Solar Commercial Storage Tanks
FACTORY JACKETED AND INSULATED SOLAR
COMMERCIAL STORAGE TANKS
Large volume solar storage tanks from A. O. Smith are designed for storing
potable water. These storage tanks are fitted with additional openings to
suit the specific needs of solar thermal, commercial heat pump, and other
renewable energy heat sources.
These tanks are available as pre-configured Specialty Solar Tanks and as
Custom Solar Tanks built to specified application requirements. See the
Custom Solar Tank options on page 4 and consult your
factory representative for more information.
FEATURES
SPECIALTY SOLAR TANKS: Vertical tanks from 140 to 2,000 gallons,
horizontal tanks from 200 to 1,000 gallons. A. O. Smith commercial
solar storage tanks are constructed with openings for potable water
and solar thermal/renewable energy applications as shown in the
drawings that follow. These heavy duty storage tanks have been
designed for new construction and retrofit applications.
SJV-140 thru 2000
and
SJH-200 thru 1000
ASME CONSTRUCTION
I All tanks are ASME constructed at 160 psi working pressure.
Consult your factory representative for tanks with greater or
lesser working pressures
GLASSLINED
I Specialty Solar Tanks feature A. O. Smith PermaGlas®coating that
provides superior protection against corrosion and is fused to all
inner tank surfaces at 1600°F
INSULATION
I All tanks are surrounded with 3 inches of high density fiberglass insulation to reduce
costly heat loss; insulation is non-sagging and verminproof. To meet ASHRAE 90.1 (current
edition) depth of insulation cavity requires use of remote bulb-type tank temperature control
and thermometer. Storage tanks meet R12.5 minimum thermal insulation requirements of the
U.S. Department of Energy and current edition of ASHRAE/IESNA 90.1
JACKET/CABINET
I All tanks feature heavy gauge steel with high quality powder coat paint that provides
additional insulating qualities for greater energy savings
CATHODIC PROTECTION
I All tanks are furnished with factory installed magnesium anodes designed for
maximum protection
CONNECTIONS
I Tanks will be supplied with the fittings located as indicated on the drawings unless specified
otherwise. Manhole or handholes are optional on glasslined tanks but are included on
cement lined tanks
TEMPERATURE SENSORS
I Factory installed upper and lower temperature sensor wells with Pt1000 type sensors and
internal wiring pre-installed.
These storage tanks are
eligible for a 30% federal tax
credit when installed as part of
a complete commercial solar
thermal hot water system.
CUSTOM SOLAR TANKS: See options and suggested specification on page 4.
Page 1 of 4
AOSCE16000
B
C
D
F
E
A
ANODE
ANODE
I
I
H
FOR SHIPPING
ONLY
LIFTING LUGS
JACKET (CABINET)
SOLAR RETURN
SOLAR DRAW
DRAIN
(MALE NPT)
COLD INLET
HOT OUTLET
SENSOR WELL
T&P VALVE
OPENING
SENSOR WELL
SENSOR WELL
G
FRONT VIEW SIDE VIEW TOP VIEW
A
K
H
J
J
J
SENSOR WIRING
3" INSULATION
VERTICAL STORAGE TANKS
Solar Commercial Storage Tanks
DRAWING NOTES:
I Inspection openings, IE: handholes and manholes, are optional with glasslined or stainless steel tanks and will only be included when specified. Tanks so
equipped are FOB Seattle.
I All openings female pipe thread except as noted.
I Number of factory installed anode rods will vary with tank size.
SJV-140 THROUGH SJV-2000
SOLAR
DRAW
HEIGHT
B C
MODEL
NOMINAL
VOLUME
(GALLONS)
GLASSLINED
DRY WEIGHT
(LBS.)
WIDTH
A
HEIGHT
SJV-140 140 613 30 86 13 18 1/2 19 49 1/2 1 1/2 2 1/2 1 1/2 1/2 1
SJV-200 200 749 36 82 14 20 20 48 1 1/2 2 1/2 1 1/2 1/2 1
SJV-250 250 811 36 95 14 20 20 54 1 1/2 2 1/2 1 1/2 1/2 1
SJV-300T 300 898 36 110 14 20 20 62 1 1/2 2 1/2 1 1/2 1/2 1
SJV-300S 300 857 42 82 15 1/2 21 1/2 22 48 1 1/2 2 1/2 2 1/2 1
SJV-350 350 942 42 97 15 1/2 21 1/2 22 56 1 1/2 2 1/2 1 1/2 1/2 1
SJV-400 400 1436 42 104 15 1/2 21 1/2 22 59 1 1/2 2 1/2 2 1/2 1
SJV-450 450 1565 42 118 15 1/2 21 1/2 22 66 1/2 1 1/2 2 1/2 2 1/2 1
SJV-500T 500 1682 42 133 15 1/2 21 1/2 22 74 1 1/2 2 1/2 2 1/2 1
SJV-500S 500 1714 48 99 17 23 23 1/2 57 1 1/2 3 2 1/2 1/2 1
SJV-600 600 1820 48 114 17 23 23 1/2 65 1 1/2 3 2 1/2 1
SJV-700 700 1911 48 130 17 23 23 1/2 73 1 1/2 3 2 1/2 1
SJV-800 800 2974 54 120 18 24 1/2 25 68 1 1/2 3 2 1/2 1/2 1
SJV-900 900 3208 54 128 18 24 1/2 25 72 1 1/2 3 2 1/2 1/2 1
SJV-1000T 1000 3697 54 148 18 24 1/2 25 82 1 1/2 3 2 1/2 1/2 1 1/2
SJV-1000S 1000 3947 **66 99 21 27 1/2 28 58 1 1/2 3 3 1/2 1 1/2
SJV-1500 1500 4456 **60 164 19 1/2 26 26 1/2 90 1/2 1 1/2 3 3 1/2 1 1/2
SJV-2000T 2000 6035 **66 176 21 27 1/2 28 97 1 1/2 3 3 1/2 1 1/2
SJV-2000S 2000 5952 **78 131 24 30 1/2 31 75 1 1/2 3 3 1/2 1 1/2
All dimensions are in inches.
Four vertical tanks are available in short and tall models. The S and T designators at the end of the model numbers are used to identify these models.
* Sensor well openings are 1/2" NPT female. All models have factory installed Pt1000 temperature sensors and wiring to an external junction box. Access covers are provided for field
supplied temperature sensors and servicing.
** These models will have rectangular jackets when manufactured for indoor use. All other models will have round jackets.
www.hotwater.com AOSCE16000
A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
LOWER
SENSOR
HEIGHT
D
COLD
INLET
HEIGHT
E F
SOLAR
RETURN
HEIGHT
DRAIN
(IN. NPT)
G
INLET/OUTLET
CONNECTIONS
(IN. NPT)
H
SOLAR LOOP
CONNECTIONS
(IN. NPT)
I
*SENSOR
WELLS
(IN. NPT)
J K
T&P VALVE
OPENING
(IN. NPT)