Appleton Ground Fault Circuit Interrupters Catalog Page

2.00
11.00
McGill™ Ground Fault Circuit Interrupters
REELS AND SWITCHES: ORDINARY LOCATION POWERCORDS
© February 2017
NEC/CEC:
Listed for Ordinary Locations
Applications
• Protects people and equipment by interrupting electrical power when loads have a potentially lethal ground current in excess of 6 milliamps.
• The portable construction enables use of these devices in a variety of applications, such as power tools or hand lamps.
• Indoor/Outdoor usage.
Features
• 15 and 20 Amp, 120 and 240 Volt, 60 Hz models available.
• 4-6 milliamp trip level.
• Provides protection in 3 wire circuits.
• Mechanical trip indicator to show power “ON”.
• Rugged construction for long lasting durability.
• Grounded neutral — 4 ohms typical.
• Open neutral protection.
• Radio frequency interference suppression to protect against nuisance tripping.
NEC/CEC Certifications and Compliances
• UL Listed: E165783
• CSA Approved
5002-0518 5002-0511 5002-0512 5002-0510
5002-0520
5002-0528
NEMA Configuration
Number Rating
Catalog Number
GFCI cord set, 274 mm (11”) long 5-15P/R 15 Amp, 120 Vac 5002-0510
User attachable GFCI portable power plug 5-15P 15 Amp, 120 Vac 5002-0511
User attachable in-line GFCI, dual voltage 15 - 20 Amp, 120 - 240 Vac 5002-0512
GFCI cord set, 1.83 m (6’) long with tri-tap receptacle 5-15P/R 15 Amp, 120 Vac 5002-0518
GFCI protected quad box
5-20P/R 20 Amp, 120Vac 5002-0519
In-line GFCI with plug and receptacle attached 5-15P/R 15 Amp, 120 Vac 5002-0520
In-Line GFCI with plug and tri-tap molded power block attached 5-15P/R 15 Amp, 120 Vac 5002-0528
Dimensions in Inches/Millimeters
4.00
2.00
5002-0510
5002-0511
5002-0518
5002-0519
5002-0528 5002-0512 5002-0520
2 of the 4 receptacles are T-slotted to allow both 15 and 20 amp tools, with either NEMA 5-15 or 5-20 plugs.
585