American Power Conversion NS 600 User Manual

®
®
Back-UPS NS 600
User’ s Guide
1
2
w w w
.apc.com
Connect Battery
For safety, the Back-UPS NS is shipped with one battery wire disconnected. The UPS will not operate until the wire is connected to the touch-safe battery terminal. NOTE: Small sparks may occur during battery connection. This is normal.
Turn the Back-UPS NS over and press in the
1 2 3
two release tabs. Slide the plastic battery cover off the unit.
Plastic Battery
Cover
Connect
Release Tabs
Equipment
Battery Back-up plus Surge Protection
These outlets are powered whenever the Back-UPS NS is switched ON. During a power out a ge or other utility problems (brownouts, over-voltages), these outlets will be powered for a limited time by the Back-UPS NS. Plug your computer, monitor, CD-ROM drive and one other data-sensitive device such as an external disk or tape drive, or Home Phoneline Networking Association (HPNA) device into these outlets.
Battery Backup plus Surge Protection
Connect the battery wire firmly to the battery terminal.
Battery Terminal
Place the Back-UPS NS to avoid:
- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids
Plug the Back-UPS NS power cord directly into a wall outlet; not a surge protector or power strip.
Connect Computer Cable
The supplied cable and software provide automatic file saving and shutdown of the operating system in the case of a sustained power outage.
Connect the cable to the Data Port of the Back-UPS NS. Connect the other end of the cable to the USB port on your computer. The software will automatically find the USB Port of your computer.
Connect Modem / Phone / DSL / Fax / HPNA to Surge Protection
The Back-UPS protects a single line (2-wire) phone (including Digital Subscriber Line ­DSL), Home Phoneline Networking Association (HPNA) type equipment, modem, or fax machines from surges when connected through the UPS as shown below.
Battery Wire
Insert the battery back into the compartment. Slide the plastic battery cover in place until the two tabs lock into place.
3
Surge Protection
Power
Surge Protection
These outlets provide full-time protection from surges even if the Back-UPS NS is switched OFF. Plug your printer, fax machine, scanner, or other peripherals that do not need battery power into these outlets.
Power On and Install Software
Press the ON/OFF switch to power the unit ON.
A single short beep and the green “Power” indicator confirms the Back-UPS NS is on and ready to provide protection .
The Back-UPS NS should charge for at least 16 hours to ensure sufficient runtime. The unit is being charged whenever it is connected to utility power, whether the unit is turned ON or OFF.
If the red Building Wiring Fault indicator (located on the end near the power cord) is lit, your building wiring presents a shock hazard that should be corrected by a qualified electrician.
®
Install the PowerChute software
Place the PowerChute Personal Edition CD­ROM into your computer and follow the installation instructions on the screen.
Personal Edition
Status Indicators
The Back-UPS NS indicates operating status using a combination of visual and audible indicators.
On Line - UPS is supplying conditioned utility power to the load.
On Battery - UPS is supplying battery power to the load connected to the Battery outlets.
Low Battery Warning - UPS is supplying battery power to the load connected to the Battery outlets and the batter y i s near exhaustion.
Replace Battery - Battery needs to be checked and/or replaced, or battery is not connected.
Overload Shutdown - During On Battery operation a battery power supplied outlet overload was detected.
Sleep Mode - During On Battery operation the battery power has been completely exhausted and the UPS is waiting for utility power to return to normal.
Building Wiring Fault - Your building wiring presents a shock hazard that should be corrected by a licensed electrician.
WALL
FROM WALL JACK
DATALINE OUTPUT TO DSL,
MODEM, PHONE,
TO COMPUTER USB PORT
Status Visual Indicators Audible Indicators Alarm Terminates
Circuit
Breaker
AC Line
Cord
Building Wiring
Fault Indicator
Power LED - ON None n/a
Power LED - ON (off during beep)
Power LED - Flashing Rapid beeping (half-
Power LED - Flashing Constant tone UPS turned off with
Power LED - OFF Constant tone UPS turned off with
Power LED - OFF Beeping once every
Building Wiring Fault LED (red) - ON
OUTLET
DSL / MODEM /
FAX
DATA PORT
UPS Power
Indicator
Power
Power
Switch
When
Beeping 4 times every 30 seconds
second intervals)
4 seconds
None UPS is unplugged, or
UPS transfers back to On Line operation, or when UPS is turned off.
UPS transfers back to On Line operation, or when UPS is turned off.
the power switch.
the power switch.
Utility power is restored, or if utility power is not restored within 32 seconds, or the UPS is turned off.
plugged into a properly wired outlet.
990-2437A Copyright © 2007 American Power Conversion Corp.
See the Troubleshooting section for additional assistance.
APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
Troubleshooting
Use the table below to solve minor Back-UPS NS installation or operation problems. Consult APC Online Technical Support or call APC Technical Support for assistance with problems that cannot be resolved using the table below:
Problem Probable Cause Solution
Back-UPS NS will not turn on.
No power available at the Surge Protection outlets.
Connected equipment loses power.
The Power indicator is lit and the Back-UPS NS is beeping four times every 30 seconds.
The Power indicator flashes and the Back­UPS beeps twice per second at the same time.
Building Wiring Fault indicator is lit.
Battery is disconnected or utility power is not available at the wall outlet.
Surge Protection outlets have been overloaded.
Utility power not available at the wall outlet.
Equipment is connected to the “Surge Protection” outlets.
The Back-UPS NS is overloaded.
PowerChute Personal Edition software has performed a shutdown due to a power failure.
The Back-UPS NS has exhausted its available battery power.
Connected equipment does not accept the step­approximated sine waveform the Back-UPS NS.
The Back-UPS NS may require service.
The Back-UPS NS is using battery.
Battery capacity is low (about 2 minutes of use remaining).
Your building wiring presents a shock hazard. Using the Back-UPS with this condition will void the warranty.
Connect the battery (see Connect Battery) and ensure power is available at the wall outlet.
Reduce the amount of equipment plugged into Surge Protection outlets.
Ensure the fuse or circuit breaker for the outlet is not tripped, and that the wall switch controlling the outlet (if any) is in the ON position.
Ensure the equipment you want to stay powered during a power failure is plugged into the “Battery Backup plus Surge Protection” outlets and NOT the “Surge Protection” outlets.
Make sure the equipment plugged into the outlets of the unit are not overloading its capacity. Try removing some of the equipment and see if the problem continues.
The Back-UPS NS is operating normally.
The Back-UPS NS can only operate on battery power for a limited amount of time. The unit will eventually turn off when the available battery power has been used. Allow the unit to recharge for 16 hours before expecting maximum runtime.
The output waveform is designed for computers and computer-related equipment. It is not designed for use with motor-type equipment.
Contact APC Technical Support for further troubleshooting.
The Back-UPS NS is operating normally and using battery power. Once On Battery, you should save your current work, power down your equipment, and turn the unit OFF . Once normal power is restored, you may turn the unit back ON and power your equipment.
The Back-UPS NS is about to shut off due to a low battery charge condition! When the unit beeps twice every second, the battery has about 2 minutes of power remaining. Immediately power down your computer and turn the unit OFF. When normal power returns, the unit will recharge the battery.
Call a qualified electrician for service.
Inadequate runtime.
No phone/fax/DSL signal from the Back-UPS.
Internet connection is lost during power outage.
The battery is not fully charged. Battery is near the end of useful life.
Data line from the ISP or wall outlet is connected to the wrong jack on the Back-UPS.
Modem has lost AC Power.
Specifications
Model BN600
Input Voltage 120 Vrms Nominal
Frequency 50 - 60 Hz (auto-sensing) Brownout Transfer 88 Vrms, typical Over-voltage Transfer 139 Vrms, typical
Output UPS Capacity (4 outlets) 600 VA / 360 W
Total Amperage (8 outlets) 12 Amps (including UPS output) Voltage
On Battery Frequency - On Battery 50-60 Hz + Transfer Time 6 ms typical, 10 ms maximum
Protection and Filter AC Surge Protection Full time, 375 joules
Phone/fax/DSL Surge Protection
EMI/RFI Filter Full time AC Input Resettable circuit breaker
Battery Type Sealed, maintenance-free lead acid
Average Life 3 - 5 years depending on the number of discharge
Physical Net Weight 16.2 lb. (7.3 kg.)
Size 4.0” (H) x 11” (W) x 7.1” (D)
Operating Temperature Storage Temperature Operating Relative Humidity 0 to 95% non-condensing
Operating Elevation 0 to 10,000 ft (0 to 3,000m)
Safety/Regulatory Safety Approvals cTUVus, NOM-001
EMC Compliance Notice: This device complies with part 68 and
cycles and environmental temperature
part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
On the bottom of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company.
115 Vrms +
(step-approximated sine wave)
Single line (2-wire)
(10.2 x 27.9 x 18.03 cm)
o
F to 104oF (0oC to 40oC)
+32
o
F to 113oF (-15oC to 45oC)
+5
8%
1 Hz
Allow the unit to charge by leaving it plugged into the wall at least 16 hours. As a battery ages, the amount of runtime available will decrease. You can replace
the battery by ordering one at www.apc.com. Batteries also age prematurely if the Back-UPS NS is placed near excessive heat.
Make sure the data line from the wall outlet is connected to the jack labeled “Wall Outlet (Phone/Fax/DSL).
Plug the AC power cord of the modem into one of the four “Battery Back-up plus Surge Protection” outlets.
Order Replacement Battery
Replace with an APC qualified battery. Replacement batteries can be ordered from www.apc.com (valid credit card required). Have your Back-UPS NS model number available when ordering. Your model number can be found on the bottom of the unit.
Warranty
The standard warranty is 2 years from the date of purchase. APC’s standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to assigned asset tags and set depreciation schedules must declare such a need at first contact with APC Technical Support. APC will ship the replacement unit once the defective unit is received by the repair department or cross-ship upon the provision of a valid credit card number. The customer pays for shipping to APC, and APC pays ground freight transportation costs back to the customer.
Service
Please DO NOT RETURN Back-UPS NS to the place of purchase under any circumstances.
1. Consult the Troubleshooting section to eliminate common problems.
2. Verify the battery is connected (see Connect Battery) and that the Circuit Breaker is not tripped (see Troubleshooting section).
If you still have problems or questions, please contact APC via the internet or at one of the phone numbers listed below.
3. Before contacting APC, please be sure to record the date purchased, UPS model, and serial number (on bottom of unit).
4. Be prepared to troubleshoot the problem over the telephone with a Technical Support Representative. If this is not successful, the representative will issue a Return Material Authorization Number (RMA#) and a shipping address.
5. Pack the unit in its original packaging. If the original packaging is not available, ask APC Technical Support about obtaining a new set. Pack the unit properly to avoid damage in transit. Never use foam beads for packaging. Damage sustained in transit is not covered under warranty (insuring the package for full value is recommended).
6. Write the RMA# on the outside of the package.
7. Return the unit by insured carrier to the address given to you by APC Technical Support.
APC Contact Information
Online Technical Support: http://support.apc.com
http://www.apc.com/support
esupport@apcc.com Web Site: www.apc.com USA/Canada: 1.800.800.4272 Mexico: +52.292.0253 / 52.292.0255 Brazil: +0800.12.72.1 Worldwide: +1.401.789.5735
Loading...