Appleton V-51™ Incandescent Luminaires Catalog Page

Page 1
V-51™ Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations.
NEC: Class I, Division 2, Groups A, B, C, D
CEC: Class I, Division 2, Groups A, B, C, D Class II, Divisions 1 and 2, Groups E, F, G Class III Enclosure 3R
Applications
• Enclosed and gasketed lighting fi xtures for use in storage areas, tunnels, subways, chemical plants and other areas where moisture, dirt or corrosive atmospheres are a problem.
• Suitable for use in wet locations.
• Standard fi xtures designed for 60 to 300 W medium base incandescent lamps.
• Available in pendant, 45º stanchion, and a variety of ceiling and wall mountings.
Features
• Furnished with connection block for easy wiring.
• Unitized construction reduces installation and maintenance costs.
• Shock-absorbing porcelain socket for longer lamp life.
• Neoprene rubber ring in neck of refl ector snaps into groove of mounting hood – protects against vibration and chipping.
• Guard snaps into two recesses of adapter – no clamps or setscrews.
• Maximum input voltage 150 V.
Standard Materials
• Mounting hoods: malleable iron
• Globe adapters: malleable iron
• Socket: porcelain with brass screw shell
• Globes: glass. Optional globes in polycarbonate plastic 100 W Max
• Guards: steel
Standard Finishes
INCANDESCENT/AREA: NEC/CEC ENCLOSED AND GASKETED
• Malleable iron mounting hood and globe adapter: triple coat – (1) zinc electroplate, (2) chromate, and (3) epoxy powder coat
• Steel guard: zinc electroplate
• Socket and globes: natural fi nish
Options
• To order fi xture with other than standard clear glass globe, add suffi x letters to catalog number as indicated in table, and adjust difference in price.
Color Glass Globe Plastic Globe
Amber -AM -PAM
Blue -BL
Green -GR -PGR
Red -RE -PRE
Clear Heat-Resistant -HR
Illustrated Features
Cut-Away View
Connection block is easily removed (loosen two screws) to permit quick wiring.
Mounting Hood
Available in pendant (shown), ceiling, wall and 45º stanchion. Pendant has setscrew to prevent fixture from turning on stem.
Neoprene Ring
Neoprene attachment ring secures reflector to mounting hood – no tools needed.
Globe Adapter
When adapter is threaded onto mounting hood, the socket makes electrical contact with connection block in mounting hood. Available in malleable iron (VAD-1M and VAD-2M)
Guard
Two sealed ball plunger units snap quickly, easily and securely into cavities of globe adapter. Guard can be used with or without a reflector.
Guard
NEC/CEC Certifications and Compliances
• UL Standard: UL 1598, UL 844
• UL Listed: E10444
• CSA Standard: C22.2 No. 250, C22.2 No. 137
• CSA Certifi ed: 025428
With heat-resistant glass globes or plastic globes. 300 W PS-25 NOT approved for Class II, Division 1 and 2, Group G; Class III.
610
© July 2020
Page 2
V-51™ Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations.
NEC: Class I, Division 2, Groups A, B, C, D
Class I, Division 2, Groups A, B, C, D
Fixture is suitable for Class I, Division 2 where the fixture operating temperature does not exceed the ignition temperature of the atmosphere in which fixture is installed.
“T” Numbers Represent the Maximum Lamp Temperature for Class I, Division 2 Locations
Supply Wire: 257 ºF/125 ºC
“T”
Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp.
351-
326-
301-
Range
Temp.
Range
Class I, Division 2, Groups A, B, C, D
450
(ºC)
664-
(ºF)
Reflector
350
619-
842
662
None T3 T2D T2C 325
325
574-
617
281-
300
538-
572
CEC: Class I, Division 2, Groups A, B, C, D Class II, Divisions 1 and 2, Groups E, F, G Class III Enclosure 3R
261-
231-
216-
230
421-
446
201-
215
394-
419
PS-25 150 W
A-21
100 W
280
502-
536
260
448-
500
60-150 W 200-300 W
181-
200
358-
392
166-
180
331-
356
161-
165
322-
329
PS-30 200 W
136-
160
277-
320
121-
135
250-
275
101-
120
214-
248
86-100 85
187-
212
PS-30 300 W
INCANDESCENT/AREA: NEC/CEC ENCLOSED AND GASKETED
185
Fixture Ambient Suitability: Class I, Division 2, Groups A, B, C, D
Areas ºC ºF Fixture Watts
Non-Classified 75 167 A-23 60 to 300
Classified 40 104 PS-30 60 to 300
Fixture Ambient Suitability: Class II, Groups E, F, G; Class III; Enclosure 4X
With heat-resistant glass globes or plastic globes. 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
© July 2020
611
Page 3
V-51™ Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Fixtures suitable for use in wet locations.
NEC: Class I, Division 2, Groups A, B, C, D
Malleable Mounting Hood,
Adapter
and Guard Type Lamp Watts
Pendant
Ceiling — Five Tapped Openings — Four close-up plugs
INCANDESCENT/AREA: NEC/CEC ENCLOSED AND GASKETED
CEC: Class I, Division 2, Groups A, B, C, D Class II, Divisions 1 and 2, Groups E, F, G Class III Enclosure 3R
A-21 60-150
PS-30 150-300
A-21 60-150
PS-30 150-300
Size
(Inches)
1/2 VA1050G-M
3/4 VA1075G-M
1 VA1100G-M
1-1/4 VA1125G-M
1/2 VA2050G-M
3/4 VA2075G-M
1 VA2100G-M
1-1/4 VA2125G-M
1/2
3/4 VXHA1075G-M
1 VXHA1100G-M
1/2 VXHA2050G-M
3/4 VXHA2075G-M
1 VXHA2100G-M
All Malleable
with Guard
VXHA1050G-M
Wall — JB Box Mounting — Fits JB cast outlet box — Screws and gasket furnished with fixture
A-21 60-150 JBW10G-M
PS-30 150-300 JBW20G-M
Ceiling – JB Box Mounting — Fits JB cast outlet box — Screws and gasket furnished with fixture
A-21 60-150 JB10G-M
PS-30 150-300 JB20G-M
With heat-resistant glass globes or plastic globes. 300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III. To order fixtures without guards, omit -G suffix from catalog number. Order reflectors and accessories separately. 30º angle reflector adaptable for 100 W fixture only, when mounted at least 114.3 mm (4.5”) from wall. JB cast outlet box is available in the Fitting Section.
612
© July 2020
Page 4
V-51™ Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.
NEC: Class I, Division 2, Groups A, B, C, D
Description Hub Size (Inches)
Pendant and Ceiling Mounting Hoods — Furnished with connection block, gasket and screws
CEC: Class I, Division 2, Groups A, B, C, D Class II, Divisions 1 and 2, Groups E, F, G Class III Enclosure 3R
Pendant Mounting
1/2 VA50
3/4 VA75
1 VA100
1-1/4 VA125
Dead-End — Ceiling Mounting
1/2 V50
3/4 V75
Feed-Thru — Ceiling Mounting
1/2 VC50
3/4 VC75
Three Hubs — Ceiling Mounting
1/2 VT50
3/4 VT75
Four Hubs — Ceiling Mounting
1/2 VX50
3/4 VX75
Five Hubs — Ceiling Mounting
1/2 VXHA50
3/4 VXHA75
1 VXHA100
Catalog Numbers
Malleable Iron
INCANDESCENT/AREA: NEC/CEC ENCLOSED AND GASKETED
Wall and Stanchion Mounting Hoods — Furnished with connection block, gasket and screws
One Opening — Wall Mounting — 1 tapped hole in center of flange
1/2 VGA50
3/4 VGA75
Feed-Thru — Wall Mounting — 2 tapped vertical feed-thru hubs
1/2 VD50
3/4 VD75
Three Hubs and One Opening – Wall Mounting — 3 hubs plus 1 tapped opening in center of flange
1/2 VGAT50
3/4 VGAT75
300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III. Four close-up plugs furnished. Mounting hoods for wall installations can only be used with 30º angle reflectors.
© July 2020
613
Page 5
V-51™ Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.
NEC: Class I, Division 2, Groups A, B, C, D
Wall Ceiling Type
Wall and Ceiling Outlet Box Mounting Hoods
CEC: Class I, Division 2, Groups A, B, C, D Class II, Divisions 1 and 2, Groups E, F, G Class III Enclosure 3R
SEH and 3-1/4” or 4” Octagonal Outlet Box Mounting for Non-Classified Areas Only
Wall
Ceiling 0BV1
GS Round Base Outlet Box Mounting – Form 20
Wall
Ceiling GS2
JB Round Base Outlet Box Mounting
Wall
Ceiling JB1
Catalog Numbers
Malleable Iron
0BVW1
GSW2
JBW1
INCANDESCENT/AREA: NEC/CEC ENCLOSED AND GASKETED
Fixture Units
300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III. Cast outlet boxes and gaskets are available in the Fitting Section. Screws, gasket and adapter plate furnished with fixture mounting hood. Octagonal outlet boxes are available in the Commercial Fitting Section. Screws, gasket and adapter plate furnished with fixture mounting hood. Mounting hoods for wall installations can only be used with 30º angle reflectors. Accepts steel wire guard only.
A21 PS30 Type Lamp Watts
Adapter/Socket, Globe and Guard
A21 60-150 VU100M
PS30 150-300 VU200M
Adapter/Socket and Globe
A21 60-150 VU100MLG
PS30 150-300 VU200MLG
Adapter/Socket
A21 60-150
PS30 150-300
Catalog Numbers
Malleable Iron
VAD-1M
VAD-2M
614
© July 2020
Page 6
V-51™ Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.
NEC: Class I, Division 2, Groups A, B, C, D
Glass and Polycarbonate Globes — 60-150 W
60 W-150 W Glass 100 W Polycarbonate
Glass Globes — 150-300W
Steel Wire Guards
CEC: Class I, Division 2, Groups A, B, C, D Class II, Divisions 1 and 2, Groups E, F, G Class III Enclosure 3R
Catalog Numbers
Glass
Type Lamp Watts
Clear VGL-1CL VPG-1CL
Amber VGL-1AM VPG-1AM
Blue VGL-1BL
Green VGL-1GR VPG-1GR
Opal VGL-1OP
Red VGL-1RE VPG-1RE
Clear Heat-Resistant VGL-1HR
Clear VGL-2CL
Amber VGL-2AM
Blue VGL-2BL
Green VGL-2GR
Opal VGL-2OP
Red VGL-2RE
Clear Heat-Resistant VGL-2HR
A21
PS30
60-150 VWG-1
150-300 VWG-2
60-150 W
Polycarbonate
100 W Max. 
INCANDESCENT/AREA: NEC/CEC ENCLOSED AND GASKETED
VWG-1
300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III. Do not use in ambients exceeding +25º C (+77 ºF). For burning in base-up position only. Cannot be used with polycarbonate globes. Fits VAD-1M Adapter Fits VAD-2M Adapter The V-51 series is not UL certified for use with polycarbonate globes.
© July 2020
615
Page 7
V-51™ Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.
NEC: Class I, Division 2, Groups A, B, C, D
Description Type Lamp Watts Catalog Number
Replacement Reflector Attaching Ring — Neoprene
Connection Block
Lamp Socket — Medium Base
Gasket for Lamp Socket and 60-150 W Globe
CEC: Class I, Division 2, Groups A, B, C, D Class II, Divisions 1 and 2, Groups E, F, G Class III Enclosure 3R
VPT-8
VPT-7
VPT-1AV
VPT-2
Gasket for 150-300 W Globe
INCANDESCENT/AREA: NEC/CEC ENCLOSED AND GASKETED
Gasket for Mounting Hood
VPT-3
VPT-4
300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
616
© July 2020
Page 8
V-51™ Incandescent Luminaires
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit.
NEC: Class I, Division 2, Groups A, B, C, D
Dimensions in Millimeters (Inches)
96.8 (3.81)
Type VA Types V, VC, VT and VX Type VXHA Types OBV and OBVW
88.9
114.3 (4.50)
23.9 (0.94)
(3.50)
60.5 (2.38)
CEC: Class I, Division 2, Groups A, B, C, D Class II, Divisions 1 and 2, Groups E, F, G Class III Enclosure 3R
131.8 (5.19)
96.8 (3.81)
55.6 (2.19)
66.8
76.2 (3.00)
(2.63)
19.1 (0.75)
114.3 (4.50)
66.8 (2.63)
101.6 (4.00)
12.7 (3.50)
112.8 (4.44)
101.6 (4.00)
69.9 (2.75)
101.6
(4.00)
127 (5.00)
117.6 (4.63)
12.7 (3.50)
12.7
(3.50)
127 (5.00)
117.6 (4.63)
55.6 (2.19)
77.7 (3.06)
INCANDESCENT/AREA: NEC/CEC ENCLOSED AND GASKETED
Types VGA and VGAT Type VD Types JB and JBW Types GS and GSW
1/2 and 3/4
Size A B C
D
60-150 W 162.1 (6.38) 146.1 (5.75) 106.4 (4.19) 66.8 (2.63) 73.4 (2.89)
150-300 W 241.3 (9.50) 219.2 (8.63) 144.5 (5.69) 66.8 (2.63) 73.4 (2.89)
300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III.
© July 2020
1 and 1-1/4
D
617
Page 9
V-51™ Incandescent Luminaire
Enclosed and Gasketed
UNILETS® for use with threaded metal conduit. Full-size photometric data available for all V-51® fixtures on request.
NEC: Class I, Division 2, Groups A, B, C, D
Photometric Data
Without Reflector
CEC: Class I, Division 2, Groups A, B, C, D Class II, Divisions 1 and 2, Groups E, F, G Class III Enclosure 3R
Effective Floor Cavity Reflectance (Rfc) is 20%
% Ceiling Rcc 80 70 50 30 10 0
% Walls Rw 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
1 .815 .765 .721 .755 .711 .668 .642 .608 .577 .539 .513 .489 .444 .424 .406 .360
2 .690 .619 .558 .639 .575 .521 .542 .492 .449 .452 .414 .380 .370 .341 .315 .273
3 .595 .515 .450 .551 .478 .421 .467 .410 .362 .388 .344 .307 .316 .282 .252 .215
4 .523 .439 .374 .485 .409 .350 .411 .351 .303 .343 .296 .257 .279 .242 .212 .178
5 .457 .376 .313 .426 .350 .292 .362 .300 .254 .302 .253 .215 .246 .208 .177 .147
6 .409 .326 .266 .378 .303 .248 .322 .261 .215 .269 .220 .183 .220 .180 .150 .123
7 .364 .283 .229 .338 .264 .213 .288 .226 .184 .240 .192 .155 .198 .158 .128 .104
8 .329 .251 .197 .305 .234 .185 .260 .202 .160 .220 .171 .136 .179 .141 .112 .090
ROOM CAVITY RATIOS
9 .298 .223 .171 .277 .208 .161 .237 .180 .140 .199 .152 .119 .164 .126 .098 .078
10 .271 .198 .152 .251 .187 .142 .216 .161 .123 .182 .137 .104 .151 .113 .086 .068
INCANDESCENT/AREA: NEC/CEC ENCLOSED AND GASKETED
300 W PS-25 not approved for Class II, Division 1 and 2, Group G; Class III
618
© July 2020
Loading...