The information presented in this manual is not warranted by APC by Schneider Electric to be authoritative,
error free, or complete. This publication is not meant to be a substitute for a detailed operational and site
specific development plan. Therefore, APC by Schneider Electric assumes no liability for damages, violations of
codes, improper installation, system failures, or any other problems that could arise based on the use of this
Publication.
The information contained in this Publication is provided as is and has been prepared solely for the purpose of
evaluating data center design and construction. This Publication has been compiled in good faith by APC by
Schneider Electric. However, no representation is made or warranty given, either express or implied, as to the
completeness or accuracy of the information this Publication contains.
IN NO EVENT SHALL APC BY SCHNEIDER ELECTRIC, OR ANY PARENT, AFFILIATE OR SUBSIDIARY
COMPANY OF APC by Schneider Electric OR THEIR RESPECTIVE OFFICERS, DIRECTORS, OR
EMPLOYEES BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL, OR
INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS,
CONTRACT, REVENUE, DATA, INFORMATION, OR BUSINESS INTERRUPTION) RESULTING FROM,
ARISING OUT, OR IN CONNECTION WITH THE USE OF, OR INABILITY TO USE THIS PUBLICATION OR
THE CONTENT, EVEN IF APC BY SCHNEIDER ELECTRIC HAS BEEN EXPRESSLY ADVISED OF THE
POSSIBILITY OF SUCH DAMAGES. APC BY SCHNEIDER ELECTRIC RESERVES THE RIGHT TO MAKE
CHANGES OR UPDATES WITH RESPECT TO OR IN THE CONTENT OF THE PUBLICATION OR THE
FORMAT THEREOF AT ANY TIME WITHOUT NOTICE.
Copyright, intellectual, and all other proprietary rights in the content (including but not limited to software, audio,
video, text, and photographs) rests with APC by Schneider Electric or its licensors. All rights in the content not
expressly granted herein are reserved. No rights of any kind are licensed or assigned or shall otherwise pass to
persons accessing this information.
This Publication shall not be for resale in whole or in part.
At least two (2) people are required to move and unpack this equipment.
Failure to follow these instructions can result in death, or serious injury.
1. Move the shipping pallet to a firm, level surface. Inspect the packaging for signs of shipping
damage. If you detect any shipping damage, contact Customer Support at www.apc.com.
2. Open the cardboard box and remove the four foam corner protectors.
3. With one person on each side of the cabinet, carefully lift the cabinet assembly out of the box and
set it on the floor.
NOTE: Save the packaging if you intend to re-ship the cabinet.
Please Recycle
The shipping materials are recyclable. Save them for later use, or dispose of them
appropriately.
1NetShelter WX Cabinet
Product Overview
Description
APC by Schneider Electric NetShelter
(EIA/ECA-310) 482 mm (19 in) rack-mount hardware, including voice, data, networking, and
inter-networking equipment.
NetShelter WX Cabinet
Rack
Model
AR100
AR100HD
†
One U= 44.45 mm (1.75 in)
Mounting
Height
13 U
This fully reversible unit has the following features:
• Storage height for 482 mm (19 in) rack-mount equipment
• Smoked, tempered glass front door (AR100) or fully vented front door (AR100HD)
• Solid rear door with keyholes for wall-mounting
• Locks on front and back doors
• Double hinge design provides front and rear access to installed equipment
• Adjustable front mounting rails with #12-24 tapped holes or square cage nut holes
• Fixed rear mounting rails with square cage nut holes
• Perforated side panel for side-to-side air flow.
Rack Mounting
Width
†
482 mm (19 in)584.2 mm (23 in)
™
Wall-mount cabinets provide storage for industry-standard
External cabinet
WidthDescription
Cabinet with glass door and
M6 tapped mounting rails
Cabinet with vented door and
M6 tapped mounting rails
Disclaimer
APC by Schneider Electric is not responsible for damage sustained during reshipment of this product.
NetShelter WX Cabinet2
Inventory
Verify the inventory
Unpack the cabinet. Verify that all required components and hardware have been shipped.
NOTE: If any items are missing, contact the shipper to file a report. Then contact APC by Schneider
Electric Customer Support at www.apc.com.
Component Identification
ns0526e
ItemDescriptionQtyItemDescription
12-24 x 1/2
combo pan head screws
M6 x 16 Phillips slot screws
M4 x 16 pan head screws
Keys
Cage nuts
Plastic cup washers
Rubber feet
Cage nut tool
30
30
4
2
30
30
4
1
Rear door locking rods
Hardware bag
Rubber feet
Front door
Vertical mounting rails
Removable access plate
Cable access hole covers
Rear door
3NetShelter WX Cabinet
Configuration
Before installing your cabinet, plan the location and arrangement of components within the cabinet
based on the available space.
Door locks
The front and back doors of the
unit have locks. The front door
uses a key lock , and the back
door uses two locking rods
that are accessible from the front
of the unit. Use a small flat tip
screwdriver to remove each
locking rod.
ns0527c
Cable access
The back door of the cabinet has eight (8) openings for cable
access: three (3) in the top of the door , one (1) in either side of
the door , and three (3) in the bottom of the door . Each
opening has an adjustable plastic cap for cable access.
For unrestricted access to the back of the cabinet when
the standard openings are insufficient, remove the six (6)
screws securing the access plate to the bottom of the rear
door.
ns0549a
ns0519a
NetShelter WX Cabinet4
Reversing the cabinet
You can reverse the cabinet to accommodate various configurations. Turn it over so that the doors open
in the opposite direction.
Mounting rails
This cabinet has square holes for using cage
nuts and round #12-24 tapped holes for screws.
You can reverse the front mounting rails to use
either set of holes. You can also adjust the depth
of the front rails to accommodate your
equipment.
See “Reverse the mounting rails” on page 6 and
“Adjust the depth of the front mounting rails” on
page 7.
Round holes
ns0528a
Square holes
ns0550a
5NetShelter WX Cabinet
Reverse the mounting rails
To reverse the front mounting rails, you must remove the locking rods, which are threaded through the
upper and lower holes in the rail on the lock side of the cabinet, as shown.
1. Each rod is held in place by a locking nut at the
back of the cabinet. Use a 10 mm wrench to hold
the nuts while you use a small flat tip screwdriver to
remove the locking rods.
2. Remove the rods from the cabinet.
3. Use a Phillips head screwdriver to remove
the screws at the top and bottom of both
rails.
4. Turn the rails over so that the upper and
lower holes are facing the front of the
cabinet.
5. Adjust the depth of the rails as required.
See step 2 and step 3 of “Adjust the depth
of the front mounting rails” on page 7.
6. Re-insert the locking rod through the holes
at the top and bottom of the rail. Use the
nuts to secure the locking rods in place.
Use a small flat tip screwdriver to lock the
rear door.
ns0538a
ns0568a
ns0569a
NetShelter WX Cabinet6
Adjust the depth of the front mounting rails
1. Use a Phillips head
screwdriver to remove
the screws in the front
mounting rail.
2. Reposition the mounting
rail to the front or back of
the cabinet in one of the
seven available
positions.
3. Replace and tighten the
screws in the highest
and lowest holes.
ns0552a
7NetShelter WX Cabinet
Installation
Assemble the Cabinet
TIP HAZARD
To prevent the unit from tipping or becoming unstable, install the rubber feet or securely
mount it to the wall before installing any components.
Failure to follow these instructions can result in death, serious injury, or equipment
damage.
Attach the rubber feet
1. Move the cabinet to a level location.
2. Close the back door .
3. Using a flat tip screwdriver, turn the
locking rods clockwise to lock the back
door .
4. Close the front door and secure it by
turning the handle clockwise.
WARNING
5. Lay the cabinet on its side.
6. Attach the rubber feet with the supplied
screws.
7. Set the cabinet upright.
ns0570a
ns0531a
NetShelter WX Cabinet8
Mount the Cabinet to a Wall
There are four keyhole cutouts on the back door that
will accommodate up to a 0.953 mm (3/8 in) bolt.
The holes are on standard 406.4 mm (16 in) centers
horizontally, and 533 mm (21 in) centers vertically.
Use the included template with a level to position the
cabinet properly.
406 mm (16 in)
Use appropriate fasteners to secure the cabinet to
the wall. For the weight of the cabinet and its
maximum weight capacity, see “Specifications” on
page 11.
Place Equipment in the Cabinet
For specific information on how to mount rack equipment in the cabinet, see the installation instructions
supplied with the equipment.
533 mm
(21 in)
ns0532a
NOTE: APC by Schneider Electric Uninterruptible Power Supply (UPS) products should be mounted in
the bottom of the cabinet. The UPS products will rest on the bottom cross-members of the cabinet.
Identifying one U-space
To install most equipment, you must locate the top and bottom
of a U-space on the mounting rails. This cabinet has square holes for
using cage nuts and round #12-24 tapped holes for screws. For the
cage nuts and the tapped holes, the narrower space above and below
each set of the three mounting holes indicates the top and bottom of a
U-space.
1 U
ns0444a
9NetShelter WX Cabinet
Installing equipment
1. Review the equipment manufacturer’s installation instructions.
2. Locate the top and bottom U-space on the mounting rails.
3. Install the cage nuts on the interior of the mounting rails, unless you are using the tapped holes.
Then install the equipment.
Cage nuts
CAUTION
FALLING EQUIPMENT
To ensure equipment installs securely, install cage
nuts with tabs engaging the left and right sides of the
square hole. Do NOT install cage nuts with tabs
engaging the top and bottom of the square hole.
Failure to follow these instructions can result in
injury or equipment damage.
ns1768a
To install a cage nut:
1. From the inside of the enclosure insert the cage nut into
the square hole by hooking a tab from one side of the
cage nut onto one side of the opening.
2. Place the cage nut tool onto the tab on the opposite side
of the cage nut and pull to snap it into position.
To remove a cage nut: Squeeze the tabs together to release.
gen0188a
NetShelter WX Cabinet10
Specifications
ItemMeasurement
Height662 mm (26.07 in)
Width584 mm (23.00 in)
Depth631 mm (24.86 in)
Maximum equipment depth482.60 mm (19.00 in)
Net weight42.73 kg (94.00 lb)
Equipment weight capacity90.9 kg (200.00 lb)
Ventilation (front door)143 870.70 mm
Ventilation (side panel)170 772 mm
Ventilation (glass front door)15 483.84 mm
Mounting space (without fan tray installed)13 U or 577.85 mm (22.75 in)
2
(223.00 in 2)
2
(264.6971 in2) of
perforated area X ~45.22% open
= 77 222.37 mm
2
(119.695in2)
2
(24.00 in 2)
11NetShelter WX Cabinet
Five-Year Factory Warranty
The limited warranty provided by APC by Schneider Electric in this Statement of Limited Factory
Warranty applies only to products you purchase for your commercial or industrial use in the ordinary
course of your business.
Terms of warranty
APC by Schneider Electric warrants its products to be free from defects in materials and workmanship
for a period of five years from the date of purchase. The obligation of APC by Schneider Electric under
this warranty is limited to repairing or replacing, at its sole discretion, any such defective products. This
warranty does not apply to equipment that has been damaged by accident, negligence, or misapplication
or has been altered or modified in any way. Repair or replacement of a defective product or part thereof
does not extend the original warranty period. Any parts furnished under this warranty may be new or
factory- remanufactured.
Non-transferable warranty
This warranty extends only to the original purchaser who must have properly registered the product. The
product may be registered at the APC by Schneider Electric Web site, www.apc.com.
Exclusions
APC by Schneider Electric shall not be liable under the warranty if its testing and examination disclose
that the alleged defect in the product does not exist or was caused by end user’s or any third person’s
misuse, negligence, improper installation or testing. Further, APC by Schneider Electric shall not be
liable under the warranty for unauthorized attempts to repair or modify wrong or inadequate electrical
voltage or connection, inappropriate on-site operation conditions, corrosive atmosphere, repair,
installation, start-up by non-APC by Schneider Electric designated personnel, a change in location or
operating use, exposure to the elements, Acts of God, fire, theft, or installation contrary to APC by
Schneider Electric recommendations or specifications or in any event if the APC by Schneider Electric
serial number has been altered, defaced, or removed, or any other cause beyond the range of the
intended use.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, BY OPERATION OF LAW OR
OTHERWISE, OF PRODUCTS SOLD, SERVICED OR FURNISHED UNDER THIS AGREEMENT OR
IN CONNECTION HEREWITH. APC BY SCHNEIDER ELECTRIC DISCLAIMS ALL IMPLIED
WARRANTIES OF MERCHANTABILITY, SATISFACTION AND FITNESS FOR A PARTICULAR
PURPOSE. APC BY SCHNEIDER ELECTRIC EXPRESS WARRANTIES WILL NOT BE ENLARGED,
DIMINISHED, OR AFFECTED BY AND NO OBLIGATION OR LIABILITY WILL ARISE OUT OF, APC
BY SCHNEIDER ELECTRIC RENDERING OF TECHNICAL OR OTHER ADVICE OR SERVICE IN
CONNECTION WITH THE PRODUCTS. THE FOREGOING WARRANTIES AND REMEDIES ARE
EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES. THE WARRANTIES
SET FORTH ABOVE CONSTITUTE APC BY SCHNEIDER ELECTRIC’S SOLE LIABILITY AND
PURCHASER'S EXCLUSIVE REMEDY FOR ANY BREACH OF SUCH WARRANTIES. APC BY
SCHNEIDER ELECTRIC WARRANTIES EXTEND ONLY TO PURCHASER AND ARE NOT
EXTENDED TO ANY THIRD PARTIES.
IN NO EVENT SHALL APC BY SCHNEIDER ELECTRIC, ITS OFFICERS, DIRECTORS, AFFILIATES
OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL, CONSEQUENTIAL OR
PUNITIVE DAMAGES, ARISING OUT OF THE USE, SERVICE OR INSTALLATION, OF THE
PRODUCTS, WHETHER SUCH DAMAGES ARISE IN CONTRACT OR TORT, IRRESPECTIVE OF
FAULT, NEGLIGENCE OR STRICT LIABILITY OR WHETHER APC BY SCHNEIDER ELECTRIC HAS
BEEN ADVISED IN ADVANCE OF THE POSSIBLY OF SUCH DAMAGES. SPECIFICALLY, APC BY
SCHNEIDER ELECTRIC IS NOT LIABLE FOR ANY COSTS, SUCH AS LOST PROFITS OR
REVENUE, LOSS OF EQUIPMENT, LOSS OF USE OF EQUIPMENT, LOSS OF SOFTWARE, LOSS
OF DATA, COSTS OF SUBSTITUENTS, CLAIMS BY THIRD PARTIES, OR OTHERWISE.
NetShelter WX Cabinet12
NO SALESMAN, EMPLOYEE OR AGENT OF APC BY SCHNEIDER ELECTRIC IS AUTHORIZED TO
ADD TO OR VARY THE TERMS OF THIS WARRANTY. WARRANTY TERMS MAY BE MODIFIED, IF
AT ALL, ONLY IN WRITING SIGNED BY AN APC BY SCHNEIDER ELECTRIC OFFICER AND
LEGAL DEPARTMENT.
Warranty claims
Customers with warranty claims issues may access the APC by Schneider Electric customer support
network through the Support page of the APC by Schneider Electric Web site, www.apc.com/support.
Select your country from the country selection pull-down menu at the top of the Web page. Select the
Support tab to obtain contact information for customer support in your region.