Aqua-Pure SST2HB User Manual [en, es, fr]

Installation and Operating Instructions For
AP1610SS, AP2610SS, SST1H1, SST1HA, SST2HA, SST2HB Stainless Steel Water Filters
Installer: Please leave manual with homeowner. Homeowner: Please retain for operation and
future maintenance instructions.
INSTR2071 1007
CAUTION
WARNING
CAUTION
Read, understand, and follow all safety information contained in these instructions prior to installation and use of the AP1610SS, AP2610SS, SST1H1, SST1HA, SST2HA & SST2HB Stain­less Steel Water Filters. Retain these instructions for future reference.
Intended use:
The AP1610SS, AP2610SS, SST1H1, SST1HA, SST2HA & SST2HB Stainless Steel Water Filters are intended for use in fi ltering potable water in homes and have not been evaluated for other uses. These systems must be installed as specifi ed in the installation instructions.
EXPLANATION OF SIGNAL WORD CONSEQUENCES
C
To reduce the risk associated with choking:
Do not allow children under 3 years of age to have access to small parts during the installation of this product. To reduce the risk associated with ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system.
To reduce the risk associated with a hazardous voltage due to an installer drilling through existing electric wiring or water pipes in the area of installation:
Do not install near electric wiring or piping which may be in the path of a drilling tool when selecting the position
to mount the fi lter bracket.
To reduce the risk of physical injury:
• Shut off inlet water supply and depressurize system as shown in manual prior to cartridge removal.
To reduce the risk of fi re or explosion:
• Use fi lter for liquid service only. Not for continuous gas service.
Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.
WARNING
CAUTION
To reduce the risk associated with property damage due to water leakage:
Read and follow Use Instructions before installation and use of this system.
• Installation and Use MUST comply with all state and local plumbing codes.
Protect from freezing, remove fi lter cartridge when temperatures are expected to drop below 40°F (4.4°C).
Do not install if water pressure exceeds 300 psi (2,070 kPa). If your water pressure exceeds 80 psi (552 kPa),
you must install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.
Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a
water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.
Do not use a torch or other high temperature sources near fi lter system, cartridges, plastic fi ttings or plastic
plumbing.
• On plastic fi ttings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may
deteriorate plastic.
• Take care when using pliers or pipe wrenches to tighten plastic fi ttings, as damage may occur if overtightening occurs.
Do not install in direct sunlight or outdoors without protection from precipitation.
• Mount fi lter in such a position as to prevent it from being struck by other items used in the area of installation.
• Ensure that the location and fasteners will support the weight of the system.
• Ensure all tubing and fi ttings are secure and free of leaks.
• The disposable fi lter cartridge MUST be replaced ever 6 months, at the rated capacity or if a noticeable reduc­tion in fl ow rate occurs.
IMPORTANT NOTES
• Failure to follow instructions may void warranty.
• Allow a minimum of 2” (5.1 cm) clear space under fi lter to facilitate cartridge change.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
GETTING STARTED
Your new Aqua-Pure® Stainless Steel Water Filter can be installed on your hot or cold water line, depending on the filter cartridge used. Filter can be adapted to various pipe sizes by using reducing adapters on either end. Installation fit-
tings can be either sweated or threaded. Use galvanized fittings for installation on galvanized pipe.
CAUTION
To reduce the risk associated with property damage due to water leakage:
• Installation and Use MUST comply with all state and local plumbing codes.
Protect from freezing, remove fi lter cartridge when temperatures are expected to drop below 40°F (4.4°C).
• Mount fi lter in such a position as to prevent it from being struck by other items used in the area of installation.
City Water
Meter
Aqua-Pure Sediment/ Rust Filter
Well Water Bypass Section can be installed around unit if desired using
Pressure
Tank
Aqua-Pure Sediment/ Rust Filter
Aqua-Pure Taste/
Odor Undersink
Filter
Aqua-Pure Taste/
Odor Undersink
Filter
Hot Water
Aqua-Pure
AP400SS Scale
Filter
either sweated or threaded valves.
Hot Water
Heater
Aqua-Pure Sediment/ Rust Filter
WARNING
To reduce the risk associated with a hazardous voltage due to an installer drilling through existing electric wiring or water pipes in the area of installation:
Do not install near electric wiring or piping which may be in the path of a drilling tool when selecting the position to
mount the fi lter bracket.
IMPORTANT INSTALLATION INSTRUCTIONS
FOR INSTALLING AQUA-PURE SEDIMENT/RUST FILTER ON HOT OR COLD WATER LINE (DEPENDING ON FILTER USED)
Tools and Parts Required (not included):
1) 3/4” CXM Cast Union
2) 3/4” x M ST Adapter Wrought
3) PTFE Tape
4) Tube Cutter
5) 3/4” SW Gate Valve
Identify all parts as shown in diagram. Read all instructions carefully before attempting to start installation.
1
4
3
5
2
Step 1: Snug fit all component parts and calculate length of tub­ing to be removed.
Step 4: Sweat SW gate valve onto line backwards so drain can later be used to release pressure when changing filter.
Step 2: Cut tubing. Step 3: Install sweat side of CXM
cast union onto tube.
Step 5: Cover threads of M ST adapter with PTFE Tape and screw firmly into filter head making a tight connection.
Step 6: Sweat M ST adapter with filter head attached to valve making sure that filter head is vertical. (It may be necessary to temporarily support weight of filter until filter bracket is installed. See Step 9.)
Step 7: Screw CM part of union into filter. It may be necessary to slightly spring tubing temporarily out of align­ment in order for tubing to enter union.
Step 8: Connect two halves of union and tightn, making sure filter is in straight vertical position.
Step 9: Mount filter bracket to wall or suitable support.
IMPORTANT INSTALLATION INSTRUCTIONS (CONT.)
FOR INSTALLING AQUA-PURE TASTE/ODOR FILTER UNDER KITCHEN SINK ON COLD WATER LINE
Tools and Parts Required (not included):
1) 3/4” x M ST Adapter Wrought
2) SW Elbow
3) PTFE Tape
4) Tube Cutter
5) 3/4” SW Gate Valve
6) 3 Ft. (0.9 M) Piece of 3/4” Copper Tubing
Identify all parts as shown in diagram. Read all instructions carefully before attempting to start installation.
1
4
3
5
2
6
Step 1: Cut out approximately 8” (20 cm) section of pip starting 12” (30.5 cm) for 1 high units and 22” (56 cm) for 2 high units off the floor.
Step 4: Cover threads of both adapters with PTFE tape and screw one adapter into “IN” side of filter.
Step 2: Sweat SW gate valve onto water line. Sweat SW elbow onto piece of copper tubing and sweat tub­ing to valve.
Step 5: Mount filter bracket to wall or suitable support.
Step 3: Sweat SW elbow to one adapter using piece of copper tubing.
Step 6: Screw remaining adapter into “OUT” side of filter, then sweat a piece of tubing to the adapter.
Step 7: Sweat elbow to tube connected to “right” adapter.
Step 8: Loose fit “A” elbow to water line coming down from sink. Measure “B” and cut tubing to go across filter. Loose fit “C” elbow at end of tubing. Measure “D” and cut tubing to fit to elbow sweat­ed to”right” adapter on filter.
Step 9: Now proceed to sweat remain­ing fitting.