Information in this document is subject to change without notice. Applied Biosystems assumes no responsibility for any errors that may appear in this
document.
APPLIED BIOSYSTEMS DISCLAIMS ALL WARRANTIES WITH RESPECT TO THIS DOCUMENT, EXPRESSED OR IMPLIED, INCLUDING
BUT NOT LIMITED TO THOSE OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL APPLIED
BIOSYSTEMS BE LIABLE, WHETHER IN CONTRACT, TORT, WARRANTY, OR UNDER ANY STATUTE OR ON ANY OTHER BASIS FOR
SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING
FROM THIS DOCUMENT, INCLUDING BUT NOT LIMITED TO THE USE THEREOF.
NOTICE TO PURCHASER:LIMITED LICENSE
The combination of the GeneAmp® PCR System 9700 Sample Block Module with a GeneAmp® PCR System 9700 Base Unit is licensed under patent
claims for thermal cycler apparatus and counterpart patent claims in other countries. No other rights are conveyed expressly, by implication, or by
estoppel. Further information on purchasing licenses may be obtained by contacting the Director of Licensing, Aplied Biosystems, 850 Lincoln Centre
Drive, Foster City, California 94404, USA.
TRADEMARKS:
AB (Design), Applied Biosystems, and MicroAmp are registered trademarks, Applera and Celera Genomics are trademarks of Applera Corporation or
its subsidiaries in the U.S. and/or certain other countries.
GeneAmp is a registered trademark of Roche Molecular Systems, Inc.
All other trademarks are the sole property of their respective owners.
IMPORTANT Read this section before you install the GeneAmp
the 0.5-mL Sample Block Module.
The following symbols are used on Applied Biosystems instruments. Whenever such
symbols appear on instruments, please observe appropriate safety procedures.
Electrical Symbols
This symbol indicates the on position of the main power switch.
This symbol indicates the off position of the main power switch.
This symbol indicates the on/off position of a push-push main power switch.
This symbol indicates that a terminal may be connected to another
instrument’s signal ground reference.
This is not a protected ground terminal.
This symbol indicates that this is a protected ground terminal that must be
connected to earth ground before any other electrical connections are made
to the instrument.
®
PCR System 9700 and
~
~
This symbol indicates that this terminal either receives or delivers alternating
current or voltage.
This symbol indicates that this terminal either receives or delivers alternating
and direct current or voltage.
0.5-mL Sample Block Module 1-1
Non-electrical Symbols
This symbol indicates the presence of high voltage and warns the user to
proceed with caution.
This symbol alerts you to consult the manual for further information and to
proceed with caution.
This symbol illustrates a heater hazard. Proceed with caution when working
around these areas to avoid being burned by hot components.
Electrical Safety
Testing
Instrument Labels
Routine safety testing of analytical instruments ( e.g. , high potential voltage testing)
may be required by various safety agencies.
Testing should only be carried out by qualified personnel after seeking
advice from the Applied Biosystems Service Department.
The following instrument labels are on the system 9700 with the 0.5-mL Sample Block
Module installed.
! WARNING !
circuit continuity is vital for safe operation of equipment. Ne ver operate
equipment with grounding conductor disconnected.
AVERTISSEMENT: Debrancher le cordon d’alimentation avant d’ouvrir la
continuite des masses est essentielle.
Pour un fonctionnement sans danger. Ne jamais utiliser l’equipment si le fil
de terre n’est pas raccorde.
\
! WARNING !
area to avoid being burned by hot components.
Attention. Surface chaude.
Disconnect supply cord before opening. Grounding
Hot Surface. Use care when working around this
1-2 0.5-mL Sample Block Module
Operating Precautions
Precautions
The following precautions should be taken whenever you operate the system 9700
with the 0.5-mL Sample Block Module installed.
Note This instrument is able to withstand transient overvoltage according to Installation
Category II as defined in IEC 1010-1.
General Use
\
CAUTION The instrument should be used according to the
instructions provided in this manual. If used otherwise, the protection
provided by this instrument may be impaired.
Environment, Humidity, and Temperature
CAUTION This instrument is designed for indoor use.
CAUTION Do not operate in a Cold Room or a refrigerated area.
The system 9700 will operate safely when the ambient temperature is
5–40 °C (41–104 °F). The system 9700 will meet performance
specifications when the ambient temperature is 15–30 °C and the
ambient relative humidity is 20–80%. These specifications have been
calculated for altitudes between 0 and 2,000 meters.
CAUTION This instrument is not designed for operation in an
explosive environment. Do not place the instrument close to
potentially explosive materials or objects.
CAUTION This instrument is not designed for operation with the
heated cover retracted when running at 4 °C. If the heated cover is
retracted and the instrument runs at 4 °C, water condensation may
be excessive in the sample block area.
0.5-mL Sample Block Module 1-3
Sample Block Module
! WARNING !
heated cover or touch the sample block module when the word Hot
displays on the screen. This indicates a sample block temperature
above 50 °C.
The hot areas for the 0.5-mL Sample Block Module are shown below.
\
CAUTION To protect your samples and to guarantee the best
temperature uniformity, keep the heated cover closed at all times,
except when loading or unloading samples.
To protect yourself against burns, do not open the
Grounding and
Electrical Safety
Voltage Quality
Input/Output
Connections
Physical
Specifications
The system 9700 must be grounded for protection against electrical shock.
! WARNING !
this does not provide positive ground protection.
Refer to the GeneAmp
®
PCR System 9700 Base Module User’s Manual
Do not use an adapter to a two-terminal outlet since
(P/N 0993-6247) for more information on electrical safety.
Line voltage must be within
±
10% of the nominal value. High or low voltages may hav e
adverse effects on the electronic components of the instrument. In areas where the
supplied power is subject to fluctuations exceeding these limits , a pow er line regulator
may be required.
Refer to the GeneAmp
®
PCR System 9700 Base Module User’s Manual
(P/N 0993-6247) for information on the input and output connections of this
instrument.
Refer to the GeneAmp
®
PCR System 9700 Base Module User’s Manual
(P/N 0993-6247) for information on the physical specifications of this instrument.
1-4 0.5-mL Sample Block Module
Pollution Category
Instrument Storage
Communautes
Europeennes (CE)
Compliance
FCC Compliance
(U.S.)
Routine
Maintenance for
Safe Operation
The system 9700 will operate safely in environments that contain nonconductive
foreign matter up to Pollution Degree 2 in IEC 1010-1.
The system 9700 must be stored at a temperature between -20 °C and 60 °C
(-4 °F and 140 °F) at altitudes ranging from 0–12,000 meters above sea level.
IMPORTANT The system 9700 is guaranteed to meet performance specifications only
when the ambient temperature is 15–30 °C and the ambient relative humidity is 20–80%
(between altitudes of 0 and 2,000 meters).
\
All instruments shipped to the European Union (EU; formerly known as the
European Community) have the CE label on the bac k of the instrument. This
label signifies that these instruments comply with the Electromagnetic
Compatibility and Low Voltage Directives.
This product is classified as a digital device used exclusively as industrial,
commercial, or medical test equipment. It is exempt from the technical standards
specified in Part 15 of the FCC Rules and Regulations, based on Section 15.103(c).
Before using any cleaning or decontamination method, e xcept those recommended in
the manual, the user should check with Applied Biosystems to ensure that the
proposed method will not damage the equipment.
Maintain your instrument in good working order. In the event that the instrument has
been subjected to adverse environmental conditions (such as fire, flood, earthquake,
etc.), a service inspection of the instrument should be made to ensure safe operation.
0.5-mL Sample Block Module 1-5
Technical Support
To Reach Us on the
Web
Hours for Telephone
Technical Support
To Reach Us by
Telephone or Fax in
North America
Applied Biosystems web site address is:
http://www.appliedbiosystems.com/techsupport
We strongly encourage you to visit our web site for answers to frequently asked
questions, and to learn more about our products. You can also order technical
documents and/or an index of available documents and have them faxed or e-mailed
to you through our site (see the “Documents on Demand” section below).
In the United States and Canada, technical support is available at the following times.
ProductHours
Chemiluminescence9:00 a.m. to 5:00 p.m. Eastern Time
LC/MS9:00 a.m. to 5:00 p.m. Pacific Time
All Other Products5:30 a.m. to 5:00 p.m. Pacific Time
See the “Regional Offices Sales and Service” section below for how to contact local
service representatives outside of the United States and Canada.
Call Technical Support at 1-800-831-6844, and select the appropriate option (below)
for support on the product of your choice at any time during the call. (To open a
service call for other support needs, or in case of an emergency, press 1 after dialing
1-800-831-6844.)
For Support On This ProductDial 1-800-831-6844, and...
®
RISM
ABI P
ABI P
3700 DNA Analyzer
®
RISM
3100 Genetic Analyzer
PressFAX
8650-638-5891
PressFAX
26650-638-5891
BioInformatics (includes BioLIMS
BioMerge
DNA Synthesis
Fluorescent DNA Sequencing
Fluorescent Fragment Analysis (includes
GeneScan
Integrated Thermal Cyclers
1-6 0.5-mL Sample Block Module
™
, and SQL GT
®
applications)
™
™
applications)
,
PressFAX
25505-982-7690
PressFAX
21650-638-5981
PressFAX
22650-638-5891
PressFAX
23650-638-5891
PressFAX
24650-638-5891
For Support On This ProductDial 1-800-831-6844, and...
PCR and Sequence Detection
PressFAX
5, or call
1-800-762-4001,
and press 1 for
PCR, or 2 for
Sequence
Detection
240-453-4613
FMAT
Peptide and Organic Synthesis
Protein Sequencing
Chemiluminescence
LC/MS
TelephoneFAX
1-800-899-5858,
and press 1, then
press 6
PressFAX
31650-638-5981
PressFAX
32650-638-5981
TelephoneFAX
1-800-542-2369
(U.S. only), or
1-781-271-0045
(Tropix)
TelephoneFAX
1-800-952-4716 650-638-6223
508-383-7855
781-275-8581
(Tropix)
9:00 a.m. to
5:00 p.m. ET
9:00 a.m. to
5:00 p.m. PT
Documents on
Demand
Free 24-hour access to Applied Biosystems technical documents, including MSDSs , is
available by fax or e-mail.
You can access Documents on Demand through the internet or by telephone:
If you want to
order...Then...
through the
internet
by phone from the
United States or
Canada
Use http://www.appliedbiosystems.com/techsupport
You can search for documents to order using keywords.
Up to five documents can be faxed or e-mailed to you by title.
a. Call 1-800-487-6809 from a touch-tone phone. Have your fax
number ready.
b. Press 1 to order an index of available documents and have it faxed
to you. Each document in the index has an ID number. (Use this as
your order number in step “d” below.)
c. Call 1-800-487-6809 from a touch-tone phone a second time.
d. Press 2 to order up to five documents and have them faxed to you.
0.5-mL Sample Block Module 1-7
If you want to
order...Then...
by phone from
outside the United
States and
Canada
a. Dial your international access code, then 1-858-712-0317 from a
touch-tone phone.
Have your complete fax number and country code ready (011
precedes the country code).
b. Press 1 to order an index of available documents and have it faxed
to you. Each document in the index has an ID number. (Use this as
your order number in step “d” below.)
c. Call 1-858-712-0317 from a touch-tone phone a second time.
d. Press 2 to order up to five documents and have them faxed to you.
To Reach Us by
E-Mail
Regional Offices
Sales and Service
Contact technical support by e-mail for help in the following product areas.
For this product areaUse this e-mail address
Chemiluminescenceinfo@appliedbiosystems.com
Genetic Analysisgalab@appliedbiosystems.com
LC/MSapisupport@sciex.com
PCR and Sequence Detectionpcrlab@appliedbiosystems.com
Protein Sequencing, Peptide and DNA
Synthesis
corelab@appliedbiosystems.com
If you are outside the United States and Canada, you should contact your local
Applied Biosystems service representative.
The Americas
United States
Applied Biosystems
850 Lincoln Centre Drive
Foster City, California 94404
PCR System 9700 amplifies nucleic acids using the polymerase
chain reaction (PCR) process. The 0.5-mL Sample Block Module attaches to the top
of the GeneAmp® PCRSystem 9700 Base Module and allows you to perf orm up to 60
reactions.
You can remove the 0.5-mL Sample Block Module and replace it with another sample
block module as needed. Interchangeability lets you change sample well formats as
well as throughput capacity.
IMPORTANTInterchanging sample block modules may require a firmware change. If the
sample block module is placed on a base module running an earlier software version, the
instrument will not operate correctly. To upgrade the base module software, use the 3.5” floppy
disk that is shipped with the 0.5-mL Sample Block Module. For instructions on upgrading the
software, see the GeneAmp
or visit our web site (www.appliedbiosystems.com/techsupport).
0.5-mL Sample
Block Module
System 9700
Base Module
®
PCR System 9700 Base Module User’s Manual (P/N 0993-6247)
Heated cover
Sample block
0.5-mL Sample Block Module 1-11