SAFE INSTALLATION, USE AND SERVICE
Your safety and the safety of others is extremely important in the installation, use, and servicing of this water heater.
Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who install, use, or service this water heater.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
DANGER indicates an imminently hazardous
DANGER
WARNING
CAUTION
CAUTION
situation which, if not avoided, will result in death or injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, could result in property damage.
All safety messages will generally tell you about the type of hazard, what can happen if you do not follow the safety message, and how to avoid the risk of injury.
The California Safe Drinking Water and Toxic Enforcement Act requires the Governor of California to publish a list of substances known to the State of California to cause cancer, birth defects, or other reproductive harm, and requires businesses to warn of potential exposure to such substances.
WARNING: This product contains a chemical known to the State of California to cause cancer, birth defects, or other reproductive harm.
This appliance can cause low-level exposure to some of the substances listed in the act.
Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and can ignite when exposed to a spark or flame. To prevent the possibility of injury under these conditions, we recommend the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance which is connected to the hot water system. If hydrogen is pres­ent, there will probably be an unusual sound such as air escaping through the faucet as water begins to flow. Do not smoke or have any open flame near the faucet at the time it is open.
IMPORTANT DEFINITIONS
Qualified Installer: A qualified installer must have ability equivalent to a licensed tradesman in the fields of plumbing and electrical installation of these appliances. This would include a thorough understanding of the requirements of the National Electrical Code and applicable local electrical and plumbing codes (and tools necessary to confirm proper installation and operation of the water heater) as they relate to the installation of electric water heaters. The qualified installer must have a thorough understanding of the water heater Instruction Manual.
Service Agency: A service agency also must have ability equivalent to a licensed tradesman in the fields of plumbing and electrical installation of these appliances. This would include a thorough understanding of the requirements of the National Electrical Code and applicable local electrical and plumbing codes (and tools necessary to confirm proper installation and operation of the water heater) as they relate to the installation of electric water heaters. The service agency must have a thorough understanding of the water heater Instruction Manual.
2
GENERAL SAFETY
3
INTRODUCTION
Thank You for purchasing this water heating system.
Properly installed and maintained, it should give you years of trouble free service.
Abbreviations Found In This Instruction Manual:
• ANSI - American National Standards Institute
• ASME - American Society of Mechanical Engineers
• GAMA - Gas Appliance Manufacturers Association
• NEC - National Electrical Code
• NFPA - National Fire Protection Association
• UL - Underwriters Laboratories Inc.
• SRCC - Solar Rating and Certification Corp.
SYSTEM DESCRIPTION
This Solar Water Heating System consists of four main parts — the solar collectors, the solar pump station, the solar storage tank, and the plumbing for the heat transfer
uid.
The solar pump station uses a pump to circulate a heat-
transfer uid through the “collector loop”. This collector loop includes the solar collectors, the uid lines or “line­set” and a heat exchanger. The collector loop is a “closed loop”, meaning there is no contact of the heat transfer uid
with your potable water or with the atmosphere. The collec-
tor loop contains only a small volume of heat-transfer uid
which is non-toxic and freeze-protected to -30°F (Freeze tolerance limits are based upon an assumed set of environ­mental conditions). Though freeze protection may not be
necessary in all areas, the heat-transfer uid also contains
corrosion inhibitors which protect the system components, has an elevated boiling point, and is suitable throughout North America.
When exposed to sunlight, the solar collectors get hot.
As the heat-transfer uid passes through the collectors,
it absorbs the heat and then travels down the line-set to
the tank. The hot uid passes through the heat exchanger
and heat is transferred to the potable water. After giving up
its heat to the potable water, the cool heat-transfer uid is
pumped back to the solar collectors to be heated again. Hot potable water is stored in the solar storage tank.
The auxiliary or back-up electric-heating guarantees hot water even under poor solar conditions (at night or when very cloudy). The minimum acceptable temperature set-
point is specied in local plumbing codes.
You can save the most money on your water-heating bills by using the backup heater on your system as little as pos­sible. If the sun shines brightly between 10 am and 3 pm, enough heat will normally be generated to keep the water hot throughout the rest of the day and night.
However, on days when the sky is cloudy or when large quantities of hot water are being used, we recommend leaving the backup heater turned on and set to 120° F to provide adequate hot water.
PREPARING FOR THE INSTALLATION
1. Read the “General Safety” section of this manual first and
then the entire manual carefully. If you don’t follow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY, AND/ OR PROPERTY DAMAGE.
This manual contains instructions for the installation,
operation, and maintenance of the solar water heater. It also contains warnings throughout the manual that you must read and understand. All warnings and all instructions are essential to the proper operation of the water heater and your safety. READ THE ENTIRE
MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.
2. The installation must conform with these instructions and the local code authority having jurisdiction and the requirements of the power company. In the absence of local code requirements follow NFPA-70, the National Electrical Code (current edition), which may be ordered from: National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169.
3. If after reading this manual you have any questions or do not understand any portion of the instructions, call the local utility or the manufacturer whose name appears on the rating plate.
4. Carefully plan your intended placement of the water heater and collectors. INSTALLATION OR SERVICE OF THIS WATER HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED. PLUMBING AND ELECTRICAL WORK ARE REQUIRED.
Examine the location to ensure the water heater complies
with the “Facts to Consider About the Location” section
in this manual.
5. For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an earthquake. See instructions for correct installation procedures. Instructions may be obtained from California Office of the State Architect, 400 P Street, Sacramento, CA 95814.
6. Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR
2.00: State Plumbing Code and 248-CMR 5.00.
7. The solar energy system described by this manual, when properly installed and maintained, meets the minimum standards established by the SRCC. This certification does not imply endorsement or warranty of this product by SRCC.
4
TABLE OF CONTENTS
SAFE INSTALLATION, USE AND SERVICE............................. 2
Important Denitions .................................................. 2
GENERAL SAFETY ..................................................................3
INTRODUCTION ...................................................................... 4
System Description .................................................... 4
Preparing for Installation ............................................. 4
TABLE OF CONTENTS ............................................................ 5
SYSTEM DIAGRAM/TYPICAL INSTALLATION ....................... 6
SYSTEM COMPONENT PART ................................................ 7
STORAGE TANK INSTALLATION ............................................ 7
Local Codes ............................................................... 7
Temperature-Pressure Relief Valve ........................7-8
Closed System/Thermal Expansion ............................ 8
Locating the Solar Water Heater ................................ 8
Water Piping ............................................................8-9
Installation in Residential Garages.............................. 9
Filling the Solar Water Heater with Water ...................9
Wiring of Element ..................................................... 10
Thermostat ............................................................... 10
Temperature Regulation ...................................... 10-11
Temperature Settings ............................................... 11
Temperature Adjustment .......................................... 11
Tank Sensor ............................................................. 11
Draining ............................................................... 11-12
Element .................................................................... 12
Element Replacement .............................................. 12
Anode ....................................................................... 12
Water Heater Sounds ...............................................12
SOLAR COLLECTOR INSTALLATION ..................................13
Collector Location .................................................... 13
General Considerations ........................................... 13
Collector Orientation ...........................................13-14
Spanner Mounting ............................................... 15-17
Attaching Collector to Mounting Brackets ................ 18
Collector Piping ........................................................ 19
Collector Piping Detail .............................................. 20
Sensor Wiring at Collector ....................................... 20
Sensor Mounting at Collector ................................... 20
Piping Through the Roof .......................................... 20
Piping Insulation ....................................................... 20
PUMP STATION INSTALLATION ........................................... 21
Pump Station ............................................................ 21
Safety Instructions .................................................... 21
Safety Equipment ..................................................... 22
Wall Mounting the Solar Pump Station .................... 22
Plumbing Conguration ............................................ 23
Function ................................................................... 23
Flowmeter ................................................................ 23
Start-up and Operation of the Solar Pump Station ... 24
Leak Detection ......................................................... 24
Flushing .................................................................... 24
Filling ........................................................................ 24
Preparation of the Heat Transfer Fluid ..................... 24
Filling the Solar Loop ...........................................24-25
Draining ..................................................................... 25
PUMP STATION CONTROL INSTRUCTIONS ....................... 26
Control Instructions .................................................. 26
System Description ............................................. 26-33
TROUBLESHOOTING ......................................................34-36
SYSTEM MAINTENANCE ...................................................... 37
REPAIR PARTS ...................................................................... 38
HEAT TRANSFER FLUID PROPERTIES .............................. 39
SOLAR RATING / MODELS / WARRANTY.......INSERT SHEET
5
SYSTEM DIAGRAM/TYPICAL INSTALLATION
10
6
VACUUM RELIEF
VALV E
INSTALL THERMAL EXPANSION
TANK IF WATER HEATER IS
INSTALLED IN A CLOSED
WATER SYSTEM
INSTALL PER
LOCAL CODES
1 1
8
2
Discharge Pipe
(DO NOT CAP
OR PLUG)
Metal Drain
Pan
10
At Least 2” Greater Than The
Diameter Of The Water Heater.
11
5
4
9
3
7
6” Maximum Air Gap
Flow Direction
Piped To An Adequate Drain
INSTALL VACUUM RELIEF IN COLD WATER INLET LINE AS REQUIRED BY LOCAL CODES.
INSTALL THERMAL EXPANSION TANK OR DEVICE IF WATER HEATER IS INSTALLED IN A CLOSED WATER SYSTEM.
Figure 1.
6
INSTALL SUITABLE METAL DRAIN PANS UNDER HEATERS TO PREVENT DAMAGE DUE TO LEAKAGE. REFER TO WATER HEATER LOCATION, SEE “LOCATING THE SOLAR WATER HEATER” SECTION.
SYSTEM COMPONENT PART
Item Component Function
1 Solar collector Absorbs the sun’s heat energy and transfers this to the heat transfer
uid circulating through the collector.
2 Solar storage tank Stores potable water heated by solar generated heat or installed
back-up electric resistance element.
3 Double Wall Heat exchanger (inside
Solar pump station)
4 Solar Loop Expansion tank Allows for the expansion and contraction of the heat transfer uid as
5 Temperature and Pressure relief
valve
6 Air vent Purges air from the collector loop uid during the installation.
7 Drain valve Used to drain the heat transfer uid from the collector loop.
8 Mixing valve Used to temper hot water from the solar storage tank with cold inlet
9 Solar pump station Controls the ow of heat transfer uid from the collectors to the tank
10 Temperature sensor Tank and collector sensor work together to turn the circulating
11 Cold Water Cut-Off Valve Isolates the tank from incoming water supply.
Transfers the heat from the collector loop to the potable water in the solar storage tank.
it heat and cools.
Required by plumbing code to automatically open and dump water if the storage tank exceeds 150 PSI of pressure or 210° F in tempera­ture.
water to maintain appropriate temperature hot water delivered from the system.
through the heat exchanger. For a detailed description of the solar pump station see page 20.
pump(s) on and off at preset temperature differentials.
STORAGE TANK INSTALLATION
Never operate the electrical heating element without being certain the solar water heater is completely filled with water. If any air is left in the top of the tank, the heating element
will burn out.
LOCAL CODES
The installation of this solar water heater must be in accordance with these instructions and all applicable local codes and electric utility requirements. In the absence of local codes, install in accordance with the latest edition of the
National Electrical Code (NFPA-70).
TEMPERATURE-PRESSURE RELIEF VALVE
For protection against excessive pressures and temperatures in this water heater, install temperature-pressure protective equipment required by local codes, but not less than a combination temperature-pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves for Hot Water Supply Systems, the latest edition of ANSI Z21.22. This valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 lbs./sq. in.).
Install the temperature-pressure relief valve directly into the fitting of the water heater. Position the valve downward and provide a discharge pipe that must terminate a maximum
of six inches above a oor drain or external to the building.
In cold climates, it is recommended that the discharge pipe be terminated at an adequate drain inside the building. Be certain that no contact is made with any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. Excessive length, over 15 feet, or use of more than two elbows can cause restriction and reduce
the discharge capacity of the valve.
No valve or other obstruction is to be placed between the temperature-pressure relief valve and the tank. Do not
connect tubing directly to discharge drain unless a 6” air
gap is provided. To prevent bodily injury, hazard to life or damage to property, the temperature-pressure relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.
The Discharge Pipe:
• Shall not be smaller in size than the outlet pipe size of the
temperature-pressure relief valve, or have any reducing couplings or other restrictions.
• Shall not be plugged or blocked.
• Shall be of material listed for hot water distribution.
• Shall be installed so as to allow complete drainage of both the
temperature-pressure relief valve, and the discharge pipe.
• Must terminate a maximum of six inches above a floor drain
7
or external to the building. In cold climates, it is recommended that the discharge pipe be terminated at an adequate drain inside the building.
• Shall not have any valve between the relief valve and tank.
When installing the temperature-pressure relief valve, use two or three turns of Teflon® tape or other suitable thread sealer around the threaded end of the valve.
Figure 2.
The temperature-pressure relief valve should be manually opened once a year. Caution should be taken to ensure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot.
If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one.
If the temperature-pressure relief valve on the appliance
weeps this may be due to thermal expansion. The water supply serving this solar water heater may have a check valve installed. Contact the water supplier or local plumbing contractor on how to control this situation. Do not plug the temperature-pressure relief valve.
CLOSED SYSTEM/THERMAL EXPANSION
As water is heated, it expands (thermal expansion). In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This type of failure is not covered under the limited warranty. Thermal expansion can also cause intermittent temperature­pressure relief valve operation: water discharged from the valve due to excessive pressure build up. The temperature­pressure relief valve is not intended for the constant relief of thermal expansion. This condition is not covered under the limited warranty.
A properly-sized thermal expansion tank should be installed on all closed systems to control the harmful effects of thermal expansion. Contact a plumbing service agency or your retail supplier regarding the installation of a thermal expansion tank..
LOCATING THE SOLAR WATER HEATER
If you have a choice of where to install the solar water heater, these ideas may help you decide.
1. Put the solar water heater indoors as close as possible to where you use the most hot water. This water heater
is not intended for outdoor installation.
2. It is handy to have a floor drain, tub or sink nearby. That will make it easy to drain water from the water heater. It is also a good place to end the drain line of the temperature-pressure relief (T & P) valve.
3. The solar water heater or the pipes and the connections may, in time, leak. Put the solar water heater in a place where a water leak will not damage anything.
4. You must not put the water heater in an area where it might freeze You must turn off the electricity to the water heater before you drain it, to protect the heating elements.
5. Make sure that you are able to reach the drain valve and all access panels when the water heater is in place. This will make it easy to service the water heater.
6. The water heater must be level before you begin the piping.
WATER HEATERS EVENTUALLY LEAK. The installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will not cause damage to the area adjoining the water heater or to lower floors of the structure. When such locations can’t be avoided, a suitable metal drain pan should be installed under the water heater. Such a pan should be no greater than 1 1/2 inches deep, have a minimum length and width of at least two inches greater than the heater dimensions and must be piped to an adequate drain.
This solar water heater, as all water heaters, will eventually leak. Do not install without adequate drainage provisions where water flow will cause damage. Note: normal condensation from a solar water heater may appear to be a leaking tank.
WATER PIPING
This solar water heater is design certified to be used with a potable water system. When connecting water piping with solder joints use only lead free solder.
This solar water heater shall not be connected to any heating systems or component(s) previously used with a non-potable water heating appliance.
If this solar water heater is also used for space heating applications, all piping and components connected to the solar water heater shall be suitable for use with potable water.
This appliance has been design certified as a solar water heater complying with Standards for Safety - UL174 for the U.S. and can/csa-c22.2 No 110 F379.1 and F379.2
8
for Canada. The particular application of this appliance described (above paragraph) may be subject to review and approval by local code officials.
Toxic chemicals such as used for treatment of boilers or non­potable water heating appliances shall never be introduced into a potable water space heating system.
Figure 3.
The solar water heater will work better if you keep the hot water runs short. You will also get hot water faster and with less heat loss.
The illustration shows the correct valves and fittings that you
will need to install the solar water heater. Threaded (3/4”)
water connections are supplied through the tank top.
d. The cold water supply line must have a shut-off valve
and union.
4. Use a union to connect the hot water supply pipe to the
solar water heater’s hot water outlet.
Operating an empty or partially filled solar water heater will result in damage to the tank.
If a solar water heater is installed in a closed water system; such as one having a back flow preventer, check valve or water meter with check valve in the cold water supply line, means shall be provided to control thermal expansion. Contact the water supplier or local plumbing contractor on
how to control this situation.
INSTALLATION IN RESIDENTIAL GARAGES
The solar water heater must be located and/or protected so it is not subject to physical damage by a moving vehicle.
FILLING THE SOLAR WATER HEATER WITH WATER
HOT WATER OUTLET
MIXING VALVE
TEMPERED
WATER
OTLET
TEMPERATURE-PRESSURE
RELIEF VALVE
DRAIN LINE
TOP SOLAR WATER
LOOP CONNECTIONS
ACCESS COVER
COLD WATER
INLET
SIDE SOLAR
WATER LOOP
CONNECTIONS
Figure 4.
1. Buy the fittings that you need to connect the pipes. Remember that you have to connect both the hot and cold water pipes.
2. Apply a light covering of pipe joint compound to each outside thread before making connection.
3. Connect the cold water supply pipe to the cold water inlet of your solar water heater as follows:
a. Look at the top cover of the solar water heater. The
hot and cold connections are marked there.
b. A non-metallic dip tube is supplied to carry cold water
from the tank top to the bottom. Be sure that it is in the cold water inlet.
c. If using copper tubing, solder tubing to an adapter
BEFORE you attach the adapter to the cold water inlet. DO NOT solder the cold water supply pipe directly to the cold water inlet connection. It might harm the dip tube.
6” AIR GAP
TO SUITABLE
DRAIN
Figure 5.
Before lling the solar water heater with water, the pump
station storage tank loop must be connected to the water
heater. See “Filling The Storage Tank Loop” section of the
manual. The solar water heater is equipped with top and side pump
station water loop connections. Cap or plug the connections that are not used in your application.
1. Close the solar water heater drain valve. The drain valve is on the lower front of the solar water heater.
2. Open the cold water supply to the solar water heater. NOTE: THIS VALVE MUST BE LEFT OPEN WHEN THE SOLAR WATER HEATER IS IN USE.
3. Fill the solar water heater until a constant flow of water runs out an opened hot water faucet. This will let out air in the solar water heater and the piping. Close the faucet and solar loop air vent after all air has been purged and the water comes out with constant flow. You must not turn the electricity on until the solar water heater is full of water. IF ANY AIR IS LEFT IN THE TOP OF THE SOLAR WATER HEATER OR IN THE PUMP STATION STORAGE TANK LOOP THE HEATING ELEMENT WILL BURN OUT IMMEDIATELY.
4. Check all the new water piping for leaks. Fix as needed.
9
WIRING OF ELEMENT
BLACK
RED
BLACK
ELEMENT
RED
F
C)(66
F
(60 C)
F
C)(49
Determine voltage and wattage from the rating plate attached to the solar water heater. All external wiring, connection, and overcurrent protective devices must be provided and installed in accordance with the latest edition of the National Electrical Code, local codes, and local utility requirements. The solar water heater must be electrically
“grounded” by the installer. A green ground screw has been
provided on the solar water heater’s junction box. The grounding electrode conductor shall be of copper, aluminum, or copper clad aluminum. The material shall be resistant to corrosion, and shall be of one continuous length without a splice or joint. Rigid metal conduit, intermediate metal conduit, or electrical metallic tubing may be used for the grounding means if conduit or tubing is terminated in fittings approved for grounding.
Figure 6.
Flexible metal conduit or flexible metallic tubing shall be permitted for grounding if all the following conditions are met:
Figure 7.
THERMOSTAT
Each thermostat is factory preset at 120°F to reduce the risk of scald injury. This setting has proven by experience to be most satisfactory from the standpoint of operational costs and household needs. Solar water heaters installed in Florida require the thermostat(s) to be set at 125°F. If you wish to adjust the
settings, see the “Temperature Adjustment” section of this
installation manual on page 11.
TEMPERATURE REGULATION
1. The length in any ground return path does not exceed 6 feet.
2. The circuit conductors contained therein are protected by overcurrent devices rated at 20 amperes or less.
3. The conduit or tubing is terminated in fittings approved for grounding.
Never use this solar water heater unless it is completely full of water.
SOLAR WATER HEATERS EQUIPPED FOR ONE TYPE VOLTAGE ONLY. This solar water heater is equipped
for one type of voltage only. Check the rating plate near the bottom access panel for the correct voltage. DO NOT USE THIS SOLAR WATER HEATER WITH ANY VOLTAGE OTHER THAN THE ONE SHOWN ON THE MODEL RATING PLATE. Failure to use the correct voltage can cause problems which can result in DEATH, SERIOUS BODILY INJURY OR PROPERTY DAMAGE. If you have any questions or doubts consult your electric company.
If wiring from the fuse box or circuit breaker box was alumi­num for the old tank, replace it with copper wire. If you wish to reuse the existing aluminum wire, have the connection at the solar water heater made by a competent electrician. Contact your local utility to arrange for a professional elec­trician.
HOTTER WATER CAN SCALD: Solar water heaters are intended to produce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can cause scalds resulting in serious personal injury and/or death. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirmed, or physically handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. Please see Figure 8 and Table 2 for information regarding thermostat settings. In addition to using the lowest possible temperature setting that satisfies your hot water needs, some type of mixing device, such as a mixing valve should be used at the
10
hot water taps used by these people or at the solar water
THERMOSTAT
HIGH LIMIT
heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufacturers instructions for installation of the valves. Before changing the factory setting of the thermostat, read the Temperature Adjustment section. KEEPING THE THERMOSTAT SETTING AT 120°F WILL REDUCE THE RISK OF SCALDS. Never allow small children to use a hot water tap, or to draw their own bath water. Never leave a child or handicapped person unattended in a bathtub or shower.
TEMPERATURE SETTINGS
NOTE: This residential solar water heater will not supply sanitizing hot water for dishwashers.
The thermostat is factory set at its lowest position which approximates 120°F and is adjustable if a different water temperature is desired. For best system savings this temperature should not be changed. Read all warnings in this manual and on the solar water heater before proceeding.
CONTROL
RESET
BUTTON
ADJUSTABLE
WITH
HIGH LIMIT
Figure 8.
Water
Temperature °F
Time for 1st Degree
Burn
(Less Severe Burns)
110 116 116 122 131 140 149 154
(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15,1978)
(normal shower temp.)
(pain threshold)
35 minutes
1 minute 5 seconds 2 seconds
1 second
instantaneous
Table 2.
Time for Perma-
nent Burns 2nd &
3rd Degree (Most
Severe Burns)
45 minutes
5 minutes
25 seconds
5 seconds 2 seconds 1 seconds
TEMPERATURE ADJUSTMENT
To adjust the temperature setting:
1. Turn “OFF” the electrical power to the water heater, at
the junction box.
HAZARD OF ELECTRICAL SHOCK! Failure to turn “OFF” electric power to the solar water heater will result in the possibility of DEATH, SERIOUS BODILY INJURY OR PROPERTY DAMAGE.
2. Take off the access panel and fold away the insulation.
3. Turn the water temperature dial clockwise ( ) to increase the temperature, or counterclockwise ( ) to decrease the temperature.
4. Fold the insulation back in place and replace the access panel.
5. Turn “ON” the power supply.
A non-adjustable high temperature limit control operates before steam temperatures are reached. The high limit is in the same area as the upper thermostat and must be reset manually when it activates. BECAUSE THE HIGH LIMIT ACTIVATES ONLY WHEN ABNORMALLY HIGH WATER TEMPERATURES ARE PRESENT, IT IS IMPORTANT THAT A QUALIFIED SERVICE AGENT BE CONTACTED TO DETERMINE THE REASON FOR OPERATION BEFORE RESETTING.
TANK SENSOR
The surface mount tank sensor should be attached to the sensor stud behind the lower door by placing the hole in the sensor over the stud provided and securing in place with a nut. The end of the tank sensor shall be connected to the red wires in the opening with wire nuts (with no regard for polarity). The other ends of the red temperature sensor extension extend from the top of the tank and shall be connected to the controller in the tank sensor position.
DRAINING
It is recommended that the storage tank be drained and
ushed every 6 months to remove sediment which may
build up during operation. The water heater should be drained if being shut down during freezing temperatures. To drain the tank, perform the following steps:
1. Turn off power to the water heater.
2. Open a nearby hot water faucet until the water is no
longer hot.
3. Close the cold water inlet valve.
4. Connect a hose to the drain valve and terminate it to
an adequate drain or external to the building.
5. Open the water heater drain valve and allow all of the
water to drain from the tank. Flush the tank with water as needed to remove sediment.
6. Close the drain valve, rell the tank, and restart the
heater as directed in this manual.
If the water heater is going to be shut down for an extend­ed period, the drain valve should be left open.
IMPORTANT: Condensation may occur when relling the
tank and should not be confused with a tank leak.
If the solar water heater is to be shut off and exposed to
11
freezing temperatures, it must be drained. Water, if left in the tank and allowed to freeze, will expand and damage the solar water heater.
1. Turn “OFF” the electrical supply to the solar water heater.
Make sure the electrical supply to the solar water heater is turned OFF. Failure to heed this will result in the possibility of DEATH, SERIOUS BODILY INJURY OR PROPERTY DAMAGE.
2. Open a nearby hot water faucet until the water is no longer hot, then turn off the cold water supply and open the drain valve, leaving the hot water faucet open.
3. The drain valve must be left open during the shut-down period. Once the solar water heater is drained close the hot water faucet.
ELEMENT
In some water areas, scale or mineral deposits will build up on heating elements. This build up may cause a rumbling noise. Follow the element replacement directions to remove the elements from the tank. Soaking in vinegar and scraping will remove the mineral deposit. Be careful not to bend the element.
ELEMENT REPLACEMENT
Replacement elements must (1) be the same voltage and (2) no greater wattage than listed on the model and rating
plate afxed to the solar water heater.
1. Turn OFF the electrical supply to the solar water heater. Make sure the electrical supply to the solar water heater is turned OFF. Failure to heed this will result in the possibility of DEATH, SERIOUS BODILY INJURY OR PROPERTY DAMAGE.
2. Drain the solar water heater. Follow the directions for draining.
3. Take off the access panel and take off the access panel and remove the insulation. Disconnect the wires from the heating element terminals.
4. Use an element wrench to remove the element and gasket. You should always use a new gasket when you replace the element.
5. Install new element.
6. Reconnect the wires as they were.
7. Fill the tank , following the filling directions on page 9. Fill the tank completely with water, BEFORE you turn on the electric supply.
ANODE
Each water heater contains at least one anode rod, which will slowly deplete (due to electrolysis) prolonging the life of the water heater by protecting the glass-lined tank from corrosion. Adverse water quality, hotter water temperatures, high hot water usage, hydronic heating devices, and water softening methods can increase the rate of anode rod depletion. Once the anode rod is depleted, the tank will start to corrode, eventually developing a leak. Certain water conditions will cause a reaction between the anode rod and the water. The most common complaint
associated with the anode rod is a “rotten egg smell”
produced from the presence of hydrogen sulfide gas dissolved in the water. IMPORTANT: Do not remove this rod permanently as it may void any warranties. A special anode rod may be available if water odor or discoloration occurs. NOTE: This rod may reduce but not eliminate water odor problems. The water supply system may require special filtration equipment from a water conditioning company to
successfully eliminate all water odor problems. Artificially softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and calcium ions. The use of a water softener may decrease the life of the water heater tank. The anode rod should be inspected after a maximum of three years and annually thereafter until the condition of the anode rod dictates its replacement. NOTE: artificially softened water requires the anode rod to be inspected annually. The following are typical (but not all) signs of a depleted anode rod:
• The majority of the rod’s diameter is less than 3/8”.
• Significant sections of the support wire (approx. 1/3 or
more of the anode rod’s length) are visible.
If the anode rod shows signs of either or both it should be replaced. NOTE: Whether re-installing or replacing the anode rod, check for any leaks and immediately correct if found.
In replacing the anode:
1. Turn off power supply to the water heater.
2. Shut off the water supply and open a nearby hot water faucet to depressurize the water tank.
3. Drain approximately 5 gallons of water from tank. (Refer to
“Draining and Flushing” for proper
procedures). Close drain valve.
4. Remove old anode rod.
Figure 9.
5. Use Teflon® tape or approved pipe sealant on threads and install new anode rod.
6. Turn on water supply and open a nearby hot water faucet to purge air from water system. Check for any leaks and immediately correct any if found.
7. Restart the water heater as directed in this manual. See the Storage Tank Repair Parts section for anode rod location.
TEFLON® is a registered trademark of E.I. Du Pont De Nemours and Company.
Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of bodily injury under these conditions, open the hot water faucet for several minutes at the kitchen sink before any electrical appliances which are connected to the hot water system are used (such as a dishwasher or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is opened.
WATER HEATER SOUNDS
1. The solar water heater is equipped with an immersion
heating element for fastest recovery. If the solar water heater occasionally makes noises this is not a defect or a safety hazard.
2. Lime or scale has accumulated on the heating element
causing a hissing sound. Element scale removal can be accomplished by using vinegar or by scraping.