Appleton ATX™ SBDC Series Strobe Lighting and Static Triple Indicator Catalog Page

ATX™ SBDC Series Strobe Lighting and Static Triple Indicator
VISUAL SIGNAL: ATEX/IECEx FLAMEPROOF
© May 2016
Flameproof
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66/68 - IK08
Applications
• For use in hazardous locations in a wide range of plants.
• In areas where audible signals cannot be heard.
• To warn of unsafe conditions and other communication needs.
Features
• Threaded access cover with O-ring seal.
• Supplied with two external xing lugs.
• Fixtures operate in any position.
• External earth terminal 1 x 4 mm2 (0.002 x 0.006 in2).
• Two side M20 threaded entries supplied with 1 x M20 blanking plug.
• 15 Joules Strobe Beacon:
— Xenon lamp supplied. — Instantaneous illuminance: 150,000 candelas.
— Strobe 45 ashes per minute.
— Operating factor: 10 min. stop after one hour operation.
— Life duration: 70% efciency after 8 million ashes.
— Internal red colored lens supplied as standard.
— Other lenses available in ve colors:
– Amber, blue, green, yellow and clear (factory installed).
— Connection to plug-in terminal block via 2 x 3 x 2.5 mm
(0.003 x 0.005 x 0.004 in2) terminal.
• Static Triple Indicator Unit:
— Ba15d lamp holders. — Permissible lamps not supplied:
– 7 W incandescent or multi LED lamps. — Operating factor 100%. — Supplied with three colored interchangeable modules:
– Red, yellow and green. — Each module is controlled separately. — Possibility of coupling two modules for simultaneous
operation. — Connection to plug-in terminal block via 2 x 5 x 2.5 mm2
(0.003 x 0.008 x 0.004 in2) terminal.
Standard Materials
• End caps and cover: anti-corrosive gray painted Zamak
• O-ring seal: Nitrile
• Sealed toughened glass.
• Fixing lug: zinc plated steel
• Protective guard: zinc plated steel
Options
• Other colored module for static triple indicator unit.
• Other lens colors available for strobe lighting
ATEX/IECEx Certifications and Compliances
2
EURASEC Certification
Other Certification
Related Products
Strobe Lighting Multiple Static Indicator
• Certication Type: FLd
— Gas: Zones 1 and 2
– Conforming to ATEX 94/9/CE: II 2 G – Type of Protection: Ex d IIC – Temperature Class: See T Rating (Gas) and Surface
Temperature (Dust) Table
— Dust: Zone 21 and 22
– Conforming to ATEX 94/9/CE: II 2 D – Type of Protection: Ex tD A21 – Surface Temperature: See T Rating (Gas) and Surface
Temperature (Dust) Table
• Ambient Temperature: -40 °C to +55 °C (-40 °F to +131 °F)
• CE Declaration of Conformity: 50203
• ATEX Certicate: LCIE 97 ATEX 6012
• IECEx Certicate: IECEx LCI 04.0018
• Index of Protection according EN/IEC 60529: IP66/68 (10 meters)
• Impact Resistance (shock): IK08
• Internal Volume: 2 dm3 (122 in³) - 2 liters
• EURASEC N° TC RU C-FR.ГБ05.B.00912
• INMETRO Certicate: BVC11.0492
• For labels see Labels for Emergency Lighting Units, ATX Self­Adhesive Signaling Labels for Emergency Lighting Units.
T Rating (Gas) and Surface Temperature (Dust) Table
Gas Dust
Ambient Temperature
Strobe 15 Joules T6 T5 T95 °C (T203 °F)
Static Indicator T6 T6 T80 °C (T176 °F)
Inmetro certication available on special request only. Contact your local sales representative for more information.
Ta = +40 °C (+104 °F) Ta = +55 °C (+131 °F) Ta = +55 °C (+131 °F)
ATX™ SBDC Series Strobe Lighting and Static Triple Indicator
VISUAL SIGNAL: ATEX/IECEx FLAMEPROOF
© May 2016
Flameproof
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66/68 - IK08
Catalog Numbering Guide
SBDC F R 15 02D
SBDC - SBDC Series
Zone 1 and 2 – 21 and 22 ATEX/IECEx Certified
Red Strobe Beacon
Series:
C - Clear R - Red A - Amber G - Green B - Blue Y - Yellow M - Red/Yellow/Green
Type: S - Static F - Flashing
Type Supply Rating (Amps)
15 joules 24 Vdc 18-30 V 700 mA 6.8 (14.99) 31 (1891.7) SBDCFR1502D
15 joules 48 Vdc 40-60 V 350 mA 6.8 (14.99) 31 (1891.7) SBDCFR1504D
15 joules 110 Vac 95-127 V 50/60 Hz 350 mA 6.8 (14.99) 31 (1891.7) SBDCFR1511A
15 joules 230 Vac 185-255 V 50/60 Hz 190 mA 6.8 (14.99) 31 (1891.7) SBDCFR1523A
Color:
Wattage/Joules:
15 - 15 Joules LD - LED Lamp 07 - 7 W
Weight
kg (lb)
02D - 24 Vdc
Voltage:
02A - 24 Vac, 50/60 Hz 04D - 48 Vdc 04A - 48 Vac, 50/60 Hz 11A - 110 Vac, 50/60 Hz 23A - 230/240 Vac, 50/60 Hz
Volume
dm3 (in3) Catalog Number 
Triple Static Indicator
Type Lamp Holder Wattage
Red, yellow and green
230 Vac, 50/60 Hz
For lens color other than Red on the IECEx certified product change the replace the letter R in the 5th position to the appropriate option: C for Clear, A for Amber,
G for Green, B for Blue or Y for Yellow. Example for clear lens: SBDCFC1502D.
For LED lamp on the IECEx certified product change the replace the letters 15 or 07 with the letters LD in the 7th and 8th positions. Example: SBDCFRLD02D.
Ba15d 7 W 6.8 (14.99) 31 (1891.7) SBDCSM0723A
Weight kg (lb)
Volume
3
dm
(in3) Catalog Number
ATX™ SBDC Series Strobe Lighting and Static Triple Indicator
VISUAL SIGNAL: ATEX/IECEx FLAMEPROOF
© May 2016
Flameproof
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66/68 - IK08
Accessories and Replacement Parts
Type
Mounting Brackets – Quick One Hand Fixings: Set of Two
Weight
kg (lb)
Volume
dm3 (in3) Catalog Number
Surface Mounting Brackets: Set of Two
Half Clamps – Set of Two – Zinc Plated Steel
42 mm (1.25") to 49 mm (1.5")
Protective Guard
Dimensions in Millimeters (Inches)
Zinc plated steel
FDFBZ
0.40 (0.88) 0.7 (42.7)
Stainless steel FDFBS
Zinc plated steel
FDSBZ
0.55 (1.21) 0.5 (30.5)
Stainless steel FDSBS
FDHC49Z
0.80 (1.76) 0.5 (30.5)
60 mm (2") FDHC60Z
Zinc plated steel 0.55 (1.21) 8.0 (488.2) FDPG1Z
77.5 (3.05)
150 (5.91)
12 (0.47)
Diameter
12
(0.47)
25 (0.98)
335 (13.19)
11 (0.43)
5
(0.47)
15 (0.59)
(3.50)
89
85
(3.15)
191 (7.52)
430 (16.93)
Loading...