APC 120 V, 15A, G5BLK User Manual

Installation and
Operation
G-Type Rack Power Filter
G5BLK
120V
15A
General Information ....................................................... 1
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation ...................................................................... 3
Install the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Connect A/C Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Operation ........................................................................ 5
Display Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Configuration .................................................................. 9
Troubleshooting .......................................................... 10
Common problems and solutions . . . . . . . . . . . . . . . . . . . . . . . . . .10
Contact APC APV Technical Support . . . . . . . . . . . . . . . . . . . . . . .10
Specifications ............................................................... 11
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Español ......................................................................... 13
Français (Canada) ........................................................ 25
APC A/V G-Type Rack Power Filter
i
ii
APC A/V G-Type Rack Power Filter

General Information

Overview

The APC® AV G-Type Rack Power Filter protects high-performance audio and video system equipment from damage due to power surges, spikes, and lightning strikes.

Inventory

Power conditioner (1) Stabilizing feet (4)

Safety

Electrical Hazard: For indoor use only.
CAUTION - Do not install this device if there is not at least 10 meters (30 feet) or more of wire between the electrical outlet and the electrical service panel.
Risk of electric shock. Do not plug into another relocatable power tap.
Contains always on receptacles. To reduce the risk of electric shock, disconnect the unit from the power source before servicing the equipment.
Overloading. Do not overload the wall outlet where this device is being connected. Do not overload this device. Ensure the total load to this device does not exceed that which is listed in the Specifications section of this manual.
Power. Ensure this device is connected to a properly grounded AC power source. Further ensure the device is plugged into a source providing the required 120 Vac. Do not use a plug adapter which defeats the ground pin of the AC plug.
Placement. Do not install this device on any unsteady surface. Do not install this device on any heat source.
Water and Moisture. Do not use this product near any source of water, or in an environment where the relative humidity may exceed 95% (non-condensing)
Polarization. This device has a polarized AC line plug having one grounding pin. This plug will only fit into the wall outlet in one orientation. This is a safety feature. Do not remove the round grounding pin.
System Ground Terminal. The unit provides for the connection of grounding wires from all of your equipment to a central terminal lug. This ground connection eliminates ground loop problems; tie all component grounds to this screw to break any possible ground loops that can cause an audible noise.
Servicing. There are no user-serviceable components within this device. Removal of the cover from this device may present a shock hazard, and/or void the warranty.
Damage Requiring Service. If any type of damage occurs to this device, immediately disconnect it from the wall outlet. Notify APC Technical Support or Customer Service at once.
Replacement Parts. There are no components within this device that can or should be removed/replaced unless it is by an APC-qualified technician.
1APC A/V G-Type Rack Power Filter: General Information

Components

Front view

Circuit breakerLCD Display
ALWAYS ON outlet
DOWN button
UP button
Power button
SETUP button
STATUS button
LED Indicators:
•POWER ON
•LINE OK
ROTECTION
•P
ORKING
W
•WIRING OK
VERLOAD
•O
•DELAYS 1-4
•S
WITCHED
•ALWAYS ON

Rear view

System Ground
ALWAYS ON outlets
SWITCHED outlet DELAY 1 outlet
DELAY 2 outlets
DELAY 3 outlet
DELAY 4 outlet
av005a
APC A/V G-Type Rack Power Filter: General Information2

Installation

Install the Unit

Install the unit on a flat surface

The unit may be installed on any flat surface capable of supporting at least 27.3 kg (60 lbs).
Remove the mounting brackets.
Attach the stabilizing feet.
placing it on a flat surface to avoid scratching the surface and to protect the unit.

Install the unit in a rack or enclosure

Use four screws to secure the mounting brackets to the rails in the rack or enclosure.
Attach the stabilizing feet (included) to the bottom of the unit before

Connect A/C Power

Connect the unit to A/C power

Note: If the unit is connected to A/C power, the unit is actively monitoring input power, but is
operating in Standby mode.
Use the A/C power cord to connect the unit to A/C power. If the unit is functioning properly, the display will illuminate.

Connect components to the unit

Before connecting components to the unit, determine which components will utilize the ALWAYS ON outlets, the SWITCHED outlet, and the DELAY outlets. Then, connect components to the outlets on the back panel of the unit.
3APC A/V G-Type Rack Power Filter: Installation
Always On outlets. The ALWAYS ON outlets supply power to the connected components, even if the
unit is turned off. If A/C power is lost, and then re-applied to the unit, components connected to the
ALWAYS ON outlets will turn on immediately, as power will be supplied to them immediately.
Switched outlet. The SWITCHED outlet supplies power to the connected equipment while the unit is on.
If the unit shuts off, it will not supply power to equipment connected to the power is lost, and then re-applied to the unit, equipment connected to the
SWITCHED outlet. If A/C
SWITCHED outlet will turn on
immediately.
Delay outlets. The unit has five delayed outlets. When the unit is turned on, power is immediately
applied to the the unit was off). Then, power is applied to each of the through
SWITCHED outlet (power was already being supplied to the ALWAYS ON outlets, even though
DELAYED outlets in sequence, DELAY 1 first,
DELAY 4.
When the unit is turned off, power is disconnected from the delayed outlets in reverse order.
Use the display interface to customize the delay times.
APC A/V G-Type Rack Power Filter: Installation4

Operation

Display Interface

Using the display interface

Use the display interface on the front of the G5BLK to configure and operate the unit.
Power. Push to apply power to the unit or to shut off power to the unit.
Status. Push to display the current status of the unit, including the current input/output voltage.
Setup. Push to scroll through the setup menus.
Up/Down. Push to change values (Setup menu) and browse menu pages (Status menu).

Display interface LEDs

There are eleven LEDs on the display interface.
LED Illuminated Not Illuminated
POWER ON
LINE OK
PROTECTION
ORKING
W
WIRING OK
OVERLOAD
DELAY 1 DELAY 2 DELAY 3
ELAY 4
D SWITCHED
ALWAYS ON
The unit is supplied with utility power.
The utility power is within acceptable range, 92 V to 140 V.
The unit is protecting all connected equipment.
The unit is functioning properly. There is a problem with the building wiring. Contact a
The unit is overloaded. Disconnect some connected components. Contact APC Technical Support.
Power is being supplied to DELAY1. Power is not being supplied to DELAY1. Power is being supplied to DELAY2. Power is not being supplied to DELAY2. Power is being supplied to DELAY3. Power is not being supplied to DELAY3. Power is being supplied to DELAY4. Power is not being supplied to DELAY4. Power is being supplied to the
SWITCHED outlet.
Power is being supplied to the
ALWAYS ON outlets.
There is no input utility power.
The input voltage from utility power is outside the acceptable range and the unit has disconnected from utility power to protect the connected equipment.
The unit is not providing power protection. See Troubleshooting and contact APC Technical Support immediately.
certified electrician. The unit is functioning properly.
Power is not being supplied to the
Power is not being supplied to the See “Troubleshooting” on page 10 and contact APC Technical Support immediately.
SWITCHED outlet.
ALWAYS ON outlets.
5APC A/V G-Type Rack Power Filter: Operation

Status menu

Note: The menus shown in this manual are for reference only. Information displayed on the
unit may be different than shown here.
Utility Source, Voltage and Frequency.
Current and Percentage.
Contact Information.
Model and Serial Number.
Firmware version.
UTILITY SOURCE 120V 60Hz
TOTAL OUTPUT 12A 80%
1-888-8827228 WWW.APCAV.COM
G5 POWER FILTER SN: AB1234567890
FW REVISION:
860.M1.D
Recent Faults.
NO FAULT
FAULT CONDITION
Description

Setup menu

Note: The menus shown in this manual are for reference only. Information displayed on the
unit may be different than shown here.
Use the Setup menus to configure the unit. There are nine setup menus. Push menu.
LCD dimmer. Set the brightness of the display.
DISPLAY DIMMER: NORMAL
SETUP to scroll to the next
APC A/V G-Type Rack Power Filter: Operation6
LED dimmer. Set the brightness of the LED.
LED DIMMER: DIM1
Delay1. Select the number of seconds for the delay.
DELAY 1: 4SEC (1-60)
Delay2. Select the number of seconds for the delay.
DELAY 2: 4SEC (1-60)
Delay3. Select the number of seconds for the delay.
DELAY 3: 4SEC (1-60)
Delay4. Select the number of seconds for the delay.
DELAY 4: 4SEC (1-60)
Cut-Off Voltage. Select the maximum and minimum voltage. The unit will protect connected
equipment from high and low voltages that are not safe for operation.
MAX UPPER VOLT: 140V (132-140)
MIN LOWER VOLT: 92V (92-100)
Language. Select the language for the display: English, French, or Spanish. Push SETUP to go to the
next screen,
RESET TO DEFAULT.
MENU LANGUAGE: ENGLISH
Restore default settings. Select YES or NO to restore the default settings.
RESET TO DEFAULT YES

Lock the unit

The unit can be locked to prevent unwanted access. To lock or unlock the unit, push STATUS and DOWN for three seconds.
G5BLK LOCKED
7APC A/V G-Type Rack Power Filter: Operation

Save screen as default

To save a screen as the default, push STATUS for three seconds.
THIS SCREEN IS SAVED AS DEFAULT

Shut down the unit

Push and hold the POWER button.
POWERING DOWN
APC A/V G-Type Rack Power Filter: Operation8

Configuration

Configure the unit

Select a language. Push the SETUP button until the Language menu is displayed. Select English,
French, or Spanish.
Configure the brightness of the display. To alter the brightness of the LCD display screen, push
SETUP one time and select a numerical value, one through seven.

Configure the sequence delay outlets

Configure the delay options so that the DELAY outlets apply power in sequence, instead of all at one time.
SETUP until the delay menu screen appears. Use the UP and DOWN buttons to change the number of
Push seconds of delay. When finished, push

View status of the unit

Push the STATUS button until the input source voltage and frequency screen appears.
SETUP again to move to the next delay screen.
Push the
You can also view APC Technical Support contact information, the model and serial number of the unit, the firmware version, and the last three faults registered by the unit using the
STATUS button to display the output current and percentage.
STATUS menus.
9APC A/V G-Type Rack Power Filter: Configuration
Loading...