector hose (7” long)
2 System connector hose (7” long)
__
Hose clamp, stainless steel
4 Hose clamp, stainless steel
2
2A
The Optional Supplemental System Isolation Kit
(Part #12033-5) includes a 1 1/2” - 2” PVC union ball valve and a 1 1/2”-2” PVC check valve to permit manual isolation of the solar system from the pool or spa filtration system. Use one (1) kit per system.
3
Hold-Down Strap is required to secure collectors to
the counting surface. Use strap 10035-1 (54’) for ro ws of up to 6 collectors or strap 10035-2 (107’) for rows of up to 12 collectors.
5
The Row Spacer Kit (Part #12017-1 for 1 1/2” kit; #12017-2
for 2”kit) is used when a row of collectors must be interrupted by a space to allow for obstructions such as a chimney or roof vent. It contains the hardware needed to space around any width obstructions by connecting appropriate lengths of PVC pipe to the pipe adapters at the inlet and outlet headers of the two col­lectors on either side of the obstructions. Use when required.
Part No Qty 1 1/2” Qty 2” Description
10008-1 1 10008-2 10011 4 4 Hold-down strap clamp assembly 30089-1 4 30089-2 50006 2 2 Hold-down strap bracket 60001-1 2 60002-1 60546-1 4 60546-2
__
__
__ __
__
Outlet header hold-down bracket assembly
1 Outlet header hold-down bracket assembly
__
Pipe adapter
4 Pipe adapter
__
Collector connector hose (3 3/4” long)
2 Collector connector hose (3 3/4” long)
__
Hose clamp, stainless steel
4 Hose clamp, stainless steel
4
The Add-A-Row Kit (Part #12043-1 for 1 1/2” kit; #12043-
2 for 2” kit) is used when more than one row of collectors is to be installed. Use one (1) kit for each collector row after the first.
Part No Qty 1 1/2” Qty 2” Description
10003-1 1 10003-2 10008-1 1 10008-2 10011 4 4 Hold-down strap clamp assembly 30061-1 1 30061-2 30089-1 2 30089-2 50006 2 2 Hold-down strap bracket 60001-2 2 60002-2 60546-1 4 60546-2
__ __
__ __
__ __
__
Vacuum Relief Valve
1 Vacuum Relief Valve
__
Outlet header hold-down bracket assembly
1 Outlet header hold-down bracket assembly
__
End cap
1 End cap
__
Pipe adapter
2 Pipe adapter
__
System connector hose (7” long)
2 System connector hose (7” long)
__
Hose clamp, stainless steel
4 Hose clamp, stainless steel
6
Double Hole Outlet Header Bracket
(Part #50069) may be used on steep roof applications or in high wind areas where extra hold-down strength is required.
7
Aluminum Mounting Bracket & Header Clamp Assembly
The Aluminum Header Bracket (Part #30171-1 for 1 1/2”;
#30177-1 for 2”) is used as optional outlet header mounting hardware. It replaces or can be used in conjunction with the Outlet Header Hold-Down Bracket assembly (10008-1/-2). The bracket is designed for installations that require more flexibility for the outlet header mounting hardware location, such as bar­rel tile roofs or installations that require mounting hardware to be anchored into rafters or beams.
The Aluminum Header Clamp Assembly (Par t #10117-1 for 1 1/2”; #10117-2 for 2”)
is used the same as the Aluminum Header Bracket (30171-1) and allows for collector replacement without disturbing the roof penetrations.
3
8
Header Inserts (Part #50055-1 for
1 1/2”; #50055-2 for 2”) are used in special situations where unusually high stagnation temperatures are expected, such as in a desert climate or where abnormally high system pressures may occur. Use four (4) inserts per collector.
9
The Optional Supplemental Hurricane Collector
Hold-Down Kit (Part #12035-1 for 1 1/2”, #12035-2 for
2”) when used in addition to the basic collector installa­tion kit, meets collector mounting standards in Florida Counties requiring resistance to 120 mile per hour winds. In regions where high winds are prevalent, special mounting precautions may be necessary to secure brackets to the mounting surface. One method, using threaded rods, is shown here.
MOUNTING THE SOLAR COLLECTORS
Refer to Figure 1 throughout this section. When mounting the collectors, always make provisions for inlet connec­tions at the bottom header and outlet connections at the top. The outlet headers must be pitched a vertical dis­tance of at least 8” (20cm) above the inlet headers to assure proper drainage and uniform flow. Plan the col­lector location to allow at least one foot on all sides of the row of collectors for mounting brackets and piping. The outlet pipe for each row of collectors must be connected diagonally opposite the inlet pipe. Refer to Figure 2.
VACUUM RELIEF VALVE
Note: This end of row lower than opposite end. See instruction 2.
FLOW
Figure 2
INLET
(from pool)
FLOW
END CAP
OUTLET
(to pool)
OUTLET HEADER HOLD-DOWN BRACKET
CENTERLINE
OF CLAMP AND HOSE
3/8" (10mm)
HEADER
HOSE
LOCATING
SHOULDER
HEADER SEALING
GROVE
HOLD-DOWN CLAMP
OPTIONAL
HEADER
INSERT
ABSORBER
PLATE
DISTANCE BETWEEN PANEL
HEADERS AND STRAPS
Collector
Panel Size
in feet
_________
12 10
8 6 4
Collector
(A) Distance
inches (cm)
_________
60 (152) 48 (122)
36 (91) 24 (60)
_____
Collector
(B) Distance
inches (cm)
_________
16 (40)
HOSE
CLAMP
PIPE ADAPTOR
HIGH WIND AREA
BRACKET BOLTING
3/8" (10mm)
3 3/4" HOSE
BRACKET
LONG HOSE
VACUUM
RELIEF
VALVE
BRACKET
(130 cm)
SHORT
HOSE
51"
Figure 1
ASSEMBLY ON
ROOF DIAGRAM
4
(130 cm)
51"
(130 cm)
51"
SEE TABLE B
SHORT
HOSE
PANEL
(130 cm)
51"
SEE TABLE A
(from pool)
OUTLET HEADERS
(130 cm)
51"
OUTLET
INLET
(to return)
SHORT
HOSE
(130 cm)
51"
CENTERLINE
ALTERNATE VACUUM
RELIEF VALVE LOCATION
VACUUM RELIEF VALVE
ADAPTOR
HOSE
3/4 HEIGHT
FROM POOL
TO UPPER
HEADER
LONG HOSE
ADAPTOR
PANEL
INLET OUTLET
PIPE
PIPE
Loading...
+ 8 hidden pages