Appleton ATX™ SBDB Series Beacon and Strobe Lighting Units Catalog Page

Page 1
ATX™ SBDB Series Beacon and Strobe Lighting Units
VISUAL SIGNAL: ATEX/IECEx FLAMEPROOF
© May 2016
Flameproof
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66/67 – IK8
Applications
• For use in hazardous locations in a wide range of plants.
• In areas where audible signals cannot be heard.
• To warn of unsafe conditions and other communication needs.
Features
• Fixtures operate in any position.
• Mounting strap for surface mounting supplied.
• High temperature internal wiring.
• Stainless steel fastenings.
• Closed by screwing on bezel.
• Connection through an increased safety Exe compartment with terminal block
— Two 2 x 6 mm
4 mm2 (0.002 x 0.006 in2).
• External earth terminal 1 x 4 mm2 (0.002 x 0.006 in2).
• Two side M20 threaded entries supplied with:
— 1 x M20 plastic cable-gland for unarmored cable — 6.5 to
14.5 mm (0.26 x 0.57 in) sealing diameter.
— 1 x M20 blanking plug.
• Static Beacon:
— E27 lamp holder. — Permissible lamps not supplied:
– 100 W incandescent max.
– 18 W compact uorescent.
— Globe available in four colors:
– Red, amber, green and clear (to be ordered separately).
• Rotating Beacon:
— E14 lamp holder. — 40 W incandescent lamp supplied. — Rotating speed: approximately 170 rotations per minute. — Beaten mirror to reinforce bright effect. — Globe available in four colors:
– Red, amber, green and clear (to be ordered separately).
• 5 Joules Strobe Beacon:
— Xenon lamp supplied. — Instantaneous illuminance: 50,000 candles.
— Strobe 60 ashes per minute.
— Operating factor 100%.
— Life duration: 70% efciency after 8 million ashes.
— Internal red colored lens supplied as standard.
— Other lenses available in ve colors:
– Amber, blue, green, yellow and clear (factory installed).
2
(0.003 x 0.009 in2) and two earth terminal 1 x
Standard Material of Fixtures
• Body and bezel: gray painted marine aluminum
• Lens: colorless sealed shock resistant glass
• Internal reector for static beacon: aluminum
• Mounting strap: gray painted aluminum
Standard Material of Accessories
• Globe: colored Polymethacrylate
• Protective guard: zinc plated steel
Options
• Other lens colors for strobe beacon
ATEX/IECEx Certifications and Compliances
Other Certification
Strobe Lighting Beacon Lighting
• Certication Type: LTd (model (LT1d)
— Gas: Zones 1 and 2
– Conforming to ATEX 94/9/CE: II 2 G – Type of Protection: Ex de IIC – Temperature Class: See Temperature Rating — Gas table
on following page
— Dust: Zone 21-22
– Conforming to ATEX 94/9/CE: II2 D – Type of Protection: Ex tD A21 – Surface Temperature: See Temperature Rating — Dust table
on following page
• Ambient Temperature: — Strobe: -40 °C to +55 °C (-40 °F to +131 °F) — Rotating Beacon: -20 °C to +50 °C (-4 °F to +122 °F)
• CE Declaration of Conformity: 50246
• ATEX Certicate: LCIE 02 ATEX 6165
• IECEx Certicate: IECEx LCI Ex 04.0019
• Index of Protection according EN/IEC 60529: IP66/67
• Impact Resistance (shock): IK08
• INMETRO Certicate: BVC11.0417
Inmetro certification available on special request only. Contact your local sales representative for more information.
587
Page 2
ATX™ SBDB Series Beacon and Strobe Lighting Units
VISUAL SIGNAL: ATEX/IECEx FLAMEPROOF
© May 2016
Flameproof
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66/67 – IK8
Order using catalog numbering guide below or select catalog number from the following pages.
Catalog Numbering Guide — SBDB Series Beacon and Strobe Lighting Units
SBDB R C 40 04A
SBDB - SBDB Series
Temperature Rating — Gas
Lamp Type and Wattage
18 W Fluorescent Compact T6 T6 T6 T6 T5 T5
100 W Incandescent T4 T3 T3 T3 T3 T3
Strobe 5 Joules T6 T6 T6 T6 T6 T6
Series:
Zone 1 and 2 – 21 and 22 ATEX/IECEx Certified
Type: S - Static F - Flashing R - Rotating
Lighting Downwards Lighting Upwards
Ta = +40 °C (+104 °F) +50 °C (+122 °F) +55 °C (+131 °F) +40 °C (+104 °F) +50 °C (+122 °F) +55 °C (+131 °F)
40 W Rotating T5 T4 T4 T5 T4 T4
Color: C - Clear R - Red A - Amber G - Green B - Blue Y - Yellow
02D - 24 Vdc
Voltage:
02A - 24 Vac, 50/60 Hz 04D - 48 Vdc 04A - 48 Vac, 50/60 Hz 11A - 110 Vac, 50/60 Hz 11D - 110 Vdc 24A - 230/240 Vac, 50/60 Hz
Wattage/Joules:
40 - 40 W 10 - 100 W 05 - 5 Joules
Ambient Temperature
Temperature Rating — Dust
Positions
Lamp Type and Wattage
Ta = +55 °C (+131 °F) +55 °C (+131 °F)
18 W Fluorescent Compact T80 °C (T176 °F) T95 °C (T203 °F)
100 W Incandescent T195 °C (T383 °F) T195 °C (T383 °F)
40 W Rotating T130 °C (T266 °F) T130 °C (T266 °F)
Strobe 5 Joules T80 °C (T176 °F) T80 °C (T176 °F)
Lighting Downwards Lighting Upwards
588
Page 3
ATX™ SBDB Series Beacon and Strobe Lighting Units
VISUAL SIGNAL: ATEX/IECEx FLAMEPROOF
© May 2016
Flameproof
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66/67 – IK8
Type Supply
Clear Static Beacon
100 W Maximum 7.5 (16.3) 30 (1830.7) SBDBSC
Clear Rotating Beacon
40 W 48 Vac +-10% 50/60 Hz 1A 8.5 (18.74) 30 (1830.7) SBDBRC4004A
40 W 48 Vdc +-10% 1A 8.5 (18.74) 30 (1830.7) SBDBRC4004D
40 W 110 Vac +-10% 50/60 Hz 0.5A 8.5 (18.74) 30 (1830.7) SBDBRC4011A
40 W 230/240 Vac +-10% 50/60 Hz 0.23A 8.5 (18.74) 30 (1830.7) SBDBRC4024A
Red Strobe Beacon
5 joules 24 Vac 20-30 V 50/60 Hz 220 mA 8.5 (18.74) 30 (1830.7) SBDBFR0502A
5 joules 24 Vdc 18-35 V 230 mA 8.5 (18.74) 30 (1830.7) SBDBFR0502D
5 joules 48 Vac 40-54 V 50/60 Hz 180 mA 8.5 (18.74) 30 (1830.7) SBDBFR0504A
5 joules 48 Vdc 40-60 V 150 mA 8.5 (18.74) 30 (1830.7) SBDBFR0504D
5 joules 110 Vac 90-135 V 50/60 Hz 110 mA 8.5 (18.74) 30 (1830.7) SBDBFR0511A
5 joules 110 Vdc 88-132 V 90 mA 8.5 (18.74) 30 (1830.7) SBDBFR0511D
5 joules 230/240 Vac 185-255 V 50/60 Hz 55 mA 8.5 (18.74) 30 (1830.7) SBDBFR0523A
Accessories and Replacement Parts
Description Catalog Number
Polymethacrylate Globe
Zinc Plated Steel Protective Guard
Rating
(Amps)
Red SBDGR
Green SBDGG
Amber SBDGA
Clear SBDGC
Weight
kg (lb)
Volume
dm3 (in3) Catalog Number
Zinc Plated Steel Hinged Bracket
Zinc Plated Steel M10 Eyebolt
Using without colored globe LDPG1Z
Bracket for installation on
flat surface
Eyebolt for suspension LDRBM10Z
LDMHBZ
589
Page 4
Ø 232 (9.13)
10 (0.39)
(0.47)
ATX™ SBDB Series Beacon and Strobe Lighting Units
VISUAL SIGNAL: ATEX/IECEx FLAMEPROOF
© May 2016
Flameproof
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66/67 – IK8
Dimensions in Millimeters (Inches)
With Globe - 392 (15.43)
Without Globe - 353 (13.9)
Ø 12
194 (7.64)
295 (11.61)
590
Loading...