Appleton ATX™ RE Series Recessed and Surface Mounting Fluorescent Luminaires Catalog Page

Page 1
FLUORESCENT/AREA: ATEX/IECEx STANDARD AND EMERGENCY BACK-UP
© May 2016
ATX
Standard and Emergency Back-Up. Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09/10
Applications
• Designed for ush or surface mounting; most specically
clean room environments where a seamless smooth ceiling is mandatory.
• Typical applications include: the food industry, chemical plants, pharmaceuticals and delicate electronic manufacturing such as the aerospace industry.
• Ideal for use in rigorous corrosive environments, involving water, dust and extreme temperature variations.
• Can be installed in hazardous areas designated as Zone 1 and 2 – 21 and 22.
Features
• One piece welded steel housing with integral frame to seal out contaminants.
• Allows recessed mounting in permanent ceilings from 55 mm to 130 mm (2.17 to 5.12 in).
• Frameless tempered 5 mm (1/4 in) thick lens. Lens secured to housing by internal metallic hinges and secured with captive 316L stainless steel screws, allowing for easy lamp replacement
and xture maintenance.
• Positive safety switch and Ex e battery with plug-in connector for safety and easy maintenance in hazardous locations.
• Designed for ease of installation and maintenance.
• Bi-pin G13 lampholder.
• Also available as surface mounting version.
• New ballast:
— EOL (End Of Life) protection in accordance to the latest EN
60079-7 standard — Multi-tap 110 to 254 Vac/Vdc +/-10% 50/60 Hz — Two channel standard ballast (if one lamp fails the second
lamp remains in operation) — Ex e plug-in connector for rapid and error free maintenance — Self test on 3 hours duration emergency version — High power factor electronic ballast (>0.95)
• Cable entries: — Three clearance holes for M20 cable gland supplied with M20
polyamide cable gland — cable diameter 6.5 to 14.5 mm (0.26 to 0.57 in) — and M20 polyamide blanking plug. See Standard Cable Entry Accessories on following pages.
— One M6 earth stud.
Standard Materials
• Housing and integral frame: one piece, welded steel
• Safety lens: 5 mm (0.20 in) thick tempered
• Gasket: silicone, 4 lips, completely sealed and contained in the
xture
• Internal reector: white polycarbonate multi-parabolic
• Cable gland and blanking plug: polyamide
Standard Finishes
• Housing and integral frame: white powder epoxy paint
Options
• 3 hours emergency version - Battery 6 V - 4 Ah. Add sufx -E.
• 1 hour 30 emergency (combined) - Battery 6 V - 7 Ah. Add sufx
-E1.
• 3H Emergency (combined) - Battery 6 V - 7 Ah. . Add sufx -E7.
Without safety switch. Add sufx -N.
White painted steel internal reector. Add sufx -P.
• 316L stainless steel housing and integral frame, natural nish.
Add sufx -S.
4 x 18 W Surface Mounting
2 x 36 W Recessed
ATEX/IECEx Certifications and Compliances
• Certication Type: RE
— Gas: Zones 1 and 2
– Conforming to ATEX 94/9/CE: II2 G – Type of Protection: Ex de IIC/ Ex demb IIC (emergency
version)
– T-Rating: T6 to T4 (See Table on following page)
— Dust: Zone 22
– Conforming to ATEX 94/9/CE: – Type of Protection: Ex tD A21 – Surface Temperature: T75 °C (T165 °F)
• Ambient Temperature: -20 °C Ta +55 °C (-4 °F Ta +131 °F)
• CE Declaration of Conformity: 50276
ATEX Certicate: LCIE 07 ATEX 6104
IECEx Certicate: IECEx LCI 07.0019
• Index of Protection according EN/IEC 60529: IP66
• Impact Resistance (shock): IK09 or IK10 depending on version
II2 D
EURASEC Certification
• EURASEC N° TC RU C-FR.ГБ05.B.00912
Other Certification
• INMETRO Certicate: BVC13.2672
Inmetro certication available on special request only. Contact your local sales representative for more information.
535
Page 2
FLUORESCENT/AREA: ATEX/IECEx STANDARD AND EMERGENCY BACK-UP
© May 2016
ATX
Standard and Emergency Back-Up. Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09/10
Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide — RE Series Recessed Fluorescent Luminaires
RE B 1 18 BU F L E
RE - RE Series
Series:
Zone 1 and 2 – 21 and 22 ATEX/IECEx Certified
Wattage: 18 - 18 Watt 36 - 36 Watt 58 - 58 Watt
Termination/Wiring: L - Loop In/Loop Out T - Through wired
Lamp Type:
B - Bi-pin (G13)
Number of Lamps:
1 - Single 2 - Double 3 - Three Lamps 4 - Four Lamps
Voltage:
B3 - 100 to 130 Vac/
Vdc, 50/60 Hz
BU - 110 to 254 Vac/
Vdc, 50/60 Hz
BK - 220 to 240 Vac/
Vdc, 50/60 Hz
F - Recessed Front Access (U
Shape)
M - Surface Mounting Lighting
Options:
E - 3H Emergency
(combined) - Battery 6 V - 4 Ah
E1 - 1 H 30 Emergency
(combined) - Battery 6 V - 7 Ah
E7 - 3H Emergency
(combined) - Battery
6 V - 7 Ah N - No switch P - White painted steel
internal reflector S - 316L stainless steel
housing
Mounting/Access:
T/W and Loop in/Loop out - 3 cores (single phase). Only for standard versions. As standard for 18 W emergency version and 4 lamp version.
536
Page 3
FLUORESCENT/AREA: ATEX/IECEx STANDARD AND EMERGENCY BACK-UP
© May 2016
ATX
Standard and Emergency Back-Up. Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09/10
T Ratings
Ambient Temperature
Ceiling Position Wall Position
Version 40 °C (104 °F) 50 °C (122 °F) 55 °C (131 °F) 40 °C (104 °F) 50 °C (122 °F) 55 °C (131 °F)
2 x 18 W
2 x 18 W Emergency
3 x 18 W T5 T4 T4 T4 T4 T4
4 x 18 W T5 T4 T4 T5 T4 T4
2 x 36 W
2 x 36 W Emergency
3 x 36 W T4 T4 T4 T4 T4 T4
4 x 36 W T5 T4 T4 T5 T4 T4
2 x 58 W
2 x 58 W Emergency
3 x 58 W T4 T4 T4 T4 T4 T4
4 x 58 W
Termination and Wiring
2
• Terminal capacity: 4 mm
• Loop in/Loop out: One terminal block — Standard version: 2 (L) + 2 (N) + 2 (PE) — Emergency version: 2 (LP) + 2 (L) + 2 (N) + 2 (PE)
• Through wired: Two terminal blocks (one at each end) — Standard version: 2 (L) + 2 (N) + 2 (PE) 1 (L) + 1 (N) + 1 (PE) — Emergency version: 2 (LP) + 2 (L) + 2 (N) + 2 (PE) 1 (LP) + 1 (L) + 1 (N) + 1 (PE)
(0.006 in2) exible or 6 mm2 (0.009 in2) solid.
T6 T5 T5 T5 T5 T4
T5 T4 T4 T5 T5 T4
T5 T4 T4 T5 T4 T4
T5 T4 T4 T5 T4 T4
T4 T4 T4 T4 T4 T4
T4 T4 T4 T4 T4 T4
T4 T4 T4 T4 T4 T4
Standard Cable Entry Accessories
Version Cable Gland Blanking Plug Nickel Plated Brass Locknut
Loop 1 1 3
Through 2 1 3
T Rating for single lamp version is the same as twin lamp version. PE: Earth; N: Neutral. L: Live. LP: Permanent Live for emergency version.
537
Page 4
FLUORESCENT/AREA: ATEX/IECEx STANDARD AND EMERGENCY BACK-UP
© May 2016
ATX
Standard and Emergency Back-Up. Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09/10
Recessed — 110/254 Vac/Vdc, 50/60 Hz — Front Access — White Painted Steel Housing
Version Reflector Wiring
Standard Version — Bi-pin Lamps (G13)
2 x 18 W Polycarbonate
4 x 18 W White Painted Steel
2 x 36 W Polycarbonate
4 x 36 W White Painted Steel
2 x 58 W Polycarbonate
4 x 58 W White Painted Steel
3 Hours Emergency Version — Bi-pin Lamps (G13)
2 x 18 W Polycarbonate
4 x 18 W White Painted Steel
2 x 36 W Polycarbonate
4 x 36 W White Painted Steel
2 x 58 W Polycarbonate
4 x 58 W White Painted Steel
Loop 14 (30.86) 64 (3905.52) REB218BUFL
Through 14 (30.86) 64 (3905.52) REB218BUFT
Loop 21 (46.30) 93 (5675.21) REB418BUFLP
Through 21 (46.30) 93 (5675.21) REB418BUFTP
Loop 19 (41.89) 108 (6590.56) REB236BUFL
Through 19 (41.89) 108 (6590.56) REB236BUFT
Loop 29 (63.93) 158 (9641.75) REB436BUFLP
Through 29 (63.93) 158 (9641.75) REB436BUFTP
Loop 22 (48.50) 130 (7933.09) REB258BUFL
Through 22 (48.50) 130 (7933.09) REB258BUFT
Loop 32 (70.55) 190 (11594.51) REB458BUFLP
Through 32 (70.55) 190 (11594.51) REB458BUFTP
Loop 14 (30.86) 64 (3905.52) REB218BUFLEP
Through 14 (30.86) 64 (3905.52) REB218BUFTEP
Loop 21 (46.30) 93 (5675.21) REB418BUFLEP
Through 21 (46.30) 93 (5675.21) REB418BUFTEP
Loop 19 (41.89) 108 (6590.56) REB236BUFLE
Through 19 (41.89) 108 (6590.56) REB236BUFTE
Loop 29 (63.93) 158 (9641.75) REB436BUFLEP
Through 29 (63.93) 158 (9641.75) REB436BUFTEP
Loop 22 (48.50) 130 (7933.09) REB258BUFLE
Through 22 (48.50) 130 (7933.09) REB258BUFTE
Loop 32 (70.55) 190 (11594.51) REB458BUFLEP
Through 32 (70.55) 190 (11594.51) REB458BUFTEP
Weight
kg (lb)
Volume
3
dm
(in3)
Catalog Number

For surface mounting lighting, replace letter F with letter M in the 9th position; example: REB218BUML. For 3 hours emergency version - Battery 6 V - 4 Ah, add suffix E to the end of the catalog number; example: REB218BUFLE. For 1 hour 30 emergency (combined) - Battery 6 V - 7 Ah, add suffix E1 to the end of the catalog number; example: REB218BUFLE1. For 3H Emergency (combined) - Battery 6 V - 7 Ah, add suffix E7 to the end of the catalog number; example: REB218BUFLE7. For fixture without a safety switch, add suffix N to the end of the catalog number; example: REB218BUFLN. For fixture with a white painted steel internal reflector, add suffix P to the end of the catalog number; example: REB218BUFLP. For fixture with 316L stainless steel housing and integral frame and natural finish, add suffix S to the end of the catalog number; example: REB218BUFLS.
538
Page 5
FLUORESCENT/AREA: ATEX/IECEx STANDARD AND EMERGENCY BACK-UP
© May 2016
ATX
Standard and Emergency Back-Up. Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09/10
Accessories and Replacement Parts
Fixing Brackets - Set of four
Zinc plated steel 0.60 (1.32) REFBST
316 stainless steel 0.60 (1.32) REFBSS
Ceiling Mounting Brackets - Set of two
Zinc plated steel 2.00 (4.41) RECMST
316 stainless steel 2.00 (4.41) RECMSS
M8 Eye Bolts - Set of four
Zinc plated steel 0.25 (0.55) REEBST
316 stainless steel 0.25 (0.55) REEBSS
Description Weight kg (lb) Catalog Number
539
Page 6
FLUORESCENT/AREA: ATEX/IECEx STANDARD AND EMERGENCY BACK-UP
© May 2016
ATX
Standard and Emergency Back-Up. Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09/10
Wiring Diagram Emergency Function Diagram
Mains
PE N L
Lighting Switch
L’
Two Lamp Version
Mains Lighting Switch ON Lighting Switch OFF
ON
LED Status
U
Standard Fluorescent
N
Lighting Fixture
PE
U’
Emergency Fluorescent
U
Lighting Fixture
N PE
Color Indication Function
Green
Red LED blinks Batteries are not connected or defect
Yellow LED blinks Batteries are charging and discharging during automatic cycle
LED glows Batteries are connected
LED blinks Batteries are charged
Three Lamp Version
OFF
Mains Lighting Switch ON Lighting Switch OFF
ON
OFF
Emergency Light Duration
Version Battery Capacity Duration Light Output
2 x 18 W 4 Ah – 6 V 3 hours 45%
2 x 36 W
2 x 58 W
540
4 Ah – 6 V 3 hours 15%
7 Ah – 6 V 3 hours 25%
4 Ah – 6 V 3 hours 9%
7 Ah – 6 V 3 hours 15%
Page 7
FLUORESCENT/AREA: ATEX/IECEx STANDARD AND EMERGENCY BACK-UP
© May 2016
ATX
Standard and Emergency Back-Up. Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09/10
Dimensions in Millimeters (Inches)
Recessed Surface Mounting
B
C
(5.23”)
132.5 mm
2.0 mm (0.08”)
4 x Ø 8.5 mm (0.33”)
A
B
D
(5.30”)
134.5 mm
E
F
Ceiling Cut-out
G
H
C
4 x Ø 8.5 mm (0.33”)
A
D
E
F
Versions A B C D E F G H
18 W (1, 2, 3 lamps) 826 (32.52) 320 (12.60) 270 (10.63) 776 (30.55) 390 (15.35) 184 (7.24) 786 (30.94) 280 (11.02)
18 W (4 lamps) 826 (32.52) 490 (19.29) 440 (17.32) 776 (30.55) 390 (15.35) 354 (13.94) 786 (30.94) 450 (17.72)
36 W (1, 2, 3 lamps) 1436 (56.54) 320 (12.60) 270 (10.63) 1386 (54.57) 1000 (39.37) 184 (7.24) 1396 (54.96) 280 (11.02)
36 W (4 lamps) 1436 (56.54) 490 (19.29) 440 (17.32) 1386 (54.57) 1000 (39.37) 354 (13.94) 1396 (54.96) 450 (17.72)
58 W (1, 2, 3 lamps) 1736 (68.35) 320 (12.60) 270 (10.63) 1686 (66.38) 1300 (51.18) 184 (7.24) 1696 (66.77) 280 (11.02)
58 W (4 lamps) 1736 (68.35) 490 (19.29) 440 (17.32) 1686 (66.38) 1300 (51.18) 354 (13.94) 1696 (66.77) 450 (17.72)
541
Page 8
ATX™ RE Series Recessed and Surface Mounting Fluorescent Luminaires
FLUORESCENT/AREA: ATEX/IECEx STANDARD AND EMERGENCY BACK-UP
© May 2016
Standard and Emergency Back-Up. Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09/10
Photometric Data
Polar curves for a 1000 lm flux, according to NF C 71-120 Luminaire symbol according to NF C 71-121
1 x 18 W Efficiency 67.1% NF C 71-121: 0.67 E
CANDELA DISTRIBUTION CANDELA DISTRIBUTION CANDELA DISTRIBUTION
0-180 90-270
0 209 209 0 205 205 0 201 201
5 208 208 5 204 203 5 200 201 10 205 208 10 202 203 10 197 201 15 201 207 15 197 202 15 193 200 20 194 205 20 191 201 20 187 197 25 186 203 25 182 201 25 179 195 30 176 201 30 173 200 30 169 192 35 164 197 35 161 192 35 158 189 40 151 192 40 148 183 40 145 181 45 136 185 45 133 177 45 131 170 50 120 177 50 117 173 50 115 155 55 102 164 55 99 168 55 98 132 60 83 141 60 80 168 60 80 107 65 63 115 65 61 163 65 61 80 70 43 77 70 41 154 70 41 53
2 x 18 W
Efficiency 60.5% NF C 71-121: 0.60 F
CANDELA DISTRIBUTION CANDELA DISTRIBUTION
0-180 90-270
0 196 196 0 194 194
5 195 196 5 193 194 10 193 195 10 191 195 15 189 195 15 186 195 20 183 193 20 181 193 25 175 191 25 173 192 30 166 187 30 164 190 35 155 182 35 153 185 40 143 174 40 141 179 45 129 162 45 128 171 50 114 147 50 113 160 55 98 131 55 96 146 60 79 109 60 78 127 65 60 85 65 60 106 70 40 62 70 40 82
4 x 36 W
Efficiency 61.5% NF C 71-121: 0.61 E
CANDELA DISTRIBUTION
0-180 90-270
0 190 190
5 289 190 10 287 190 15 183 189 20 177 188 25 170 186 30 162 182 35 151 178 40 139 172 45 126 163 50 111 152 55 96 138 60 78 121 65 60 102 70 42 80
0° 15°
0° 15°
0° 15°
90°
75°
60°
45°
30°
90°
75°
60°
45°
30°
90°
75°
60°
45°
30°
2 x 18 W
Efficiency 62% NF C 71-121: 0.62 E
0-180 90-270
4 x 18 W
Efficiency 63.7% NF C 71-121: 0.63 E
0-180 90-270
0° 15°
0° 15°
90°
75°
60°
45°
30°
90°
75°
60°
45°
30°
3 x 18 W
Efficiency 61.2% NF C 71-121: 0.61 E
0-180 90-270
Longitudinal Transverse
0° 15°
90°
75°
60°
45°
30°
542
Page 9
ATX™ RE Series Recessed and Surface Mounting Fluorescent Luminaires
FLUORESCENT/AREA: ATEX/IECEx STANDARD AND EMERGENCY BACK-UP
© May 2016
Standard and Emergency Back-Up. Increased Safety
ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66 - IK09/10
Photometric Data
Polar curves for a 1000 lm flux, according to NF C 71-120 Luminaire symbol according to NF C 71-121
1 x 36 W
Efficiency 64.4% NF C 71-121: 0.64 E
CANDELA DISTRIBUTION CANDELA DISTRIBUTION CANDELA DISTRIBUTION
0-180 90-270
0 196 196 0 198 198 0 207 207
5 195 196 5 197 198 5 207 208 10 192 196 10 194 198 10 204 208 15 188 194 15 190 197 15 199 206 20 182 192 20 184 196 20 193 204 25 174 189 25 176 195 25 185 202 30 165 188 30 167 195 30 175 200 35 154 185 35 156 194 35 164 196 40 152 181 40 144 191 40 151 189 45 129 176 45 130 184 45 136 178 50 114 170 50 115 172 50 120 162 55 97 159 55 98 154 55 103 139 60 80 143 60 80 129 60 84 112 65 61 116 65 62 101 65 65 83 70 43 76 70 43 72 70 45 55
1 x 58 W
Efficiency 64.9% NF C 71-121: 0.65 E
CANDELA DISTRIBUTION CANDELA DISTRIBUTION CANDELA DISTRIBUTION
0-180 90-270
0 189 189 0 182 182 0 185 185
5 188 189 5 182 183 5 185 185 10 187 188 10 181 183 10 183 185 15 184 187 15 178 182 15 181 184 20 181 186 20 174 182 20 177 182 25 176 185 25 170 182 25 172 180 30 170 185 30 164 181 30 166 178 35 162 184 35 156 181 35 159 174 40 150 180 40 145 178 40 147 168 45 136 175 45 131 172 45 133 158 50 119 169 50 116 162 50 118 144 55 102 162 55 99 148 55 100 125 60 83 146 60 81 126 60 82 101 65 63 122 65 52 99 65 63 75 70 43 85 70 43 70 70 43 49
0° 15°
0° 15°
90°
75°
60°
45°
30°
90°
75°
60°
45°
30°
2 x 36 W
Efficiency 64.8% NF C 71-121: 0.64 E
0-180 90-270
2 x 58 W
Efficiency 61.8% NF C 71-121: 0.62 E
0-180 90-270
0° 15°
0° 15°
90°
75°
60°
45°
30°
90°
75°
60°
45°
30°
3 x 36 W
Efficiency 63.7% NF C 71-121: 0.63 F
0-180 90-270
3 x 58 W
Efficiency 57.8% NF C 71-121: 0.58 E
0-180 90-270
Longitudinal Transverse
0° 15°
0° 15°
90°
75°
60°
45°
30°
90°
75°
60°
45°
30°
543