Aqua Bath CP3636BF User Manual

Page 1
Acrylic Pan - Transfer Shower - ADA Compliant
p
Model CP3636BF
Acrylic pans designed for new build and renova t ions of existing hospitals, nursing homes, rehabilitation centers, hotels, motels, dormitories and residential applications.
Meets ANSI A117.1, ADA Guidelines and other standards
for accessibility
Acrylic one-piece molded construction simplifies installation with a lightweight durable base.
Inside dimensions: 36" W x 36" D x 4" H.
3/4" threshold height for top of slab installation.
Patented integral molded in "Trench Drain System" to help channel water from the front of the unit to the center drain location.
For additional information, call the
Aqua Bath Customer Service
Department At 1-800-232-2284
Please check with your local city and state for code compliancy. Aqua Bath's advertised ADA compliant units are based on our interpretation of the Americans with Disabilities Act 1991 Guidelines. Field alterations or improper installation could take the units out of compliance. Aqua Bath accepts no
onsibility for final code compliance.
res
TRANSFER SHOWER PAN
Aqua Bath Transfer Shower Pan CP3636BF is molded from a single sheet of cast acrylic so as not to have any joints or seams. Shall meet ANSI Z124.2. Shall meet ADA guidelines and other standards for accessibility. Unit shall have a backside flame spread of less than 30 (Class B). Shall be designed to be ADA COMPLIANT and NAHB LISTED. The enclosure shall have inside dimensions of 36" W x 36" D x 4" H and outside dimensions of 38½" W x 37¼" D x 6" H. The unit shall be molded with a patented integral recessed "Trench Drain System" so as to direct water to the center drain location. The approximate weight of the unit shall be 55lbs.
To be ADA compliant, top of threshold cannot exceed 1/2" above finished floor material.
The transfer shower pan shall be equipped with the following factory installed accessories: 1) Self-caulking brass drain with stainless steel strainer (not installed). 2) Ribbed bottom for slip resistance (standard).
AVAILABLE OPTIONS
1) Available in model CP3636TD - This unit is the same as the above stated unit except it will have a center front
trench drain located approximately 4" inside of the front flange.
2) ASTM F462 non-slip bottom (see drawing CP3636BF-VB).
(*) When the ASTM F462 bottom is specified with the center drain location, it will re-configure the trench drain system. A signed off approval is required for the bottom re-configuration.
Modifications: Received and / or approved by:
CP3636BF Acrylic Pan - Transfer Shower Unit - ADA Compliant
05/04
AQUA BATH COMPANY INC.921 Cherokee Ave.Nashville, TN 372071-800-232-2284Fax (615) 227-9446
www.aquabath.com
Page 2
Page 3
Page 4
CP3636BF Acrylic Transfer Shower Pan Installation Guidelines
T
Installation Requirements
Check to make sure that rough in dimensions of framing studs matches the outside dimensions (OD) of the
acrylic pan (37 1/4" x 38 1/2", reference "top view" in illustration box below) See Figures #1 and #2 on Page 2
Pre-Drill holes in acrylic pan top flanges (matching location of stud supports) for connection of acrylic pan to
stud supports. The diameter of holes drilled should be the proper size for diameter of fasteners to be used (reference "detail at top flange" in illustration box below) See Figure #3 on Page 2
Check to make sure that area where pan is to be installed is level, free of debris, and that the area where the drain
is placed has been chipped out (1/2" deep x 10" diameter). See Figure #4 on Page 2
Steps For The Installation Process
Dry fit acrylic pan into its installation position to ensure proper dimensional fit, that chipped out area at drain
location is in correct location and that acrylic pan sits level. See Figure #5 on Page 2
After dry fit is complete, you may grout acrylic pan into place. Be sure to use a Non-Shrink Grout and mix it
extra wet. After grout is place, make sure pan is level left to right and front to back along top flanges (do not level at floor of unit as it is angled to direct water to the drain). All acrylic pans have a 2-degree angle built into them
to help direct water to the drain (reference "side view" in illustration box below). See Figure #6 on Page 2
Place a 100lb weight at drain location and additional weights on floor of acrylic pan to help pan adhere to grout.
Attach acrylic pan to stud supports through pre-drilled holes with fasteners.
Apply a bead of construction adhesive (1/8") at front flange of acrylic pan to attach front of unit to floor.
36" I.D.
18"
¼"
4"
Ribbed Bottom For Slip Resistance
38½" O.D.
Pre-drilled hole for
connection of acrylic
pan to stud supports.
37¼" O.D.
37"
18"
36" I.D.
OP VIEW
1"
FRONT VIEW RIGHT SIDE VIEW
R=½"
Integral Trench Drain System
6"
¾"
2" Top Flange
Stud Support
Detail At Top Flange
CP3636BF Acrylic Transfer Shower Pan Installation Guidelines
02/04
AQUA BATH COMPANY INC.921 Cherokee Ave.Nashville, TN 372071-800-232-2284Fax (615) 227-9446
Page 1
Page 5
CP3636BF Acrylic Transfer Shower Pan Installation Guidelines
Figure #1 Figure #2
Figure #3 Figure #4
Figure #5 Figure #6
CP3636BF Acrylic Transfer Shower Pan Installation Guidelines
AQUA BATH COMPANY INC.921 Cherokee Ave.Nashville, TN 372071-800-232-2284Fax (615) 227-9446
Page 2
02/04
Page 6
1. Product Name
QUIKRETEª Non-Shrink Precision Grout #1585-00
2. Manufacturer
The QUIKRETE Companies One Securities Centre 3490 Piedmont Rd., NE, Suite 1300 Atlanta, GA 30305
(404) 634-9100 Fax: (404) 842-1424 www.quikrete.com
3. Product Description
BASIC USE Typical applications for QUIKRETE Non-Shrink
Precision Grout include grouting of:
• All types of machinery
• Steel columns
• Bearing plates
• Precast concrete
• Other anchoring conditions that require
high in-service strength
The nonshrink characteristics of Non-Shrink Precision Grout make it stable and capable of handling high load transfers.
COMPOSITION & MATERIALS QUIKRETE Non-Shrink Precision Grout is a non-
metallic Portland cement based material. Non-Shrink Precision Grout is a preblended product including expansi
ve additives, requiring only the addition of water to obtain flowable properties and high strengths.
SIZES
• 50 lb (22.7 kg) bags
COLORS
• Gray
YIELD A 50 lb (22.7 kg) bag of QUIKRETE Non-Shrink
Precision Grout will yield 0.45 cu ft (12.7 L) at flowable consistency.
LIMITATIONS The proper cleaning and wetting of surfaces to
be grouted is vital to maximum performance. Hot and cold temperature precautions, as they apply to concrete, should also be followed.
4. Technical Data
APPLICABLE STANDARDS ASTM International
• ASTM C109/C109M Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube Specimens)
• ASTM C939 Standard Test Method for Flow of Grout for Preplaced-Aggregate Concrete (Flow Cone Method)
• ASTM C1090 Standard Test Method for Measuring Changes in Height of Cylindrical Specimens from Hydraulic-Cement Grout
• ASTM C1107 Standard Specification for Packaged Dry, Hydraulic-Cement Grout (Nonshrink)
• ASTM E488 Standard Test Methods for Strength of Anchors in Concrete and Masonry Elements
U.S. Army Corps of Engineers (USACE) - CRD 621
PHYSICAL/CHEMICAL PROPERTIES QUIKRETE Non-Shrink Precision Grout complies
with all properties of ASTM C1107 and CRD 621 producing the results shown in Table 1.
5. Installation
MIXING QUIKRETE Non-Shrink Precision Grout should be
mechanically mixed for a minimum of 5 minutes.
PRECAUTIONS A
dd the minimum
amount of wa
ter necessary to produce the desired flow characteristics as indicated in Table 2. Do not exceed a flow of 20 seconds per ASTM C939.
METHODS Surfaces to receive the grout must be clean
and free of any type of foreign matter, grease, paint, oil, dust or efflorescence. In some cases it may be necessary to roughen smooth surfaces or etch old ones with acid. The area should be flushed and soaked with clean water prior to grouting leaving no standing water. Place the
GROUTS 03600
The QUIKRETE Companies
SPEC-DATAªand MANU-SPECªare registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style
of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2005 Reed Construction Data. All Rights Reserved.
TM
TABLE 1 TYPICAL PHYSICAL PROPERTIES AT 73°F (23°C)
Compressive strength, ASTM C109 modified per ASTM C1107
Plastic consistency
1 day 3000 psi (20.7 MPa)
3 days 9500 psi (65.5 MPa)
7 days 10,000 psi (68.9 MPa)
28 days 14,000 psi (96.5 MPa)
Height change, ASTM C1090 1, 3, 7 and 28 days 0 - 0.2%
Flowable consistency
1 day 3000 psi (20.7 MPa)
3 days 9000 psi (62.1 MPa)
7 days 9500 psi (65.5 MPa)
28 days 12,500 psi (86.2 MPa)
Height change, ASTM C1090 1, 3, 7 and 28 days 0 - 0.2%
Fluid consistency
1 day 2500 psi (17.2 MPa)
3 days 5000 psi (34.5 MPa)
7 days 6000 psi (41.4 MPa)
28 days 8000 psi (55.2 MPa)
Height change, ASTM C1090 1, 3, 7 and 28 days 0 - 0.2%
Pull-out strength, 35,000 psi (241 MPa)
ASTM E488
1
1
1 1/4" (31 mm) bolts embedded 9" (225 mm) deep in 3" (75 mm)
hole in 2000 psi (13.8 MPa) concrete.
TABLE 2 APPROXIMATE WATER REQUIRED FOR 50 LB (22.7 KG) OF GROUT
Plastic 1 gal (3.8 L) Flowable 1 gal + 1 pt (4.3 L) Fluid 1 gal + 3 pt (5.2 L)
TABLE 3 WORKING TIME
Temperature Working time
50°F (10°C) 25 min 73°F (23°C) 25 min 90°F (32°C) 15 min
QUIKRETEª Non-Shrink Precision Grout #1585-00
®
Page 7
SPEC-DATAªand MANU-SPECªare registered trademarks of Reed Elsevier Inc. The ten part SPEC-DATA format conforms to the editorial style
of The Construction Specifications Institute and is used with their permission. The manufacturer is responsible for technical accuracy. ©2005 Reed Construction Data. All Rights Reserved.
TM
grout quickly and continuously using light rod­ding to eliminate air bubbles.
WORKING TIME When properly mixed to a fluid consistency
QUIKRETE Non-Shrink Precision Grout will com­ply with all portions of ASTM C1107 and CRD 621 and retain a fluid consistency for the max­imum usable working times stated in Table 3.
TEMPERATURE Grout temperature should be maintained from
50 - 90 degrees F (10 - 32 degrees C) to achieve specified results. Use cold water in hot weather or hot water in cold weather to achieve desired grout temperature. Do not pour grout if tem­perature is expected to go below 32 degrees F (0 degrees C) within a 12 hour period.
CURING A damp cure of at least 3 days is necessary to
control the nonshrink characteristics and maintain strength levels.
6. Availability
QUIKRETE Non-Shrink Precision Grout is avail­able at leading concrete construction supply houses and distributors. Contact QUIKRETE Construction Products for the name of the nearest dealer.
7. Warranty
The QUIKRETE Companies warrant this product to be of merchantable quality when used or applied in accordance with the instructions herein. The product is not warranted as suit­able for any purpose or use other than the general purpose for which it is intended. Liability under this warranty is limited to the replacement of its product (as purchased) found to be defective, or at the shipping companies’ option, to refund the purchase price. In the event of a claim under this war­ranty, notice must be given to The QUIKRETE Companies in writing. This limited warranty is issued and accepted in lieu of all other express warranties and expressly excludes liability for consequential damages.
8. Maintenance
None required.
9. Technical Services
The QUIKRETE Companies maintain technical field representatives throughout the country. Contact a local distributor for the name and number of the nearest representative, or call QUIKRETE Construction Products.
10. Filing Systems
• First Source«
• Additional product information is available from the manufacturer.
GROUTS 03600
The QUIKRETE Companies
6943-09
®