INSTALLATION MANUAL FOR
AQUATHERM INDUSTRIES
SOLAR COLLECTORS
FOR MODEL NUMBERS:
10001-5
10001-2
10001-1
MANUAL CONTENTS
This manual provides a detailed step-by-step procedure for the installation of an Aquatherm
Industries solar pool heating system. If the directions are followed correctly and only recommended
Aquatherm Industries hardware and components
are used, the installed system should provide years
of trouble free service, savings, and enjoyment.
10204-12
10204-10
10204-8
16104-12
16104-10
16104-8
CAUTION: SOLAR COLLECTORS ARE OFTEN INSTALLED
ON THE ROOFS OF BUILDINGS. UNLESS YOU ARE VERY
FAMILIAR WITH WORKING ON ROOFS AND HAVE THE
PROPER LADDERS AND SAFETY EQUIPMENT FOR
SUCH WORK, YOU SHOULD HIRE SOMEONE WITH THE
NECESSARY EXPERIENCE TO DO THE INSTALLATION.
FAILURE T O OBSERVE SAFE PRACTICES ON A ROOF OR
OTHER ELEVATED STR UCTURE MAY RESULT IN FALLING,
LEADING TO SERIOUS INJURY TO YOU.
16204-12
16204-10
16204-8
MOUNTING
COMPONENTS
DIAGRAM
MOUNTING COMPONENTS
This section provides descriptions and part numbers of the
Aquatherm Industries Installation Kits required for each
solar pool heating system. The mounting location of each
kit component is shown by the corresponding circled number in the ‘Mounting Components’diagram, shown above.
1
The Collector Installation Kit (Part #12034-1 for 1 1/2” kit;
#12034-2 for 2” kit) contains the parts needed to fasten a single
solar collector to a supporting surface and to make water connections from one collector to another. Hold-down strap is not included and must be ordered separately Use one (1) kit per collector.
Part No Qty 1 1/2” Qty 2” Description
10008-1 1
10008-2
50006 2 2 Hold-down strap bracket
60001-1 2
60002-1
60546-1 4
60546-2
__
__
__
__
Outlet header hold-down bracket assembly
1 Outlet header hold-down bracket assembly
__
Collector connector hose (3 3/4” long)
2 Collector connector hose (3 3/4” long)
__
Hose clamp, stainless steel
4 Hose clamp, stainless steel
2
The System Kit (Part #12135-1 for 1 1/2” kit; #12135-2
for 2” kit) contains additional hold-down hardware, connection parts and adapters needed to complete water connections from the collectors to the system feed and return line.
The pipe adapters that connect the system piping to the collectors are high temperature CPVC. The system check
valve is 1 1/2”- 2” PVC. Installation and homeowner manuals are also included. Use one (1) kit per system.
Part No Qty 1 1/2” Qty 2” Description
10003-1 1
10003-2
10008-1 1
10008-2
10011 4 4 Hold-down strap clamp assembly
30061-1 1
30061-2
30089-1 2
30089-2
50006 2 2 Hold-down strap bracket
60001-2 2
60002-2
60546-1 4
60546-2
60019-2 1 1 Check Valve (1 1/2” & 2”)
19001 1 1 Installation Manual
19186 1 1 Owner’s Manual
__
__
__
__
__
__
__
Vacuum Relief Valve
1 Vacuum Relief Valve
__
Outlet header hold-down bracket assembly
1 Outlet header hold-down bracket assembly
__
End cap
1 End cap
__
Pipe adapter
2 Pipe adapter
__
System connector hose (7” long)
2 System connector hose (7” long)
__
Hose clamp, stainless steel
4 Hose clamp, stainless steel
2
2A
The Optional Supplemental System Isolation Kit
(Part #12033-5) includes a 1 1/2” - 2” PVC union ball
valve and a 1 1/2”-2” PVC check valve to permit manual
isolation of the solar system from the pool or spa filtration
system. Use one (1) kit per system.
3
Hold-Down Strap is required to secure collectors to
the counting surface. Use strap 10035-1 (54’) for ro ws of
up to 6 collectors or strap 10035-2 (107’) for rows of up
to 12 collectors.
5
The Row Spacer Kit (Part #12017-1 for 1 1/2” kit; #12017-2
for 2”kit) is used when a row of collectors must be interrupted by
a space to allow for obstructions such as a chimney or roof vent.
It contains the hardware needed to space around any width
obstructions by connecting appropriate lengths of PVC pipe to
the pipe adapters at the inlet and outlet headers of the two collectors on either side of the obstructions. Use when required.
Part No Qty 1 1/2” Qty 2” Description
10008-1 1
10008-2
10011 4 4 Hold-down strap clamp assembly
30089-1 4
30089-2
50006 2 2 Hold-down strap bracket
60001-1 2
60002-1
60546-1 4
60546-2
__
__
__
__
__
Outlet header hold-down bracket assembly
1 Outlet header hold-down bracket assembly
__
Pipe adapter
4 Pipe adapter
__
Collector connector hose (3 3/4” long)
2 Collector connector hose (3 3/4” long)
__
Hose clamp, stainless steel
4 Hose clamp, stainless steel
4
The Add-A-Row Kit (Part #12043-1 for 1 1/2” kit; #12043-
2 for 2” kit) is used when more than one row of collectors is to
be installed. Use one (1) kit for each collector row after the first.
Part No Qty 1 1/2” Qty 2” Description
10003-1 1
10003-2
10008-1 1
10008-2
10011 4 4 Hold-down strap clamp assembly
30061-1 1
30061-2
30089-1 2
30089-2
50006 2 2 Hold-down strap bracket
60001-2 2
60002-2
60546-1 4
60546-2
__
__
__
__
__
__
__
Vacuum Relief Valve
1 Vacuum Relief Valve
__
Outlet header hold-down bracket assembly
1 Outlet header hold-down bracket assembly
__
End cap
1 End cap
__
Pipe adapter
2 Pipe adapter
__
System connector hose (7” long)
2 System connector hose (7” long)
__
Hose clamp, stainless steel
4 Hose clamp, stainless steel
6
Double Hole Outlet Header Bracket
(Part #50069) may be used on steep roof
applications or in high wind areas where
extra hold-down strength is required.
7
Aluminum Mounting Bracket & Header Clamp Assembly
The Aluminum Header Bracket (Part #30171-1 for 1 1/2”;
#30177-1 for 2”) is used as optional outlet header mounting
hardware. It replaces or can be used in conjunction with the
Outlet Header Hold-Down Bracket assembly (10008-1/-2). The
bracket is designed for installations that require more flexibility
for the outlet header mounting hardware location, such as barrel tile roofs or installations that require mounting hardware to
be anchored into rafters or beams.
The Aluminum Header Clamp Assembly (Par t #10117-1 for
1 1/2”; #10117-2 for 2”)
is used the same as the Aluminum
Header Bracket (30171-1) and allows for collector
replacement without disturbing the roof penetrations.
3
8
Header Inserts (Part #50055-1 for
1 1/2”; #50055-2 for 2”) are used
in special situations where
unusually high stagnation
temperatures are expected,
such as in a desert climate
or where abnormally high
system pressures may occur.
Use four (4) inserts per collector.
9
The Optional Supplemental Hurricane Collector
Hold-Down Kit (Part #12035-1 for 1 1/2”, #12035-2 for
2”) when used in addition to the basic collector installation kit, meets collector mounting standards in Florida
Counties requiring resistance to 120 mile per hour winds.
In regions where high winds are prevalent, special
mounting precautions may be necessary to secure
brackets to the mounting surface. One method, using
threaded rods, is shown here.
MOUNTING THE SOLAR COLLECTORS
Refer to Figure 1 throughout this section. When mounting
the collectors, always make provisions for inlet connections at the bottom header and outlet connections at the
top. The outlet headers must be pitched a vertical distance of at least 8” (20cm) above the inlet headers to
assure proper drainage and uniform flow. Plan the collector location to allow at least one foot on all sides of the
row of collectors for mounting brackets and piping. The
outlet pipe for each row of collectors must be connected
diagonally opposite the inlet pipe. Refer to Figure 2.
VACUUM RELIEF VALVE
Note: This end of row lower than
opposite end. See instruction 2.
FLOW
Figure 2
INLET
(from pool)
FLOW
END
CAP
OUTLET
(to pool)
OUTLET HEADER HOLD-DOWN BRACKET
CENTERLINE
OF CLAMP
AND HOSE
3/8" (10mm)
HEADER
HOSE
LOCATING
SHOULDER
HEADER
SEALING
GROVE
HOLD-DOWN CLAMP
OPTIONAL
HEADER
INSERT
ABSORBER
PLATE
DISTANCE BETWEEN PANEL
HEADERS AND STRAPS
Collector
Panel Size
in feet
_________
12
10
8
6
4
Collector
(A) Distance
inches (cm)
_________
60 (152)
48 (122)
36 (91)
24 (60)
_____
Collector
(B) Distance
inches (cm)
_________
16 (40)
HOSE
CLAMP
PIPE
ADAPTOR
HIGH WIND AREA
BRACKET BOLTING
3/8" (10mm)
3 3/4" HOSE
BRACKET
LONG
HOSE
VACUUM
RELIEF
VALVE
BRACKET
(130 cm)
SHORT
HOSE
51"
Figure 1
ASSEMBLY ON
ROOF DIAGRAM
4
(130 cm)
51"
(130 cm)
51"
SEE TABLE B
SHORT
HOSE
PANEL
(130 cm)
51"
SEE TABLE A
(from pool)
OUTLET HEADERS
(130 cm)
51"
OUTLET
INLET
(to return)
SHORT
HOSE
(130 cm)
51"
CENTERLINE
ALTERNATE VACUUM
RELIEF VALVE LOCATION
VACUUM
RELIEF
VALVE
ADAPTOR
HOSE
3/4 HEIGHT
FROM POOL
TO UPPER
HEADER
LONG HOSE
ADAPTOR
PANEL
INLET OUTLET
PIPE
PIPE