1.1. Purpose.................................................................................................................................3
1.2. Box Contents........................................................................................................................3
1.3. Conventions used in this manual......................................................................................3
2.1. LED indications....................................................................................................................4
3.1. Multiverter Firmware Check...............................................................................................5
4.1. Connection...........................................................................................................................6
4.2. Connecting two MTA-64s...................................................................................................6
4.3. Software setup....................................................................................................................7
Web .................................................................................................................................7
Front panel .....................................................................................................................8
Command line ...............................................................................................................8
5.1. Changing the MTA-64's address via jumper...................................................................10
5.2. Pinswap cable....................................................................................................................10
6. SPECIFICATIONS.......................................................................................................................11
7. APPENDIX..................................................................................................................................12
7.1. Warranty..............................................................................................................................12
7.2. Manufacturer contact........................................................................................................12
7.3. FCC Compliance.................................................................................................................12
7.4. Recycling............................................................................................................................13
7.5. Document Revision History..............................................................................................13
7.6. About this document.........................................................................................................13
2
Page 3
MVR-64

1. GENERAL

1.1. Purpose

With the MTA-64, the multiverter becomes capable of connecting to the MADI-TP variants used in DiGiCo and Soundcraft/Studer/Harman desks, which - although not ocially standardized - have gained widespread acceptance because they are built into many desks and stageboxes. The MTA-64s relay logic eliminates the need for crossover cables and allows to use standard straight (1:1) cabling in all situations.
The MTA-64 connects to the multiverter's MADI-TP port (for the audio transmission) and to the EXTENSION port (for power supply and mode control). The EXTENSION port is fed through on the MTA-64 to allow other extension boxes (e.g. for AVB) to connect to the multiverter simultaneously. Optionally, a second MTA-64 may be connected to the MVR-64 to add another MADI-TP port (instead of the AES50 port).

1.2. Box Contents

1 MTA-64 Adapter Box1 Cat5 cable 0.5m / 1.7 ft 1 HDMI cable 0.5m / 1.7 ft with locking screwsThis manual

1.3. Conventions used in this manual

A button on the front of the multiverter is shown like this: Set A particular LED on the front of the device is shown like this: WCLK
Text indicated on the seven-segment display is shown as 02Operations in a particular control method are indicated by a triangle:
Front panel, Web or Command line
Filled circles with an exclamation mark indicates an action that must be performed (“Required”).
A section marked with a “information” icon indicates a useful tip.
3
Page 4
User's Manual

2. DEVICE DESCRIPTION

Top view
Connectors on "MVR" side Connectors on "Console/Stage" side

2.1. LED indications

LED Meaning
 DiGiCo (blue) DiGiCo mode selected
Sc/St (white) Soundcraft/Studer/Harman mode selected
MDIX (yellow) Crossover configuration (Receive/Transmit swapped).
When lit, a crossover cable is emulated on the "Console/Stage" port.
RxD (green) Receive Data OK (same as MADI-TP "green" indication on MVR front).
When lit, the MTA-64 is configured correctly and receives a signal
4
MVR-64 Extension-Port
MVR-64 MADI-TP Port
Optional: Extension­Box or 2nd MTA-64
Console or Stagebox MADI-TP Port
Page 5
MVR-64

3. PREREQUISITES

3.1. Multiverter Firmware Check

The multiverter requires at least firmware 4.0 for the MTA-64 to work. Please check and update if required (see below).
To check the multiverter's firmware version: Press Recall , move to
Function , press OK , move to 12 , press OK , move cursor to AD .
If the seven-segment display shows 04 or higher, no update is required.
If 03 or less is shown, a firmware update is required. Download the firmware
update from our website and follow the instructions in the README.TXT file contained in the package.
5
Page 6
User's Manual

4. OPERATION

4.1. Connection

Connect the Cat5 port on the MVR side of the MTA-64 to the MADI-TP port of
the multiverter
Connect the Extension port on the MVR side of the MTA-64 to the Extension port
of the multiverter
Connect the Cat5 port on the Console / Stage side of the MTA-64 to the console
or stagebox:

4.2. Connecting two MTA-64s

The second MTA-64 needs to be jumpered to address 2 and connected to the
AES50 port (which must be set to MADI-TP mode). A pinswap cable is required between the AES50 port and the MTA-64. See chapter 5."Configuring the second MTA-64" for details.
6
MVR-64 multiverter
MVR-64 multiverter
MTA-64
MTA-64
Cat5
Console
or Stagebox
Console
or Stagebox
Cat5
HDMI
Extension
MADI-TP
(optional)
Extension
Box (e.g. AVB)
Extension
Box (e.g. AVB)
MVR-64 multiverter
MVR-64 multiverter
MTA-64
MTA-64
Cat5
Console
or Stagebox #1
Console
or Stagebox #1
Cat5
HDMI
Extension
MADI-TP
Extension
Box (e.g. AVB)
Extension
Box (e.g. AVB)
MTA-64
(address 2)
MTA-64
(address 2)
Console
or Stagebox #2
Console
or Stagebox #2
Cat5
(pinswap)
HDMI
Cat5
AES50
(in TP mode)
Page 7
MVR-64

4.3. Software setup

The easiest way of setting up the MTA-64 is by using the multiverter's web configuration. Simply type the IP address of the Dante module in your web browser and open the SETTINGS page.
Web
The settings [04] and [05] can be altered on the "SETTINGS" page:
7
Page 8
User's Manual
Front panel
The mode setting is available through the "Function" menu. To adjust the value:
Press the blue Recall buttonMove the cursor to Function by turning the encoder left or rightConfirm OK (push the encoder)The Function LED should now be lit.Move the cursor to index 4 (MADI-TP operation mode) and push the
encoder knob*. The seven-segment display is now blinking, indicating the current mode number (see Table 1 on page 9)
Rotate the encoder to alter the valueConfirm OK (push the encoder) or press Back to cancel the operation.
Command line
function 04 <value>
with <value> according to Table 1 on page 9 *
* Index 05 is used to configure a second MTA-64 connected to the AES50 port
8
Page 9
MVR-64
Value Mode Num.Ch96k frame
format
Pinout mode Remarks
00 AES-X213 56 48k Auto connect directly (without MTA-64)
01 96k
02 64 48k
03 96k
04 AES50 48 - connect directly (without MTA-64),
use pinswap cable
08 DiGiCo 56 48k Straight
09 96k
10 64 48k
11 96k
12 Soundcraft/Studer 56 48k
13 96k
14 64 48k
15 96k
24 DiGiCo 56 48k MDIX (Crossover)
25 96k
26 64 48k
27 96k
28 Soundcraft/Studer 56 48k
29 96k
30 64 48k
31 96k
32 AES-X213 57 48k Auto connect directly (without MTA-64)
33 96k
40 DiGiCo 57 48k Straight
41 96k
44 Soundcraft/Studer 57 48k
45 96k
56 DiGiCo 57 48k MDIX (Crossover)
57 96k
60 Soundcraft/Studer 57 48k
61 96k
Table 1: Mode numbers (numbers not listed are reserved)
9
Page 10
User's Manual

5. CONFIGURING THE SECOND MTA-64

5.1. Changing the MTA-64's address via jumper

The second MTA-64 needs to be jumpered internally to address "2". The jumper is located on the internal PCB. To access it:
1. Remove the four screws (two upper screws on each side).
2. Remove the top cover.
3. Locate the jumper on the top and change it to position "2":

5.2. Pinswap cable

The AES50 port has a dierent pinout and requires a pin swap Cat5 cable between the MVR-64 and the MTA-64. (Note: this is the same cable which is required to use the MADI-TP port as AES50).
10
Page 11
MVR-64

6. SPECIFICATIONS

Parameter Value
Dimensions 83x39x52mm (WxHxD)
Weight 128 g
Operating temperature
0..+70°C, non-condensing
Storage temperature -40..+85°C, non-condensing
Power consumption +15V DC from multiverter, 2W max.
Cable lengths MVR-64 to MTA-64 / Cat5 5m max.
MVR-64 to MTA-64 / HDMI 5m max.
MTA-64 to Console/Stagebox 70..100m
(depends on cable quality and counterpart)
Channel count Up to 64x64 in x1 modes (44.1 / 48 kHz)
Up to 32x32 in x2 modes (88.2 / 96 kHz) Up to 16x16 in x4 modes (176.4 / 192 kHz)
Sample rates Arbitrary sample rates between 32kHz and 192kHz
Remote Control Data Transparent forwarding of DiGiCo remoting data (contained in ch57),
Soundcraft/Studer remoting data (userbits of ch1-10) and others
Latency The latency added by the MTA-64 is negligible (in the nanoseconds range)
Pinout Pin number/
color
MVR side Console/Stage side
DiGiCo DiGiCo MDIX Soundcraft Soundcraft
MDIX
1 (orange/wt) TX+ RX+ TX+ RX+
2 (orange) TX- RX- TX- RX-
3 (green/wt) RX+ TX+
4 (blue/wt) TX+
5 (blue) TX-
6 (green) RX- TX-
7 (brown/wt) RX+ RX+ TX+
8 (brown) RX- RX- TX-
Note: The signals on the "MVR" side are electrically dierent from the "Console/Stage" side.
11
Page 12
User's Manual

7. APPENDIX

7.1. Warranty

We oer a full two (2) year warranty from the date of purchase. Within this period, we repair or exchange your device free of charge in case of any defect*. If you experience any problems, please contact us first. We try hard to solve your problem as soon as possible, even after the warranty period. * Not covered by the warranty are any damages resulting out of improper use, willful damage, normal wear-out (especially of the connectors) or connection with incompatible devices.

7.2. Manufacturer contact

Appsys ProAudio Rolf Eichenseher Bullingerstr. 63 / BK241 CH-8004 Zürich Switzerland
www.appsys.ch info@appsys.ch Phone: +41 43 537 28 51 Mobile: +41 76 747 07 42

7.3. FCC Compliance

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antennaIncrease the separation between the equipment and receiverConnect the equipment into an outlet on a circuit dierent from that to which
the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
This equipment has been verified to comply with the limits for a class B computing device, pursuant to FCC Rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications
12
Page 13
MVR-64
made to the equipment without the approval of manufacturer could void the user’s authority to operate this equipment.

7.4. Recycling

According to EU directive 2002/96/EU, electronic devices with a crossed-out dustbin may not be disposed into normal domestic waste. Please return the products back for environment-friendly recycling, we'll refund you the shipping fees.

7.5. Document Revision History

2: Corrected 96k frame format in Table 1 1: Initial release