Code•Master™ Jr. LED Factory Sealed Luminaires
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Applications
• For use in chemical and petrochemical plants, such as
manufacturers of plastics, paints and thinners, in reneries,
and in other areas where ignitable vapors, dust, moisture and
corrosive elements may be present.
• Suitable for outdoor saltwater locations and for other
wet locations.
Features
• Fixtures operate safely in high ambient temperatures:
-40°C to +55°C (-40°F to +131°F) for CJLL1 and CJLL2;
-40°C to +40°C (-40°F to +104°F) for CJLL3.
Nominal Lumens
1,600 100W 50W CJLL1
3,000 300W 70-100W CJLL2
5,150 — 100-150W CJLL3
• Acme double-lead threads speed installation of xture into the
mounting hood to make electrical connection.
• The only wiring required is attaching two wires to connection
block in mounting hood. Also allows safe, easy servicing without
disconnecting any wires.
• Heat- and impact-resistant globes have smooth
dust-resistant exterior.
• Optional guards protect globes from damage. Secured to xture
with three stainless steel screws.
• Choice of mountings: pendant, ceiling, bracket and stanchion.
• Fiberglass-reinforced polyester reectors, in standard dome
or 30° angle styles, are ideal in installations where luminaire is
subject to exceptionally severe corrosive atmospheres.
• All threaded joints are ame-tight.
• Universal, high efcient drivers cover voltage requirements for
120-277 Vac 50/60 Hz, 100 – 300 Vdc for CJLL1 and CJLL2;
120-277 Vac 50/60 Hz, 125 – 300 Vdc for CJLL3; 347-480 Vac
50/60 Hz for CJLL3.
Incandescent
Equivalent HID Equivalent Model Number
Options
• Aluminum guard available, purchase separately
Standard Materials
• Fixture housing, mounting hoods and guards: copperfree
(4/10 of 1% max.) aluminum
• Globes: prismatic glass
• Reectors: berglass reinforced polyester
Standard Finishes
• Fixture housing, guards and mounting hoods: epoxy power
coat nish, electrostatically applied for complete, uniform
corrosion protection
NEC/CEC Certifications and Compliances
• UL Standard: UL1598 (4th Ed.), UL1598A (1st Ed.),
UL8750 (2nd Ed.), UL844 (13th Ed.)
• CSA Standard: CSA C22.2 No. 250.0-08, CSA C22.2
No. 137-18, CSA C22.2 No. 60079-0, and
CSA C22.2 No 60079-1
• UL Listed: E10444
Related Products
• Code Master LED
• Code Master Incandescent
• A-51™ LED
For Group B applications, a Group B rated mounting hood must be used.
1
Code•Master™ Jr. LED Factory Sealed Luminaires
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
Pendant
One Hub
3/4” NPT
CAP75
CAP75B
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Ceiling
Four Hubs
Three Close-Up Plugs
3/4” NPT
CAC75
CAC75B
Bracket
Four Hubs
Three Close-Up Plugs
3/4” NPT
CALB75
CALB75B
Code•Master
Jr. LED Fixture Unit
CJLL
25° Stanchion
One Hub
1-1/4 or 1-1/2” NPT
CAS150
CAS150B
Optional
Standard Dome
KR2-ST
Optional Aluminum
For Group B applications, a Group B rated mounting hood must be used.
Guard
CJGU-15
Optional Three Way
Exit Sign
CJEXRN
(not UL Listed)
Optional
Angle Reflector
KR2-AN
2
Code•Master™ Jr. LED Factory Sealed Luminaires
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
Order using catalog numbering guides below or select catalog number from tables on following pages.
CJL A L1 2 C BU G
Series:
CJL – Code•Master
Jr. LED
Mounting Hood:
A – Pendant
W – Wall Bracket
C – Ceiling
S – 25° Stanchion
Blank – No Mounting
Hood
NEC/CEC Temperature Codes
Model
CJLL1 90 (194)
CJLL2 90 (194)
Use Wire Supply
° C (° F)
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Lumen
Output
(nominal):
L1 – 1600
L2 - 3000
L3 - 5150
2 - 3/4” NPT
3 - 1” NPT
4 - 1-1/4” or 1-1/2” NPT
Blank - No hub size needed if
Hub Size:
stanchion
no mounting hood
Ambient Temperature
° C (° F)
40 (104)
55 (131)
40 (104)
55 (131)
Color
Temperature:
C - Cool, 5000K
W - Warm, 3000K
BU - 120-277 Vac,
BH - 347-480 Vac,
Class I, Division 1,
Groups B, C and D
T6 T6
T6 T6
Options:
G – Guard
Blank – No Guard
Voltage:
50/60Hz; or
100-300 Vdc
50/60Hz
Class II, Division 1,
Groups E, F and G
CJLL3 90 (194) 40 (104)
“T” Numbers Represent the Maximum External Temperature for Class I, Division 1 Locations and
Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations.
“T”
Number
Temp
Range
(°C)
Temp
Range
(°F)
NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National
For Group B applications, a Group B rated mounting hood must be used.
Only for L1 and L2 models, 125–300 Vdc for L3 model.
Only for L3 models.
T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3 T4 T4A T5 T6
351-
326-
301-
281-
261-
231-
216-
201-
181-
450
350
325
300
280
664-
619-
574-
538-
842
662
617
Electrical Code and the Canadian Electrical Code.
572
502-
536
260
448-
500
230
421-
446
215
394-
419
200
358-
392
166-
180
331-
356
T6 T6
161-
136-
121-
165
322-
329
160
277-
320
135
250-
275
101-
120
214-
248
86-
100
187-
212
85
185
3
Code•Master™ Jr. LED Factory Sealed Luminaires
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
Electrical Specifications (are within +/-10%)
Model
Number Voltage
120 Vac 13 0.11 >.9 <20%
277 Vac 14 0.05 >.9 <20%
CJLL1
100 Vdc 13 0.13 N/A <20%
300 Vdc 14 0.05 N/A <20%
120 Vac 26 0.22 >.9 <20%
277 Vac 27 0.10 >.9 <20%
CJLL2
100 Vdc 26 0.26 N/A <20%
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Input Power
(Watts)
Input Current
(Amps)
Power Factor
(PF)
Total Harmonic
Distortion (THD)
CJLL3
300 Vdc 27 0.09 N/A <20%
120 Vac 48 0.40 >.9 <20%
277 Vac 47 0.18 >.9 <20%
125 Vdc 48 0.38 N/A <20%
300 Vdc 47 0.16 N/A <20%
347 Vdc 49 0.15 >.9 <20%
480 Vdc 49 0.11 >.9 <20%
For Group B applications, a Group B rated mounting hood must be used.
4
Code•Master™ Jr. LED Factory Sealed Luminaires
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
Catalog Number
Pendant
Mounting
Type
One Hub
Rigid Conduit
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Hub Size
(inches)
3/4
1
Lumen
Output
1600
3000 CJLAL22CBU
5150
1500
2900 CJLAL22WBU
5100
1600
3000 CJLAL23CBU
5150
1500
2900 CJLAL23WBU
5100
Color Temperature
(CCT) Voltage
5000K
3000K
5000K
3000K
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz;
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz;
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz;
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz;
Catalog
Number
CJLAL12CBU
CJLAL32CBU
CJLAL32CBH
CJLAL12WBU
CJLAL32WBU
CJLAL32WBH
CJLAL13CBU
CJLAL33CBU
CJLAL33CBH
CJLAL13WBU
CJLAL33WBU
CJLAL33WBH
For Group B applications, a Group B rated mounting hood must be used.
5
Code•Master™ Jr. LED Factory Sealed Luminaires
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
Catalog Number
Ceiling
Mounting
Type
Four Hubs
Three Close-Up
Plugs Rigid
Conduit
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Hub Size
(inches)
3/4
1
Lumen
Output
1600
3000 CJLCL22CBU
5150
1500
2900 CJLCL22WBU
5100
1600
3000 CJLCL23CBU
5150
1500
2900 CJLCL23WBU
5150
Color Temperature
(CCT) Voltage
5000K
3000K
5000K
3000K
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz
Catalog
Number
CJLCL12CBU
CJLCL32CBU
CJLCL32CBH
CJLCL12WBU
CJLCL32WBU
CJLCL32WBH
CJLCL13CBU
CJLCL33CBU
CJLCL33CBH
CJLCL13WBU
CJLCL33WBU
CJLCL33WBH
For Group B applications, a Group B rated mounting hood must be used.
6
Code•Master™ Jr. LED Factory Sealed Luminaires
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
Catalog Number
Bracket
Mounting
Type
Four Hubs
Three Close-Up
Plugs Rigid
Conduit
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Hub Size
(inches)
3/4
1
Lumen
Output
1600
3000 CJLWL22CBU
5150
1500
2900 CJLWL22WBU
5100
1600
3000 CJLWL23CBU
5150
1500
2900 CJLWL23WBU
5100
Color Temperature
(CCT) Voltage
5000K
3000K
5000K
3000K
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz
Catalog
Number
CJLWL12CBU
CJLWL32CBU
CJLWL32CBH
CJLWL12WBU
CJLWL32WBU
CJLWL32WBH
CJLWL13CBU
CJLWL33CBU
CJLWL33CBH
CJLWL13WBU
CJLWL33WBU
CJLWL33WBH
For Group B applications, a Group B rated mounting hood must be used.
7
Code•Master™ Jr. LED Factory Sealed Luminaires
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
Catalog Number
25° Stanchion
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Mounting
Type
One Hub 1-1/4 or 1-1/2
Hub Size
(inches)
Lumen
Output
1600
3000 CJLSL24CBU
5150
1500
2900 CJLSL24WBU
5100
Color Temperature
(CCT) Voltage
5000K
3000K
120-277 Vac
50/60 Hz;
100-300 Vdc-
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz
120-277 Vac
50/60 Hz;
100-300 Vdc
120-277 Vac
50/60 Hz;
125-300 Vdc
347-480 Vac
50/60 Hz
Catalog
Number
CJLSL14CBU
CJLSL34CBU
CJLSL34CBH
CJLSL14WBU
CJLSL34WBU
CJLSL34WBH
For Group B applications, a Group B rated mounting hood must be used.
8
Code•Master™ Jr. LED Factory Sealed Luminaires
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
Fixture Housing (Not including mounting hoods)
1600 Lumens, 5000K, 120-277 Vac and 100-300 Vdc 5.2 (11.5) CJLL1CBU
3000 Lumens, 5000K, 120-277 Vac and 125-300 Vdc 5.2 (11.5) CJLL2CBU
5150 Lumens, 5000K, 120-277 Vac and 100-300 Vdc 5.5 (12.0) CJLL3CBU
5150 Lumens, 5000K, 120-277 Vac and 100-300 Vdc 5.5 (12.0) CJLL3CBH
1500 Lumens, 3000K, 120-277 Vac and 125-300 Vdc 5.2 (11.5) CJLL1WBU
2900 Lumens, 3000K, 120-277 Vac and 100-300 Vdc 5.2 (11.5) CJLL2WBU
5100 Lumens, 3000K, 120-277 Vac and 125-300 Vdc 5.5 (12.0) CJLL3WBU
5100 Lumens, 3000K, 120-277 Vac and 125-300 Vdc 5.5 (12.0) CJLL3WBH
Mounting Hoods
Type Mounting Hub Size (Inches)
Pendant
One Hub
Rigid Conduit
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Description Weight kg (lb) Catalog Number
Certified for Class I,
Division 1 and 2, Groups
C, D
3/4
B, C, D CAP-75B
C, D
1
B, C, D CAP-100B
Hood Weight kg (lb) Catalog Number
0.9 (1.98)
0.9 (1.98)
CAP-75
CAP-100
Ceiling
Four Hubs
Three Close-Up Plugs
Rigid Conduit
Bracket
Four Hubs
Three Close-Up Plugs
Rigid Conduit
25° Stanchion
One Hub 1-1/4 or 1-1/2
For Group B applications, a Group B rated mounting hood must be used.
1-1/2” Tapped hub furnished with 1-1/2” to 1-1/4” reducer.
3/4
1
3/4
1
C, D
1.8 (3.97)
B, C, D CAC-75B
C, D
1.8 (3.97)
B, C, D CAC-100B
C, D
2.7 (5.95)
B, C, D CALB-75B
C, D
2.7 (5.95)
B, C, D CALB-100B
C, D
0.9 (1.98)
B, C, D CAS-150B
CAC-75
CAC-100
CALB-75
CALB-100
CAS-150
9
Code•Master™ Jr. LED Factory Sealed Luminaires
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
Accessories and Replacement Parts
Optional White Polyester Reector
Optional White Polyester Reector
Optional Aluminum Guard
Optional Three Way Exit Sign (not UL Listed)
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Description Weight kg (lb) Catalog Number
Standard Dome 1.1 (2.43) KR2-ST
Angled Reector 1.1 (2.43) KR2-AN
0.2 (0.44) CJGU-15
Replacement Connection Block for Mounting Hoods
3.4 (7.50) CJEXRN
0.2 (0.44) VPT-7
For Group B applications, a Group B rated mounting hood must be used.
10
Code•Master™ Jr. LED Factory Sealed Luminaires
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
Dimensions in Millimeters (Inches)
101.6
(4.00)
Pendant
114.3
(4.50)
198.1
(7.80)
101.6
(4.00)
150.4
(5.92)
114.3
(4.50)
343.7
(13.53)
Hub for .75"
NPT Conduit
334.0
(13.15)
95.3
(3.75)
339.9
(13.38)
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
125.0
(4.92)
99.6
(3.92)
Ceiling
151.3
(5.95)
101.6
(4.00)
330.2
(13.00)
198.1
(7.80)
Wall Bracket
10.4
(0.41)
Hub for .75" NPT
Conduit Four Sides
62.5
(2.46)
31.2
(1.23)
87.9
(3.46)
57.9
(2.28)
Hub For
3/4” NPT
2” Wiring access
cover both sides.
292.1
(11.50)
349.3
(13.75)
125.0
(4.92)
45.5
(1.79)
352.6
(13.88)
314.5
(12.38)
349.3
108.0
(4.25)
198.1
(7.80)
(13.75)
25° Stanchion
25˚
303.0
(11.93)
326.9
(12.87)
290.3
(11.43)
317.0
(12.48)
For Group B applications, a Group B rated mounting hood must be used.
11
Code•Master™ Jr. LED Factory Sealed Luminaires
Distance in units of mounting height (10ft)
Distance in units of mounting height (10ft)
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Photometric Data — DATA SHOWN IS ABSOLUTE
Prismatic Glass, 5000K CCT Polar Candela Distribution Isoillumination Plot
REPORT NUMBER: CJLAL12CBU
Luminaire Lumens 1,600
Zone Lumens % Luminaire
0-30
0-40
0-60
60-90
70-100
90-120
0-90
90-180
0-180
Zone Lumens % Total Zone Lumens % Total
0-10 25.1 1.5% 90-100 109.8 6.8%
10-20 61.3 3.8% 100-110 81.6 5%
20-30 114.6 7.0% 110-120 25.6 1.6%
30-40
40-50
50-60
60-70
70-80
80-90
ZONAL LUMEN SUMMARY
1405.5 86.4%
1626.9 100%
LUMENS PER ZONE
202.5 12.4%
220.7 13.6%
228.4 14.0%
222.7 13.7%
190.0 11.7%
140.1 8.6
201.0 12.4%
403.5 24.8%
852.6 52.4%
552.9 34%
440.0 27%
217.0 13.3%
221.4 13.6%
120-130 2.2 0.1%
130-140 1.5 0.1%
140-150 0.6 0%
150-160 0.1 0%
160-170 0 0%
170-180 0 0%
180° 170° 160° 150° 140°
350
292
233
175
117
58
0
58
117
175
233
292
350
- Max CD - 45° H
- 0° H
- 90° H
3
4
5
20 fc
10 fc
5 fc
2.5 fc
2
6
130°
120°
110°
100°
90°
80°
70°
60°
50°
40° 30° 20° 10° 0°
5
4
3
2
1
2
3
4
5
6
1 fc
0.5 fc
0.2 fc
0.1 fc
2
11100
3
4
5
50% Max Cd
Max Cd
Prismatic Glass, 5000K CCT Polar Candela Distribution Isoillumination Plot
REPORT NUMBER: CJLAL22CBU
Luminaire Lumens 3,000
Zone Lumens % Luminaire
0-30
0-40
0-60
60-90
70-100
90-120
0-90
90-180
0-180
Zone Lumens % Total Zone Lumens % Total
0-10 47.7 1.6% 90-100 209.5 7%
10-20 115.2 3.8% 100-110 157.4 5.2%
20-30 209.9 7.0% 110-120 51.8 1.7%
30-40
40-50
50-60
60-70
70-80
80-90
For Group B applications, a Group B rated mounting hood must be used.
ZONAL LUMEN SUMMARY
1550.7 51.7%
1022.5 34.1%
2573.2 85.7%
3001.0 100%
LUMENS PER ZONE
364.4 12.1%
398.9 13.3%
414.6 13.8%
407.3 13.6%
352.3 11.7%
262.9 8.8%
372.8 12.4%
737.2 24.6%
824.7 27.5%
418.7 14%
427.8 14.3%
120-130 4.7 0.2%
130-140 3.1 0.1%
140-150 1.1 0%
150-160
160-170
170-180
0.2 0%
0 0%
0 0%
180° 170° 160° 150° 140°
620
517
413
310
207
103
0
103
207
310
413
517
620
- Max CD - 45° H
- 0° H
- 90° H
2
3
4
5
6
130°
120°
110°
100°
90°
80°
70°
60°
50°
40° 30° 20° 10° 0°
5
4
3
2
1
2
3
4
5
6
20 fc
10 fc
5 fc
2.5 fc
1 fc
0.5 fc
0.2 fc
0.1 fc
2
11100
3
4
5
50% Max Cd
Max Cd
12
Code•Master™ Jr. LED Factory Sealed Luminaires
Distance in units of mounting height (10ft)
LED/AREA: NEC/CEC EXPLOSIONPROOF
© April 2019
Explosionproof, Dust-Ignitionproof
For use with threaded metal conduit.
NEC/CEC:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class III
Zone 1, Ex db IIB + H2
NEMA 3R, 4X
NEC/CEC:
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)
Photometric Data — DATA SHOWN IS ABSOLUTE
Prismatic Glass, 5000K CCT Polar Candela Distribution Isoillumination Plot
REPORT NUMBER: CJLAL32CBU
Luminaire Lumens 5,150
Zone Lumens % Luminaire
0-30
0-40
0-60
60-90
70-100
90-120
0-90
90-180
0-180
Zone Lumens % Total Zone Lumens % Total
0-10 130.6
10-20 293.1
20-30 585.8
30-40
40-50
50-60
60-70
70-80
80-90
ZONAL LUMEN SUMMARY
1009.5 19.6%
2057.9 40%
3955.0 76.9%
1122.9 21.8%
5077.9 98.8%
5140.7 100%
LUMENS PER ZONE
2.5%
5.7%
11.4%
1048.3 20.4%
956.5 18.6%
940.6 18.3%
729.9 14.2%
335.5 6.5%
57.5 1.1%
410.5 8%
42.9 0.8%
62.8 1.2%
90-100 17.5
100-110 13.7
110-120 11.7
120-130 10.2
130-140 6.7
140-150
150-160
160-170
170-180
2.6 0%
0.4 0%
0 0%
0 0%
0.3%
0.3%
0.2%
0.2%
0.1%
180° 170° 160° 150° 140°
2000
1667
1333
1000
667
333
0
333
667
1000
1333
1667
2000
- 0° H
- 90° H
3
4
5
20 fc
10 fc
5 fc
2.5 fc
2
6
130°
120°
110°
100°
90°
80°
70°
60°
50°
40° 30° 20° 10° 0°
5
4
3
2
1
2
3
4
5
6
- 45° H
1 fc
0.5 fc
0.2 fc
0.1 fc
2
11100
3
4
5
50% Max Cd
Max Cd
For Group B applications, a Group B rated mounting hood must be used.
13