American Power Conversion p2324 User Manual

1
TM
TM
2
3
Multiport serial interface,Multiport serial interface,
Multiport serial interface,
Multiport serial interface,Multiport serial interface, async multiplexers, print spoolers,async multiplexers, print spoolers,
async multiplexers, print spoolers,
async multiplexers, print spoolers,async multiplexers, print spoolers, async to x.25/frameasync to x.25/frame
async to x.25/frame
async to x.25/frameasync to x.25/frame relay interfacerelay interface
relay interface
relay interfacerelay interface
4
TT
o individual serial poro individual serial por
T
o individual serial por
TT
o individual serial poro individual serial por
on workstation equipmenton workstation equipment
on workstation equipment
on workstation equipmenton workstation equipment
tsts
ts
tsts
Protect Net
Four Port RS232 Surge Protection
Model - P232-4
TM
Part #: 990-0160 Rev. 1 Revised 3/97 Copyright © 1997 American Power Conversion All Rights Reserved. ProtectNet and the Stylized APC logo are trademarks of APC.
Technical Support and Customer Service:
A.P.C. A.P.C. 132 Fairgrounds Road Ballybritt Business Park West Kingston, RI 02892 Galway, Ireland 1-800-800-4APC 1-800-702000 1-401-789-5735 353-91-702020
WWW/Internet/E-Mail
Internet: http://www.apcc.com E-Mail: apctech@apcc.com Compuserve: GO APCSUPPORT
Users Manual
APC Supplemental Equipment Protection Policy
(Valid only in the USA and Canada)
1. THIS SUPPLEMENTAL POLICY IS NOT A WARRANTY. REFER TO THE APC LIMITED WARRANTY STATEMENT FOR INFORMATION CONCERNING THE WARRANTY FOR THIS PRODUCT.
2. THE SUPPLEMENTAL EQUIPMENT PROTECTION POLICY (SEPP) IS VALID ONLY WHEN CONNECTED SYSTEM EQUIPMENT IS PROTECTED BY: A) BOTH THE APC DATA LINE PROTECTOR PRODUCT AND APC POWER (UTILITY LINE) PROTECTION EQUIP­MENT (e.g. uninterruptible power source or surge suppressor); OR, B) APC POWER PROTECTION EQUIPMENT WITH BUILT-IN DATA LINE PROTECTION. A special exception is made for electronic equipment properly connected to the ProtectNet model PTEL1-4, whose sole means of power is via the telephone line. In such case, the telephone service equipment must include a properly installed and operating “primary protection” device at the service entrance (such devices are normally added during premise telephone line installation) to be covered under this Policy. Call APC Technical Support (800) 800-4APC for a copy of the complete Equipment Protection Policy.
3. This SEPP is valid only when all data lines to and from the connected system equipment are protected by an APC protection product.
4. Refer to the Equipment Protection Policy (EPP) provided with the APC power protection product for general Policy descriptions and informa­tion on limitations, eligibility, and coverage qualifications. This Supplemental Equipment Policy supersedes the Equipment Protection Policy only as follows: A. Damage to electronic equipment resting from transients on data lines is covered with the exception of the following listed circumstances. Note that all other exceptions, conditions, and limitations of the EPP are maintained.
1. Damage caused by failure to provide a suitable environment for the product, including, but not limited to, lack of a proper safety ground.
2. Damage caused by the use of the APC product for purposes other than those for which it was designed.
3. Damage to Ethernet or Token Ring Network Interface Cards, Hubs, and other LAN connected equipment that do not meet the applicable isola­tion requirements of ANSI/IEEE Standard 802.3 (also ISO/IEC 8802-3) or ANSI/IEEE Standard 802.5. B. Reimbursement (cost or repair or fair market value) Dollar Limits, as stated in the EPP, are doubled in value for customers that meet the qualifica­tions and conditions set forth in both the SEPP and EPP.
5. Refer to the EPP for detailed information on submitting an Equipment Protection Policy Claim. Call the APC Customer Service Department at (800) 800-4APC if you require additional information.
Limited Warranty
American Power Conversion offers a limited Lifetime Warranty on ProtectNet surge suppressors. APC warrants its products to be free from defects in materials and workmanship under normal use and service for the lifetime of the original purchaser. Its obligation under this warranty is limited to repairing or replacing, at its sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Autho­rization (RMA) number from APC or an APC Service Center with transportation charges prepaid. The returned merchandise must be accompanied by a brief description of the problem and proof of date of purchase. This warranty applies only to the original purchaser.
1.0 Introduction
Thank you for purchasing this American Power Conversion surge protector, model P232-4. It is for use with RS232 communication equipment (RS232 multiports, async multiplexers, async printer spoolers) comprised of unshielded, twisted-pair wiring with RJ­45 connectors. It protects up to four ports per unit. Use as many P232-4s as needed to protect your network. P232-4 comes with 4 network jumper cables, stack or wall mount brackets and screws, and grounding cables. See figure 1. Up to 10 P232-4s can be rack mounted using the APC rack mounting kit, part number PRM, available from your dealer or from APC at 1-800-800-4APC. See figure 2 for optional rack mount configuration. Please fill out and return the enclosed warranty registration card.
2.0 Safety
Please read and save these instructions, and take the following safety precautions.
n Use the P232-4 in a protected environment only. n To fully protect the user and equipment, the product must
be connected to a proper ground as described in 3.0 below.
3.0 Installation
1. Refer to figure 4. To install the ProtectNet with existing LAN equipment, skip to paragraph 2 below. For new installations, complete installation of all new RS232 equipment per the manufacturer’s instructions without the ProtectNet and verify that the new equipment operates properly.
2. Switch off the equipment to be protected and unplug the serial cables.
3. Plug the UTP cables from the RS232 ports into the P232-4 “IN” jacks as shown.
4. Attach the supplied patch cables between the P232-4 “OUT” jacks and the equipment UTP port jacks.
5. Connect the ProtectNet ground wire terminals to a proper ground (protective earth) as described in the section on ground­ing below .
6. The P232-4 can be placed on a flat surface, mounted on a wall, stacked, or mounted on the optional rack shelf. Figure 2 shows a rack mount installation. Figure 4 shows a typical sur­face installation.
7. Switch on protected equipment.
n Many APC UPSs provide a “TVSS Ground” screw for fasten-
ing the ground terminal. Use this screw wherever pos­sible. Again, verify that the UPS is plugged into a three-wire grounded outlet.
n Fasten the ground wire to the network system ground, if
possible, or beneath the head of a metal screw on the chas­sis of the protected equipment. Do not loosen chassis screws that secure internal components.
n Fasten the ground terminal beneath the head of a wall out-
let cover plate (120V systems only). Where possible, this should be the same outlet where your protected equipment is plugged in.
CAUTION: Disconnect power to the outlet by removing the branch fuse or switching off the circuit breaker before attempting to loosen the cover plate screw. Do not overtighten the screw.
n Fasten the ground terminal beneath a clamp secured around
a cold water pipe.
4.0 Specifications
Lines protected: All eight conductors. Mode of protection: between send/receive pairs and any signal
line to ground.
Peak voltage: ± 6,000 Volts, 1.2/50 µs test waveform. (IEEE587) Peak current: 250 Amps, 8/20 µs test waveform. (IEEE587) Breakover: (turn on) voltage: 19V nominal between send/re-
ceive pairs. Agency approvals: UL 497B listed Isolated Loop Circuit Protector
Grounding the ProtectNet
1. Verify that the protected equipment is plugged into a three­wire grounded outlet, if applicable. If your site has outlets with only two holes (no center ground), a qualified electrician should be called to upgrade your building wiring. Many APC UPS and surge suppression products have a Site Wiring Fault Indicator that warns of improper building wiring, including lack of a safety ground. An outlet wiring tester can be purchased at most hard­ware stores, though it is not as sensitive. Use of APC power protection equipment is recommended.
2. For ganged, stacked, or rack mounted units, connect the supplied short grounding wire from P232-4 to P232-4 daisy chain fashion. Then use the supplied long ground wire to make the ground connection. Ground the P232-4 by choosing one of the following measures, listed in order of preference. Do not ground to the rack mount shelf.
Loading...