Unicode™ 2 Series Rotary Actuators
CONTROLS CONTROLS: NEC/CEC, ATEX/IECEX INCREASED SAFETY CONTROL STATIONS
© June 2017
Components for Increased Safety Enclosures
NEC/CEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 1, AEx de IIC
Class I, Zone1, AEx e IIC
NEC/CEC:
Class II, Division 2, Groups F, G
Class III
Type 4X/IP66
Features
• Can be equipped with up to three Unicode 2 Series Contact
Blocks (UCB) contact blocks.
• Globally certied.
• Available in TS35 rail mounted or panel mounted.
Standard Materials
• Body: thermosetting plastic
• Seal: ethylene propylene diene Monomer (M-class) rubber
(EPDM)
NEC/CEC Certifications and Compliances
• Certication Type TCe
— Operating Temperature: -40 °C to +60 °C (-40 °F to +140 °F)
— Ingress Protection (solid and liquid): IP66 and Type 4X
— CAN/CSA Standards: C22.2 No. 0-M91, No. 14-05, No.
94-M91, No. 213-M1987, No. 60079-0:07, No. 60079-1:07,
No. 60529:05, E60079-7-03, E61241-1-1:02
— UL Standards: UL 508, UL 50E, UL 60079-0, UL 60079-1, UL
60079-7
— Other Standards: ANSI/ISA 12.12.01-2011, ANSI/ISA
61241-0 (12.10.02)-2006, ANSI/ISA 61241-1(12.10.03)-2006
— CSA Certicate: 2358701
ATEX/IECEx Certifications and Compliances
• Certication Type TCe
— Gas: Zone 1 and 2
– Conforming to ATEX 94/9/CE: II 2 G
– Type of Protection: Ex e IIC Gb
— Dust: Zone 21 and 22
– Conforming to ATEX 94/9/CE: II2 D
– Type of Protection: Ex tb IIIC Db
• Surface Temperature: -40 °C to +60 °C (-40 °F to +140 °F)
• CE Declaration of Conformity: 5C242
• ATEX Certicate: LCIE 09 ATEX 3010U
• IECEx Certicate: IECEx LCI 09.0011U
• Index of Protection according EN/IEC 60529: IP66
• Impact Resistance (shock): IK10
EURASEC Certification
• EURASEC RU C-FR. ГБ05.B00909
Other Certification
• INMETRO Certicate: BVC 11.0644-U
ATEX/IECEx:
Zone 1 and 2 – 21 and 22
II 2 GD
IP66 – IK10
UH0R
(rail mounted contacts)
UJ0R
(rail mounted contacts)
(panel mounted contacts)
(panel mounted contacts)
UH0P
UJ0P
Dimensions in Millimeters (Inches)
Rail Mounted Contacts Panel Mounted Contacts
Ø 40 mm (1.57”)
(1.04”)
M30 x 1.5 (0.25”)
Ø 40 mm (1.57”
(1.04”)
26.5 mm
(1.36”)
UCB
Contact Block
Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used.
INMETRO certification available on special request only. Contact your local sales representative for more information.
212
Unicode™ 2 Series Rotary Actuators
CONTROLSCONTROLS: NEC/CEC, ATEX/IECEX INCREASED SAFETY CONTROL STATIONS
© June 2017
Components for Increased Safety Enclosures
NEC/CEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 1, AEx de IIC
Class I, Zone1, AEx e IIC
Rail Mounted Panel Mounted Rail Mounted Panel Mounted Pack Rail Mounted Panel Mounted
2-Position Rotary Actuator (contact block to be ordered separately)
For legend plates, guards and blanking plugs see accessories page.
2-Positions Selector
Switch (O-I), 2 maintained
positions
3-Position Rotary Actuator (contact block to be ordered separately)
Legend plates, guards, blanking plugs (see Accessories page).
3-Position Selector Switch,
I and II position maintained
(I-O-II)
3-Position Selector Switch,
I and II spring return to O
(I->O<-II)
3-Position Selector Switch,
I maintained, II spring return
to O (I-O<-II)
3-Position Selector Switch,
I spring return to O, II
maintained (I->O-II)
1-Pole Contact Blocks
1 x NO
1 x NC
Spare Parts
Rail to panel mounted
conversion adaptor
0.038 (0.084) 0.051 (0.112) 0.09 (5.49) 0.22 (13.43) 1
0.038 (0.084) 0.051 (0.112) 0.09 (5.49) 0.22 (13.43) 1
0.038 (0.084) 0.051 (0.112) 0.09 (5.49) 0.22 (13.43) 1 UK0R UK0P
0.038 (0.084) 0.051 (0.112) 0.09 (5.49) 0.22 (13.43) 1 UM0R UM0P
0.038 (0.084) 0.051 (0.112) 0.09 (5.49) 0.22 (13.43) 1
NEC/CEC:
Class II, Division 2, Groups F, G
Class III
Type 4X/IP66
Weight kg (lb) Volume dm3 (in3)
0.032 (0.071) 0.06 (3.66) 1
0.02 (0.04) 0.08 (4.88) 1
ATEX/IECEx:
Zone 1 and 2 – 21 and 22
II 2 GD
IP66 – IK10
Catalog Number
UH0R UH0P
UJ0R UJ0P
UN0R UN0P
UCB5R UCB5P
UCB9R UCB9P
— UPMA
Wiring Diagrams
UJ0 UK0
UM0 UN0
Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used.
213