Aperio DEMO-KS100-S-IPS-B Installation Instructions

Page 1 of 12 For more information visit website assaabloyesh.com P/N: 3080006.017_1
Product Specifications
Wireless Frequency: 2.4GHz, IEEE 802.15.4, using AES 128-bit encryption Lock Battery Type: AA Lithium, 1.5 Volts (V) Battery Life: 50,000 cycles* Holding Force: 400 lbs FCC Part 15 Compliant, Industry Canada Compliant Operating Temperature: 32 to 122 F (0 to 50 C) HID® multiCLASS SE® technology Credentials Supported: High Frequency (13.56 MHz) – HID iCLASS,
HID iClass SE (SIO-enabled), HID iCLASS Seos, HID MIFARE SE, HID DESfire EV1 SE, MIFARE CLASSIC DESfire EV1. Low Frequency (125KHz) – HID Prox, AWID, EM4102, ioProx. NFC Enabled Mobile Phones.
AA Lithium Batteries required. Use of other types of batteries, such as alkaline, will significantly decrease battery life.
2x
*All battery life claims are approximate and based on a set configuration profile. Battery performance is based on pre­defined system settings such as battery chemistry and battery model used, credential presentation settings (LED/buzzer), UHF polling period, UHF status intervals, and operations per day. Actual battery performance will vary and depends on the factors above.
HES KS100 Aperio Wireless Cabinet Lock
Installation and Operating Instructions
Page 2 of 12 For more information visit website assaabloyesh.com P/N: 3080006.017_1
Recommended tools
Cutting Wheel Phillips #2 Screwdriver
Hardware Specifications
Table 1 – Cam
DPS Cable Extension
Optional – The DPS signal is closed when the handle is resting in its locked position. The DPS circuit can be extended to include normally open DPS switches arranged in a series to monitor additional doors and panels
CAM
CAM LENGTH
CAM DEPTH
38mm - 4
(Standard)
38mm [1-1/2"]
26mm [1”]
38mm - 5
(Optional)
38mm [1-1/2”]
28mm
[1-1/10"]
45 mm - 1 (Optional)
45mm
[1-3/4”]
18mm
[7/10”]
For Technical Support Please call 1-800-810-WIRE
DPS Extension Cable
DPS
Switches
(SPST-NO):
As Needed
Optional
Switch #1
(SPST-NO):
Provided
Extending the DPS Circuit: A: Remove the DPS jumper B: Connect the included DPS extension
cable
C: Connect additional normally open
DPS switches as shown to monitor additional panels.
Page 3 of 12 For more information visit website assaabloyesh.com P/N: 3080006.017_1
Package Contents
Lock Body
Battery Bracket
Handle Assembly
Handing Selectors
SFIC Cam and
Spacer
Cam
2x AA Lithium
Batteries
Screw A
#1/4-20 x .50
Truss Head
Phillips
3x Screw B
8/32 x 5/16”
Pan Head
Phillips
Optional External DPS Cable
Harness
3x Dolphin
Connector
Note: SFIC mechanical key
override/SFIC blank sold
separately.
Page 4 of 12 For more information visit website assaabloyesh.com P/N: 3080006.017_1
Installing the Lock
1. Locate the 150mm x 25mm lock cutout on the door. Connect battery cable and optional DPS cable to lock body. Secure battery bracket to lockbody using 3x screw B.
2. Ensure lock body is flush against the mounting surface to depress tamper switch.
3. Select appropriate handing selector.
Tamper
Switch
Door Edge
Note: ensure that the arrow on the handing selector is pointing towards the edge of the door.
DPS Cable (optional)
Loading...