CODE•MASTER™ LED FACTORY SEALED LUMINAIRES
FEATURES
• Fixture operates safely in high ambient
temperatures -40°C up to +65°C
(-40°F up to +149°F)
• 60,000+ hours rated life eliminates the need
for frequent relamping
Nominal
Lumens
3,700 100W CMLED10
5,400 150W CMLED15
7,900 175W CMLED17
10,000 250W CMLED25
11,600 350W CMLED35
13,600 400W CMLED40
16,700 600W CMLED75
19,300 750W CMLED90
• Arrangement of heat-producing components
results in more efcient heat dissipation for
cooler xture operation.
• All threaded joints are ame-tight.
• Fixture housing and mounting hoods are
copperfree cast aluminum with baked epoxy
nish. All exposed hardware is stainless steel.
• Aluminum body utilizes the same
Code•Master HID mounting hoods, and is
an easy retrot for existing Code•Master HID
installations; can be pendant, ceiling, wall, or
stanchion mounted.
• Acme double-lead threads speed installation
and xture removal from mounting
hood – only half as many turns are required
as for single-lead threads. The threads do not
stick or gall, eliminating the troublesome
problems often encountered with single lead
threads during xture unit removal.
• Safe, easy servicing without disconnecting
any wiring. “Wireless” xture unit easily
threads off mounting hood for convenient
servicing or for immediate replacement with
a “stand-by” unit.
• Factory sealed. External seals not required.
For Group B applications a Group B rated mounting hood must be used.
HID
Equivalent
Model
Number
• Globe and driver are all eld replaceable.
• LED arrays generate light outputs from
3,700 to 19,000+ lumens (an equivalent of
100 W HID to 750 W HID lamps) providing
exceptional efcacy
• Choice of replaceable clear or diffused glass
globe.
• Universal, high efciency, drivers cover voltage
requirements for 120-277 Vac 50/60 Hz,
125-300 Vdc and 347-480 Vac, 50/60 Hz,
Volts +/- 10%.
• 6KV standard surge suppression for 347-480
Vac and 120-277 Vac input
• Photometric data and electronic drawings
available upon request.
SUITABLE LOCATIONS
• Explosionproof xtures suitable for use in:
— A wide range of hazardous areas where
— Areas where access to relamp is difcult,
— Areas requiring frequent on-and-off of lights
— Type 4X, marine, wet locations and hose-
— Areas with high energy costs- Code•Master
• Typical applications include:
— Chemical
— Oil, Gas, and Petrochemical
— Pulp and Paper
— Foundries
— Manufacturing
— Waste and sewage treatment
— Pharmaceutical
— Mining
— Power Generation
ignitable vapors, dust, moisture and
corrosive elements are present
reliability is essential, and environment is
costly to maintain. Consistent light levels
maintained regardless of cold temperatures
or power cycling- no warm up time required
down environments
LED consumes 50% less power than its HID
equivalent
STANDARD MATERIALS
• Mounting hoods and bodies: cast copperfree
(4/10 of 1% max.) aluminum
• All hardware and catch assemblies: stainless
steel
• Gaskets: silicone
• Globe: explosionproof glass in clear
or diffused
STANDARD FINISHES
• Mounting hoods, bodies, and guards: baked
gray epoxy clad nish, electrostatically applied
for complete uniform protection
NEC/CEC RATINGS
• Class I, Division 1 and 2, Groups B, C, D
• Class I, Zone 1, Groups IIA, IIB, IIB + H2
• Class II, Division 1, Group E, F, G
• Class II, Division 2, Group F, G
• Class III
• Simultaneous Exposure
• Type 3R, 4X
• IP66/67
• Suitable for Use in Wet Locations
• Marine Outside Type (Salt Water)
NEC/CEC CERTIFICATIONS AND COMPLIANCES
• UL Standard: UL 50, UL 50E, UL 844, UL 1598,
UL 1598A, UL 8750
• CSA Standard: CAN/CSA-C22.2 No. 94.1-07
(R2012), No. 94.2-07 (R2012), No. 137M1981 (R2009), No. 250.0-08 (R2013), No.
250.13, No. 60529-05 (R2010)
• ANSI Standard: ANSI/IEC 60529
• cCSAus Certied: 70030675

The Appleton and Emerson logos are registered in the U.S. Patent and Trademark Ofce.
All other product or service names are the property of their registered owners. © 2019, Appleton Grp LLC. All rights reserved.
Efcient heat dissipation for optimum T
rating and safe operation in high and low
ambient temperatures
CODE•MASTER LED FACTORY SEALED LUMINAIRES
Delivering up to 132 lumens per Watt,
easily accessed with removal of the
threaded globe assembly
NEMA 4x cast copperfree aluminum body
with baked epoxy powder coat nish for
durability and corrosion resistance
Choice of clear glass lens or diffused lens to
reduce glare in low ceiling applications
Optional lens guard to protect against
breakage
CMLED10 CMLED15 CMLED17 CMLED25 CMLED35 CMLED40 CMLED75 CMLED90
Field replaceable driver
to quickly maintain
your luminaire with
minimal downtime
Optional fuse to
protect circuits
against power quality
problems
Equivalent to HPS/PSMH 100 Watt 150 Watt 175 Watt 250 Watt 350 Watt 400 Watt 600 Watt 750 Watt
Voltage
Range
BU 120-277 Vac, 50/60 Hz N/A 120-277 Vac, 50/60 Hz or 125 – 300 Vdc
BH 347-480 Vac, 50/60 Hz
LED Lumens (Clear Globe) 3,700 5,400 7,900 10,000 11,600 13,600 16,700 19,300
Input Power (W) @ 120 Vac 30 45 60 76 91 103 132 157
Efficacy (NEMA Type V,
5000K @ +40°C/F)
123 120 132 130 128 131 126 123
T-Rating T6 T5
Ambient Temperature -40°C up to +65°C (-40°F up to +149°F)
-40°C up to +50°C
(-40°F up to +122°F)
-40°C up to +65°C
(-40°F up to +149°F)
-40°C up to +55°C
(-40°F up to +131°F)
CCT/CRI 3000K, 4000K, 5000K/80
Fixture Weight 17 kg (38 lbs)
Standard Materials Baked gray epoxy clad finish, electrostatically applied for complete, uniform protection
Lifetime 60,000+ hours
`
Product Ordering Guide
CMLED A 17 5 N G 5 BU C
Series:
CMLED -
Code•Master
LED
Mounting:
A - Pendant
C - Ceiling
S - 25°
Stanchion
W - Wall
Blank - No
Mounting
Hood
Lumen
Output
(Nominal):
10 - 3,700
15 - 5,400
17 - 7,900
25 - 10,000
35 - 11,600
40 - 13600
Hub Size:
2 - 3/4” NPT
3 - 1” NPT
4 - 1-1/4” NPT
5 - 1-1/2” NPT
Blank - No hub
75 - 16700
90 - 19300
Example: CMLEDA175G5BUC
Use of a fuse voids Marine Outside Type (Salt Water) rating.
stanchion
stanchion
size needed if
no mounting
hood
Color
Temperature
(CCT):
Blank - Cool,
5000K
N - Neutral,
4000K
W - Warm,
3000K
Optical
Assembly:
G - Clear
Glass Globe
D - Diffused
Glass Globe
Light
Distribution
Pattern:
5 - NEMA Type V
Symmetrical
W - NEMA Type
V Wide
Voltage:
BU - Universal
Voltages
120-277
Vac, 50/60
Hz, or
125-300
Vdc
BH - 347-480
Vac, 50/60
Hz
Options:
C- Safety Cable
F - Fusing
G- Lens Guard
Blank -No
Options