SAFETY INFORMATION
CAUTION
WARNING
CAUTION
Read, understand, and follow all safety information contained in these instructions prior to installation and use of the APIL3 Filtration System. Retain these instructions for future refer­ence.
Intended use:
The APIL3 Filtration System is intended for use in fi ltering potable water for refrigerators and ice makers and has not been evaluated for other uses. These systems must be installed as shown in the installation diagrams.
C
To reduce the risk associated with choking:
Do not allow children under 3 years of age to have access to small parts during the installation of this product.
To reduce the risk associated with ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
To reduce the risk associated with a hazardous voltage due to an installer drilling through existing electric wiring or water pipes in the area of installation:
Do not install near electric wiring or piping which may be in the path of a drilling tool when selecting the position to mount the fi lter bracket.
Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.
WARNING
CAUTION
To reduce the risk associated with property damage due to water leakage:
Read and follow Use Instructions before installation and use of this system.
• Installation and Use MUST comply with all state and local plumbing codes.
Protect from freezing, remove fi lter cartridge when temperatures are expected to drop below 40°F (4.4°C).
Do not install on hot water supply lines. The maximum operating water temperature of this fi lter system is 100˚F (37.8˚C).
Do not install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds 80 psi (552 kPa), you must
install a pressure limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.
• Where a backfl ow prevention device is installed on a water system, a device for controlling pressure due to thermal
expansion must be installed.
Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water
hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.
Do not use a torch or other high temperature sources near fi lter system, cartridges, plastic fi ttings or plastic plumbing.
• On plastic fi ttings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate
plastic.
Do not install in direct sunlight or outdoors.
Do not install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.
• Mount fi lter in such a position as to prevent it from being struck by other items used in the area of installation.
• Ensure that the location and fasteners will support the weight of the system.
• Ensure all tubing and fi ttings are secure and free of leaks.
• The disposable fi lter cartridge MUST be replaced every 6 months, at the rated capacity or sooner if a noticeable
reduction in fl ow rate occurs.
IMPORTANT NOTES
• Failure to follow instructions will void warranty.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
Model Flow Rate Rated Capacity Pressure Temperature
APIL3R
0.5 gpm (1.9 lpm)
6 months
20-125 psi
(138-862 kPa)
40-100°F
(4.4-37.8°C)
Installation Instructions
Parts Required
1) APIL3R Replacement Filter
2) Two Quick Connect Fittings
3) PTFE Thread Tape (Not included)
②③
Installing the APIL3R Replacement Water Filter
IMPORTANT NOTE
• Have a bucket and towel ready.
1) Disconnect the old filter at the INLET side first (this shuts off the water) by squeezing the valved fitting and pulling away from the filter. Do the same for the outlet side.
2) Attach O-Ring fittings to new filter. Be sure to coat threads with PTFE thread tape.
3) With the OUTLET end over a bucket, attach INLET O-ring fitting (water will begin to flow through filter). Flush two (2) gallons of water through the filter before use (approximately 2.5 minutes). Disconnect INLET fitting to stop water flow.
4). Connect OUTLET fitting.
5) Connect INLET Fitting. Filter is now ready for use.
6) Write the date on the filter when installed, then mark your calendar with a reminder to replace the filter in 6 (six) months.
Limited Warranty: 3M Purification Inc. warrants this Product will be free from defects in material and manufacture for a period of one (1) year from the date of purchase. This warranty does not cover failures resulting from abuse, misuse, alteration or damage not caused by 3M Purification Inc. or failure to follow installation and use instructions. No warranty is given as to the service life of any filter cartridge or membrane as it will vary with local water conditions and water consumption. 3M PURIFICATION INC. MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS
OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOMER OR USAGE OF TRADE. If the Product fails to satisfy this Limited Warranty during the warranty period, 3M Purification Inc. will replace the Product or refund your Product purchase price. This warranty does not cover labor. The remedy stated in this paragraph is Customer’s sole remedy and 3M’s exclusive obligation.
This warranty gives you specific legal rights, and you may have other rights which may vary from state to state, or country to country. For any warranty questions, please call 1-877-238-9119 or mail your request to: Warranty Claims, 3M Purification Inc., 400 Research Parkway, Meriden, CT 06450. Proof of purchase (original sales receipt) must accompany the warranty claim, along with a complete description of the Product, model number and alleged defect.
Limitation of Liability. 3M Purification Inc. will not be liable for any loss or damage arising from this 3M Purification Inc. product, whether direct, indirect, special, incidental, or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. Some states and countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
Loading...
+ 5 hidden pages