APW Wyott EF-30NTC, EF-30NT User Manual

R
INSTALLATION AND OPERATING INSTRUCTIONS
ELECTRIC FRYERS
Models: EF-15N, EF-30NT, EF-30NTC
INTENDED FOR OTHER THAN HOUSEHOLD USE
RETAIN THIS MANUAL FOR FUTURE REFERENCE
OVEN MUST BE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES
FOR YOUR SAFETY
! !
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WARNING
Improper installation, adjustment, alteration, service or maintenance can
! !
cause property damage, injury or death. Read the Installation, Operating and Maintenance Instructions thoroughly before installing or servicing this equipment.
WARNING
Initial heating of oven may generate smoke or fumes and must be done in a
! !
This equipment has been engineered to provide you with year round dependable service when used according to the instructions in this manual and standard commercial kitchen practices.
well-ventilated area. Overexposure to smoke or fumes may cause nausea or dizziness.
APW WYOTT Foodservice Equipment Company
P.O. Box 1829
Cheyenne, WY 82003 (307) 634-5801 Phone (800) 752-0863 Toll Free (307) 637-8071 Fax www.apwwyott.com
1
APW Wyott
care and maintenance, you will experience years of reliable operation from this equipment. To ensure best results, it is important that youread and follow the instructions in this manual carefully.
Installation and start-up should be performed by a qualified installer who thoroughly read, understands and follows these instruction. If you have questions concerning the installation, operation, maintenance or service of this product, write Technical Service Department APW Wyott Foodservice Equipment Company, P.O. Box 1829, Cheyenne, WY 82003.
takes pride in the design and quality of our products. When used as intended and with proper
SAFETY PRECAUTIONS
Before installing and operating this equipment be sure everyone involved in its operation are fully trained and are aware of all precautions.Accidents and problems can result by a failure to follow fundamental rules and precautions.
The following words and symbols, found in this manual, alert you to hazards to the operator, service personnel or the equipment. The words are defined as follows:
DANGER:
!
WARNING:
!
seriousinjuryordeath.
CAUTION:
moderateinjuryorproductorpropertydamage.
!
NOTICE:
eventhoughnotdangerous.
!
Thissymbolwarnsofimminenthazardwhichwillresultin seriousinjuryor death.
This symbol refers to a potential hazard or unsafe practice, which could result in
Thissymbol refers to a potentialhazard or unsafe practice, which mayresult in minor or
This symbol refers to informationthatneeds special attention or must be fully understood
GENERAL INFORMATION
THIS MANUAL SHOULD BE RETAINED FOR FUTURE REFERENCE
CAUTION:
positioned so the general public can use the equipment make sure that cautions, warnings, and
!
operating instructions are clearly posted near each unit so that anyone using the equipment will useit correctlyand not injure themselvesor harm the equipment.
WARNING:
!
andfrequencylistedonthedataplate.Connectonlyto1 or 3 phase as listedonthedataplate.
WARNING:
!
nationalelectricalcodeand/orotherlocalelectricalcodes.
These models are designed, built, and sold for commercial use. If these models are
Checkthe dataplate on this unit beforeinstallation.Connecttheunitonlyto the voltage
Electrical and grounding connections must comply with the applicable portions of the
!
!
!
!
!
!
!
WARNING:
!
powerplug,indicatingthatyouareworkingonthe circuit.
WARNING:
strongly recommend having a competent professional install the equipment. A licensed electrician should make the electrical connections and connect power to the unit. Local codes should always
!
be used when connecting these units to electrical power. In the absence of local codes, use the latestversionofthe NationalElectricalCode.
WARNING:
codes, or in the absence of local codes, with the National Electrical code, ANSI/NFPA70, Latest Edition to protect the user from electrical shock. It requires a grounded system and a dedicated
!
circuit, protected by a fuse or circuit breaker of proper size and rating. Canadian installation must complywiththeCanadianElectricalCode,CSAC22.2,as applicable
Disconnect device from electrical power supply and place a Tag Out-Lockout on the
Installper the spacing requirements listed in the installation section of this manual. We
This device should be safely and adequately grounded in accordance with local
2
!
!
!
CAUTION:
!
unlessthereisat least 3 breathing spacebehindfryer.
Do not set the fryer with its back flat against the wall. It will not operate properly
!
WARNING:
!
maintenanceor repair,contactAPW Wyott.
WARNING:
!
surface.
WARNING:
installationand from there to an independentearth connection.
!
NOTICE:
the absence of local codes, with the national electrical code ANSI/NFPA70- latest edition.
!
Canadian installation must comply with CSA-STANDARD C.22.2 Number 0 M1982 General Requirements-CanadianElectrical Code Part II, 109-M1981-Commercial CookingAppliances.
WARNING: -
!
equipment.
NOTICE:
!
NOTICE:
Fire ProtectionAssociation, Inc. states in its NFPA96 latest edition that local codes are Authority Having Jurisdiction when it comes to requirement for installation of equipment. Therefore,
!
installationshould comply with all local codes.
Afactory authorized agent should handle all maintenanceand repair. Before doing any
Never clean any electrical unit by immersing it in water. Turn off before cleaning
An earthing cable must connect the appliance to all other units in the complete
The unit when installed, must be electrically grounded and comply with local codes, or in
SHOCK HAZARD
Thisproductisintendedforcommercialuse only. Not for household use.
Local codes regarding installation vary greatly from one area to another. The National
De-energize all power to equipment before cleaning the
!
!
!
!
!
!
!
CAUTION:
!
Disconnectall power supplies before servicing.
CAUTION:
!
provided.
WARNING: -
!
This product when stacked, has more than one power supply connection point.
Suitable for installation on combustible floor when installed with legs or casters
SHOCKHAZARD
Donot open any panelsthat requirethe use of tools.
!
!
!
IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/orParts, this information is required.
Model Number Serial Number Date Purchased
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
All containers should be examined for damage before and during unloading. The freight carrier has assumed responsibility for its safe transit and delivery. If equipment is received damaged, either apparent or concealed, a claim must be made with the delivering carrier. A) Apparent damage or loss must be noted on the freight bill at the time of delivery. It must then be signed by the carrier representative (Driver). If this is not done, the carrier may refuse the claim. The carrier can supply the necessary forms. B) Concealed damage or loss if not apparent until after equipment is uncrated, a request for inspection must be made to the carrier within 15 days. The carrier should arrange an inspection. Be certain to hold all contents and packaging material.
Installation and start-up should be performed by a qualified installer who thoroughly read, understands and follows these instructions.
3
TABLE OF CONTENTS
SECTION ITEM PAGE
1 General Information & Troubleshooting 4 2 Description 5 3 Installation 5 4 Thermostat Calibration 5 5 Operation 6 6 Maintenance 6 7 Cleaning 7 8 Wiring Diagrams 8 9 Troubleshooting Guide 10 10 Suggested Temperature & Times 11 11 Replacement Parts 11 12 Warranty 16
1. GENERAL INFORMATION
General Installation:
1. Always clean equipment thoroughly before first use (see “General Cleaning Instructions”).
2. Check rating label for your model designation & electrical rating.
3. For best results, use stainless steel countertops.
4. Attach legs to unit.
General Operation Instructions:
1. All foodservice equipment should be operated by trained personnel.
2. Do not allow your customers to come in contact with any surfacelabeled “CAUTION HOT”.
3. Where applicable, never pour cold water into dry heated units.
4.
General Cleaning Instructions:
1. Refer to section 7, page 7.
General Troubleshooting:
Always ask and check:
1. Is the unit connected to a live power source?
2. Check circuit breaker.
3. Is power switch “ON” and pilot light glowing?
4. Check rating label.Are you operating unit on proper voltage?
If the above checks out and you still have problems, call an APW/Wyott authorized service agency.
NEVER hold food below 140°F.
4
2. DESCRIPTION
Electric Fryers:
These electric units are designed for countertop operation. They are used for producing evenly cooked, perfectly fried products.
3. INSTALLATION
1. Follow General Installation Instructions on previouspage.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand. Level the fryer by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs mounted, lift if necessary tomove unit.
For testing, see the wiring diagrams in this manual for the rated amperages.
NOTE:
These values are nominal ratings. Field wire connections must be capable of withstanding
anticipated surges.
CAUTION:
!
(LatestEdition), and applicable local codes..
Installing personnel should be guided by National Electrical Code NFPA Number 70-
!
4. THERMOSTAT CALIBRATION
Checking Thermostat Calibration:
The fryer thermostat is carefully calibrated at the factory so that dial settings match actual frying compound temperatures. Field re-calibration is seldom necessary unless the unit has been mishandled in transit or abused. Re-calibration should not be resorted to unless considerable experience with cooking results definitely proves that the control is not maintaining the temperatureto which the dial is set.
1. To check compound frying temperatures when re-calibrating, use a precision test instrument, or a
good grade mercury thermometer. Fill the tank half way between the and marks on the tank.
2. Frying compound temperature should be checked at the center of the tank, approximately 1” to
1 1/2” below surface of frying compound.
3. Turn the dial of the thermostat being checked to the 350°F mark.
4. Allow temperature to stabilize, or until the thermostat cycles to “OFF” three times after starting
with cold frying compound. With power “ON”, read highest and lowest frying compound temperature, as thermostat cycles through at least two cycles.Average the reading.
5. Thermostat should be re-calibrated if temperature reading is not within 10 degrees of the
control knob setting (350°F +/- 15°F). Ifre-calibration is required, continue with steps 6, 7, 8 and9.
6. Remove control knob by graspingouter edge and pullingstraight out, without twisting or turning.
7. Hold thermostat dial shaft “B” (Figure 1) stationary with pliers, and with a screwdriver, turn screw “A”
clockwise to obtain a lower temperature; or counter-clockwise for higher temperature. Each ¼ turn (90° rotation) of screw “A” represents 18°F.
8. Replace thermostat control knob.
9. Recheck thermostat as in Steps 4 and 5 above. If the fat temperature is not within 20 degrees of dial
setting (350°F +/- 20°F), it means that the sensing element is inoperative and the thermostatic control should be replaced.