Appleton Uninterruptible Power Supplies Data Sheet

Uninterruptible Power Supplies
SLN & SPS Mini-Tower Off-line UPS
The SolaHD SLN & SPS Series provides economical protection from damaging impulses and power interruptions. These units include three outlets for critical devices needing battery back-up and surge protection. The SLN & SPS is ideal for industrial environments as well as point of sale and
Applications
• PCs
• Workstations
• Computer Terminals
E179213
Features
• Lightweight, compact design
• NEMA 5-15R outlets, protected by battery and surges
• USB communications Interface
• Cable included with free software download
• Two year limited warranty
Selection Table
Capacity
(VA/W)
600/360
1000/600
1500/900
Catalog Number
SLN600
SPS850
SLN1000
SLN1500
Certifications and Compliances
• RoHS Compliant
Related Products
• Surge Protective Devices
• Active Tracking
• Portable MCR Power Conditioners
Volts, Frequency
In/Out
120 Vac, 60 Hz
Listed, UPS Equipment
- UL 1778, CSA C22.2 No. 107.3
®
Filters
Typical Back-up Time
(minutes)
3.5
2.5
3
3 5-15P / Five 5-15R
Input Plug/
Output Receptacle
5-15P / Three 5-15R850/510
SLN & SPS Accessories
Catalog Number Description
SLNSPSPMBRK
SLNSPSPMBRK1
Wall/panel mount bracket kit for SLN & SPS (600 VA~850 VA) UPS 1.0 (0.45)
Wall/panel mount bracket kit for SLN (1000 VA~1500 VA) UPS 1.0 (0.45)
Approx. Ship Weight
lbs (kg)
69
Uninterruptible Power Supplies
SLN & SPS Specifications
Catalog Number SLN600 SPS850 SLN1000 SLN1500
Topology
Capacity (VA/W)
Unit (H x W x D) - in. (mm)
Ship Weight - lbs (kg)
Voltage
Frequency
Input Power Cord
Voltage (Battery Mode)
Frequency (On Battery)
Auto Voltage Regulation (AVR function under Normal Mode)
Overload Protection
Short Circuit *
OSCP is Output Short Circuit Protection
V
1. 110%±5% load for
2. 120%±5% load for
3. 130%±5% load for
1. The Output current continues over
2. UPS goes to retry mode every 10
3. The Battery recharges when
4. UPS goes to auto recovery mode
Line Interactive Ofine Line Interactive Line Interactive
600/360 850/510 1000/600 1500/900
Dimensions
5.6x4.1x11.82 (142x104x300.2)
5.6x4.1x11.82
(142x104x300.2)
7.09x5.12x12.6 (180x130x320)
12.13 (5.5) ± 10% 8.16 (3.7) ± 10% 19.62 (8.9) ± 10% 25.35 (11.5) ± 10%
Input Parameters
120 Vac
-23% / +29%
120 Vac
-25% / +20%
120 Vac
-23% / +29%
60 Hz +/- 10%
5 ft. with NEMA 5-15P
Output AC Parameters
120V±10%
60 Hz
V
= Input 102 Vac x 118% at
out
Boost mode
= Input 138 Vac x 85% at Buck
out
mode
Line Mode:
N/A
V
= Input 102 Vac x 118% at Boost mode
out
V
= Input 138 Vac x 85% at Buck mode
out
Line Mode:
1. 110%±5% load for 5 mins. After, the power 5 mins. After, the power will not be provided to the load. Then, ev­ery 10 mins, auto recovery will be attempted.
will not be provided to the load. Then, every 10 mins, auto recovery will be attempted.
2. 120%±5% load for 10 seconds. After, the
power will not be provided to the load. Then,
every 10 mins, auto recovery will be at­10 seconds. After, the power will not be provided to the load. Then, every 10 mins, auto recovery will be attempted.
Breaker Protection
tempted.
3. 130%±5% load for 1.5 seconds. After, the power will not be provided to the load. Then, every 10 mins, auto recovery will be at­tempted.
1.5 seconds. After, the power will not be provided to the load. Then, every 10 mins, auto recovery will be attempted.
125% within 60ms to OSCP* and then goes to Battery MODE.
seconds until the Battery Voltage (VB) <11V/cell.
the VB>12.7V/cell, then UPS continues retry mode every 10 seconds.
1. The Output current continues over 250% within 60ms to OSCP* and then goes to Battery MODE.
2. UPS goes to retry mode every 10 seconds until the Battery Voltage (VB) <11V/ cell.
3. The Battery recharges when the VB>12.7V/cell, then UPS
1. The Output current continues over 125% within 60ms to OSCP* and then goes to Battery MODE.
2. UPS goes to retry mode every 10 seconds until the Battery Voltage (V
3. The Battery recharges when the V cell, then UPS continues retry mode every 10 seconds.
4. UPS goes to auto recovery mode until the short circuit disappears then goes back to LINE Mode.
continues retry mode every until the short circuit disappears then goes back to LINE Mode.
10 seconds.
4. UPS goes to auto recovery mode until the short circuit disappears then goes back to LINE Mode.
7.09x5.12x12.6 (180x130x320)
) <11V/cell.
B
>12.7V/
B
70
Loading...