Wireless Cabinet Lock
Optional Addit ional Tools:
Drill, Drill bits: 1/16”, 3/16”, 1/2”
Flathead drivers 3/32”, 3/16”
Wireless Frequency: 2.4 GHz, IEEE 802.15.4, using AES 128-bit encryption
For technical support please call 1-800-626-7590
Installation Instructions
NOTE: The wireless hub and hub brack et a r e included with the K100-622H model.
HES, Inc.
Phoenix, A Z
1.800.626.7590
www.hesinnovations.com
1X
5X
3X
2X
1X
Breakaway
3X
2X
2X
Lithium Batteries
2X
Cam
Approved iCLASS or Prox ID
credential.
Hub Power Requirement: 8–24 Volts Dir ect C urrent (V DC ), 25 0 millia mp s (mA)
Lock Battery Type: Lithium AA Cell, 1.5 Volts (V) (Energizer L91 Ultim ate Lithium )
Battery Life: 50,000 cycles
Operating Temperatur e: 32 °F to 122 °F (0 °C to 50 °C)
FCC Part 15 Compliant, IC Compliant
Credentials Supported: (-PA) Low Frequency model: HID PROX, EM PROX
(-SE) High Frequency model: iCLASS, iCLASS SEOS , iCLASS SE, ISO14443B UID
Mifare, Mifare Plus, Desfire SE, Desfire EV1, NFC
3080076.004, Rev. B 1
Phillips drivers P 0, P2
Pencil, Wire Stripper, Level,
Square, Pliers
Gang box to mount hub
Cam Lock for Key Override
Tips and Videos
,
with a smart phone app

System Overview
access control to a c a b inet or drawer without the complexity and
Connecting the Hub
Mounting the Lock
Locating and Mounting the Hub
(K100-622H only)
The K100-622 series wireless cabinet lock provides
expense of running wires to the cabinet or drawer. The K100-622 series lock connects to an access control through
a communication hub (included with the K100-622H). The communication hub connects to the access control
system with Wiega nd wiring typical of a Wiegand Reader.
When a credential card is presen ted t o the reader on the lock the reques t for access is sent wirelessly to t he
communication hub. The communica tion hub then communicates through Wiegand wiring to the access control
system where the decision is made to grant or deny access.
Installation Process
(K100-622H only)
3080076.004, Rev. B 2

Choosing the hub location
NOTE: The following applies primarily
to the K100-622H Model with
included hub.
It is recommended that the hub be
mounted near th e top of a wall, on the
ceiling or above th e c e iling to reduce
potential for interference, and be facin g
toward the lock for be s t p erformance.
For a stable and relia ble radio link, it is
recommended that the hub is located
within fifty ( 50 ) feet of the lock. A
maximum of two interior walls
between the hub and lock is
recommended
Recommended locations:
A: Wall Mount
B: Ceiling Mount
C: Wall Mount, Adja c ent Room
NOTE: The hub is not rated for use in
plenum air spaces.
Mounting the Hub
NOTE: The following applies primarily to th e K 1 00-622H Model with included hub.
The included adapter plate c a n be used to mount the hub on a single or double gang box.
3080076.004, Rev. B 3

Connecting the Hub
If the RED LED sign a l is not connected, the lock will
1. CONNECT the Wiegand D1, D0, red and green LED signals.
3. CONNECT Latchbolt Position, Low
2. CONNECT 8–24 VDC and ground (250 mA).
NOTE: The following applies primarily to th e K 1 00 -622H Model with included hub.
®
The Aperio
(250mA). The hub includes th r ee Form C relays tha t can be used to transmit latch bolt position s ta tus, low
battery signal, and a tamper signal. The hub connects to the cabinet lock wirelessly.
NOTE 1: The Green LED input is used to grant access to the c a b inet lock. If the G r e en LED signal is not av a ila b le
NOTE 2: The Red LED input is used to indicate a c c es s denied.
Hub connects to the Access Control system via Wiegand wiring. The hub requires 8–24 VDC power
Battery, and Tamper Switch Detection
to indicate approved access, the a p pr oval input can be activ ated by a relay with “NO” attached to Green
LED and “C” to GND.
flash RED three times when a non-approved card is presented indicating loss of connection to the hub
rather than access denied. Any other codes may be reference on the LED r eference card.
3080076.004, Rev. B 4