STANDARD VENT
Residential Gas Water Heaters
®
300/301 Series
FEATURES
SIDE-MOUNTED RECIRCULATING TAPS
For installation with combination space heating/potable water heating applications
(such as ProMax XL, Heat Exchanger) or any system requiring a recirculating hot water loop.
INTELLIGENT CONTROL LOGIC
The internal microprocessor provides enhanced operating parameters and tighter differentials for
precise sensing and faster heating response to optimize performance.
SELF-POWERED ELECTRONIC GAS VALVE
Uses a thermopile to generate the power needed to operate the electronic gas control without
requiring an external power source.
DIAGNOSTICS
The electronic gas control incorporates an LED status indicator that monitors system operation
& service diagnostics.
DYNACLEAN™ II AUTOMATIC SEDIMENT-CLEANING SYSTEM
Specially designed dip tube directs incoming cold water to create turbulence in the tank, to reduce lime
and sediment buildup. DynaClean™ II helps maximize tank life, maintain high energy-efficiency and
increases hot water output. Made from long-lasting PEX cross-linked polymer.
GREEN CHOICE® GAS BURNER
Patented “Eco-Friendly” design reduces NOx emissions by up to 33% and complies with requirements
for low NOx emissions.
COREGARD™ ANODE RODS
A. O. Smith’s exclusive aluminum anodes have a stainless steel core, protects tank against
corrosion longer.
PUSH-BUTTON PIEZO IGNITOR
Makes lighting pilot fast and easy with one-hand push-button spark ignition.
®
HEAT TRAP NIPPLES
Standard on all models.
DURABLE, TAMPER-RESISTANT BRASS DRAIN VALVE
“ENVIRONMENTALLY-FRIENDLY” NON-CFC FOAM INSULATION
Improves efficiency.
BLUE DIAMOND® GLASS COATING
Provides superior corrosion resistance compared to industry-standard glass lining.
CSA CERTIFIED AND ASME RATED T&P RELIEF VALVE
Top-mounted T&P relief valve available as an option.
FVIR COMPLIANT
See other side.
CODE COMPLIANCE
Meets UBC, CEC, SBCC, HUD and BOCA National Codes. Meets the thermal efficiency and standby
loss requirements of the U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1
and meets the Federal Energy Efficency Standards effective January 20, 2004, according to the
National Appliance Energy Conservation Act (NAECA) of 1992.
DESIGN-CERTIFIED BY CSA INTERNATIONAL
According to ANSI Z21.10.1 - CSA 4.1 Standards governing storage-type water heaters.
10-YEAR LIMITED TANK AND PARTS WARRANTY
For complete information, consult written warranty or A. O. Smith Water Products Company.
®
Low Lead Content
Page 1 of 2
AOSRG46101
Residential Gas Water Heaters
®
STANDARD VENT
FIRST
MODEL
NUMBER
10-YEAR LIMITED TANK AND PARTS WARRANTY
XGV-40L 70 .63 40 40,000 30,400 41 16 61-3/4
XGV-50L 88 .62 50 40,000 30,400 41 16 61 57-1/4 22 13 8 50-1/2 14-1/4 50-1/2 3 or 4 165
Recovery capacity based on actual performance tests.
† Propane Gas – XGV-40L: 36,000 BTU; XGV-50L: 37,000 BTU
HOUR
RATING
GALLONS
ENERGY
FACTOR
GALLON
CAPACITY
BTU
INPUT
PER HOUR
NATURAL
BTU
OUTPUT
PER HOUR
†
NATURAL
RECOVERY
90ºF RISE
GALLONS
PER HOUR
R
VALUE
A B C D E F G H
Flammable Vapor Ignition
Resistant (FVIR) Water Heaters
A. O. Smith FVIR design meets the American National Standards Institute standards
(ANSI Z21.10.1 - CSA 4.1 Standards) that deal with the accidental or unintended
ignition of flammable vapors, such as those emitted by gasoline.
Feature a sealed combustion chamber with air intake filter and a flame arrestor
built into the water heater base. In addition, a thermal cutoff (TCO) device, is
designed to shut off gas flow to the burner and pilot if poor combustion is detected.
DIMENSIONS IN INCHES
58-1/4
20 13 8 51-3/4 14-1/4 51-3/4 3 or 4 150
ANODE ROD
(OPTIONAL T&P
LOCATION)
HOT
CONNECTION
300/301 Series
APPROXIMATE
DRAFT
HOOD
OUTLET
COLD
CONNECTION
E
C
SHIPPING
WEIGHT
(LBS)
T&P VALVE
A
B
1/2" GAS
CONNECTION
D
If flammable vapors accidentally enter the
combustion chamber, the arrestor is designed
so flames burn off the top surface and can not
escape down through the arrestor.
A. Industry standard thermopile
B. Large View Port for easy burner inspection
0
C. 360
combustion air filter
D. Thermal Cutoff (TCO) with manual reset
For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
Maximum hydrostatic working
pressure: 150 psi
www.hotwater.com
F
Page 2 of 2
AOSRG46101