Unicode™ 2 Series Mushroom Push Buttons
Ø 40.5 mm (1.59”)
M30 x 1.5 (0.25”)
CONTROLS CONTROLS: NEC/CEC, ATEX/IECEX INCREASED SAFETY CONTROL STATIONS
© June 2017
Components for Increased Safety Enclosures
NEC/CEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 1, AEx de IIC
Class I, Zone1, AEx e IIC
NEC/CEC:
Class II, Division 2, Groups F, G
Class III
Type 4X/IP66
Features
• Can be equipped with up to three Unicode 2 Series Contact
Blocks (UCB) contact blocks.
• Globally certied.
• Available in TS35 rail mounted or panel mounted.
Standard Materials
• Body: polyamide
• Seal: ethylene propylene diene Monomer (M-class) rubber
(EPDM)
NEC/CEC Certifications and Compliances
• Certication Type TCe
— Operating Temperature: -40 °C to +60 °C (-40 °F to +140 °F)
— Ingress Protection (solid and liquid): IP66 and Type 4X
— CAN/CSA Standards: C22.2 No. 0-M91, No. 14-05, No.
94-M91, No. 213-M1987, No. 60079-0:07, No. 60079-1:07,
No. 60529:05, E60079-7-03, E61241-1-1:02
— UL Standards: UL 508, UL 50E, UL 60079-0, UL 60079-1,
UL 60079-7
— Other Standards: ANSI/ISA 12.12.01-2011, ANSI/ISA 61241-0
(12.10.02)-2006, ANSI/ISA 61241-1(12.10.03)-2006
— CSA Certicate: 2358701
ATEX/IECEx Certifications and Compliances
• Certication Type TCe
— Gas: Zone 1 and 2
– Conforming to ATEX 94/9/CE: II 2 G
– Type of Protection: Ex e IIC Gb
— Dust: Zone 21 and 22
– Conforming to ATEX 94/9/CE: II2 D
– Type of Protection: Ex tb IIIC Db
• Surface Temperature: -40 °C to +60 °C (-40 °F to +140 °F)
• CE Declaration of Conformity: 5C242
• ATEX Certicate: LCIE 09 ATEX 3010U
• IECEx Certicate: IECEx LCI 09.0011U
• Index of Protection according EN/IEC 60529: IP66
• Impact Resistance (shock): IK10
EURASEC Certification
• EURASEC RU C-FR. ГБ05.B00909
Other Certification
• INMETRO Certicate: BVC 10.0044-U
ATEX/IECEx:
Zone 1 and 2 – 21 and 22
II 2 GD
IP66 – IK10
UR0R
(rail mounted contacts)
UD0R
(rail mounted contacts)
(panel mounted contacts)
(panel mounted contacts)
UR0P
UD0P
Dimensions in Millimeters (Inches)
Rail Mounted Contacts Panel Mounted Contacts
(1.56”)
39.5 mm
58.5 mm (2.30”)
Contact Block
Ø 40.5 mm (1.59”
(1.56”)
39.5 mm
(1.36”)
UCB
Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used.
INMETRO certification available on special request only. Contact your local sales representative for more information.
206
Unicode™ 2 Series Mushroom Push Buttons
CONTROLSCONTROLS: NEC/CEC, ATEX/IECEX INCREASED SAFETY CONTROL STATIONS
© June 2017
Components for Increased Safety Enclosures
NEC/CEC:
Class I, Division 2, Groups A, B, C, D
Class I, Zone 1, AEx de IIC
Class I, Zone1, AEx e IIC
Weight kg (lb) Volume dm3 (in3)
Rail Mounted Panel Mounted Rail Mounted Panel Mounted Pack Rail Mounted Panel Mounted
Spring Return Mushroom Head Push Button (contact block to be ordered separately)
Legend plates, guards, blanking plugs (see Accessories page).
Red 0.045 (0.099) 0.06 (0.13) 0.26 (15.87) 0.12 (7.32) 1 UR0R UR0P
Black 0.045 (0.099) 0.06 (0.13) 0.26 (15.87) 0.12 (7.32) 1 UB0R UB0P
Push-Pull Mushroom Head Push Button (contact block to be ordered separately)
Legend plates, guards, blanking plugs (see Accessories page).
Red Emergency Stop 0.045 (0.099) 0.06 (0.13) 0.12 (7.32) 0.26 (15.87) 1 UD0R UD0P
1-Pole Contact Blocks
1 x NO
0.032 (0.071) 0.06 (3.66) 1
1 x NC UCB9R UCB9P
Accessories
Rail to panel mounted
conversion adaptor
0.02 (0.04) 0.08 (4.88) 1 UPMA
NEC/CEC:
Class II, Division 2, Groups F, G
Class III
Type 4X/IP66
ATEX/IECEx:
Zone 1 and 2 – 21 and 22
II 2 GD
IP66 – IK10
Catalog Number
UCB5R UCB5P
Overall hazardous location and ingress protection rating depends on the rating of the optional certified components used.
207