APW Wyott CHDT-2 Specifications

CHDT 2 thru 6
Cold Hot Dual Temperature Wells
PRODUCT: QUANTITY: ITEM
Designed Smart
Bid Specification
The APW Wyott Cold/Hot Dual Temperature Wells combines the sophistication of electrically heating, with the technology to turn into a contained refriger­ated cold pan. With one flip of the switch, the CHDT goes from hot to cold!
The CHDT system contains automatic water fill, high limited thermostat protector; NSF-4 electric required standard immersion heating system; flex­ible 24’’ conduit for optional counter mounting which connects to stainless steel control panel; and the ability for installation into metal or wooden coun­ters. The CHDT is available in 5 different models (HFDW-2 thru 6), which allows the choice of holding 2 up to 6 standard pans. CHDT heavy-duty stain­less steel’s allows for superior durability and ulti­mate strength. It’s built solid to last.
Model: CHDT-2 CHDT-3 CHDT-4 CHDT-5 CHDT-6
Cold Hot Dual Temperature Wells MODEL CHDT-4
APW Wyott Design Features
• Quick and hassle free entry for function controls and temperature gauges
• Quicker refrigeration (larger compressors), and heating (immediately shifts heat by water
APW Wyott’s CHDT systems Inc. LISTED, Underwriters Laboratories*, meets NSF International* and Canadian standard.*
Reliability backed by APW Wyott’s Warranty
•APW Wyott’s Food Wells are backed by 1 year parts and labor warranty
*CHDT Certification Pending
• Handles products at selected temperature (cold or hot)
• Features spacious one inch drainage system, and screen
• Heating feature has to be used in wet operation.
Options
2 to 6 Standard Inset Pans
Installation in Metal or Wooden Counter
See reverse side for product specifications.
Rev. 01/2008
Cold Hot Dual Temperature Wells
Model: CHDT-2 CHDT-3 CHDT-4 CHDT-5 CHDT-6
PRODUCT: QUANTITY: ITEM #:
Cold Hot Dual Temperature Well (Model CHDT-3 Shown)
Top View
25 7/8 (657)
CHDT 2 thru 6
5/16 (8)
3 (76)
1/4"NPT Water
Line Connection
MODEL
CHDT-2 CHDT CHDT CHDT CHDT
MODEL
CHDT
CHDT
CHDT
CHDT
CHDT
B A
1 1/8" Dia. Conduit K.O.
Term i n a l Block Connection
27 1/8 (689)
8 5/8 (219)
10 3/8 (264)
1" NPT
Drain
19 (505)
23 (584)
DIMENSIONS
A B C (CUTOUT)
INCHES MM INCHES MM INCHES MM
32 3/4
-3
-4
-5
-6
i1/2
46 60 1/4 74 87 3/4
832 1181 1530 1880 2229
25 1/2 39 1/4 53 66 3/4 80 1/2ii
648
997 1346 1695 2045
ELECTRICAL
WARMER REFRIGERATION
AMPS (1 PHASE)
VOLTS
KW
L1 - L2
208
-2 240
208
-3 240
208
-4 240
208
-5 240
208
-6 240
1.9
2.5
3.0
4.0
3.8
5.0
6.0
8.0
6.0
8.0
9.0
10.4
14.4
16.7
18.1
20.8
28.9
33.3
28.9
33.3
N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A. N.A.
VOLTS
N
120
120
120
120
120
HP
1/4
1/3
1/2
3/4
3/4
1 (25)
24 3/8 (620)
31 1/2 45 1/4 59 72 3/4 86 1/2ii
AMPS (1 PHASE)
L2 - N
5.5
7.0
7.5
15.3
15.3
800 1149 1499 1848 2197
N/A
N/A
N/A
N/A
N/A
CUTOUT
3 (76) Minimum
REFRIGERANT
L1
Front Access Required For
Controls
Floor Level
BACK
0” (0 mm)
TYPE
R-134-A
R-404-A
R-404-A
R-404-A
R-404-A
C
Cross Section - Side View
CLEARANCES
MINIMUM CLEARANCE REQUIRED FROM UNIT
TO THE NEAREST SURFACE
SIDE
0” (0 mm)
BOTTOM
N/A
FRONT
3” (76 mm)
SINGLE PHASE SUPPLY
3 WIRE 120/208-240V
L1-L2 208-240V
L2-N 120VAC 60 HZ
ALL MODELS
PERMANENTLY
CONNECTED
*APW Wyott reserves the right to modify specifications or discontinue models without incurring obligation.
Rev. 1/2008#