Appleton ATX™ D Series Aluminum Control Stations Catalog Page

Page 1
ATX™ D Series Aluminum Control Stations
CONTROLS: ATEX/IECEX FLAMEPROOF CONTROL STATIONS AND RELAYS
© June 2017
Flameproof
ATEX:
Zone 1 and 2 – 21 and 22
II 2 GD
IP66 – IK10
• Local control stations for use in hazardous areas.
• Control of electrical equipment at power plants, chemical and
petrochemical plants, petroleum reneries, pulp and paper
processing plants and various industrial applications.
Features
• 1 and 2 Function Ex d IIC: — Supplied with actuators, contact blocks and pilot lights. — TS35 rail mounted contact blocks.
— Threaded ameproof joint.
— Connection: 2 x 2.5 mm2 (0.004 in2) maximum. — Internal earth: 2 x 4 mm2 (0.006 in2). — External ground: M5 — 1 x M20 or M25 threaded entry at bottom. — Cable glands and plugs to be ordered separately.
• 2 and 3 Function Exd IIB: — Supplied with actuators and rail mounting pilot lights and
contact blocks.
— Flanged ameproof joint.
— Yellow laminated plastic legend plate with black lettering. — Connection : 2 x 2.5 mm — Internal earth: 2 x 4 mm2 (0.006 in2). — External earth: M6 screw. — 2 x M20 threaded entries at the bottom. — Cable glands and plugs to be ordered separately.
2
(0.004 in2) maximum.
Standard Materials
• Box: gray painted marine grade aluminum alloy
Options
• For other congurations, see pre-drilled control stations or
consult factory.
ATEX Certifications and Compliances
Certication Type BR1d
— Gas, Zones 1 and 2
– Conforming to ATEX 94/9/CE: II 2 G – Type of Protection: Ex d IIC – Temperature Class: T6 for Ta = +40 °C (+104 °F), T5 for
Ta = +55 °C (+131 °F)
— Dust, Zones 21 and 22
– Conforming to ATEX 94/9/CE: II2 D – Type of Protection: Ex tD A21 – Surface Temperature: T95 °C (T203 °F)
— Ambient Temperature: -40 °C to +55 °C (-40 °F to +131 °F) — CE Declaration of Conformity: 20530
— ATEX Certicate: LCIE 02 ATEX 6056
Certication Type CF2D
— Gas, Zones 1 and 2
– Conforming to ATEX 94/9/CE: II 2 G – Type of Protection: Ex d IIB – Temperature Class: T6 for Ta +40 °C (+104 °F), T5 for
+40 °C (+104 °F) < Ta +55 °C (+131 °F)
— Dust, Zones 21 and 22
– Conforming to ATEX 94/9/CE: II2 D – Type of Protection: Ex tD A21 – Surface Temperature: T95 °C (T203 °F)
— Ambient Temperature: -40 °C to +55 °C (-40 °F to +131 °F) — CE Declaration of Conformity: 50254
— ATEX Certicate: LCIE 03 ATEX 6061X
1 Function 2 Function
2 Function 3 Function
— Index of Protection according EN/IEC 60529: IP66 — Impact Resistance (shock): IK10 — Internal Volume: 2 dm
3
(122 in³) - 2 liters
EURASEC Certification
• EURASEC RU C-FR. ГБ05.B.00911
Other Certification
INMETRO Certicate: BVC 11.0482
INMETRO certification available on special request only. Contact your local sales representative for more information.
257
Page 2
ATX™ D Series Aluminum Control Stations
CONTROLS: ATEX/IECEX FLAMEPROOF CONTROL STATIONS AND RELAYS
© June 2017
Flameproof
ATEX:
Zone 1 and 2 – 21 and 22
II 2 GD
IP66 – IK10
Type Description/Function
1 Function Ex d IIC Control Stations
Spring Return Push Button
BR1d
BR1d
Mushroom Head Push Button
BR1d
BR1d
BR1d
BR1d
Time Delayed Push Button 230 V 50/60 Hz
BR1d
BR1d
Twin Push Buttons
BR1d
BR1d
2 Function Ex d IIB Control Stations
Twin Push Buttons
CF2D
CF2D
1x black spring return push button
with 1NO + 1NC
momentary contacts
1x black spring return push button
with 1NO + 1NC
momentary contacts
1x red mushroom head
push-pull with 1NO + 1NC
maintained contacts
Padlockable in both positions
1x red mushroom head
push-pull with 1NO + 1NC
maintained contacts
Padlockable in both positions
Red mushroom head key release
with 1NO + 1NC maintained contact
Unlocked with key (MS1)
Red mushroom head key release
with 1NO + 1NC maintained contact
Unlocked with key (MS1)
1x time delayed black impulse push button adjustable from 25s to 15mn
For 1000 W incandescent or 400 W
fluorescent max.
1x time delayed black impulse push
button adjustable from 25 s to 15
mn For 1000 W incandescent or
400 W fluorescent max.
1x green spring return ‘I’ push
button with 1NO momentary contact
1x red spring return ‘0’ push button
with 1NC momentary contact
1x green spring return ‘I’ push
button with 1NO momentary contact
1x red spring return ‘0’ push button
with 1NC momentary contact
1x green spring return ‘I’ push
button with 1NO momentary contact
1x red spring return ‘0’ push button
with 1NC momentary contact
1x green spring return ‘I’ push
button with 1NO momentary contact
1x red mushroom head push-pull
with 1NO+1NC maintained contacts
Bottom Entries
1 x M20
1 x M25
1 x M20
1 x M25
1 x M20
1 x M25
1 x M20
1 x M25
1 x M20
1 x M25
2 x M20
2 x M20
Weight
kg (lb)
1.0
(2.20)
1.0
(2.20)
1.2
(2.65)
1.2
(2.65)
1.2
(2.65)
1.2
(2.65)
1.2
(2.65)
1.2
(2.65)
1.2
(2.65)
1.2
(2.65)
2.5
(5.51)
2.5
(5.51)
Volume
dm3 (in3) Catalog Number
3.75
(24.41)
3.75
(24.41)
3.75
(24.41)
3.75
(24.41)
3.75
(24.41)
3.75
(24.41)
3.75
(24.41)
3.75
(24.41)
3.75
(24.41)
3.75
(24.41)
7.00
(427.17)
7.00
(427.17)
DA1W1T101
DA1W3T101
DA1W1T102
DA1W3T102
DA1W1T104
DA1W3T104
DA1W1T103
DA1W3T103
DA1W1T201
DA1W3T201
DA2W2T201
DA2W2T202
258
Page 3
ATX™ D Series Aluminum Control Stations
CONTROLS: ATEX/IECEX FLAMEPROOF CONTROL STATIONS AND RELAYS
© June 2017
Flameproof
ATEX:
Zone 1 and 2 – 21 and 22
II 2 GD
IP66 – IK10
Type Description/Function
3 Function Ex d IIB Control Stations
Pilot Light and Twin Push Buttons
1x red/green LED light 85 to
CF2D
Ammeter and Twin Push Buttons
CF2D
Ex d IIC Limit Switch
Limit Switch
Stainless steel roller control perpendicular for surface fixing. 1/4 turn fixing (may be modified by end user).
BR1d
BR1d
Contact Block LED Pilot Light
Insulation Voltage (Ui) 500 V Rated Voltage 85 Vac to 264 Vac, 50/60 Hz
Switching Capacity Rating 5-15 mA
AC 15 4 A/115 V, 4 A/230 V, 2 A/500 V Max. Power 0.33 W
DC 13
Terminal connections
Operation life >5,000,000 Operations
264 Vac 1x green spring return ‘I’
push button with 1NO momentary contact 1x red spring return ‘0’ push button with 1NC momentary contact
1x ammeter 48 x 48 CT1A 3 x FLC
0-1-3A 1x green spring return ‘I’
push button with 1NO momentary contact 1x red spring return ‘0’ push button with 1NC momentary contact
1x roller plunger - travel 7 mm max.
- Force 22 newtons with 1NO+1NC momentary contacts
1x roller plunger - travel 7 mm max.
- Force 22 newtons with 1NO+1NC momentary contacts
3 A/24 V, 1.7 A/42 V, 1.2 A/60 V, 0.8 A/110 V, 0.3 A/220 V
0.75 to 2.5 mm (0.001 to 0.004 in2 )
2
Technical Data
Bottom Entries
2 x M20
2 x M20
1 x M20
1 x M25
Operation life
Weight
kg (lb)
3.3
(7.28)
3.3
(7.28)
1.0
(2.20)
1.0
(2.20)
Volume
dm3 (in3) Catalog Number
9.00
(549.21)
9.00
(549.21)
4.60
(280.71)
4.60
(280.71)
Average 100,000 Hours at +25 °C (+77 °F)
DA5W2T301
DA5W2T302
DA1W1L001
DA1W3L001
Light Switch
Insulation Voltage (Ui) 500 V
Switching Capacity
AC 15 450 W/48 V, 900 W/110 V, 1900 W/230 V
DC 13 100 W/48 V, 100 W/110 V, 95 W/230 V
Terminal connections
Operation life > 1,000,000 Operations
0.75 to 2.5 mm (0.001 to 0.004 in2)
2
259
Page 4
ATX™ D Series Aluminum Control Stations
7 mm (0.28”)
41 mm (1.61”)
7 mm (0.28”)
7 mm (0.28”)
110 mm
50 mm
41 mm (1.61”)
7 mm (0.28”)
110 mm
20 mm (0.79”)
7 mm (0.28”)
(3.35”)
(course)
Ø 25 mm
110 mm (4.33”)
190 mm (7.48”)
110 mm (4.33”)
240 mm (9.45”)
CONTROLS: ATEX/IECEX FLAMEPROOF CONTROL STATIONS AND RELAYS
© June 2017
Flameproof
ATEX:
Zone 1 and 2 – 21 and 22
II 2 GD
IP66 – IK10
Electrical Diagrams
NO Contact Block NC Contact Block LED Pilot Light
Time Delayed Push Button
Dimensions in Millimeters (Inches)
1 Function 1 Function Emergency Stop 2 Functions
41 mm (1.61”)
110 mm
Ø 9 mm (0.35”)
(4.33”)
Limit Switch 2 Functions 3 Functions
7 mm
(0.28”)
41 mm (1.61”)
26 mm (1.02”)
107 mm
7 mm (0.28”)
41 mm (1.61”)
41 mm
Ø 9 mm (0.35”)
(1.61”)
260
41 mm (1.61”)
(4.21”)
(5.31”)
135 mm
85 mm
(0.98”)
185 mm (7.28”)
Ø 9 mm (0.35”)
126 mm (4.96”)
156 mm (6.14”)
145 mm (5.71”)
4.33/110
41 mm (1.61”)
(5.31”)
135 mm
Ø 9 mm (0.35”)
14 mm (0.55”)
Ø 9 mm (0.35”)
7 mm (0.28”)
126 mm (4.96”)
196 mm (7.72”)
145 mm (5.71”)
110 mm
(4.33”)
14 mm (0.55”)
41 mm (1.61”)
(5.31”)
135 mm
Ø 9 mm (0.35”)
125 mm
(4.92”)
Loading...