Aquametrix Model 2200C
by
Description
Model 2200C conductivity analyzer/controller
is a dependable industrial grade instrument designed for controlling rising and falling conductivity in the most demanding environments.
Extremely easy to operate with a large bright
LED display and intuitive user interface, this
microprocessor-based analyzer/controller is
packaged in a NEMA 4X berglass reinforced
polyester enclosure and used in a wide variety
of industrial and municipal applications.
Frequently used functions are accessed through
an intuitive step-through menu printed directly
on the front panel for ease of navigation. Pressing the MENU key scrolls through the menu, illuminating a small LED beside the selected item
and displaying the stored value. Arrow keys are
used to change the value. Seldom used adjustments such as password activation are set using DIP switches on the back of the swing-out
front panel.
INPUTS
The 2200C accepts AquaMetrix MS (epoxy
body) or AM (stainless steel body) conductivity
sensors. These have graphite or stainless steel
electrodes and can be ordered for use in standard or high temperature/pressure applications.
To optimize resolution the 2200C can be ordered pre-congured for any of seventeen
standard conductivity ranges, plus two special
ranges.
CALIBRATION
Calibration is fast and easy. Press the MENU
key until the CALIBR ATION LED illuminates.
Place the probe in a buffer solution. Use the arrow keys to set the value. Press ENTER twice.
Repeat the process for the second bufer solu-
tion. The 2200C is now calibrated.
Metrix
Water Analytics
Conductivity Analyzer / Controller
OUTPUTS
Model 2200C provides three analog outputs,
4-20 mA, 0-5 Vdc and 0-1 mA.
The instrument also provides control of an external device using the control relay. The control
relay can be selected to activate in response to
either rising or falling conductivity. Setpoints for
Relay On and Relay Off are independently set.
The control relay has a builtin cycle timer, with
easy-to-adjust Relay On and Relay Off cycle
times. This feature enables tighter control of
batch processes.
The Control Relay has a manual override, which
overrides the controller, placing the relay in
AUTO, OFF, or ON mode. This is a useful feature when servicing auxiliary devices connected
to the relay.
An alarm relay has both high and low setpoints
with a xed deadband. When this relay is energized, the Alarm LED on the front panel also illuminates to clearly indicate an alarm condition.
DIAGNOSTICS
A self-diagnostics program clearly indicates any
system errors or faults. When the unit is online,
the RUN LED on the front panel will illuminate.
In the event of a system error the FAIL LED will
illuminate. When the FAIL LED is illuminated,
the Status menu item will display a fault code.
The Manual will indicate the source and likely
remedy for the fault. When the fault is corrected
the FAIL LED will no longer be illuminated.
ENCLOSURE
Model 2200C is packaged in a rugged NEMA
4X berglass reinforced polyester enclosure. It
is ideally suited for heavy-duty outdoor applications such as municipal and industrial wastewater applications.
Features
• Simple step-through menu
design for quick and easy setup
• On/Off cycle timer feature
• High/low alarm relay
• ALARM LED on front panel
• Output signal eld-scalable
for maximum resolution
• Status errors illuminate
FAIL LED on front panel
• Test feature allows sweep-
through range to test setpoints and alarms or to
simulate value for setup
• Auto tempera-
ture compensation
• Password protection
• High temperature/pres-
sure and low temperature/
pressure cells available
Applications
• Process Control and Cooling
Tower Control
• Water Quality Monitoring
• Industrial and Municipal Water
Treatment, including Reverse Osmosis, De-ionization, Desalination, and High Purity Water Processing
• Plating, Computer Chip Fabrication, Circuit Board Manufacturing, Food and Beverage, Chemical Processing, Mining, Nuclear
Energy and Pharmaceutical Industries
by
100 School Street
Andover, MA 01810
Toll free - 855-747-7623
www.WaterAnalytics.net
Metrix
Water Analytics
978-749-9949
Model 2200C Conductivity Analyzer / Controller
Technical Data
Display 4 x 7 segment 1/2” LED Display
Indicator Lights 4 LED indicators: Status, Alarm, Relay
Measuring Range
Range The range is factory set but may be eld
Temperature 0 to 100°C (32 to 212°F)
Power Requirements
Standard 98-132 VAC 50/60 Hz, (less than 10 VA)
Optional 196-26 4 VAC 50/60 Hz (less than 10 VA)
Ambient Conditions
Temperature -30 to 50°C (-22 to 122°F)
Humidity 0 to 90% RH non-condensing
Control Relays
Number Two Control Relays: Relay A, Relay B
Rating 5 A 115/230 VAC, 5A 30 VDC, SPDT
On/ Off Setpoints Field selectable full scale
Cycle Timer Field selectable 0 - 600 seconds
Manual Override AUTO/OFF/ON
Fail-safe Normal or fail safe operation
Alarm Relay
Number One High and Low Alarm Relay
Rating 5 A, 115/230 VAC, 5A 30 VDC, SPDT
Alarm High Field selectable full scale
Alarm Low Field selectable full scale
Deadband Fixed at 2% of full scale
Fail Safe Normal or fail safe operation
Relay Indicators Two individual LEDs indicate status
Analog Outputs
Non-isolated 0-1 mA, 100 ohms maximum load
Non-Isolated 0-5 VDC, 1000 ohms minimum load
Isolated 4-20 mA, 800 ohms maximum load
Range Expand Analog outputs can be scaled to rep-
Output Hold Analog outputs are placed on hold
Temperature The 0-1 mA and 0-5 VDC outputs
Automatic 0-100°C (32 to 212°F)
Calibration 1 point, manual
Temperature Compensation
Automatic
A, Relay B
changed
23-26 VDC (nominal current: 150 mA)
of two control relays and alarm relay
Output is isolated from the input, the
ground, line power and all other outputs.
resent any segment of the instrument
scale, minimum of 10% of full scale.
when the instrument is in menu mode.
can be selected to track either the pH
or the temperature of the process.
0-100°C (32 to 212°F) if probe has temperature sensor.
Diagnostics
Invalid Entries Identied by ashing LEDs
Fail LED Illuminates red to indicate Status Fault. Scroll
Auto LED Illuminates red when Alarm Relay is energized,
Test Display value and analog outputs can be set to
Safety & Security
Operator Password protected (activated by DIP switch)
Memory Nonvolatile memory (EPROM)
Microprocessor Watchdog timer monitors microprocessor. In-
Sensitivity 0.1% of span
Stability 0.1% of span per 24 hours non-cumulative
Temperature Drif t Zero - 0.01% of span per °C
Enclosure NEMA 4X molded berglass reinforced polyes-
Mounting
Standard Surface Mount
Optional Panel Mount kit P/N C35- 68
Weight 3.5 lbs. (1.6 kg)
to Status in Menu to determine fault code. Refer to Manual for probable cause and remedy
indicating high/low process value or memory
loss.
any value for testing and diagnostic purposes
strument automatically returns to online operation if left in menu mode for more than 10 minutes and no key is pressed.
Span - 0.01% of span per °C
ter enclosure with four 1/2” conduit holes and
mounting feet for surface mount. A NEMA 4X
plug is provided for one hole.
Pipe Mount kit P/N C35-69
Related Products - Probes & Accessories
MS Cells Epoxy, low/high pressure, compression tting 3/4” NPT.
MHMSC Tank Mount Hardware for MS Cells.
MS-HTC CPVC Wet/Hot Tap Mount for MS Cells.
Conductivity Range
(µSiemens/cm)
0-2 0.01 0-10 10
0-5 0.01 0-20 10
0-10 0.05 0-50 10
0-20 0.05 0-100 20
0-50 0.05 0-500 50
0-100 0.05 0-1000 50
0-200 0.5
0-500 0.5 Special Ranges
0-1000 0.5 0-15% H2SO
0-2000 1 0-15% NAOH 50 tt
0-5000 1
Cell
Constant
Conductivity Range
(mSiemens/cm)
4
Cell
Constant
50
Ordering Information
2200C Conductivity Analyzer/Controller
2200C
1 120 Vac, 50/60 Hz Power
2 240 Vac, 50/60 Hz Power
A Sur face Mount
B Panel Mount
C Pipe Mount
www.WaterAnalytics.net 978-749-9949 Toll free - 855-747-7623 (855-pHProbe)