UNIT MUST BE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES
R
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
cause property damage, injury or death. Read the Installation, Operating and
Maintenance Instructions thoroughly before installing or servicing this equipment.
Initial heating of unit may generate smoke or fumes and must be done in a well ventilated area.
Overexposure to smoke or fumes may cause nausea or dizziness.
This equipment has been engineered to provide you with year-round dependable service when used
according to the instructions in this manual and standard commercial kitchen practices.
FD Replacement Parts
FDL Replacement Parts
FDD or FDDL Replacement Parts
Warranty
11
11
14
17
20
1. OWNERS INFORMATION
General Information:
1. Always clean equipment thoroughly before first use. (See general cleaning instructions).
2. Check rating label for your model designation and electrical rating.
3. For best results, use stainless steel countertops.
4. All dimensions in parenthesis in centimeters unless noted.
5. APW Wyott Overhead Foodwarmers are constructed from high quality stainless steel and available
in lengths from 18" to 96”. Utilizing a metal sheath-heating element with a specially designed reflector,
these units give uniform heat over the entire holding surface.
6. In Europe, contact anAPW Wyott authorized serviceagency for replacement light bulbs.
Installation Instructions:
A. Always cleanequipment thoroughly before first use (See cleaning instructions).
B. Provide the following clearances around foodwarmer:
2
Page 3
Do not installA = Minimum clearance (in inches) to
C. Consult foodwarmer rating labelfor model designation and correct operating voltage and amperage.
D. Ceiling mounting brackets are provided with each foodwarmer for chain or shelf mounting. Remove
brackets form packaging and screws from ends of foodwarmer to attach brackets. Use four #10 screws
or studs with locknuts for shelf mounting. For chain mounting, use #14 jack chain and “S” hooks.
E. Remote switches are recommended. Longer switch life will result from cooler switch mounting
locations. Optional stainless steel remote toggle and infinite switch box kits are available. Installation
of remote switch box by service personnel requires 7/8" conduit, 1/4" push-on terminals, and no. 14
AWG copper wire suitable for at lest 90ºC. Mount remote box to flat surface with two #10 screws or
studs with locknuts. All wires marked as shown on wiring diagram.
F.Optional tubular stands are available for permanently mounting foodwarmers to non-combustible
countertops.
G. Optional portable legs are available for foodwarmers for use over non-combustible countertops.
H. Installation of cord sets by service personnel should utilize the strain relief, grounding stud, and
porcelain wire nuts provided with foodwarmers.
I.If unit is supplied with a power cord, the appliance must be positioned so that the plug is accessible.
NOTE: TO AVOID BURNING OR CHARRING OF MATERIALS IN THE SURFACE
BELOW THE FOODWARMER USE ONLY ABOVE AN ALL-METAL STRUCTURE
SUCHASATABLE OR COUNTERTOP. SEE MINIMUM CLEARANCE CHARTABOVE.
!!
REMOTE SWITCHES ARE RECOMMENDED FOR UNDER SHELF MOUNTING.
LONGER SWITCH LIFE WILL RESULT FROM COOLER SWITCH MOUNTING
LOCATIONS.
3
Page 4
General Operation Instructions:
1. All foodserviceequipment should be operated by trained personnel.
2. Do notallow your customers to come in contact with any surfacelabeled “CAUTION HOT”.
3. Never holdfood below 150°F (66°C).
Warranty Information:
Reliability Backed By APW Wyott’s Warranty:
All APW Wyott Overhead Warmers are backed by a one year parts and labor warranty, including On-Site
Service calls within 50 miles of authorized service technicians.
Service Information:
Service Hotline (800) 733-2203
2. SAFETY INFORMATION
APW Wyott Overhead Warmers are designed, built and sold for commercial use and should be operated by
trained personnel only. Clearly post all CAUTIONS, WARNINGS and OPERATING INSTRUCTIONS near
each unit to insure proper operation and to reduce the chance of personal injury and/or equipment damage.
Always disconnect power before servicing the Overhead Warmer. Surfaces will remain hot after power has
been turned off. Allow unit to cool before cleaning or servicing. Never clean the Overhead Warmer by
immersing it in water. The Overhead Warmer is not protected against water jets; DO NOT CLEAN
OVERHEAD WARMER WITH A WATER JET. Always clean equipment before first use.
3. SPECIFICATIONS
Electrical:
A. Single-phase operation at 120,208, 230, and 240 volts. (See label on each unit).
B. Field-wired units provided with 7/8" conduit hole, 6" long leads, and porcelain wire nuts. For supply
connections, use minimum no. 14AWGcopper wires suitable for at least 90ºC.
C. U.S. cord-connectedunits provided with following plug configuration:
1. 120 volt up to1440 watts = NEMA 5-15P; 120 voltup to 1920 watts = NEMA 5-20P
2. 208 volt up to2496 watts = NEMA 6-15P; 208 voltup to 3328 watts = NEMA 6-20P
3. 240 volt up to2880 watts = NEMA 6-15P; 240 voltup to 3840 watts = NEMA6-20P
DEuropean cord-connected units provided with following plug configuration:
1. Continental Europe230 volt up to 3600 watts = Schuko CEE7/7
2. UK230 volt up to2930 watts = Bs1363
If the supply cord is damaged, an authorized service agent or a similarly qualified person must replace it to
avoid a hazard or voiding the warranty.
4
Page 5
WARNING: ELECTRICAL SHOCK HAZARD. FAILURE TO FOLLOWTHE
INSTRUCTIONS IN THIS MANUAL COULD RESULT IN SERIOUS INJURY OR
!
DEATH.
Electrical Ground is required on this appliance.
Do not modify the power supply cord plug. If it does not fit into the outlet, have
the proper outlet installed by a qualified electrician
Do not use an extension cord with this appliance.
Check with a qualified electrician if you are unsure as to whether the appliance
is properly grounded.
Overall Dimensions:
!
FD MODELS
OVERHEAD WARMER LENGTH
18.00 [45.72] TO 72.00 [182.88]
RATING LABEL
FDL MODELS
PILOT LIGHT
.75
[1.91]
[ 23.18 ]
POWER LEADS
3.58
[9.09]
TOGGLE OR INFINITE SWITCH
9.125
10.048
[ 25.52 ]
.875 [ 2.22 ] CONDUIT HOLE
6.000
[ 15.24 ]
6.923
[ 17.58 ]
MOUNTING BRACKETS
FDD, FDDL MODELS
1.00
[2.55]
15.125
[ 38.42 ]
[ 43.11]
16.971
TUBULAR STAND KIT
FOR INSTALLATION ABOVE NONCOMBUSTIBLE SURFACE
1.00[2.54] SQUARE
S/S TUBING
5/16 -18 STUD MOUNT
OVERHEAD WARMER LENGTH + 1.06[2.7]
16.00
[
40.64
[ 46.99
]
18.50
PORTABLE LEG KIT
FOR USE ABOVE NONCOMBUSTIBLE SURFACE
]
1.00[2.54] SQUARE
S/S TUBING
OVERHEAD WARMER LENGTH + 2.06[5.23]
16.00
[
40.64
18.50
]
[
46.99
]
11.00[27.94]
11.27[28.63]
5
Page 6
4. Operation
A. All foodservice equipment should be operated by trained personnel.
B. Do not allow your customers to come in contact with any surface labeled “CAUTION HOT”.
C. Switch on unit. Place precooked product under heat source. Maximum heat coverage equivalent to
unit length.
D. Never holdfood below 150ºF.
5. Cleaning
General Cleaning Instructions:
A. Never clean any electrical unit by immersing it in water.
B. Never clean any electrical unit using water jets.
C. Disconnect power before cleaning or servicing units.
authorized service agency.
D. Clean unit daily. Use warm, soapy water. Mild cleansers and non-abrasive pads may be used to
remove baked-on food.
Turn off before surface cleaning.
All service should be performed by an APW
6. Troubleshooting
A. Always ask and check:
1. Is the unit connected to a live power source?
2. Check the circuit breaker.
3. Is the power switch on and pilot light illuminating?
4. Check the rating label. Is the unit operating on proper voltage?
B. If the above checks out, and problems still exist, call an APW Wyott authorized service agency.
C. All service should be performed by an APW Wyott authorized service agency.
6
Page 7
GREEN
G
120V: WHITE
200-240V: BLUE
BROWN
7. WIRING DIAGRAMS
FD18-72 WIRING DIAGRAM
REMOTE CONFIGURATION
ELEMENT
INFINITE CONTROL CONFIGURATION
INFINITE
CONTROL
L1
G
GREEN
BROWN
PL1L
H2
H1
DISPLAY LIGHT
INDICATOR LIGHT
2
L
H1
200-240V:BLUE
120V:WHITE
2
PILOTLIGHT
BLUE
BROWN
ELEMENT
PILOT
HEATING ELEMENT
L2
H2
L1
L2
EGO
INFINITE
CONTROL
L1
TOGGLE SWITCH CONFIGURATION
GL1L
2
GREEN
BROWN
200-240V: BLUE
120V: WHITE
TOGGLE
SWITCH
PILOT
LIGHT
BLUE
BROWN
ELEMENT
67177REV-11/2001
7
Page 8
FDL18-72 WIRING DIAGRAM
REMOTE CONFIGURATION
TWO L AMPHOLDERSONE L AMPHOLDE R
18,24,30 MODELS
36,42,48,54 MODELS
THREE LAMPHOL DERS
60, 66,72 MODELS
FOUR LAMPHOL DERS
84,96 MODELS
ABELS
L
N/L2
ABELS
L
N/L2
N/L2
L1
G
L1
G
L1
200-240V: BLUE
4
5
1
120V: WHITE
200-240V: BLUE
2
3
DISPLAY LIGHT
H1
120V:WHITE
200-240:BLUE
BROWN
GREEN
INFINITE
CONTROL
120V: WHITE
BROWN
GREEN
BROWN
PILOT
1
PL1L2
H1
7
54
BROWN
WHITE
6
INFINITE CONTROL CONFIGURATION
HEATING ELEMENT
INDICATOR LIGHT
L2
H2
EGO
INFINITE
L1
CONTROL
32
6
PILOT
H2
LIGHT
BLAC K
L2
L1
BLUE
7
18,24,30MODELS
WHITE
8
BLUE
BLUE
WHITE
6
BLACK
9
BLACK
BLUE
7
ELEMENT
TWOLAMPHOLDERSONELAMPHOLDER
36,42,48,54MODELS
BLUEBLUE
WHITE
BLACK
WHITE
6
BLACK
99
ELEMENT
BROWN
BLUE
7
THREELAMPHOLDERS
60,66,72MODELS
WHITE
88
WHITE
BLACK
BLAC K
FOURLAMPHOLDERS
84,96MODELS
BLACKWHITE
BLUE
TOGGLE SWITCH CONFIGURATION
ABELS
N/L2
L1
G
120V: WHITE
200 -240V: BLU E
BROWN
GREEN
TOGGLE
SWI TCH
1
7
2 3
54
BLUE
6
BROWN
18, 24,30 MODELS
WHITE
8
PILO T
LIGHT
L
BLACK
9
BLUE
BLUE
TWO LAMPHOLDERSONE LAMPH OLDER
36,42,48,54 MODELS
WHITE
BLAC K
8
9
8
BLUE
BROWN
THRE E LAMPH OLDERS
60, 66,72 MODELS
WHITE
BLACK
8
9
ELEMEN T
BLUE
FOUR LA MPHOLDERS
84, 96 MODELS
WHITE
BLACK
Page 9
LABELS
N/L2
L1
FDD18-72 WIRING DIAGRAM
120V: WHITE
200-240V: BLUE
BROWN
REMOTE CONFIGURATION
ELEMENT
LABELS
N/L2
L1
G
G
N/L2
L1
200-240V:BLUE
120V:WHITE
BROWNGREEN
200-240V: BLUE
PL1L2H1
H2
GREEN
120V: WHITE
BROWN
INFINITE CONTROL CONFIGURATION
PL1L2
H1
PILOTLIGHT
H2
PILOTLIGHT
BLUE
BLUE
BROWN
ELEMENT
BROWN
ELEMENT
ELEMENT
DISPLAY LIGHT
H1
L2
PILOT
HEATING ELEMENT
INDICATOR LIGHT
H2
EGO
INFINITE
L1
CONTROL
L2
L1
LABELS
TOGGLE SWITCH CONFIGURATION
9
Page 10
FDDL18-72 WIRING DIAGRAM
LABELS
N/L2
120V:WHITE
200-240:BLUE
BROWN
L1
GREEN
G
LABELS
N/L2
L1
N/L2
L1
G
N/L2
L1
INFINITECONTROL
120V:WHITE
200-240:BLUE
120V:WHITE
200-240:BLUE
BROWNGREEN
120V:WHITE
200-240:BLUE
BROWN
REMOTE CONFIGURATION
BROWN
1LAMPHOLDER
18,24,30MDLS
WHITE
BLACK
2LAMPHOLDERS36,42,48,54MDLS
WHITE
BLUE
ELEMENT
BLACK
ELEMENT
3LAMPHOLDERS
BLUE
60,66,72MDLS
WHITE
INFINITE CONTROL CONFIGURATION
L1
P
L2
H1
H2
1LAMPHOLDER
18,24,30MDLS
PILOTLIGHT
BLUE
2LAMPHOLDERS
36,42,48,54MDLS
ELEMENT
BROWN
3LAMPHOLDERS
60,66,72MDLS
3LAMPHOLDERS
84MDL
BLACK
4LAMPHOLDERS
WHITE
BLUE
DISPLAY LIGHT
84,96MDLS
BLACK
HEATING ELEMENT
INDICATOR LIGHT
L2
L2
INFINITECONTROL
L1
PH1
BROWN
BLUE
WHITE
BLACK
BLUE
WHITE
BLACK
BLUE
WHITE
BLACK
BLUE
WHITE
BLACK
H1
PILOT
L2
H2
PILOTLIGHT
BLUE
ELEMENT
BROWN
H2
L1
EGO
INFINITE
CONTROL
L1
TOGGLE SWITCH CONFIGURATION
TOGGLE
LABELS
N/L2
120V:WHITE200-240:BLUE
BROWN
L1
GREEN
G
SWITCH
TOGGLESWITCH
BROWN
PILOTLIGHT
1LAMPHOLDER
18,24,30MDLS
WHITE
BLACK
BLUE
PILOTLIGHT
BLUE
BROWN
2LAMPHOLDERS36,42,48,54MDLS
WHITE
BLUE
BROWN
BLACK
BLUE
ELEMENT
3LAMPHOLDERS
60,66,72MDLS
WHITE
BLACK
BLUE
ELEMENT
4LAMPHOLDERS
84,96MDL
WHITE
BLACK
67179REV-7/00
10
Page 11
8. PARTS LISTS
MODEL “FD” OVERHEAD WARMERS REPLACEMENT PARTS CATALOG
FD Followed by 18, 24, 30, 36, 42, 48, 54, 60, 66, 72, 84, or 96